In an optical calibration bench, an alignment laser is aimed at a plane mirror mounted on a micro-goniometer. The incident beam deviates from the mirror's normal by an angle of 2.40 mrad2.40\text{ mrad}. After traveling a round-trip optical path length of d=3.50 md = 3.50\text{ m} from the mirror to a position-sensitive detector (PSD) oriented perpendicular to the reflected ray, determine the transverse linear displacement yy of the reflected spot on the detector relative to the surface normal axis in millimeters (mm\text{mm}).

Answer and steps

Final answer

y=8.40 mmy = 8.40\text{ mm}

Steps

01

Apply the Law of Reflection

According to the law of reflection, the angle of reflection θr\theta_r equals the angle of incidence θi\theta_i, with both angles measured relative to the mirror's surface normal: θr=θi=2.40 mrad\theta_r = \theta_i = 2.40\text{ mrad}

02

Relate Angular Deflection to Transverse Displacement

The reflected ray travels a distance d=3.50 md = 3.50\text{ m} at an angle θr\theta_r to the normal axis. The transverse displacement yy perpendicular to the normal axis is given geometrically by: y=dsin⁡θry = d \sin\theta_r

Because the angle is very small (θr=2.40 mrad=0.00240 rad≪1 rad\theta_r = 2.40\text{ mrad} = 0.00240\text{ rad} \ll 1\text{ rad}), we apply the small-angle approximation sin⁡θr≈θr\sin\theta_r \approx \theta_r: y≈d⋅θry \approx d \cdot \theta_r

03

Compute the Linear Displacement

Substitute the given values into the equation: y=(3.50 m)⋅(2.40×10−3 rad)=8.40×10−3 my = (3.50\text{ m}) \cdot (2.40 \times 10^{-3}\text{ rad}) = 8.40 \times 10^{-3}\text{ m}

Convert the result to millimeters: y=8.40 mmy = 8.40\text{ mm}

Common Pitfall: Do not confuse the displacement relative to the surface normal axis with the displacement relative to the incoming laser's path. While the total deviation between the incident and reflected beams is 2θi2\theta_i, the angle between the reflected ray and the normal axis is strictly θr=θi\theta_r = \theta_i.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student confuses the single angle of reflection with the total angular deviation of the beam (2θ = 4.80 mrad), doubling the transverse displacement.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Total angular deflection=2θ=2×2.40 mrad=4.80 mrad  ⟹  θdef=4.80×10−3 rad\text{Total angular deflection} = 2\theta = 2 \times 2.40\text{ mrad} = 4.80\text{ mrad} \implies \theta_{\text{def}} = 4.80 \times 10^{-3}\text{ rad}

    Correct

    θr=θi=2.40 mrad=2.40×10−3 rad\theta_r = \theta_i = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}

    The problem asks for the transverse displacement relative to the surface normal axis. By the law of reflection, the angle between the reflected ray and the normal axis is simply θr=θi=2.40 mrad\theta_r = \theta_i = 2.40\text{ mrad}, not the total beam deviation 2θ2\theta.

  2. Step 2

    y=d×θdef  ⟹  y=3.50 m×4.80×10−3 rady = d \times \theta_{\text{def}} \implies y = 3.50\text{ m} \times 4.80 \times 10^{-3}\text{ rad}

    Correct

    y=d⋅θr=(3.50 m)⋅(2.40×10−3 rad)y = d \cdot \theta_r = (3.50\text{ m}) \cdot (2.40 \times 10^{-3}\text{ rad})

    You applied the small-angle approximation formula correctly, but this step inherits the doubled angle from Step 1.

  3. Step 3

    y=1.68×10−2 m=16.8 mmy = 1.68 \times 10^{-2}\text{ m} = 16.8\text{ mm}

    Correct

    y=8.40×10−3 m=8.40 mmy = 8.40 \times 10^{-3}\text{ m} = 8.40\text{ mm}

    Your arithmetic and unit conversion from meters to millimeters are correct, but the final value is doubled due to the error in Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied the small-angle relation y≈d⋅θy \approx d \cdot \theta.

