Resources

In a laboratory polarimetry experiment, a monochromatic sodium D-line source (λ=589.3 nm\lambda = 589.3\text{ nm}) produces an unpolarized beam that passes through a polarizing prism to establish vertical linear polarization. The polarized beam enters a 2.00 dm2.00\text{ dm} sample tube containing an aqueous solution of D-glucose (specific rotation [α]D20=+52.7∘ dm−1⋅(g/cm3)−1[\alpha]_D^{20} = +52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1}) at an unknown concentration cc. An analyzing linear polarizer positioned after the sample tube is rotated to an angle ϕ\phi relative to the vertical until the transmitted light is completely extinguished (zero intensity). The first extinction angle is observed at ϕ=105.8∘\phi = 105.8^\circ clockwise from the vertical. (a) Determine the net angle of optical rotation α\alpha induced by the sugar solution in degrees. (b) Calculate the concentration cc of the D-glucose solution in g/cm3\text{g/cm}^3.

Answer and steps

Final answer

(a) α=+15.8∘\alpha = +15.8^\circ; (b) c=0.150 g/cm3c = 0.150\text{ g/cm}^3

Steps

Part (a): Determining the Angle of Optical Rotation α\alpha

  1. Condition for Extinction (Malus's Law): An analyzer transmits light with intensity governed by Malus's law: I=I0cos⁡2θI = I_0 \cos^2\theta where θ\theta is the angle between the plane of polarization of the incident beam and the transmission axis of the analyzer. Complete extinction (I=0I = 0) occurs when the transmission axis is strictly perpendicular to the light's polarization axis: θ=90∘\theta = 90^\circ
  2. Reference Extinction Angle: Before entering the optically active sample, the beam is linearly polarized along the vertical axis (0∘0^\circ). In the absence of an optically active medium, the analyzer achieves extinction at an angle perpendicular to the vertical: ϕ0=90.0∘\phi_0 = 90.0^\circ
  3. Net Optical Rotation: As the beam traverses the optically active D-glucose solution, its plane of polarization is rotated by an angle α\alpha. Because D-glucose is dextrorotatory ([α]>0[\alpha] > 0), the rotation occurs in the clockwise direction. Consequently, the analyzer must be turned beyond 90.0∘90.0^\circ by the exact amount α\alpha to remain perpendicular to the rotated polarization plane: ϕ=90.0∘+α\phi = 90.0^\circ + \alpha Solving for α\alpha: α=ϕ−90.0∘=105.8∘−90.0∘=+15.8∘\alpha = \phi - 90.0^\circ = 105.8^\circ - 90.0^\circ = +15.8^\circ

Common Pitfall: A frequent mistake is equating the extinction angle directly to the optical rotation angle (α≠ϕ\alpha \neq \phi). Remember that an analyzer set to extinguish light measures the perpendicular axis (90∘+α90^\circ + \alpha), not the polarization axis itself.


Part (b): Calculating the Concentration cc

  1. Biot's Law for Optical Activity: The relationship between the observed angle of rotation α\alpha, the specific rotation [α][\alpha], path length ll, and concentration cc is given by Biot's law: α=[α]D20⋅l⋅c\alpha = [\alpha]_D^{20} \cdot l \cdot c
  2. Substitution of Values:

    • Specific rotation [α]D20=+52.7∘ dm−1⋅(g/cm3)−1[\alpha]_D^{20} = +52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1}
    • Path length l=2.00 dml = 2.00\text{ dm}
    • Optical rotation α=+15.8∘\alpha = +15.8^\circ

    Rearranging the formula to solve for concentration cc: c=α[α]D20⋅lc = \frac{\alpha}{[\alpha]_D^{20} \cdot l} c=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dmc = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}} c=15.8105.4 g/cm3≈0.150 g/cm3c = \frac{15.8}{105.4}\text{ g/cm}^3 \approx 0.150\text{ g/cm}^3

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student misinterprets the extinction angle of the analyzer as the direct transmission angle of the rotated polarization, setting α equal to 105.8°.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    α=105.8∘\alpha = 105.8^\circ

    Correct

    α=ϕ−90.0∘=105.8∘−90.0∘=+15.8∘\alpha = \phi - 90.0^\circ = 105.8^\circ - 90.0^\circ = +15.8^\circ

    The analyzer extinguishes light when its transmission axis is perpendicular (90∘90^\circ) to the beam's plane of polarization. Because the unrotated beam was vertical (0∘0^\circ), extinction initially occurs at 90.0∘90.0^\circ. The optical rotation is the rotation beyond this crossed position: α=105.8∘−90.0∘=+15.8∘\alpha = 105.8^\circ - 90.0^\circ = +15.8^\circ.

