Resources
A heating circuit couples electrical circuit analysis with thermodynamics. An immersion heater is constructed from two identical resistive heating elements, each having resistance , connected in parallel with each other across an ideal DC power supply. The immersion heater is submerged in an insulated container holding of liquid water at an initial temperature of . Assuming all electrical energy is transferred as heat to the water (with specific heat capacity ) and neglecting heat capacity of the vessel, calculate the time in seconds required to heat the water to its boiling point of .
Answer and steps
Final answer
Steps
Calculate the equivalent resistance and total electrical power
To find the time required to heat the water to its boiling point, we determine the electrical power delivered to the water and equate the total electrical energy supplied to the thermal energy absorbed.
The two heating elements are identical resistors connected in parallel across the voltage source:
- Each resistor has resistance .
- Supply voltage .
For two identical resistors connected in parallel, the equivalent resistance is:
The total electrical power dissipated by the heater is given by:
(Alternative check: each parallel branch experiences the full , dissipating . The total power is .)
Calculate the thermal energy required to reach boiling point
The heat energy needed to raise the temperature of the water from to is given by the calorimetry formula:
Substitute the given values:
- Mass of water:
- Specific heat capacity:
- Temperature change:
Solve for the heating time
Assuming efficiency, the electrical energy delivered equals the thermal energy absorbed:
Solving for time :
Rounding to three significant figures gives:
Typical errors
01 The student treats the two parallel resistors as connected in series, adding their resistances to obtain 32.0 Ω and underestimating the heating power.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
The problem specifies that the two heating elements are connected in parallel. You added their resistances directly using the series combination formula instead of the reciprocal parallel rule.
- Step 2Correct
Your power formula is correct, but substituting the incorrect series resistance of led to an underestimated power.
- Step 3
- Step 4Correct
Your relationship is completely sound, but substituting propagated the earlier equivalent resistance error into the final time.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the heat energy needed to bring the water to boiling using .
You correctly related electrical energy and thermal energy using .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou used the simple sum formula instead of combining parallel resistors via reciprocals.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated parallel branches as a single series loop, overlooking that connecting identical resistors in parallel provides multiple current paths, which halves the total equivalent resistance rather than doubling it.
REASONING PATH
Your ACEpath teacher’s suggested approach- Parallel Resistor Combination
For two identical resistors in parallel, .
Always verify circuit topology keywords ('in parallel' vs. 'in series') before writing the equivalent resistance formula.
- Parallel Branch Power Check
In parallel, each resistor receives the full supply voltage , so total power is .
Check your equivalent power by calculating the power of one branch first: each resistor dissipates , so two branches must deliver .
CORRECTED PATH
ACEpath Teacher's Demonstration02 The student uses the absolute boiling temperature instead of the temperature change when computing the heat energy, resulting in an overestimated required energy and time.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You used the target final temperature instead of the temperature difference .
- Step 4Correct
Your relationship between energy, power, and time was set up correctly, but the numerical answer inherits the error from using an incorrect value of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the equivalent resistance of two identical resistors in parallel.
You accurately computed the total electrical power using .
You recognized that energy equals power multiplied by time.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the final boiling point instead of the net temperature increase .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConflating absolute temperature with temperature change when applying the heat formula . Specific heat capacity dictates energy required per degree of temperature change, so only the temperature gained from the initial state requires thermal energy.
REASONING PATH
Your ACEpath teacher’s suggested approach- Temperature change in calorimetry
Always identify both the initial temperature and the final temperature , then write explicitly before computing heat energy.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the temperature increase: .
Calculate the thermal energy required: .
Compute the time using power: .
03 The student calculates the power of only one resistor instead of the combination, halving the total power and doubling the required time.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
(or )
You found the power dissipated by one resistor alone. The heater contains two identical elements connected in parallel across , so both elements dissipate power simultaneously.
- Step 2
- Step 3Correct
Your formula and arithmetic are sound, but using the single-resistor power of resulted in an answer that is twice the true heating time.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used the calorimetry relation to find the thermal energy needed to reach boiling.
You correctly connected electrical power, total heat energy, and time through .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou calculated the power of one branch rather than accounting for both parallel heating elements.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking the circuit topology when finding total power: in a multi-element circuit, total power is the sum of the power dissipated by each branch (or ).
REASONING PATH
Your ACEpath teacher’s suggested approach- Parallel Resistor Power
For identical resistors in parallel across voltage , total power is .
Always count the number of active heating elements and sum their dissipated powers or find first.
CORRECTED PATH
ACEpath Teacher's DemonstrationFind the total power delivered by the two parallel branches: .
Divide the required heat energy by the total power: .
Lock it in
How do you calculate the equivalent resistance of two identical resistors connected in parallel?
. Parallel branches divide the resistance because current has multiple independent paths.
Similar question
A kettle contains two identical heating coils connected in parallel to a supply. What is the total electrical power delivered to heat the water?
Answer
. For two identical resistors in parallel, . Power is .
An immersion heater with three identical resistors in parallel is used to heat of water () by . If the heater is powered by a source, how long does this take?
Answer
. Total equivalent resistance is . Total power is . Required heat is . Heating time is .
A dual-element water heater has two heating elements, and . Compare the heating times to deliver of energy at when connected in series versus when connected in parallel.
Answer
Series: ; Parallel: . In series, , , . In parallel, , , .