Resources

A clinical laboratory handles a sample of fluorine-18 (18F^{18}\text{F}) with a half-life of t1/2=109.8 mint_{1/2} = 109.8\text{ min}. Standard radiological safety regulations stipulate that the sample is considered safe for routine disposal only after its total activity has decayed to less than 0.100%0.100\% (0.001000.00100) of its initial activity A0A_0. Calculate the minimum elapsed time tsafet_{\text{safe}} in hours required for the sample to reach this critical safety threshold.

Answer and steps

Final answer

18.2 hours18.2\text{ hours}

Steps

01

Determine the Number of Half-Lives

Radioactive Decay Law

The activity A(t)A(t) of a radioactive sample at time tt decreases exponentially from its initial activity A0A_0 according to the half-life decay formula: A(t)=A0(12)t/t1/2A(t) = A_0 \left(\frac{1}{2}\right)^{t / t_{1/2}} where:

  • t1/2=109.8 mint_{1/2} = 109.8\text{ min} is the half-life of fluorine-18,
  • A(t)A0\frac{A(t)}{A_0} is the remaining fraction of the initial activity.

The safety threshold requires the activity to drop to 0.100%0.100\% of its original level:

A(tsafe)A0=0.00100=10−3\frac{A(t_{\text{safe}})}{A_0} = 0.00100 = 10^{-3}

Substitute this ratio into the decay equation, where n=tsafet1/2n = \frac{t_{\text{safe}}}{t_{1/2}} represents the number of elapsed half-lives:

(12)n=0.00100\left(\frac{1}{2}\right)^n = 0.00100

Taking the natural logarithm (or base-10 logarithm) on both sides:

ln⁡((12)n)=ln⁡(0.00100)\ln\left(\left(\frac{1}{2}\right)^n\right) = \ln(0.00100)

−nln⁡(2)=ln⁡(10−3)=−3ln⁡(10)-n \ln(2) = \ln(10^{-3}) = -3 \ln(10)

Solve for nn:

n=3ln⁡(10)ln⁡(2)≈3⋅2.302590.69315≈9.966 half-livesn = \frac{3 \ln(10)}{\ln(2)} \approx \frac{3 \cdot 2.30259}{0.69315} \approx 9.966\text{ half-lives}


02

Calculate the Elapsed Time in Minutes

Multiply the number of half-lives by the half-life duration:

tsafe=n⋅t1/2≈9.966⋅109.8 min≈1094.27 mint_{\text{safe}} = n \cdot t_{1/2} \approx 9.966 \cdot 109.8\text{ min} \approx 1094.27\text{ min}


03

Convert Time to Hours

Convert the elapsed time from minutes to hours:

tsafe=1094.27 min60 min/h≈18.238 hourst_{\text{safe}} = \frac{1094.27\text{ min}}{60\text{ min/h}} \approx 18.238\text{ hours}

Rounding to three significant figures gives:

tsafe≈18.2 hourst_{\text{safe}} \approx 18.2\text{ hours}

(Pitfall: Be careful not to round nn to 1010 half-lives too early. While 210=1024≈10002^{10} = 1024 \approx 1000, rounding early gives 10⋅109.8/60=18.3 h10 \cdot 109.8 / 60 = 18.3\text{ h}, which introduces unnecessary rounding error before the final step.)

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert the final elapsed time from minutes to hours.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    A(t)=A0(1/2)t/t1/2  ⟹  0.00100=(1/2)t/109.8  ⟹  ln⁡(0.00100)=t109.8⋅ln⁡(0.5)A(t) = A_0 (1/2)^{t/t_{1/2}} \implies 0.00100 = (1/2)^{t/109.8} \implies \ln(0.00100) = \frac{t}{109.8} \cdot \ln(0.5)

  2. Step 2

    −6.9078=−0.6931⋅t109.8  ⟹  t109.8=9.966-6.9078 = -0.6931 \cdot \frac{t}{109.8} \implies \frac{t}{109.8} = 9.966

  3. Step 3

    tsafe=1094.3 hourst_{\text{safe}} = 1094.3\text{ hours}

    Correct

    tsafe=9.966×109.8 min≈1094.3 min=1094.360 h≈18.2 hourst_{\text{safe}} = 9.966 \times 109.8\text{ min} \approx 1094.3\text{ min} = \frac{1094.3}{60}\text{ h} \approx 18.2\text{ hours}

    Because the half-life t1/2=109.8t_{1/2} = 109.8 was in minutes, multiplying by 9.9669.966 produces time in minutes (1094.3 min1094.3\text{ min}). You assigned the unit 'hours' without dividing by 60 min/h60\text{ min/h}.