  2. Step 2

    c=α[α]⋅l  ⟹  c=105.8∘(52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dm)c = \frac{\alpha}{[\alpha] \cdot l} \implies c = \frac{105.8^\circ}{(52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm})}

    Correct

    c=α[α]D20⋅l=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dmc = \frac{\alpha}{[\alpha]_D^{20} \cdot l} = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}}

    You stated Biot's law and substituted the path length and specific rotation correctly, but this step inherits the incorrect optical rotation angle from Step 1.

  3. Step 3

    c=1.00 g/cm3c = 1.00\text{ g/cm}^3

    Correct

    c=15.8105.4 g/cm3≈0.150 g/cm3c = \frac{15.8}{105.4}\text{ g/cm}^3 \approx 0.150\text{ g/cm}^3

    Your arithmetic evaluation was carried out correctly based on your substituted value, but the final numerical value is incorrect due to the initial error in α\alpha.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified Biot's law relating concentration, specific rotation, and path length.

You correctly isolated the concentration cc in the formula before substituting values.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Extinction angle vs. rotation angle confusion

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the analyzer's angle of minimum intensity (extinction) as the direct transmission angle of the polarized light, forgetting that an analyzer set for extinction is oriented perpendicular (90∘90^\circ) to the polarization axis.

REASONING PATH
Your ACEpath teacher’s suggested approach
Condition for Extinction
  • By Malus's law (I=I0cos⁡2θI = I_0 \cos^2\theta), zero intensity occurs when the analyzer axis is orthogonal to the polarization axis (θ=90∘\theta = 90^\circ).

  • Find the reference extinction angle without the sample (here 90∘90^\circ from vertical) and compute α=ϕ−90∘\alpha = \phi - 90^\circ.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Determine the net rotation: α=ϕ−90.0∘=105.8∘−90.0∘=+15.8∘\alpha = \phi - 90.0^\circ = 105.8^\circ - 90.0^\circ = +15.8^\circ.

  2. Substitute α=15.8∘\alpha = 15.8^\circ into Biot's law: c=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dmc = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}}.

  3. Calculate the concentration: c=15.8105.4 g/cm3≈0.150 g/cm3c = \frac{15.8}{105.4}\text{ g/cm}^3 \approx 0.150\text{ g/cm}^3.

Final answer

(a) α=+15.8∘\alpha = +15.8^\circ; (b) c=0.150 g/cm3c = 0.150\text{ g/cm}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch the transmission axes of both polarizers before and after optical rotation to visualize why the extinction angle has a 90∘90^\circ baseline.

  • Practice distinguishing whether a polarimetry problem specifies the maximum transmission orientation (parallel) or the extinction orientation (perpendicular).

OverviewACEpath Teacher's Diagnosis

02 The student forgets to multiply by the path length l in Biot's law, calculating concentration as c = α / [α].

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    α=105.8∘−90.0∘=15.8∘\alpha = 105.8^\circ - 90.0^\circ = 15.8^\circ

  2. Step 2

    c=α[α]  ⟹  c=15.8∘52.7∘ dm−1⋅(g/cm3)−1c = \frac{\alpha}{[\alpha]} \implies c = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1}}

    Correct

    c=α[α]⋅l=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dmc = \frac{\alpha}{[\alpha] \cdot l} = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}}

    You omitted the sample tube path length l=2.00 dml = 2.00\text{ dm} from the denominator of Biot's law α=[α]⋅l⋅c\alpha = [\alpha]\cdot l \cdot c.

  3. Step 3

    c=0.300 g/cm3c = 0.300\text{ g/cm}^3

    Correct

    c=0.150 g/cm3c = 0.150\text{ g/cm}^3

    This value follows directly from the missing path length factor of 2.00 dm2.00\text{ dm} in your formula.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly related the extinction angle of the analyzer to the optical rotation angle α\alpha.

