Resources
An electric DC motor is designed to drive a laboratory pump with a peak operational torque of . The motor's armature consists of a flat circular loop assembly with and a radius of rotating within a permanent magnetic field of . Working backwards from the torque specification, calculate the required armature current that must be supplied by the DC source to deliver this peak torque.
Answer and steps
Final answer
Steps
Understand the Motor's Torque Formula
An electric DC motor operates on the principle of magnetic torque exerted on a current-carrying loop. When a coil containing turns, each of area and carrying current , is placed in a uniform magnetic field , the magnetic torque exerted on it is given by:
where is the angle between the magnetic field vector and the normal (perpendicular) vector to the plane of the coil.
The peak operational torque occurs when the plane of the coil is parallel to the magnetic field lines (, so ):
Calculate the Cross-Sectional Area of the Coil
The armature coil is circular with a radius . Its cross-sectional area is:
Solve for the Required Current
Rearranging the peak torque formula to solve for the armature current :
Substitute the given values into the expression:
Evaluating the denominator:
Thus, the required current is:
Summary & Common Pitfalls
- Angle Confusion: Ensure is measured between the magnetic field and the coil's normal vector. When the coil's flat face is parallel to the field, the normal is perpendicular (), yielding maximum torque.
- Unit Conversion: Always convert the radius from centimeters to meters () before squaring to avoid errors by factors of .
Typical errors
01 The student forgets to convert the radius from centimeters to meters, resulting in an area that is too small by a factor of 10⁴ and a current that is 10⁴ times too large.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You substituted the radius directly as without converting it to meters (). Because , substituting directly gave an area of instead of .
- Step 3Correct
Your algebraic rearrangement for and your substitutions for , , and are completely correct, but the calculation carries forward your incorrect area value from Step 2.
- Step 4Correct
Your arithmetic matches your substituted numbers, but the result is off by a factor of due to the unit conversion error in Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified that the peak torque occurs when , giving .
You correctly rearranged the torque formula algebraically to isolate the current .
You carried out the multi-factor division accurately based on the numbers you substituted.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou entered the radius as instead of into the area formula .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou did not convert the linear dimension from centimeters to standard SI units (meters) before squaring. Squaring a dimension in centimeters yields square centimeters (), which differs from square meters () by a factor of .
REASONING PATH
Your ACEpath teacher’s suggested approach- SI Unit Consistency
In standard electromagnetism formulas (where is in teslas and is in ), all lengths must be in meters () and all areas in square meters ().
Always convert non-standard units (such as or ) to meters before squaring or substituting into physical formulas.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert the radius to meters: .
Calculate the coil's cross-sectional area: .
Substitute into the rearranged current equation: .
02 The student uses the circumference formula 2*π*r instead of the area formula π*r² for the loop, calculating an incorrect current of approximately 40.2 A.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You used the circle circumference formula rather than the cross-sectional area formula .
- Step 3Correct
This step carries forward the incorrect loop area value. In addition, evaluating gives approximately , so an additional scale factor error occurred during evaluation.
WHAT YOU DID WELL
Compliments from Your TeacherYou identified the peak motor torque equation where .
You algebraically rearranged the equation to solve for the target variable .
You converted the radius from centimeters to meters before using it.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the one-dimensional perimeter formula where the two-dimensional loop area was required.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the linear boundary metric (circumference) of a loop with its enclosed planar surface area when calculating magnetic dipole moment or magnetic torque.
REASONING PATH
Your ACEpath teacher’s suggested approach- Check Dimensional Consistency of Area
Area must always have dimensions of length squared (, such as ).
Ensure the geometric formula squares the linear dimension (), confirming for a circle, whereas has units of meters ().
- Re-evaluate Denominator Products Carefully
Grouping multiple terms in the denominator requires either calculating the denominator first or using parentheses on a calculator: .
Compute as an intermediate value with units of before dividing into .
CORRECTED PATH
ACEpath Teacher's DemonstrationDenominator
03 The student forgets to square the radius when calculating the area, computing π * r instead of π * r², which yields a current of 0.0805 A.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You calculated instead of squaring the radius (), which overestimated the coil's cross-sectional area by a factor of nearly .
- Step 3Correct
Your algebraic rearrangement and arithmetic were carried out correctly, but the final current value was inaccurate due to the incorrect area from step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified the peak torque formula .
You converted the radius from centimeters to meters ().
You correctly rearranged the torque equation to isolate the current .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou omitted the square exponent on the radius when calculating the cross-sectional area of the circular loop.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing linear dimensions with two-dimensional area formulas leads to dropping the exponent in , which causes a significant dimensional and numerical error.
REASONING PATH
Your ACEpath teacher’s suggested approach- Dimensional Check for Area
Area has units of , which requires multiplying two length dimensions or squaring a length.
Always verify that your formula includes () rather than when calculating cross-sectional area.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate .
Substitute into the current equation: .
Evaluate the denominator: .
Compute the required current: .
Lock it in
How do you convert an area calculated in to the SI unit ?
Multiply by (since , so ). Always convert lengths to meters before squaring.
Similar question
A circular loop with radius has and carries a current of . Calculate the magnetic dipole moment of the loop in standard SI units.
Answer
. Steps: Convert radius ; area ; compute .
A rectangular coil of dimensions contains and is placed in a uniform magnetic field . If the coil experiences a peak torque of , find the required current .
Answer
. Steps: Convert dimensions to meters: , so . Use .
A small DC motor operates with an armature coil of and circular radius in a field . The motor source is limited to a maximum current of . What is the maximum torque the motor can generate?
Answer
. Steps: ; ; .