Resources
In a laboratory polarimetry experiment, a monochromatic sodium D-line source () produces an unpolarized beam that passes through a polarizing prism to establish vertical linear polarization. The polarized beam enters a sample tube containing an aqueous solution of D-glucose (specific rotation ) at an unknown concentration . An analyzing linear polarizer positioned after the sample tube is rotated to an angle relative to the vertical until the transmitted light is completely extinguished (zero intensity). The first extinction angle is observed at clockwise from the vertical. (a) Determine the net angle of optical rotation induced by the sugar solution in degrees. (b) Calculate the concentration of the D-glucose solution in .
Answer and steps
Final answer
(a) ; (b)
Steps
Part (a): Determining the Angle of Optical Rotation
- Condition for Extinction (Malus's Law): An analyzer transmits light with intensity governed by Malus's law: where is the angle between the plane of polarization of the incident beam and the transmission axis of the analyzer. Complete extinction () occurs when the transmission axis is strictly perpendicular to the light's polarization axis:
- Reference Extinction Angle: Before entering the optically active sample, the beam is linearly polarized along the vertical axis (). In the absence of an optically active medium, the analyzer achieves extinction at an angle perpendicular to the vertical:
- Net Optical Rotation: As the beam traverses the optically active D-glucose solution, its plane of polarization is rotated by an angle . Because D-glucose is dextrorotatory (), the rotation occurs in the clockwise direction. Consequently, the analyzer must be turned beyond by the exact amount to remain perpendicular to the rotated polarization plane: Solving for :
Common Pitfall: A frequent mistake is equating the extinction angle directly to the optical rotation angle (). Remember that an analyzer set to extinguish light measures the perpendicular axis (), not the polarization axis itself.
Part (b): Calculating the Concentration
- Biot's Law for Optical Activity: The relationship between the observed angle of rotation , the specific rotation , path length , and concentration is given by Biot's law:
-
Substitution of Values:
- Specific rotation
- Path length
- Optical rotation
Rearranging the formula to solve for concentration :
Typical errors
01 The student misinterprets the extinction angle of the analyzer as the direct transmission angle of the rotated polarization, setting α equal to 105.8°.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
The analyzer extinguishes light when its transmission axis is perpendicular () to the beam's plane of polarization. Because the unrotated beam was vertical (), extinction initially occurs at . The optical rotation is the rotation beyond this crossed position: .
- Step 2Correct
You stated Biot's law and substituted the path length and specific rotation correctly, but this step inherits the incorrect optical rotation angle from Step 1.
- Step 3Correct
Your arithmetic evaluation was carried out correctly based on your substituted value, but the final numerical value is incorrect due to the initial error in .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified Biot's law relating concentration, specific rotation, and path length.
You correctly isolated the concentration in the formula before substituting values.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakenone
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the analyzer's angle of minimum intensity (extinction) as the direct transmission angle of the polarized light, forgetting that an analyzer set for extinction is oriented perpendicular () to the polarization axis.
REASONING PATH
Your ACEpath teacher’s suggested approach- Condition for Extinction
By Malus's law (), zero intensity occurs when the analyzer axis is orthogonal to the polarization axis ().
Find the reference extinction angle without the sample (here from vertical) and compute .
CORRECTED PATH
ACEpath Teacher's DemonstrationDetermine the net rotation: .
Substitute into Biot's law: .
Calculate the concentration: .
(a) ; (b)
02 The student forgets to multiply by the path length l in Biot's law, calculating concentration as c = α / [α].
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You omitted the sample tube path length from the denominator of Biot's law .
- Step 3Correct
This value follows directly from the missing path length factor of in your formula.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly related the extinction angle of the analyzer to the optical rotation angle .
You accurately calculated .
You correctly substituted the specific rotation value into your expression.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou used an incomplete form of Biot's law () that assumes a unit path length () instead of accounting for the given sample tube.
REASONING PATH
Your ACEpath teacher’s suggested approach- Biot's Law Formula Check
Optical rotation is directly proportional to both path length and concentration: .
Always write the full formula and check that the units of cancel with the length unit in .
CORRECTED PATH
ACEpath Teacher's Demonstration(a) ; (b)
03 The student inappropriately converts the tube length from decimeters to centimeters, introducing an erroneous factor of 10 into Biot's law.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
The specific rotation is expressed in terms of decimeters (). Therefore, the sample tube length must remain in decimeters () rather than centimeters.
- Step 3Correct
Your arithmetic evaluation was carried out correctly from your substituted values, but the value is ten times too small due to the length unit mismatch in Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly related the extinction condition to the net rotation angle by subtracting from the analyzer angle.
You correctly stated Biot's law and rearranged it to solve for the concentration .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou converted the path length to centimeters () and substituted into the denominator instead of using .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking the explicit length unit embedded in the specific rotation , which by standard polarimetric definition uses decimeters () rather than centimeters ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Inspect the Units of Specific Rotation
Biot's law is . If is defined in , must be in and in .
Always cancel units explicitly before calculating: check that matches the term in .
CORRECTED PATH
ACEpath Teacher's DemonstrationSubstitute the path length directly in decimeters: .
Evaluate the concentration: .
(a) ; (b)
Lock it in
In a polarimeter, at what analyzer angle relative to the polarization axis does complete extinction occur?
(or ). Extinction means zero transmitted intensity, which Malus's law () yields only when the transmission axis is perpendicular to the light's polarization axis.
Similar question
A vertically polarized light beam passes through a polarimeter tube filled with an aqueous sucrose solution (). Complete extinction of the beam is observed when the analyzer is rotated to clockwise from the vertical. Find the optical rotation angle and the concentration of sucrose.
Answer
Optical rotation: . Concentration: .
A polarimetry setup uses an initially horizontally polarized beam ( from vertical). After passing through a cell containing a levorotatory substance () of concentration , determine: (a) the net optical rotation , and (b) the analyzer angle (measured clockwise from vertical) that produces complete extinction.
Answer
(a) . (b) With initial horizontal polarization (), the unrotated extinction position is along the vertical ( or ). A rotation of (counterclockwise) places extinction at (or / clockwise from vertical).
In a dual-mode polarimeter test, a sample solution of unknown concentration produces maximum transmission at an analyzer angle of clockwise from vertical. (a) At what analyzer angle will the first extinction occur? (b) If the specific rotation is and the cell length is , find the solution concentration .
Answer
(a) Maximum transmission occurs parallel to the rotated polarization axis, so . Extinction is perpendicular to this: . (b) Using Biot's law: .