Resources

A surveyor uses an aluminum measuring tape that is precisely calibrated to be L0=50.000 mL_0 = 50.000\text{ m} at Tcal=20.0∘CT_{\text{cal}} = 20.0^\circ\text{C}. On a cold afternoon at T=−8.0∘CT = -8.0^\circ\text{C}, the surveyor uses this tape to measure the distance between two fixed boundary stakes and records a nominal tape reading of Lread=50.000 mL_{\text{read}} = 50.000\text{ m}. Given that the coefficient of linear expansion for aluminum is α=2.40×10−5 ∘C−1\alpha = 2.40 \times 10^{-5}\text{ }^\circ\text{C}^{-1}, calculate the fractional change in length ΔLL0\frac{\Delta L}{L_0} of the tape and determine the true physical distance LtrueL_{\text{true}} between the stakes.

Answer and steps

Final answer

ΔLL0=−6.72×10−4\frac{\Delta L}{L_0} = -6.72 \times 10^{-4} (or −0.0672%-0.0672\%); Ltrue=49.966 mL_{\text{true}} = 49.966\text{ m}

Steps

01

Identify the Temperature Change and Expansion Formula

Thermal linear expansion or contraction is governed by the relation: ΔL=L0αΔT\Delta L = L_0 \alpha \Delta T

where:

  • L0=50.000 mL_0 = 50.000\text{ m} is the nominal calibrated length at Tcal=20.0∘CT_{\text{cal}} = 20.0^\circ\text{C}
  • T=−8.0∘CT = -8.0^\circ\text{C} is the measurement temperature
  • α=2.40×10−5 ∘C−1\alpha = 2.40 \times 10^{-5}\text{ }^\circ\text{C}^{-1} is the linear expansion coefficient of aluminum

The change in temperature ΔT\Delta T from calibration is: ΔT=T−Tcal=−8.0∘C−20.0∘C=−28.0∘C\Delta T = T - T_{\text{cal}} = -8.0^\circ\text{C} - 20.0^\circ\text{C} = -28.0^\circ\text{C}


02

Calculate the Fractional Change in Length

The fractional change in length ΔLL0\frac{\Delta L}{L_0} represents the proportional shrinking of the tape: ΔLL0=αΔT\frac{\Delta L}{L_0} = \alpha \Delta T

Substitute the numerical values: ΔLL0=(2.40×10−5 ∘C−1)(−28.0∘C)=−6.72×10−4\frac{\Delta L}{L_0} = (2.40 \times 10^{-5}\text{ }^\circ\text{C}^{-1})(-28.0^\circ\text{C}) = -6.72 \times 10^{-4}

Expressed as a percentage: −6.72×10−4×100%=−0.0672%-6.72 \times 10^{-4} \times 100\% = -0.0672\%

The negative sign confirms that the aluminum tape has contracted due to the drop in temperature.


03

Determine the True Physical Distance

Because the tape has contracted, every meter mark is physically closer together than it was at 20.0∘C20.0^\circ\text{C}. The recorded nominal reading spans the entire 50.000 m50.000\text{ m} calibration distance on the tape, so the actual physical distance LtrueL_{\text{true}} between the stakes corresponds to the cold, contracted physical length of that tape segment:

Ltrue=L0+ΔL=L0(1+ΔLL0)L_{\text{true}} = L_0 + \Delta L = L_0\left(1 + \frac{\Delta L}{L_0}\right)

Calculate the physical shrinkage ΔL\Delta L: ΔL=50.000 m⋅(−6.72×10−4)=−0.0336 m\Delta L = 50.000\text{ m} \cdot (-6.72 \times 10^{-4}) = -0.0336\text{ m}

Substitute back to find the true distance: Ltrue=50.000 m−0.0336 m=49.9664 m≈49.966 mL_{\text{true}} = 50.000\text{ m} - 0.0336\text{ m} = 49.9664\text{ m} \approx 49.966\text{ m}

Common Pitfall: A frequent mistake is to assume that because a measuring tool shrinks, the measured object must be longer than the reading. While measuring a fixed length with shrunken unit tick marks yields a larger numerical reading, here the reading was fixed at the nominal length (50.000 m50.000\text{ m}). Therefore, the physical span of the tape itself defines the distance between the stakes, which is shorter than 50.000 m50.000\text{ m}.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student calculates the temperature change as positive by subtracting the lower temperature from the higher temperature, concluding that the tape expanded rather than contracted.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ΔT=20.0∘C−(−8.0∘C)=28.0∘C\Delta T = 20.0^\circ\text{C} - (-8.0^\circ\text{C}) = 28.0^\circ\text{C}

    Correct

    ΔT=T−Tcal=−8.0∘C−20.0∘C=−28.0∘C\Delta T = T - T_{\text{cal}} = -8.0^\circ\text{C} - 20.0^\circ\text{C} = -28.0^\circ\text{C}

    You calculated ΔT\Delta T as Tcal−TT_{\text{cal}} - T rather than Tfinal−TinitialT_{\text{final}} - T_{\text{initial}}. Because the environment cooled down to −8.0∘C-8.0^\circ\text{C}, the temperature change must be negative.