You accurately calculated α=15.8∘\alpha = 15.8^\circ.

You correctly substituted the specific rotation value into your expression.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of path length in Biot's law

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You used an incomplete form of Biot's law (c=α[α]c = \frac{\alpha}{[\alpha]}) that assumes a unit path length (l=1 dml = 1\text{ dm}) instead of accounting for the given 2.00 dm2.00\text{ dm} sample tube.

REASONING PATH
Your ACEpath teacher’s suggested approach
Biot's Law Formula Check
  • Optical rotation is directly proportional to both path length and concentration: α=[α]⋅l⋅c\alpha = [\alpha]\cdot l \cdot c.

  • Always write the full formula α=[α]DT⋅l⋅c\alpha = [\alpha]_D^T \cdot l \cdot c and check that the units of ll cancel with the length unit in [α][\alpha].

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. c=α[α]D20⋅lc = \frac{\alpha}{[\alpha]_D^{20} \cdot l}

  2. c=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dm=15.8105.4 g/cm3c = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}} = \frac{15.8}{105.4}\text{ g/cm}^3

  3. c≈0.150 g/cm3c \approx 0.150\text{ g/cm}^3

Final answer

(a) α=+15.8∘\alpha = +15.8^\circ; (b) c=0.150 g/cm3c = 0.150\text{ g/cm}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Review Biot's law to ensure you include both concentration and path length every time.

  • Perform dimensional analysis on your algebraic formula before substituting numbers to verify that all unwanted units cancel.

OverviewACEpath Teacher's Diagnosis

03 The student inappropriately converts the tube length from decimeters to centimeters, introducing an erroneous factor of 10 into Biot's law.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    α=105.8∘−90.0∘=15.8∘\alpha = 105.8^\circ - 90.0^\circ = 15.8^\circ

  2. Step 2

    l=2.00 dm=20.0 cm  ⟹  c=α[α]⋅l=15.8∘52.7⋅20.0l = 2.00\text{ dm} = 20.0\text{ cm} \implies c = \frac{\alpha}{[\alpha] \cdot l} = \frac{15.8^\circ}{52.7 \cdot 20.0}

    Correct

    c=α[α]D20⋅l=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dmc = \frac{\alpha}{[\alpha]_D^{20} \cdot l} = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}}

    The specific rotation [α]D20[\alpha]_D^{20} is expressed in terms of decimeters (dm−1\text{dm}^{-1}). Therefore, the sample tube length ll must remain in decimeters (l=2.00 dml = 2.00\text{ dm}) rather than centimeters.

  3. Step 3

    c=0.0150 g/cm3c = 0.0150\text{ g/cm}^3

    Correct

    c=15.8105.4 g/cm3≈0.150 g/cm3c = \frac{15.8}{105.4}\text{ g/cm}^3 \approx 0.150\text{ g/cm}^3

    Your arithmetic evaluation was carried out correctly from your substituted values, but the value is ten times too small due to the length unit mismatch in Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly related the extinction condition to the net rotation angle by subtracting 90.0∘90.0^\circ from the analyzer angle.

You correctly stated Biot's law and rearranged it to solve for the concentration cc.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Mismatch in Biot's Law

You converted the path length ll to centimeters (20.0 cm20.0\text{ cm}) and substituted 20.020.0 into the denominator instead of using 2.00 dm2.00\text{ dm}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking the explicit length unit embedded in the specific rotation [α][\alpha], which by standard polarimetric definition uses decimeters (dm\text{dm}) rather than centimeters (cm\text{cm}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Inspect the Units of Specific Rotation
  • Biot's law is α=[α]⋅l⋅c\alpha = [\alpha] \cdot l \cdot c. If [α][\alpha] is defined in ∘⋅dm−1⋅(g/cm3)−1^\circ\cdot\text{dm}^{-1}\cdot(\text{g/cm}^3)^{-1}, ll must be in dm\text{dm} and cc in g/cm3\text{g/cm}^3.

  • Always cancel units explicitly before calculating: check that [l]=dm[l] = \text{dm} matches the dm−1\text{dm}^{-1} term in [α][\alpha].

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Substitute the path length directly in decimeters: l=2.00 dml = 2.00\text{ dm}.