You carried out the arithmetic and unit conversion to millimeters accurately.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reference Axis Confusion

You used the total deflection between the incident and reflected beams (2θ=4.80 mrad2\theta = 4.80\text{ mrad}) rather than the angle between the reflected ray and the surface normal axis (θ=2.40 mrad\theta = 2.40\text{ mrad}).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the angular deviation of the reflected beam relative to the incident direction (2θi2\theta_i) with its angular position measured relative to the mirror's normal axis (θr=θi\theta_r = \theta_i).

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify the Reference Axis
  • The law of reflection states θr=θi\theta_r = \theta_i, where both angles are measured from the surface normal.

  • Always draw the normal line perpendicular to the mirror surface and label the angle of the reflected ray relative to that specific axis.

Total Beam Deviation vs. Normal Angle
  • The angle between the incident ray and the reflected ray is 2θi2\theta_i, whereas the angle between the reflected ray and the normal axis is θi\theta_i.

  • Read the prompt carefully to see whether the detector displacement is measured from the surface normal axis or from the incident beam's path.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the angle between the reflected ray and the normal axis: θr=θi=2.40 mrad=2.40×10−3 rad\theta_r = \theta_i = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}.

  2. Apply the small-angle approximation for transverse displacement: y=dsin⁡θr≈d⋅θry = d \sin\theta_r \approx d \cdot \theta_r.

  3. Substitute the optical path length and angle: y=(3.50 m)⋅(2.40×10−3 rad)=8.40×10−3 my = (3.50\text{ m}) \cdot (2.40 \times 10^{-3}\text{ rad}) = 8.40 \times 10^{-3}\text{ m}.

  4. Convert to millimeters: y=8.40 mmy = 8.40\text{ mm}.

Final answer

y=8.40 mmy = 8.40\text{ mm}

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch the optical ray diagram with the surface normal clearly marked whenever reflection is involved.

  • Check whether target displacements are referenced to the surface normal or to the incoming laser direction.

OverviewACEpath Teacher's Diagnosis

02 The student misinterprets milliradians as degrees and incorrectly converts to radians by multiplying by π/180, leading to a much smaller displacement.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    θ=2.40∘=2.40×π180 rad≈0.04189 rad\theta = 2.40^\circ = 2.40 \times \frac{\pi}{180}\text{ rad} \approx 0.04189\text{ rad}

    Correct

    θ=2.40 mrad=2.40×10−3 rad\theta = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}

    The problem specifies an angle of 2.40 mrad2.40\text{ mrad} (milliradians), not 2.40∘2.40^\circ (degrees). The SI prefix "m" stands for milli (10−310^{-3}), so no degree-to-radian conversion factor π180\frac{\pi}{180} should be applied.

  2. Step 2

    y=d×θ  ⟹  y=3.50 m×0.04189 rad  ⟹  y=0.1466 m=146.6 mmy = d \times \theta \implies y = 3.50\text{ m} \times 0.04189\text{ rad} \implies y = 0.1466\text{ m} = 146.6\text{ mm}

    Correct

    y=d⋅θ=(3.50 m)(2.40×10−3 rad)=8.40×10−3 m=8.40 mmy = d \cdot \theta = (3.50\text{ m})(2.40 \times 10^{-3}\text{ rad}) = 8.40 \times 10^{-3}\text{ m} = 8.40\text{ mm}

    Your small-angle relation y=dθy = d\theta and arithmetic were executed properly, but the value was skewed by the angle conversion error in Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recognized that the small-angle approximation relates transverse displacement to distance by y=dθy = d\theta.

You carried out the subsequent linear calculation and unit conversion to millimeters with accurate arithmetic.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Misinterpretation

You read "mrad\text{mrad}" as degrees and applied an unnecessary π180\frac{\pi}{180} factor instead of converting the metric prefix milli-.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the SI metric prefix "m" (milli-, meaning 10−310^{-3}) on radians with degree measurement.