  2. Step 2

    ΔLL0=αΔT=(2.40×10−5)(28.0)=6.72×10−4\frac{\Delta L}{L_0} = \alpha \Delta T = (2.40 \times 10^{-5})(28.0) = 6.72 \times 10^{-4}

    Correct

    ΔLL0=αΔT=(2.40×10−5 ∘C−1)(−28.0∘C)=−6.72×10−4\frac{\Delta L}{L_0} = \alpha \Delta T = (2.40 \times 10^{-5}\text{ }^\circ\text{C}^{-1})(-28.0^\circ\text{C}) = -6.72 \times 10^{-4}

    You correctly multiplied α\alpha by ΔT\Delta T, but the positive sign from Step 1 carried through, indicating expansion instead of contraction.

  3. Step 3

    ΔL=L0×(ΔLL0)=(50.000 m)(6.72×10−4)=0.0336 m\Delta L = L_0 \times \left(\frac{\Delta L}{L_0}\right) = (50.000\text{ m})(6.72 \times 10^{-4}) = 0.0336\text{ m}

    Correct

    ΔL=L0(ΔLL0)=(50.000 m)(−6.72×10−4)=−0.0336 m\Delta L = L_0 \left(\frac{\Delta L}{L_0}\right) = (50.000\text{ m})(-6.72 \times 10^{-4}) = -0.0336\text{ m}

    Your relationship between fractional change and absolute change is correct, but ΔL\Delta L should be negative.

  4. Step 4

    Ltrue=50.000 m+0.0336 m=50.034 mL_{\text{true}} = 50.000\text{ m} + 0.0336\text{ m} = 50.034\text{ m}

    Correct

    Ltrue=L0+ΔL=50.000 m+(−0.0336 m)=49.966 mL_{\text{true}} = L_0 + \Delta L = 50.000\text{ m} + (-0.0336\text{ m}) = 49.966\text{ m}

    You correctly added the change in length to the nominal tape length, but adding a positive ΔL\Delta L resulted in a tape that is longer than calibrated rather than shorter.

WHAT YOU DID WELL
Compliments from Your Teacher

You selected the correct formula for thermal linear expansion, ΔL=L0αΔT\Delta L = L_0 \alpha \Delta T.

You correctly related the fractional change ΔLL0\frac{\Delta L}{L_0} to the total change ΔL\Delta L.

You performed all numerical multiplication and addition with clean precision.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign error in temperature difference

You set up the temperature change by subtracting the negative cold temperature from the positive warm temperature to keep the number positive, reversing the standard final minus initial order.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating ΔT\Delta T as an unsigned magnitude rather than a signed change (Tfinal−TinitialT_{\text{final}} - T_{\text{initial}}) leads to predicting expansion whenever a negative temperature is involved.

REASONING PATH
Your ACEpath teacher’s suggested approach
Define Change as Final Minus Initial
  • In physics, ΔX=Xfinal−Xinitial\Delta X = X_{\text{final}} - X_{\text{initial}} always. A cooling process must yield ΔT<0\Delta T < 0.

  • Label Tinitial=Tcal=20.0∘CT_{\text{initial}} = T_{\text{cal}} = 20.0^\circ\text{C} and Tfinal=−8.0∘CT_{\text{final}} = -8.0^\circ\text{C} explicitly before writing ΔT\Delta T.

Physical Reality Check
  • Solid materials contract when cooled and expand when heated (for positive α\alpha).

  • Check that cooling yields a negative ΔL\Delta L, meaning the physical tape length is shorter than its nominal 50.000 m50.000\text{ m} mark.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the signed temperature change: ΔT=Tfinal−Tinitial=−8.0∘C−20.0∘C=−28.0∘C\Delta T = T_{\text{final}} - T_{\text{initial}} = -8.0^\circ\text{C} - 20.0^\circ\text{C} = -28.0^\circ\text{C}.

