Resources
A particle beam accelerator fires a relativistic packet of ions with a proper length of . In the laboratory frame, the packet passes a detector with a lab-frame duration of , where its contracted length is measured to be . Convert all quantities to consistent SI units and determine: (a) the Lorentz factor , and (b) the proper transit time (in nanoseconds) corresponding to the laboratory transit interval .
Answer and steps
Final answer
(a) ; (b)
Steps
Part (a): Determine the Lorentz Factor
-
Convert given lengths to SI units:
- Proper length of the ion packet:
- Contracted length observed in the lab frame:
- Apply the length contraction formula: Length contraction states that the length of an object moving relative to an observer is contracted along the direction of motion relative to its rest (proper) length :
- Solve for the Lorentz factor :
Part (b): Determine the Proper Transit Time
-
Identify the relationship between dilated time and proper time:
- The laboratory interval represents the dilated time interval.
- According to the time dilation relation: where is the proper time interval.
- Calculate the proper transit time :
Common Pitfall: Be careful with where the Lorentz factor appears. Because , moving objects are always measured to be shorter than their proper length (), while time intervals measured by non-co-moving clocks are always longer (dilated) compared to the proper time ().
Typical errors
01 The student inverts the length contraction formula as L = γ L_0, leading to a Lorentz factor less than 1.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Length contraction causes moving objects to appear shorter than their proper length, meaning with . Setting inverted the ratio and produced , which is physically impossible because the Lorentz factor must satisfy .
- Step 3Correct
You correctly set up the relation from time dilation, but substituting your earlier value of instead of led to an incorrect numerical result.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted both lengths from centimeters to SI units of meters.
You correctly identified the algebraic relationship connecting proper time to dilated laboratory time.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou placed the Lorentz factor in the numerator as rather than the denominator as .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the dilation of time intervals with the contraction of spatial lengths. While moving clocks tick slower (time interval dilates: ), moving objects contract along their line of motion (). Since , the measured length must be smaller than the proper length .
REASONING PATH
Your ACEpath teacher’s suggested approach- Physical Reality of the Lorentz Factor
For any speed , the Lorentz factor satisfies .
Always verify that your calculated is greater than or equal to ; any value less than signals an inverted ratio.
- Length Contraction vs. Time Dilation
Moving lengths are contracted (), while moving intervals of time are dilated ().
Check whether the quantity should shrink or grow: divide by to make a length shorter, and multiply by to make a time interval longer.
CORRECTED PATH
ACEpath Teacher's DemonstrationState the length contraction equation: .
Solve for the Lorentz factor: .
Substitute into the proper time formula: .
(a) ; (b)
02 The student confuses time dilation with length contraction and multiplies the laboratory time by γ instead of dividing by γ.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
The proper time interval is the shortest time interval measured between two events occurring at the same position in a rest frame. The moving frame's interval is dilated according to , so you need to divide by .
- Step 3Correct
Because the inverted formula was used in the previous step, your substitution yielded instead of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted both given lengths into meters.
You applied the length contraction formula accurately to solve for the Lorentz factor .
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou reversed the relationship between proper time and dilated time. Remember that because , moving clocks run slow: the dilated interval measured by stationary lab clocks is always larger than the proper time interval measured in the co-moving frame ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Proper Time is the Minimum Time
with
Always verify that your calculated proper time is strictly less than or equal to the dilated observer time .
CORRECTED PATH
ACEpath Teacher's DemonstrationWrite the standard time dilation relation: .
Rearrange for the proper transit time: .
Substitute the known values: .
(a) ; (b)
Lock it in
What is the physical range of values for the Lorentz factor for any physical object moving at speed ?
. Since , the denominator , meaning can never be less than .
Similar question
A relativistic spacecraft has a proper length of . As it travels past an orbital station, observers on the station measure its length to be . Calculate the Lorentz factor for the spacecraft relative to the station.
Answer
(or ). Key step: Use length contraction .
A beam of unstable particles has a mean lifetime at rest of . In an accelerator laboratory, their lifetime is measured to be . (a) Find the Lorentz factor . (b) If a bunch of these particles has a rest length of , what is the bunch's length measured in the lab?
Answer
(a) ; (b) . Key steps: Time dilation gives . Length contraction gives .
A relativistic train passes through a tunnel that is long in the ground frame. Detectors indicate that the train takes to completely clear a single stationary sensor on the ground, and observers find its contracted length is while its proper length is . Determine: (a) the Lorentz factor , (b) the proper transit duration recorded by a clock aboard the train, and (c) the speed of the train as a fraction of .
Answer
(a) (or ); (b) ; (c) . Key steps: (a) . (b) . (c) From , solve .