A residential electric storage water heater consumed a total of E=4.50 kW⋅hE = 4.50\ \text{kW}\cdot\text{h} of electrical energy during a heating cycle lasting Δt=75.0 min\Delta t = 75.0\ \text{min} across a nominal line voltage of V=240 VV = 240\ \text{V}. Assuming the heating element acts as an ideal ohmic resistor, determine: (a) the average electric power PP dissipated by the element in kilowatts, and (b) the initial electrical resistance RR of the submerged heating element.

Answer and steps

Final answer

(a) P=3.60 kWP = 3.60\ \text{kW}; (b) R=16.0 ΩR = 16.0\ \Omega

Steps

Part (a): Calculating the Average Electric Power (PP)

Electric power measures the rate at which electrical energy is transferred or consumed over time: P=EΔtP = \frac{E}{\Delta t}

  1. Convert the heating time to hours so the unit matches kW⋅h\text{kW}\cdot\text{h}: Δt=75.0 min×1 h60 min=1.25 h\Delta t = 75.0\ \text{min} \times \frac{1\ \text{h}}{60\ \text{min}} = 1.25\ \text{h}
  2. Compute the power: P=4.50 kW⋅h1.25 h=3.60 kWP = \frac{4.50\ \text{kW}\cdot\text{h}}{1.25\ \text{h}} = 3.60\ \text{kW}

Part (b): Calculating the Electrical Resistance (RR)

For an ideal ohmic resistor operating across an electric potential difference VV, power is related to voltage and resistance by: P=V2RP = \frac{V^2}{R}

Rearranging to solve for resistance RR: R=V2PR = \frac{V^2}{P}

  1. Convert power to standard SI units (watts): P=3.60 kW=3600 WP = 3.60\ \text{kW} = 3600\ \text{W}

    Common Pitfall: Always convert power from kilowatts (kW\text{kW}) to watts (W\text{W}) before calculating resistance with voltage in volts (V\text{V}). Using 3.603.60 instead of 36003600 would result in an incorrect resistance off by a factor of 10001000.

  2. Substitute the nominal voltage and power: R=(240 V)23600 W=57 600 V23600 W=16.0 ΩR = \frac{(240\ \text{V})^2}{3600\ \text{W}} = \frac{57\,600\ \text{V}^2}{3600\ \text{W}} = 16.0\ \Omega

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student divides energy by time in minutes without converting minutes to hours, yielding an incorrect power of 0.060 kW.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P=EΔt  ⟹  P=4.5075.0  ⟹  P=0.060 kWP = \frac{E}{\Delta t} \implies P = \frac{4.50}{75.0} \implies P = 0.060\text{ kW}

    Correct

    Δt=75.0 min×1 h60 min=1.25 h  ⟹  P=4.50 kW⋅h1.25 h=3.60 kW\Delta t = 75.0\text{ min} \times \frac{1\text{ h}}{60\text{ min}} = 1.25\text{ h} \implies P = \frac{4.50\text{ kW}\cdot\text{h}}{1.25\text{ h}} = 3.60\text{ kW}

    You correctly recalled the definition of average power P=EΔtP = \frac{E}{\Delta t}. However, because the energy was given in kilowatt-hours (kW⋅h\text{kW}\cdot\text{h}), the time interval must be in hours before dividing. Dividing 4.50 kW⋅h4.50\text{ kW}\cdot\text{h} by 75.0 min75.0\text{ min} yields 0.060 kW⋅h/min0.060\text{ kW}\cdot\text{h}/\text{min} rather than kilowatts.

  2. Step 2

    P=60 WP = 60\text{ W}

    Correct

    P=3.60 kW=3600 WP = 3.60\text{ kW} = 3600\text{ W}

    Your conversion from kilowatts to watts (0.060 kW=60 W0.060\text{ kW} = 60\text{ W}) was carried out correctly, but the numerical value was carried over from your incorrect result in part (a).

  3. Step 3

    R=V2P  ⟹  R=240260  ⟹  R=5760060=960 ΩR = \frac{V^2}{P} \implies R = \frac{240^2}{60} \implies R = \frac{57600}{60} = 960\ \Omega

    Correct

    R=V2P=(240 V)23600 W=57 600 V23600 W=16.0 ΩR = \frac{V^2}{P} = \frac{(240\text{ V})^2}{3600\text{ W}} = \frac{57\,600\text{ V}^2}{3600\text{ W}} = 16.0\ \Omega

    You selected the correct formula relating voltage, power, and resistance (R=V2PR = \frac{V^2}{P}) and performed the arithmetic without error. Your final answer is off because it used the affected power value of 60 W60\text{ W} instead of 3600 W3600\text{ W}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the fundamental formula P=EΔtP = \frac{E}{\Delta t} to calculate average power.

