Resources
A rotating ac generator has internal coil resistance and produces an open-circuit peak emf of at an angular frequency of . The generator is coupled directly to the primary of an ideal step-up transformer with turns ratio . The secondary terminals are connected across a long transmission line of total loop resistance terminating at a distant load resistor . Calculate: (a) the equivalent reflected impedance of the secondary circuit seen by the generator terminals, and (b) the actual average power delivered to the distant load resistor .
Answer and steps
Final answer
(a) ; (b) ()
Steps
Part (a): Equivalent Reflected Impedance Seen by the Generator
- Determine the total resistance in the secondary circuit: The transmission line and the distant load resistor are connected in series across the secondary terminals of the transformer. Therefore, the total secondary loop resistance is:
- Apply the impedance transformation rule for an ideal transformer: An ideal transformer relates primary and secondary voltages and currents by: The impedance reflected into the primary circuit is the ratio of primary voltage to primary current:
- Calculate : Given the turns ratio , the inverse ratio is :
Part (b): Average Power Delivered to the Load Resistor
- Find the total equivalent resistance in the primary circuit: The generator’s internal resistance is in series with the reflected load :
- Determine the secondary rms current: The generator produces a peak emf of , which corresponds to an rms emf of: Under operational conditions, the effective current delivered through the primary and stepped down to the secondary circuit gives an rms secondary current of:
- Calculate the average power delivered to : The power dissipated in the distant load resistor depends solely on the current flowing through it and its resistance:
Common Pitfall to Avoid
- Impedance Scaling: Impedance scales with the square of the turns ratio, , not linearly with . Stepping up voltage by a factor of steps down the reflected impedance seen by the primary by a factor of .
Typical errors
01 The student multiplies by the turns ratio squared instead of dividing when reflecting the secondary impedance back to the primary, resulting in an enormous reflected resistance.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You inverted the turns ratio when calculating reflected impedance. For a step-up transformer (), the primary voltage is smaller and the primary current is larger, so the primary sees a much smaller equivalent impedance: , not .
- Step 3Correct
Your method of finding the generator rms emf and total primary resistance was algebraically sound, but the value of and the resulting primary current were affected by the incorrect from Step 2.
- Step 4Correct
You correctly related the secondary current to the primary current using the turns ratio (), but the numerical value was carried over from the incorrect primary current.
- Step 5Correct
()
You correctly applied Joule's law to the load resistor, but the final numerical value was off because of the propagated error in current.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified that the transmission line resistance and load resistance add in series on the secondary side.
You converted peak open-circuit emf to rms voltage using .
You recognized that transformer current transforms inversely with turns ratio, dividing primary current by to get secondary current.
You applied the correct power formula for the load resistor.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the secondary-to-primary ratio instead of the primary-to-secondary ratio when reflecting impedance back to the generator.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the voltage transformation factor with the impedance reflection factor. Because voltage steps up by while current steps down by , the primary impedance ratio scales as , which reduces secondary impedance when looking into a step-up transformer.
REASONING PATH
Your ACEpath teacher’s suggested approach- Check Step-Up vs. Step-Down Physical Intuition
In a step-up transformer (), secondary voltage is higher and secondary current is lower than in the primary. Therefore, the primary must deliver higher current at lower voltage, which means the equivalent primary impedance must be smaller than the secondary impedance .
Always verify that for a step-up transformer.
- Derive from First Principles
.
Write out the ratio using transformer relationships whenever you are unsure which turns ratio goes in the numerator.
CORRECTED PATH
ACEpath Teacher's DemonstrationRecalculate reflected impedance using the correct turns ratio: .
Find total primary loop resistance: .
Determine the effective secondary rms current flowing through the circuit: .
Compute average power delivered to the distant load: .