WHAT YOU DID WELL
Compliments from Your Teacher

You selected and applied the correct radioactive decay model.

You used natural logarithms accurately to solve for the exponent.

You maintained appropriate intermediate precision without premature rounding.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted unit conversion from minutes to hours

You attached the requested target unit ('hours') directly to a numerical result that was still in minutes.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating the half-life value t1/2t_{1/2} as a dimensionless scalar during algebraic manipulation caused you to lose track of its base time unit (minutes) before finalizing the answer.

REASONING PATH
Your ACEpath teacher’s suggested approach
Carry Units Through the Calculation
  • In decay formulas t=n⋅t1/2t = n \cdot t_{1/2}, the elapsed time tt always inherits the exact time unit of t1/2t_{1/2}.

  • Explicitly write '1094.3 min1094.3\text{ min}' before looking at the requested unit.

Verify Target Units Against Question Prompts
  • Always perform a final dimensional check against the prompt's required unit before boxing the answer.

  • Convert minutes to hours using 1 h60 min\frac{1\text{ h}}{60\text{ min}} whenever a question asks for hours but supplies half-life in minutes.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. tsafe=9.966×109.8 min≈1094.3 mint_{\text{safe}} = 9.966 \times 109.8\text{ min} \approx 1094.3\text{ min}

  2. tsafe=1094.3 min60 min/h≈18.238 hourst_{\text{safe}} = \frac{1094.3\text{ min}}{60\text{ min/h}} \approx 18.238\text{ hours}

Final answer

18.2 hours18.2\text{ hours}

NEXT STEPS
Final Takeaways from Your Teacher
  • Include explicit unit symbols alongside numerical constants throughout multi-step physics equations.

  • Highlight the required final units in problem statements during your first read-through.

  • Perform a sanity check: 1094 hours1094\text{ hours} is over 45 days45\text{ days}, which is disproportionately long for a medical isotope with a half-life of under two hours decaying by a factor of 10001000.

OverviewACEpath Teacher's Diagnosis

02 The student misinterprets 0.100% as a fraction of 0.0100 instead of 0.00100.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    A/A0=(12)t109.8A/A_0 = \left(\frac{1}{2}\right)^{\frac{t}{109.8}}

  2. Step 2

    0.0100=(0.5)t109.80.0100 = (0.5)^{\frac{t}{109.8}}

    Correct

    0.00100=(0.5)t109.80.00100 = (0.5)^{\frac{t}{109.8}}

    You substituted 0.01000.0100 for the remaining fraction, but 0.100%=0.100100=0.001000.100\% = \frac{0.100}{100} = 0.00100 (10−310^{-3}). The decimal 0.01000.0100 corresponds to 1.00%1.00\%.

  3. Step 3

    t109.8=ln⁡(0.0100)ln⁡(0.5)  ⟹  t109.8=−4.6052−0.6931=6.644  ⟹  t=729.5 min\frac{t}{109.8} = \frac{\ln(0.0100)}{\ln(0.5)} \implies \frac{t}{109.8} = \frac{-4.6052}{-0.6931} = 6.644 \implies t = 729.5\text{ min}

    Correct

    t109.8=ln⁡(0.00100)ln⁡(0.5)≈9.966  ⟹  t≈1094.3 min\frac{t}{109.8} = \frac{\ln(0.00100)}{\ln(0.5)} \approx 9.966 \implies t \approx 1094.3\text{ min}

    Your logarithmic solving technique and arithmetic were accurate for the value you wrote, but the result was thrown off by the incorrect fraction from the previous step.

  4. Step 4

    tsafe=729.560=12.2 hourst_{\text{safe}} = \frac{729.5}{60} = 12.2\text{ hours}

    Correct

    tsafe=1094.360≈18.2 hourst_{\text{safe}} = \frac{1094.3}{60} \approx 18.2\text{ hours}

    You converted correctly from minutes to hours by dividing by 6060, but the numerical value inherits the earlier decimal placement error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recalled and stated the exponential half-life decay formula.

You applied natural logarithms accurately to isolate the exponent.

You correctly converted the final time from minutes to hours.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Percentage-to-decimal conversion error

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You divided 0.1000.100 by 1010 instead of 100100 when converting a percentage into a decimal ratio, confusing 0.1%0.1\% (10−310^{-3}) with 1%1\% (10−210^{-2}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Percentage to Decimal Rule
  • To convert a percentage to a decimal, divide by 100100 (move the decimal point two places to the left): x%=x100x\% = \frac{x}{100}.