  2. Compute the fractional change in length: ΔLL0=αΔT=(2.40×10−5 ∘C−1)(−28.0∘C)=−6.72×10−4\frac{\Delta L}{L_0} = \alpha \Delta T = (2.40 \times 10^{-5}\text{ }^\circ\text{C}^{-1})(-28.0^\circ\text{C}) = -6.72 \times 10^{-4}.

  3. Determine the physical contraction of the 50.000 m50.000\text{ m} tape segment: ΔL=L0(ΔLL0)=(50.000 m)(−6.72×10−4)=−0.0336 m\Delta L = L_0 \left(\frac{\Delta L}{L_0}\right) = (50.000\text{ m})(-6.72 \times 10^{-4}) = -0.0336\text{ m}.

  4. Calculate the true physical distance between the stakes: Ltrue=L0+ΔL=50.000 m−0.0336 m=49.966 mL_{\text{true}} = L_0 + \Delta L = 50.000\text{ m} - 0.0336\text{ m} = 49.966\text{ m}.

Final answer

ΔLL0=−6.72×10−4\frac{\Delta L}{L_0} = -6.72 \times 10^{-4} (or −0.0672%-0.0672\%); Ltrue=49.966 mL_{\text{true}} = 49.966\text{ m}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice writing Tf−TiT_f - T_i explicitly whenever temperature drops into negative values.

  • Perform a physical sanity check at the end: did the object get hotter (longer) or colder (shorter)?

OverviewACEpath Teacher's Diagnosis

02 The student correctly finds that the tape contracts but mistakenly believes that a contracted tape reads larger and therefore adds the contraction instead of subtracting it to find the true distance.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    ΔT=−8.0∘C−20.0∘C=−28.0∘C  ⟹  ΔLL0=αΔT=(2.40×10−5)(−28.0)=−6.72×10−4\Delta T = -8.0^\circ\text{C} - 20.0^\circ\text{C} = -28.0^\circ\text{C} \implies \frac{\Delta L}{L_0} = \alpha \Delta T = (2.40 \times 10^{-5})(-28.0) = -6.72 \times 10^{-4}

  2. Step 2

    ∣ΔL∣=(50.000 m)(6.72×10−4)=0.0336 m|\Delta L| = (50.000\text{ m})(6.72 \times 10^{-4}) = 0.0336\text{ m}

  3. Step 3

    Ltrue=50.000 m+0.0336 m=50.034 mL_{\text{true}} = 50.000\text{ m} + 0.0336\text{ m} = 50.034\text{ m}

    Correct

    Ltrue=L0+ΔL=50.000 m−0.0336 m=49.966 mL_{\text{true}} = L_0 + \Delta L = 50.000\text{ m} - 0.0336\text{ m} = 49.966\text{ m}

    Because the tape contracted in the cold, the physical length corresponding to the 50.000 m50.000\text{ m} mark is shorter than nominal, so you need to subtract the contraction: Ltrue=50.000 m−0.0336 m=49.966 mL_{\text{true}} = 50.000\text{ m} - 0.0336\text{ m} = 49.966\text{ m}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the temperature change ΔT=−28.0∘C\Delta T = -28.0^\circ\text{C}.

You correctly applied the linear thermal expansion formula to find the fractional change ΔLL0=−6.72×10−4\frac{\Delta L}{L_0} = -6.72 \times 10^{-4}.

You correctly computed the magnitude of contraction ∣ΔL∣=0.0336 m|\Delta L| = 0.0336\text{ m}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign error in thermal contraction calibration

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You mistakenly added the contraction instead of subtracting it when converting the nominal reading of a contracted tape to the true physical distance. When a measuring tape gets colder, it shrinks, meaning the physical span between the zero mark and the 50.000 m50.000\text{ m} mark is less than 50.000 m50.000\text{ m}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Relating Tape Shrinkage to Distance
  • Ltrue=Lread(1+αΔT)L_{\text{true}} = L_{\text{read}}(1 + \alpha \Delta T)

  • When ΔT<0\Delta T < 0, αΔT\alpha \Delta T is negative, so the true physical distance corresponding to a given reading is shorter than the reading on the tape.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recognize that the tape contracts at cold temperatures: ΔL=−0.0336 m\Delta L = -0.0336\text{ m}.

  2. Compute true length: Ltrue=L0+ΔL=50.000 m+(−0.0336 m)=49.9664 mL_{\text{true}} = L_0 + \Delta L = 50.000\text{ m} + (-0.0336\text{ m}) = 49.9664\text{ m}.