REASONING PATH
Your ACEpath teacher’s suggested approach
Metric Prefix vs. Angular Unit
  • The abbreviation mrad\text{mrad} stands for milliradian (1 mrad=10−3 rad1\text{ mrad} = 10^{-3}\text{ rad}), which is already in radians.

  • Whenever you see mrad\text{mrad} or μrad\mu\text{rad}, replace the metric prefix directly with powers of ten (10−310^{-3} or 10−610^{-6}) rather than using π180\frac{\pi}{180}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the given angle in radians using the SI prefix: θ=2.40 mrad=2.40×10−3 rad\theta = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}.

  2. Apply the small-angle linear deflection formula: y=dθ=(3.50 m)(2.40×10−3 rad)=8.40×10−3 my = d \theta = (3.50\text{ m})(2.40 \times 10^{-3}\text{ rad}) = 8.40 \times 10^{-3}\text{ m}.

  3. Convert the result to millimeters: y=8.40 mmy = 8.40\text{ mm}.

Final answer

y=8.40 mmy = 8.40\text{ mm}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review SI prefixes commonly attached to angular units, such as mrad\text{mrad} and μrad\mu\text{rad}.

  • Double-check angle units in problem statements before applying degree-to-radian conversions.

OverviewACEpath Teacher's Diagnosis

03 The student misapplies the metric prefix milli- as 10⁻⁶ instead of 10⁻³, underestimating the displacement by three orders of magnitude.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    θ=2.40 mrad=2.40×10−6 rad\theta = 2.40\text{ mrad} = 2.40 \times 10^{-6}\text{ rad}

    Correct

    θ=2.40 mrad=2.40×10−3 rad\theta = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}

    You substituted the prefix milli- (m-\text{m-}) as 10−610^{-6} (which is micro-, μ-\mu\text{-}) instead of 10−310^{-3}.

  2. Step 2

    y=d×θ  ⟹  y=3.50 m×2.40×10−6 rad=8.40×10−6 my = d \times \theta \implies y = 3.50\text{ m} \times 2.40 \times 10^{-6}\text{ rad} = 8.40 \times 10^{-6}\text{ m}

    Correct

    y=dθ=3.50 m×2.40×10−3 rad=8.40×10−3 my = d \theta = 3.50\text{ m} \times 2.40 \times 10^{-3}\text{ rad} = 8.40 \times 10^{-3}\text{ m}

    You correctly applied the small-angle displacement formula and multiplied accurately, but this step inherited the erroneous value of θ\theta from step 1.

  3. Step 3

    y=8.40×10−3 mmy = 8.40 \times 10^{-3}\text{ mm}

    Correct

    y=8.40 mmy = 8.40\text{ mm}

    You correctly converted meters to millimeters by multiplying by 103 mm/m10^3\text{ mm/m}, but the inherited factor of 10−310^{-3} makes the final answer 8.40×10−3 mm8.40 \times 10^{-3}\text{ mm} rather than 8.40 mm8.40\text{ mm}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the law of reflection and the small-angle approximation y=dθy = d \theta.

You correctly multiplied your values and converted from meters to millimeters in the final step.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
SI prefix confusion (milli vs. micro)

You wrote 1 mrad=10−6 rad1\text{ mrad} = 10^{-6}\text{ rad}, confusing the metric prefix milli- (10−310^{-3}) with micro- (10−610^{-6}).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the metric prefix 'milli-' (symbol m\text{m}, value 10−310^{-3}) with 'micro-' (symbol μ\mu, value 10−610^{-6}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Metric Prefixes: Milli vs. Micro
  • The prefix milli- (m\text{m}) represents 10−310^{-3}, whereas micro- (μ\mu) represents 10−610^{-6}.

