Resources
In a university electrical engineering laboratory, a student performs a four-terminal sensing (Kelvin bridge) characterization of a precision alloy resistor to eliminate lead-wire contact resistance. A regulated current source injects a precisely calibrated current of through the current leads of the device under test. A digital multimeter configured as a high-impedance voltmeter measures a potential drop of across the dedicated inner voltage sensing leads. (a) Calculate the precise resistance of the test specimen in milliohms (). (b) If each outer current lead possesses a parasitic contact resistance of , calculate the total voltage drop output by the current source. (c) Explain why connecting the voltmeter across the inner potential terminals measures only the specimen's resistance, clearly contrasting the current circulating through the loop with the voltage measured across the specific branch.
Answer and steps
Final answer
(a) ; (b) ; (c) The inner voltmeter has an extremely high input impedance (), drawing virtually zero current through the sensing leads (), which ensures zero voltage drop across the voltage lead wires; thus, the voltmeter isolates and measures solely the electrostatic potential difference across the sample itself, while the full current continues to flow through the separate power loop containing the lead resistance.
Steps
Part (a): Determining the Resistance of the Specimen
By Ohm's law, the resistance of a component is defined by the ratio of the potential difference across its terminals to the electric current passing through it:
Given:
- Measured voltage drop:
- Regulated current:
Substitute these values into Ohm's law:
Part (b): Calculating the Total Source Voltage
The current source must drive the full current through the entire closed current loop. This loop consists of:
- The lead resistance of the outgoing wire,
- The specimen resistance,
- The lead resistance of the return wire,
Because these three resistive elements are in series, the total equivalent resistance of the loop is:
Substitute the known values:
The total voltage delivered by the constant current source is:
(or to four significant figures).
Part (c): Why Four-Terminal Sensing Eliminates Lead Resistance
To understand how four-terminal (Kelvin) sensing avoids error, compare the two separate circuits:
- Current Path (Excitation Loop): The power source forces the calibrated current through the outer wires. Because these wires carry substantial current, a noticeable voltage drop occurs across each lead (). In a standard two-wire measurement, these voltage drops would add directly to the measured signal, leading to an enormous measurement error.
- Voltage Sensing Path (Measurement Branch): The voltmeter connects directly across the sample via its own dedicated inner leads. A modern digital voltmeter possesses an extremely high input impedance (typically ). As a result, the current diverted into the voltage-sensing leads is practically zero ().
Because , the voltage drop across the parasitic resistance of the sensing leads is negligible:
Consequently, the voltmeter measures the electrostatic potential difference across the sample alone, completely bypassing the voltage drops across the outer current-carrying leads.
Typical errors
01 The student forgets that a closed circuit loop has two outer current leads and includes only a single lead resistance in the total source voltage calculation.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
A complete circuit loop requires two outer leads (the outgoing feed wire and the return wire). Both leads carry the excitation current, so you must add to the specimen resistance.
- Step 3Correct
Your calculation correctly multiplied your total resistance by the current, but the numerical answer was affected by omitting the second lead resistance in the previous step.
- Step 4
The voltmeter has extremely high internal resistance, so negligible current flows through the inner potential leads. With zero current in the sensing branch, there is no IR drop across the sense leads, measuring only the potential difference across the specimen while current circulates through the outer loop.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used Ohm's law to calculate the specimen resistance in part (a).
You clearly explained how high voltmeter impedance prevents current flow and eliminate lead-resistance voltage drops in part (c).
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou forgot that a physical current loop requires both a supply wire and a return wire, including only one lead resistance instead of two.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking that current excitation leads in a four-wire measurement form a closed circuit requiring two separate conductor paths (each having its own contact and lead resistance) connected to the specimen.
REASONING PATH
Your ACEpath teacher’s suggested approach- Account for Both Current Path Conductors
Every closed current loop has a forward path and a return path; the total outer wire resistance is .
Always trace the full closed path from the source terminal out to the load and back to the source terminal.
CORRECTED PATH
ACEpath Teacher's DemonstrationInclude both the outgoing and return current leads: .
Recalculate the source voltage: .
(or )
02 The student misinterprets the prefix milli- as 10⁻⁶ instead of 10⁻³, leading to an incorrect resistance calculation by three orders of magnitude.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You confused the metric prefix milli- () with micro- (). As a result, your voltage conversion was too small by a factor of , giving instead of .