  2. Evaluate the concentration: c=15.8∘52.7∘ dm−1⋅(g/cm3)−1⋅2.00 dm=15.8105.4 g/cm3=0.150 g/cm3c = \frac{15.8^\circ}{52.7^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.00\text{ dm}} = \frac{15.8}{105.4}\text{ g/cm}^3 = 0.150\text{ g/cm}^3.

Final answer

(a) α=+15.8∘\alpha = +15.8^\circ; (b) c=0.150 g/cm3c = 0.150\text{ g/cm}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the standard definition of specific rotation [α][\alpha] and note why path length is conventionally measured in decimeters (1 dm=10 cm1\text{ dm} = 10\text{ cm}).

  • Practice checking unit dimensions across all factors in Biot's law before calculating numerical answers.

Lock it in

Similar question

01

A vertically polarized light beam passes through a 1.00 dm1.00\text{ dm} polarimeter tube filled with an aqueous sucrose solution ([α]D20=+66.5∘ dm−1⋅(g/cm3)−1[\alpha]_D^{20} = +66.5^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1}). Complete extinction of the beam is observed when the analyzer is rotated to 96.65∘96.65^\circ clockwise from the vertical. Find the optical rotation angle α\alpha and the concentration cc of sucrose.

Answer

Optical rotation: α=96.65∘−90.00∘=+6.65∘\alpha = 96.65^\circ - 90.00^\circ = +6.65^\circ. Concentration: c=α[α]D20⋅l=6.65∘66.5∘ dm−1⋅(g/cm3)−1⋅1.00 dm=0.100 g/cm3c = \frac{\alpha}{[\alpha]_D^{20} \cdot l} = \frac{6.65^\circ}{66.5^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 1.00\text{ dm}} = 0.100\text{ g/cm}^3.

02

A polarimetry setup uses an initially horizontally polarized beam (90∘90^\circ from vertical). After passing through a 2.00 dm2.00\text{ dm} cell containing a levorotatory substance ([α]D20=−25.0∘ dm−1⋅(g/cm3)−1[\alpha]_D^{20} = -25.0^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1}) of concentration 0.200 g/cm30.200\text{ g/cm}^3, determine: (a) the net optical rotation α\alpha, and (b) the analyzer angle ϕ\phi (measured clockwise from vertical) that produces complete extinction.

Answer

(a) α=[α]⋅l⋅c=(−25.0∘ dm−1⋅(g/cm3)−1)(2.00 dm)(0.200 g/cm3)=−10.0∘\alpha = [\alpha] \cdot l \cdot c = (-25.0^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1})(2.00\text{ dm})(0.200\text{ g/cm}^3) = -10.0^\circ. (b) With initial horizontal polarization (90∘90^\circ), the unrotated extinction position is along the vertical (0∘0^\circ or 180∘180^\circ). A rotation of −10.0∘-10.0^\circ (counterclockwise) places extinction at −10.0∘-10.0^\circ (or 350.0∘350.0^\circ / 170.0∘170.0^\circ clockwise from vertical).

03

In a dual-mode polarimeter test, a sample solution of unknown concentration produces maximum transmission at an analyzer angle of θmax=22.4∘\theta_{\text{max}} = 22.4^\circ clockwise from vertical. (a) At what analyzer angle ϕext\phi_{\text{ext}} will the first extinction occur? (b) If the specific rotation is +44.8∘ dm−1⋅(g/cm3)−1+44.8^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} and the cell length is 2.50 dm2.50\text{ dm}, find the solution concentration cc.

Answer

(a) Maximum transmission occurs parallel to the rotated polarization axis, so α=22.4∘\alpha = 22.4^\circ. Extinction is perpendicular to this: ϕext=α+90.0∘=112.4∘\phi_{\text{ext}} = \alpha + 90.0^\circ = 112.4^\circ. (b) Using Biot's law: c=α[α]⋅l=22.4∘44.8∘ dm−1⋅(g/cm3)−1⋅2.50 dm=22.4112.0=0.200 g/cm3c = \frac{\alpha}{[\alpha] \cdot l} = \frac{22.4^\circ}{44.8^\circ\text{ dm}^{-1}\cdot(\text{g/cm}^3)^{-1} \cdot 2.50\text{ dm}} = \frac{22.4}{112.0} = 0.200\text{ g/cm}^3.

Loading workspace…