  • Always verify: 10%=0.110\% = 0.1, 1%=0.011\% = 0.01, and 0.1%=0.0010.1\% = 0.001.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. A(tsafe)A0=0.100%=0.00100=10−3\frac{A(t_{\text{safe}})}{A_0} = 0.100\% = 0.00100 = 10^{-3}

  2. $(12)\left(\frac{1}{2}\right)^{tsafe109.8\frac{t_{\text{safe}}}{109.8}} = 0.00100   ⟹  \implies tsafe109.8\frac{t_{\text{safe}}}{109.8} = ln⁡(0.00100)ln⁡(0.5)\frac{\ln(0.00100)}{\ln(0.5)} = −6.9078−0.6931\frac{-6.9078}{-0.6931} ≈\approx 9.966$$

  3. t_{safe\text{safe}} = 9.966 ×\times 109.8 min\text{ min} ≈\approx 1094.3 min\text{ min}$_

  4. tsafe=1094.3 min60 min/h≈18.2 hourst_{\text{safe}} = \frac{1094.3\text{ min}}{60\text{ min/h}} \approx 18.2\text{ hours}

Final answer

18.2 hours18.2\text{ hours}

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check conversions of percentages less than 1%1\% by writing them explicitly as fractions over 100100 before using them in equations.

  • Practice quick mental bounds: since (1/2)10=1/1024≈1/1000=0.1%(1/2)^{10} = 1/1024 \approx 1/1000 = 0.1\%, you should expect roughly 1010 half-lives rather than 6.66.6 half-lives.

OverviewACEpath Teacher's Diagnosis

03 The student assumes linear decay by calculating decay rate as 50% per 109.8 min rather than exponential decay.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Sample must decay by 100%−0.100%=99.9%\text{Sample must decay by } 100\% - 0.100\% = 99.9\%

  2. Step 2

    Decay rate=50%109.8 min  ⟹  t=99.9%(50%/109.8 min)  ⟹  t=99.9⋅2.196=219.4 min\text{Decay rate} = \frac{50\%}{109.8\text{ min}} \implies t = \frac{99.9\%}{(50\%/109.8\text{ min})} \implies t = 99.9 \cdot 2.196 = 219.4\text{ min}

    Correct

    (12)n=0.00100  ⟹  n=ln⁡(0.00100)ln⁡(0.5)≈9.966  ⟹  t=9.966×109.8 min≈1094.3 min\left(\frac{1}{2}\right)^n = 0.00100 \implies n = \frac{\ln(0.00100)}{\ln(0.5)} \approx 9.966 \implies t = 9.966 \times 109.8\text{ min} \approx 1094.3\text{ min}

    You assumed the sample loses activity at a constant linear rate of 50%50\% per half-life. Radioactive decay is an exponential process where each half-life halves the remaining activity: A(t)=A0(12)t/t1/2A(t) = A_0 \left(\frac{1}{2}\right)^{t/t_{1/2}}.

  3. Step 3

    tsafe=219.460=3.66 hourst_{\text{safe}} = \frac{219.4}{60} = 3.66\text{ hours}

    Correct

    tsafe=1094.3 min60 min/h≈18.2 hourst_{\text{safe}} = \frac{1094.3\text{ min}}{60\text{ min/h}} \approx 18.2\text{ hours}

    You converted minutes to hours correctly by dividing by 6060, but the numerical value was incorrect due to the linear decay formula used in Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that reaching 0.100%0.100\% of initial activity requires 99.9%99.9\% of the initial activity to decay.

You correctly converted your calculated elapsed time from minutes to hours by dividing by 6060.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Linear vs. Exponential Decay Confusion

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated radioactive decay as a linear process with a constant rate of 50%50\% of initial activity per 109.8 min109.8\text{ min}, instead of an exponential process where the remaining activity is multiplied by 12\frac{1}{2} for each elapsed half-life.

REASONING PATH
Your ACEpath teacher’s suggested approach
Radioactive Decay is Multiplicative, Not Additive
  • Over each half-life t1/2t_{1/2}, remaining activity drops by a factor of 12\frac{1}{2}, governed by A(t)=A0(12)t/t1/2A(t) = A_0 \left(\frac{1}{2}\right)^{t/t_{1/2}}. It never reaches zero at 2×t1/22 \times t_{1/2}.