Final answer

Ltrue=49.966 mL_{\text{true}} = 49.966\text{ m}

NEXT STEPS
Final Takeaways from Your Teacher
  • Remember the physical picture: cold materials contract, so a 50 m50\text{ m} cold tape actually spans less than 50 m50\text{ m} in space.

  • Always carry the algebraic negative sign directly from ΔT\Delta T through Ltrue=L0(1+αΔT)L_{\text{true}} = L_0(1 + \alpha \Delta T) instead of working with absolute values.

Lock it in

Similar question

01

A brass rod has a length of 2.0000 m2.0000\text{ m} at 25.0∘C25.0^\circ\text{C}. Find its change in length ΔL\Delta L and new length when cooled to −15.0∘C-15.0^\circ\text{C}. (Take α=1.90×10−5 ∘C−1\alpha = 1.90 \times 10^{-5}\text{ }^\circ\text{C}^{-1}.)

Answer

ΔT=−15.0∘C−25.0∘C=−40.0∘C\Delta T = -15.0^\circ\text{C} - 25.0^\circ\text{C} = -40.0^\circ\text{C}. Then ΔL=L0αΔT=(2.0000 m)(1.90×10−5 ∘C−1)(−40.0∘C)=−1.52×10−3 m=−1.52 mm\Delta L = L_0 \alpha \Delta T = (2.0000\text{ m})(1.90 \times 10^{-5}\text{ }^\circ\text{C}^{-1})(-40.0^\circ\text{C}) = -1.52 \times 10^{-3}\text{ m} = -1.52\text{ mm}. The new length is L=2.0000 m−0.00152 m=1.9985 mL = 2.0000\text{ m} - 0.00152\text{ m} = 1.9985\text{ m}.

02

A steel measuring tape calibrated at 20.0∘C20.0^\circ\text{C} has α=1.20×10−5 ∘C−1\alpha = 1.20 \times 10^{-5}\text{ }^\circ\text{C}^{-1}. It is used at −10.0∘C-10.0^\circ\text{C} to lay out a rectangular foundation line until the tape reads exactly 30.000 m30.000\text{ m}. What is the true physical distance laid out?

Answer

ΔT=−10.0∘C−20.0∘C=−30.0∘C\Delta T = -10.0^\circ\text{C} - 20.0^\circ\text{C} = -30.0^\circ\text{C}. The fractional change is ΔLL0=(1.20×10−5 ∘C−1)(−30.0∘C)=−3.60×10−4\frac{\Delta L}{L_0} = (1.20 \times 10^{-5}\text{ }^\circ\text{C}^{-1})(-30.0^\circ\text{C}) = -3.60 \times 10^{-4}. Contraction ΔL=(30.000 m)(−3.60×10−4)=−0.0108 m\Delta L = (30.000\text{ m})(-3.60 \times 10^{-4}) = -0.0108\text{ m}. The true distance is Ltrue=30.000 m−0.0108 m=29.989 mL_{\text{true}} = 30.000\text{ m} - 0.0108\text{ m} = 29.989\text{ m}.

03

A surveyor measures a fixed boundary between two monuments using an invar tape calibrated at 20.0∘C20.0^\circ\text{C} (alpha=1.20×10−6 ∘C−1\\alpha = 1.20 \times 10^{-6}\text{ }^\circ\text{C}^{-1}). On a hot day at 45.0∘C45.0^\circ\text{C}, the tape reads 100.000 m100.000\text{ m} between the monuments. What is the true distance between the monuments? If the surveyor instead measures an unknown distance and records 100.000 m100.000\text{ m} on the same hot day, does the true distance exceed or fall short of 100.000 m100.000\text{ m}?

Answer

Here ΔT=45.0∘C−20.0∘C=+25.0∘C\Delta T = 45.0^\circ\text{C} - 20.0^\circ\text{C} = +25.0^\circ\text{C}. The 100 m100\text{ m} tape segment has physically expanded by ΔL=(100.000 m)(1.20×10−6 ∘C−1)(+25.0∘C)=+0.0030 m=+3.0 mm\Delta L = (100.000\text{ m})(1.20 \times 10^{-6}\text{ }^\circ\text{C}^{-1})(+25.0^\circ\text{C}) = +0.0030\text{ m} = +3.0\text{ mm}. Because the span between the 00 and 100 m100\text{ m} marks fits between the monuments, the true distance is Ltrue=100.003 mL_{\text{true}} = 100.003\text{ m}. In both scenarios, each tick mark on the expanded tape is farther apart than normal, so any nominal reading of 100.000 m100.000\text{ m} represents a true physical distance exceeding 100.000 m100.000\text{ m}.

Loading workspace…