- Step 2Correct
Your series resistance formula and application of Ohm's law were completely correct, but the numerical result was affected by substituting the incorrect resistance value from part (a).
- Step 3
The voltmeter draws near-zero current because of its high input impedance, preventing any voltage drop across the inner contacts. Thus, reflects only the potential across the specimen, even though the full flows through the outer loop.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recalled and set up Ohm's law ().
You correctly modeled the total circuit resistance by including both outer lead resistances in series with the specimen.
You accurately explained the physical reason why four-terminal sensing eliminates lead-wire contact resistance.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted for the prefix milli- () instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou conflated the metric prefix milli- () with micro- () during unit conversion.
REASONING PATH
Your ACEpath teacher’s suggested approach- Metric Prefixes for Small Quantities
milli- () represents , whereas micro- () represents .
Always double-check the prefix letter before converting: lowercase is milli- (), while Greek is micro- ().
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert the measured voltage using milli- (): .
Recalculate specimen resistance: .
Recompute total loop resistance: .
Calculate source voltage: .
(a) ; (b) ; (c) Valid conceptual explanation as written.
03 The student believes that current divides equally between the voltmeter branch and the specimen rather than recognizing that the high-impedance voltmeter draws virtually zero current.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
The current divides equally between the specimen and the voltmeter branch, so each receives half the current. Since the current splits, the voltmeter measures only the specimen because the outer lead voltage drops are bypassed by the split current.
CorrectA digital voltmeter has an extremely high internal resistance (), so it draws virtually zero current (). Therefore, almost the entire current flows through the specimen, producing negligible drop along the inner sensing leads and isolating the true potential difference across the specimen.
Current does not divide equally. Parallel current division depends inversely on branch resistances (). Because a voltmeter has an enormous input impedance (typically ) compared to the milliohm specimen, virtually all continues through the specimen, leaving .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used Ohm's law to determine the specimen resistance in part (a).
You correctly accounted for both outer lead contact resistances in the series current loop in part (b).
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakenone
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the parallel junction as splitting current equally between the voltmeter and the specimen, overlooking that current divides inversely proportional to branch resistance and that an ideal or high-impedance voltmeter has near-infinite resistance, drawing almost zero current.
REASONING PATH
Your ACEpath teacher’s suggested approach- Voltmeter Input Impedance
A voltmeter is designed with extremely high internal resistance () so that connecting it in parallel does not disturb the circuit.
Assume the sensing branch draws , meaning the main current loop remains unaltered.
- Parallel Current Division
For two parallel branches, current divides inversely with resistance: .
Check the branch resistances before assuming how current splits; equal split only occurs when branch resistances are identical.
CORRECTED PATH
ACEpath Teacher's DemonstrationIdentify the input impedance of the measurement instrument: a digital voltmeter has , whereas the specimen has .
Apply current division: because , the current entering the voltmeter sensing leads is .
Evaluate lead drops: the parasitic resistance of the inner voltage leads causes zero voltage drop ().
Conclude: the voltmeter senses solely the electrostatic potential drop across the specimen without including the drops of the outer excitation wires.
The voltmeter possesses an extremely high input impedance, drawing virtually zero current (). Consequently, all flows through the specimen, no voltage drop occurs across the potential sensing leads, and the meter measures only the true potential difference across the specimen.
Lock it in
In a closed DC loop with two connecting wires of lead resistance each, what is the total lead resistance in series with the load?
A complete loop requires both an outgoing supply conductor and an incoming return conductor.
Similar question
A current source delivers through two leads (each having a resistance of ) to a low-resistance shunt resistor of . Calculate the total voltage output by the current source.
Answer
. Total resistance is . Therefore, .
In a 4-point probe sheet resistance test, a current of is passed between two outer probes. The contact resistance at each outer probe is , and the sample's bulk resistance between the probes is . What total potential difference must the current source supply across its output terminals?
Answer
. The loop includes two outer contact resistances and the sample: . Thus, .
A precision power supply maintains a constant current through a sensor of resistance . If the supply output voltage is measured to be , determine the resistance of each individual outer lead wire assuming identical identical supply and return leads.
Answer
. The total loop resistance is . Since , we have , so per wire.