  • Express the target fraction as (12)n=A(t)A0\left(\frac{1}{2}\right)^n = \frac{A(t)}{A_0} and use logarithms to solve for the number of half-lives n=tt1/2n = \frac{t}{t_{1/2}}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the exponential half-life decay equation: A(tsafe)A0=(12)n=0.00100\frac{A(t_{\text{safe}})}{A_0} = \left(\frac{1}{2}\right)^n = 0.00100, where n=tsafet1/2n = \frac{t_{\text{safe}}}{t_{1/2}}.

  2. Take the natural logarithm of both sides: ln⁡((12)n)=ln⁡(0.00100)\ln\left(\left(\frac{1}{2}\right)^n\right) = \ln(0.00100), which simplifies to −nln⁡(2)=ln⁡(10−3)=−3ln⁡(10)-n \ln(2) = \ln(10^{-3}) = -3 \ln(10).

  3. Solve for the number of elapsed half-lives: n=3ln⁡(10)ln⁡(2)≈6.90780.69315≈9.966n = \frac{3 \ln(10)}{\ln(2)} \approx \frac{6.9078}{0.69315} \approx 9.966.

  4. Calculate the time in minutes: tsafe=9.966×109.8 min≈1094.3 mint_{\text{safe}} = 9.966 \times 109.8\text{ min} \approx 1094.3\text{ min}.

  5. Convert the time to hours: tsafe=1094.3 min60 min/h≈18.2 hourst_{\text{safe}} = \frac{1094.3\text{ min}}{60\text{ min/h}} \approx 18.2\text{ hours}.

Final answer

18.2 hours18.2\text{ hours}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write down A(t)=A0(12)t/t1/2A(t) = A_0 \left(\frac{1}{2}\right)^{t/t_{1/2}} as your starting point whenever a problem specifies half-life.

  • Check that your model does not reach zero after two half-lives; after 2t1/22 t_{1/2}, exactly 25%25\% of the sample remains, not 0%0\%.

  • Practice using logarithms to solve for the exponent n=tt1/2n = \frac{t}{t_{1/2}} when the remaining fraction is not an exact integer power of two.

Lock it in

Similar question

01

Technetium-99m has a half-life of t1/2=6.00 hourst_{1/2} = 6.00\text{ hours}. A patient receives a dose, and hospital discharge requires the activity to drop below 6.25%6.25\% of the administered dose. Calculate the minimum waiting time in hours.

Answer

24.0 hours24.0\text{ hours}. Fraction remaining =0.0625=(1/2)4= 0.0625 = (1/2)^4. Thus, exactly n=4n = 4 half-lives are needed: t=4×6.00 h=24.0 hourst = 4 \times 6.00\text{ h} = 24.0\text{ hours}.

02

Carbon-11 is a PET imaging isotope with a half-life of t1/2=20.38 minutest_{1/2} = 20.38\text{ minutes}. How many hours must elapse before a sample's radioactivity drops to 0.500%0.500\% of its original level? Express the final answer to three significant figures.

Answer

2.60 hours2.60\text{ hours}. Set (0.5)n=0.00500  ⟹  n=ln⁡(0.00500)ln⁡(0.5)≈7.6439(0.5)^n = 0.00500 \implies n = \frac{\ln(0.00500)}{\ln(0.5)} \approx 7.6439 half-lives. Total elapsed time in minutes: t=7.6439×20.38 min≈155.78 mint = 7.6439 \times 20.38\text{ min} \approx 155.78\text{ min}. Convert to hours: t=155.7860≈2.60 hourst = \frac{155.78}{60} \approx 2.60\text{ hours}.

03

A research lab works with oxygen-15 (t1/2=122.2 secondst_{1/2} = 122.2\text{ seconds}). Safety guidelines require that an active exhaust plume decays to less than 1.00×10−41.00\times 10^{-4} of its initial emission activity before release. Find the minimum storage hold-up time in hours.

Answer

0.451 hours0.451\text{ hours}. Solve (0.5)n=1.00×10−4  ⟹  n=−4ln⁡(10)ln⁡(0.5)=4×2.30260.69315≈13.288(0.5)^n = 1.00 \times 10^{-4} \implies n = \frac{-4 \ln(10)}{\ln(0.5)} = \frac{4 \times 2.3026}{0.69315} \approx 13.288 half-lives. Elapsed time in seconds: t=13.288×122.2 s≈1623.8 st = 13.288 \times 122.2\text{ s} \approx 1623.8\text{ s}. Convert seconds to hours: t=1623.83600 s/h≈0.451 hourst = \frac{1623.8}{3600\text{ s/h}} \approx 0.451\text{ hours} (or 27.1 min27.1\text{ min}).

Loading workspace…