You recognized that power in kilowatts must be converted to watts before calculating resistance using volts in SI units.

You accurately rearranged and applied the ohmic power relationship R=V2PR = \frac{V^2}{P}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion omission in power calculation

You substituted the duration Δt=75.0 min\Delta t = 75.0\text{ min} directly into the denominator without converting minutes to hours to cancel the hours in kW⋅h\text{kW}\cdot\text{h}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating composite non-standard units (such as kW⋅h\text{kW}\cdot\text{h}) as purely numerical values during substitution, rather than explicitly tracking and matching unit dimensions across numerator and denominator.

REASONING PATH
Your ACEpath teacher’s suggested approach
Match composite energy units to time units
  • Because 1 kW⋅h=1 kW×1 h1\text{ kW}\cdot\text{h} = 1\text{ kW} \times 1\text{ h}, dividing by time requires Δt\Delta t to be expressed in hours so that the time units cancel: kW⋅hh=kW\frac{\text{kW}\cdot\text{h}}{\text{h}} = \text{kW}.

  • Always write out units during substitution: 4.50 kW⋅h75.0 min×60 min1 h=3.60 kW\frac{4.50\text{ kW}\cdot\text{h}}{75.0\text{ min}} \times \frac{60\text{ min}}{1\text{ h}} = 3.60\text{ kW}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert the heating cycle time into hours: Δt=75.0 min60 min/h=1.25 h\Delta t = \frac{75.0\text{ min}}{60\text{ min/h}} = 1.25\text{ h}.

  2. Recalculate power in kilowatts: P=4.50 kW⋅h1.25 h=3.60 kWP = \frac{4.50\text{ kW}\cdot\text{h}}{1.25\text{ h}} = 3.60\text{ kW}.

  3. Convert power to SI units for resistance calculation: P=3.60 kW=3600 WP = 3.60\text{ kW} = 3600\text{ W}.

  4. Re-evaluate the element's resistance: R=V2P=(240 V)23600 W=57 6003600=16.0 ΩR = \frac{V^2}{P} = \frac{(240\text{ V})^2}{3600\text{ W}} = \frac{57\,600}{3600} = 16.0\ \Omega.

Final answer

(a) P=3.60 kWP = 3.60\text{ kW}; (b) R=16.0 ΩR = 16.0\ \Omega

NEXT STEPS
Final Takeaways from Your Teacher
  • Include explicit measurement units alongside numbers inside your calculation fractions to catch unit mismatches before evaluating.

  • Practice converting commercial energy units (kW⋅h\text{kW}\cdot\text{h}) into standard SI units (J\text{J}) or matching time bases (h\text{h}) as a first reflex.

OverviewACEpath Teacher's Diagnosis

02 The student uses the power in kilowatts directly in the formula R = V² / P instead of converting to watts, resulting in an incorrect resistance of 16000 Ω.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Δt=75.060=1.25 h\Delta t = \frac{75.0}{60} = 1.25\text{ h}

  2. Step 2

    P=4.501.25=3.60 kWP = \frac{4.50}{1.25} = 3.60\text{ kW}

  3. Step 3

    R=V2PR = \frac{V^2}{P}

  4. Step 4

    R=24023.60  ⟹  R=576003.60R = \frac{240^2}{3.60} \implies R = \frac{57600}{3.60}

    Correct

    R=(240 V)23600 W=57600 V23600 WR = \frac{(240\text{ V})^2}{3600\text{ W}} = \frac{57600\text{ V}^2}{3600\text{ W}}

    You substituted the power as 3.60 kW3.60\text{ kW} instead of converting it to standard SI units (3600 W3600\text{ W}). Because the ohm is defined as V2/W\text{V}^2 / \text{W}, power must be in watts.

  5. Step 5

    R=16000 ΩR = 16000\ \Omega

    Correct

    R=16.0 ΩR = 16.0\ \Omega

    Your arithmetic evaluation was correct for the substituted numbers, but the result is off by a factor of 10001000 due to the unit error in the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You converted time into hours to determine the average power in kilowatts accurately.