  • Whenever you see a lowercase 'm' preceding a unit (such as mrad\text{mrad}, mm\text{mm}, or ms\text{ms}), replace it with ×10−3\times 10^{-3} before computing.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. θ=2.40 mrad=2.40×10−3 rad\theta = 2.40\text{ mrad} = 2.40 \times 10^{-3}\text{ rad}

  2. y=dθ=3.50 m×(2.40×10−3 rad)=8.40×10−3 my = d \theta = 3.50\text{ m} \times (2.40 \times 10^{-3}\text{ rad}) = 8.40 \times 10^{-3}\text{ m}

  3. y=(8.40×10−3 m)×(103 mmm)=8.40 mmy = (8.40 \times 10^{-3}\text{ m}) \times \left(10^3\,\frac{\text{mm}}{\text{m}}\right) = 8.40\text{ mm}

Final answer

y=8.40 mmy = 8.40\text{ mm}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review standard SI metric prefixes, focusing on the distinction between milli-=10−3\text{milli-} = 10^{-3} and μicro-=10−6\mu\text{icro-} = 10^{-6}.

  • Practice direct unit cancellations in small-angle beam deflection problems.

Lock it in

Similar question

01

A collimated beam hits a flat mirror at an incidence angle of 1.50 mrad1.50\text{ mrad} relative to the surface normal. A screen is placed parallel to the mirror surface at a distance of 4.00 m4.00\text{ m}. Determine the transverse distance between the point where the normal axis intersects the screen and the reflected laser spot.

Answer

y=6.00 mmy = 6.00\text{ mm}. Using the law of reflection, θr=1.50 mrad\theta_r = 1.50\text{ mrad}. By small-angle approximation, y≈d⋅θr=4.00 m×1.50×10−3 rad=6.00×10−3 m=6.00 mmy \approx d \cdot \theta_r = 4.00\text{ m} \times 1.50 \times 10^{-3}\text{ rad} = 6.00 \times 10^{-3}\text{ m} = 6.00\text{ mm}.

02

An optical lever uses a mirror that tilts by an angle α=1.20 mrad\alpha = 1.20\text{ mrad}. A fixed laser beam originally incident along the surface normal is reflected onto a sensor located 2.50 m2.50\text{ m} away. Calculate: (a) the angle between the reflected ray and the new surface normal, and (b) the linear displacement of the spot on the sensor relative to the original incident beam path.

Answer

(a) θr=1.20 mrad\theta_r = 1.20\text{ mrad}; (b) Δy=6.00 mm\Delta y = 6.00\text{ mm}. Tilting the mirror by α\alpha makes the angle of incidence θi=α=1.20 mrad\theta_i = \alpha = 1.20\text{ mrad}, so relative to the new normal, θr=1.20 mrad\theta_r = 1.20\text{ mrad}. Relative to the fixed incident path, the beam deflects by 2α=2.40 mrad2\alpha = 2.40\text{ mrad}, yielding Δy=d(2α)=2.50 m×2.40×10−3 rad=6.00 mm\Delta y = d(2\alpha) = 2.50\text{ m} \times 2.40 \times 10^{-3}\text{ rad} = 6.00\text{ mm}.

03

In an optical setup, an incident ray deviates from the mirror normal by θi=3.20 mrad\theta_i = 3.20\text{ mrad}. The reflected beam travels d=5.00 md = 5.00\text{ m} to a detector screen oriented perpendicular to the normal axis. Compare the displacement of the reflected spot from the normal axis (ynormy_{\text{norm}}) to the separation distance between the forward extension of the incident ray and the reflected spot at the detector plane (ydevy_{\text{dev}}).

Answer

ynorm=16.0 mmy_{\text{norm}} = 16.0\text{ mm} and ydev=32.0 mmy_{\text{dev}} = 32.0\text{ mm}. Relative to the normal axis, the angle is θr=3.20 mrad\theta_r = 3.20\text{ mrad}, giving ynorm≈d⋅θr=5.00 m×3.20 mrad=16.0 mmy_{\text{norm}} \approx d \cdot \theta_r = 5.00\text{ m} \times 3.20\text{ mrad} = 16.0\text{ mm}. The total angular spread between the symmetric forward-projected incident path and the reflected path is 2θ=6.40 mrad2\theta = 6.40\text{ mrad}, giving ydev≈d⋅(2θ)=32.0 mmy_{\text{dev}} \approx d \cdot (2\theta) = 32.0\text{ mm}.