Resources
In an analytical physics laboratory session, a student uses a spectrometer equipped with a transmission diffraction grating to precisely standardize the emission lines of an unknown gas discharge tube. The grating specification states . (a) Calculate the grating slit spacing in micrometers (). (b) The student aligns the collimator and telescope and records the angular position of the first-order () spectral line at on the left side of the central axis and on the right side. Using the average diffraction angle , determine the calibrated wavelength of this spectral emission line in nanometers. (c) Determine the highest integer spectral order that can physically be observed for this specific wavelength with this grating.
Answer and steps
Final answer
(a) ; (b) ; (c)
Steps
Part (a): Grating Slit Spacing
The grating line density is given as . The slit spacing (grating spacing) is the reciprocal of the line density:
Substitute and convert millimeters to micrometers ():
Rounding to four significant figures gives:
Part (b): Calibrated Wavelength
First, determine the mean diffraction angle by averaging the left and right measurements to cancel out small zero-alignment errors of the spectrometer:
The transmission diffraction grating equation for normal incidence is:
For the first-order spectrum (), this simplifies to:
Evaluating :
(Note: Keeping full precision throughout yields to , which corresponds to the greenish-yellow emission region of the spectrum).
Part (c): Maximum Observable Spectral Order
Diffraction fringes can only be observed physically if the diffraction angle is strictly less than , which means :
Using the grating parameters:
Because the order of diffraction must be an integer, round down to the nearest whole number:
Thus, only the and orders can be formed on either side of the central maximum.
Typical errors
01 The student rounds the maximum order calculation up to the nearest integer instead of truncating down, resulting in an unobservable order m_max = 3.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
- Step 4Correct
You rounded up to , but the condition requires . Since must be an integer, you must truncate or round down to . An order of would require , which is impossible.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly inverted the grating line density to determine the slit spacing.
You averaged the left and right first-order angles to eliminate spectrometer alignment error.
You correctly applied the grating formula to solve for .
You correctly applied the physical bound to form the inequality .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeRounding to the nearest integer () rather than applying the floor function required by the inequality .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing standard numerical rounding rules with satisfying a physical inequality constraint (). For physical maxima bounded from above, the largest allowed integer must always be obtained by truncating (rounding down).
REASONING PATH
Your ACEpath teacher’s suggested approach- Truncation for Upper Bounds
When an integer order is constrained by , the maximum integer is .
Always drop the decimal portion rather than rounding to the nearest integer.
- Physical Sanity Check
Any physical diffraction order must satisfy .
Substitute your candidate back into to verify that the value does not exceed .
CORRECTED PATH
ACEpath Teacher's DemonstrationThe diffraction angle must satisfy , giving the inequality .
Because the spectral order must be an integer that satisfies this inequality, take the floor: .
Check: for , (observable); for , (unobservable).
02 The student incorrectly takes the difference between the two angle readings instead of averaging them, obtaining an erroneous diffraction angle and wavelength.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Because and are separate measurements of the first-order deviation on opposite sides of the central maximum, you need to take their arithmetic mean to find the true diffraction angle and eliminate spectrometer zero-offset errors, rather than subtracting them.
- Step 3Correct
Your formula setup was correct, but substituting the incorrect angle instead of led to an incorrect wavelength.
- Step 4Correct
Your method of taking the integer floor of was mathematically sound, but it inherited the incorrect wavelength value from part (b).
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the slit spacing from the line density .
You correctly set up the grating equation for .
You correctly applied the condition to find the maximum integer order.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou treated the two symmetric first-order angles and as two endpoints to be subtracted rather than two independent measurements of the same physical deflection.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConflating angular readings on opposite sides of the central beam ( and ) with a differential angle measurement. In spectrometer setups, each side measures the deflection angle from the center, so averaging them cancels small zero-alignment errors.
REASONING PATH
Your ACEpath teacher’s suggested approach- Spectrometer Angle Averaging
When measuring diffraction peaks at and orders, the average diffraction angle is .
Always verify whether angles represent absolute deviations from the center line (average them) or absolute scale dial readings (subtract to find , then divide by 2).
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the average diffraction angle: .
Compute the calibrated wavelength using the grating equation: .
Find the maximum observable order: , which rounds down to .
(a) ; (b) ; (c)
03 The student misinterprets lines per millimeter as slit spacing directly and computes d = 600 μm, propagating this incorrect scale throughout the solution.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You treated the line density directly as the slit separation. The slit spacing is the reciprocal of the line density: .
- Step 2
- Step 3Correct
Your formula and algebra were completely sound, but substituting the incorrect slit spacing carried the scale error into your wavelength.
- Step 4Correct
Your condition is mathematically correct. Because and were scaled by the same factor, their ratio canceled out the error, giving you the correct integer despite carrying affected values.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly averaged the two symmetric diffraction angle readings to determine .
You correctly recalled and manipulated the diffraction grating equation .
You applied the physical constraint to determine the maximum spectral order .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted instead of calculating .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused grating line density (number of slits per unit length) with the slit spacing (spatial distance between adjacent slits). The relationship is always inverse: .
REASONING PATH
Your ACEpath teacher’s suggested approach- Grating Spacing vs. Line Density
, where is the number of lines per unit length.
Before applying , check the units of . If is in lines/mm, compute .
- Physical Sanity Check for Visible Light
Visible light wavelengths range from to .
Compare your computed wavelength with the expected physical range; getting indicates that was miscalculated by several orders of magnitude.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the correct slit spacing from line density: .
Substitute into the grating equation for : .
(a) ; (b) ; (c)
Lock it in
Why must you always round down (truncate) when finding the maximum observable spectral order ?
Because must satisfy the inequality ; rounding up would require , which is physically impossible.
Similar question
A transmission grating has . Monochromatic light with is incident normally on the grating. Determine the highest integer spectral order that can be observed.
Answer
Grating spacing . The maximum order satisfies . Rounding down to the nearest integer gives .
A diffraction grating produces a second-order () maximum at an angle of for a light source. Determine the maximum integer diffraction order that can physically be produced by this setup.
Answer
From , we have . Because , the maximum observable integer order is .
Light containing two emission lines, and , is incident normally on a diffraction grating with slit spacing . Find the maximum visible order for each wavelength, and determine whether the highest order of overlaps with any order of .
Answer
For : . For : . For , (). For , gives (). Thus, appears at a larger angle than , meaning they do not directly overlap.