You recognized the correct relationship between resistance, potential difference, and power as R=V2PR = \frac{V^2}{P}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit mismatch in circuit formula

You plugged in the power value in kilowatts directly alongside voltage in volts without converting kilowatts to watts.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking the SI base unit coherence required by Ohm's law and Joule's law formulas: 1 Ω=1 V2/W1\ \Omega = 1\text{ V}^2 / \text{W}, which requires power to be in watts (W) rather than kilowatts (kW).

REASONING PATH
Your ACEpath teacher’s suggested approach
Verify SI Unit Coherence
  • Electrical formulas involving volts (VV), amperes (AA), and ohms (Ω\Omega) require power in watts (W\text{W}), where 1 kW=1000 W1\text{ kW} = 1000\text{ W}.

  • Always convert power values with metric prefixes (like kW\text{kW} or mW\text{mW}) into base watts before using formulas like R=V2PR = \frac{V^2}{P}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert the power from kilowatts to watts: P=3.60 kW=3.60×103 W=3600 WP = 3.60\text{ kW} = 3.60 \times 10^3\text{ W} = 3600\text{ W}.

  2. Substitute V=240 VV = 240\text{ V} and P=3600 WP = 3600\text{ W} into the resistance formula: R=(240 V)23600 W=576003600 ΩR = \frac{(240\text{ V})^2}{3600\text{ W}} = \frac{57600}{3600}\ \Omega.

  3. Divide to find the resistance: R=16.0 ΩR = 16.0\ \Omega.

Final answer

(a) P=3.60 kWP = 3.60\text{ kW}; (b) R=16.0 ΩR = 16.0\ \Omega

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out explicit units during each algebraic substitution step to ensure derived units cancel out correctly.

  • Practice distinguishing when non-standard units (such as kW⋅h\text{kW}\cdot\text{h}) are appropriate versus when standard SI units (joules and watts) are mandatory.

OverviewACEpath Teacher's Diagnosis

03 The student forgets to square the voltage in the power-resistance relation, mistakenly using R = V / P instead of R = V² / P.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Δt=75.060=1.25 h\Delta t = \frac{75.0}{60} = 1.25\text{ h}

  2. Step 2

    P=4.501.25=3.60 kWP = \frac{4.50}{1.25} = 3.60\text{ kW}

  3. Step 3

    P=3600 WP = 3600\text{ W}

  4. Step 4

    R=VPR = \frac{V}{P}

    Correct

    R=V2PR = \frac{V^2}{P}

    You forgot to square the voltage when relating power to resistance. Because P=V2RP = \frac{V^2}{R}, solving for resistance gives R=V2PR = \frac{V^2}{P}.

  5. Step 5

    R=2403600  ⟹  R=0.067 ΩR = \frac{240}{3600} \implies R = 0.067\ \Omega

    Correct

    R=(240 V)23600 W=57 6003600=16.0 ΩR = \frac{(240\text{ V})^2}{3600\text{ W}} = \frac{57\,600}{3600} = 16.0\ \Omega

    Your numerical substitution and rounding followed your stated formula, but the final resistance was affected by the missing squared term.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the heating time from minutes to hours to match the energy unit.

You accurately found the average power in kilowatts using P=EΔtP = \frac{E}{\Delta t}.

You correctly converted power into watts (3600 W3600\text{ W}) for SI consistency.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula recall error

You wrote R=VPR = \frac{V}{P} rather than R=V2PR = \frac{V^2}{P}, likely confounding Ohm's law (R=VIR = \frac{V}{I}) with the electric power relation.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the linear relationship between voltage and current in Ohm's law (V=IRV = IR) with the quadratic relationship between voltage and electrical power (P=V2RP = \frac{V^2}{R} or P=I2RP = I^2R).

REASONING PATH
Your ACEpath teacher’s suggested approach
Power-Voltage-Resistance Formula
  • For an ohmic resistor, P=IV=I2R=V2RP = IV = I^2R = \frac{V^2}{R}.

  • Derive the formula by combining P=IVP = IV and I=VRI = \frac{V}{R} to verify that voltage is squared: P=(VR)V=V2RP = \left(\frac{V}{R}\right)V = \frac{V^2}{R}.