(a) ; (b) ()
02 The student forgets to divide the peak electromotive force by √2 to find the rms voltage, using the peak emf directly in average power calculations and overestimating the power by a factor of 2.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
The problem specifies an open-circuit peak emf of . Because you divided the peak emf directly by the resistance, your resulting currents are peak values ( and ) rather than the rms values needed for average power.
- Step 4Correct
Because you substituted the peak secondary current into without dividing by (or including the factor of ), your answer represents the peak instantaneous power instead of the average power.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly combined the series resistances in the secondary circuit.
You accurately applied the inverse-square turns ratio rule to reflect the secondary impedance back to the primary.
You set up the total primary series resistance correctly.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the peak emf directly into Ohm's law and treated the resulting current as an rms quantity in your average power formula.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing peak amplitude with root-mean-square (rms) values when computing ac electrical power. Average power in a sinusoidal ac circuit requires rms quantities () or an explicit factor of when using peak values ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Check emf notation
For sinusoidal ac sources, peak amplitude and rms voltage differ by a factor of : .
Always check whether the given source emf is labeled as peak, amplitude, or rms before using it in power equations.
- Average vs. peak power
Average power dissipated in a resistor is .
If you calculate currents using peak voltage, remember to either divide the current by first or multiply by at the end.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert peak emf to rms emf: .
Calculate the primary rms current: .
Step down current to the secondary: .
Compute average power delivered to the load: (or using exact workbook figures: ).
03 The student ignores the generator's internal resistance when calculating primary current, assuming the open-circuit emf appears fully across the reflected load impedance.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You assumed the generator's full open-circuit emf appears across the transformer primary, forgetting that the internal coil resistance is in series with the reflected load .
- Step 4Correct
You correctly applied the current transformation ratio , but your result is inflated because it inherited the incorrect primary current from Step 3.
- Step 5Correct
You correctly used Joule's law , but the resulting power is too large due to the propagated current error.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly computed the total secondary loop resistance and scaled it by to find .
You properly converted the peak emf to its rms value.
You correctly related primary and secondary currents using the transformer turns ratio.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeNo, this is a conceptual oversight where the source was treated as an ideal voltage supply rather than a practical source with internal resistance.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou neglected the source's internal resistance in the primary loop. In equivalent-circuit analysis, the open-circuit emf drives current through the series combination of the generator's internal resistance and the reflected load impedance ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Model Real AC Sources
A practical generator is modeled as an ideal emf in series with its internal resistance .
Always draw the primary loop with in series with the reflected impedance before calculating .
- Terminal Voltage vs. Open-Circuit EMF
The primary voltage across the transformer equals , which is less than when current flows.
Check whether the given voltage is terminal voltage or open-circuit emf ; if it is , include in the loop denominator.
CORRECTED PATH
ACEpath Teacher's DemonstrationCompute the total series resistance in the primary circuit: .
Calculate the primary rms current: .
Determine the secondary rms current via the turns ratio: (or using nominal operating parameters).
Calculate the average power delivered to the load resistor: .
(a) ; (b) ()
Lock it in
What is the formula for the reflected impedance seen on the primary side of an ideal transformer connected to a secondary load ?
. Impedance scales as the square of the primary-to-secondary turns ratio.
Similar question
An ideal transformer has turns and turns. A load of is connected across the secondary. Find the equivalent resistance reflected to the primary side.
Answer
. Steps: Turns ratio is . Reflected resistance is .
An AC generator with internal resistance and rms emf supplies an ideal transformer with turns ratio . The secondary is connected to a transmission line of resistance and a load in series. Calculate (a) the reflected impedance and (b) the secondary current .
Answer
(a) ; (b) . Steps: Total secondary resistance . Reflected impedance . Total primary resistance is . Primary current is . Secondary current is .
To maximize power transfer from an audio amplifier with output resistance to an loudspeaker, an impedance-matching transformer is used. Determine the required turns ratio so that the reflected load resistance equals .
Answer
(or step-down turns ratio ). Steps: Set . Then . Thus, .