Unit and Dimensional Check
  • Resistance has units of ohms ( Ω=V/A\,\Omega = \text{V}/\text{A}), whereas VP=VV⋅A=1A\frac{V}{P} = \frac{\text{V}}{\text{V}\cdot\text{A}} = \frac{1}{\text{A}}.

  • Check the dimensions of your expression before plugging in numbers: V2P=V2V⋅A=VA=Ω\frac{V^2}{P} = \frac{\text{V}^2}{\text{V}\cdot\text{A}} = \frac{\text{V}}{\text{A}} = \Omega.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Start from the ohmic power relation: P=V2RP = \frac{V^2}{R}.

  2. Rearrange for resistance: R=V2PR = \frac{V^2}{P}.

  3. Substitute V=240 VV = 240\text{ V} and P=3600 WP = 3600\text{ W}: R=(240)23600=57 6003600=16.0 ΩR = \frac{(240)^2}{3600} = \frac{57\,600}{3600} = 16.0\ \Omega.

Final answer

R=16.0 ΩR = 16.0\ \Omega

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the three fundamental power formulas for resistors (P=IVP = IV, P=I2RP = I^2R, and P=V2RP = \frac{V^2}{R}) and practice deriving them from Ohm's law.

  • Perform a quick dimensional check whenever you rearrange formulas involving power, voltage, and resistance.

Lock it in

Similar question

01

An electric oven consumes E=3.00 kW⋅hE = 3.00\text{ kW}\cdot\text{h} over a baking period of Δt=45.0 min\Delta t = 45.0\text{ min}. Determine the average power rating PP of the oven in kilowatts.

Answer

P=4.00 kWP = 4.00\text{ kW}. Key steps: Convert time to hours: Δt=45.0 min×1 h60 min=0.750 h\Delta t = 45.0\text{ min} \times \frac{1\text{ h}}{60\text{ min}} = 0.750\text{ h}. Calculate power: P=EΔt=3.00 kW⋅h0.750 h=4.00 kWP = \frac{E}{\Delta t} = \frac{3.00\text{ kW}\cdot\text{h}}{0.750\text{ h}} = 4.00\text{ kW}.

02

A space heater rated at V=120 VV = 120\text{ V} consumes E=2.40 kW⋅hE = 2.40\text{ kW}\cdot\text{h} during a run time of Δt=80.0 min\Delta t = 80.0\text{ min}. Assuming it behaves as an ideal resistor, calculate: (a) its power consumption in kilowatts, and (b) its internal electrical resistance RR in ohms.

Answer

(a) P=1.80 kWP = 1.80\text{ kW}; (b) R=8.00 ΩR = 8.00\ \Omega. Key steps: (a) Δt=80.060 h=43 h≈1.333 h\Delta t = \frac{80.0}{60}\text{ h} = \frac{4}{3}\text{ h} \approx 1.333\text{ h}. Power P=2.40 kW⋅h4/3 h=1.80 kWP = \frac{2.40\text{ kW}\cdot\text{h}}{4/3\text{ h}} = 1.80\text{ kW}. (b) Convert power to watts: P=1800 WP = 1800\text{ W}. Use R=V2P=(120 V)21800 W=14 4001800=8.00 ΩR = \frac{V^2}{P} = \frac{(120\text{ V})^2}{1800\text{ W}} = \frac{14\,400}{1800} = 8.00\ \Omega.

03

An industrial immersion heater has an ohmic resistance of R=12.0 ΩR = 12.0\ \Omega and operates connected to a 240 V240\text{ V} line. How much energy in kW⋅h\text{kW}\cdot\text{h} does it consume if it runs continuously for 50.0 min50.0\text{ min}?

Answer

E=4.00 kW⋅hE = 4.00\text{ kW}\cdot\text{h}. Key steps: Compute power dissipation in watts: P=V2R=(240 V)212.0 Ω=57 60012.0=4800 W=4.80 kWP = \frac{V^2}{R} = \frac{(240\text{ V})^2}{12.0\ \Omega} = \frac{57\,600}{12.0} = 4800\text{ W} = 4.80\text{ kW}. Convert time to hours: Δt=50.060 h=56 h\Delta t = \frac{50.0}{60}\text{ h} = \frac{5}{6}\text{ h}. Compute energy: E=P⋅Δt=4.80 kW×56 h=4.00 kW⋅hE = P \cdot \Delta t = 4.80\text{ kW} \times \frac{5}{6}\text{ h} = 4.00\text{ kW}\cdot\text{h}.