A municipal solid-waste gasification microgrid utilizes synthesis gas (syngas) to operate a combined heat and power (CHP) microturbine. The fuel gas has a lower heating value recorded in industrial units of Hu=14.5 MJ/Nm3H_u = 14.5\text{ MJ/Nm}^3 (megajoules per normal cubic meter at 0∘C0^\circ\text{C} and 101.325 kPa101.325\text{ kPa}). The microturbine consumes fuel gas at a volumetric rate of V′=120 Nm3/hV' = 120\text{ Nm}^3/\text{h}. The gas is combusted (thermal release), expanded through a microturbine shaft (rotational work), and drives an alternator. If the mechanical-to-electrical generator efficiency is ηe=31.5%\eta_e = 31.5\% and the exhaust gas waste-heat recovery boiler captures thermal energy with an efficiency of ηth=52.0%\eta_{\text{th}} = 52.0\% to produce domestic hot water, compute both the net electrical power output PelecP_{\text{elec}} in kilowatts (kW\text{kW}) and the useful thermal heat recovery rate Q˙rec\dot{Q}_{\text{rec}} in kilowatts (kW\text{kW}).

Answer and steps

Final answer

Pelec=152 kWP_{\text{elec}} = 152\text{ kW}; useful heat recovery rate Q˙rec=251 kW\dot{Q}_{\text{rec}} = 251\text{ kW}.

Steps

01

Calculate the Total Chemical Input Power (E˙in\dot{E}_{\text{in}})

The total rate of energy entering the system from the combustion of the fuel gas is the product of its volumetric flow rate V˙\dot{V} and its lower heating value HuH_u:

E˙in=V˙⋅Hu\dot{E}_{\text{in}} = \dot{V} \cdot H_u

First, convert the volumetric flow rate into units of Nm3/s\text{Nm}^3/\text{s}:

V˙=120 Nm3/h3600 s/h=130 Nm3/s≈0.03333 Nm3/s\dot{V} = \frac{120\text{ Nm}^3/\text{h}}{3600\text{ s/h}} = \frac{1}{30}\text{ Nm}^3/\text{s} \approx 0.03333\text{ Nm}^3/\text{s}

Now calculate the total thermal input power in kilowatts (kW=kJ/s\text{kW} = \text{kJ/s}), noting that 1 MJ=1000 kJ1\text{ MJ} = 1000\text{ kJ}:

E˙in=(130 Nm3/s)⋅(14.5 MJ/Nm3)=14.530 MJ/s≈0.48333 MW=483.33 kW\dot{E}_{\text{in}} = \left(\frac{1}{30}\text{ Nm}^3/\text{s}\right) \cdot (14.5\text{ MJ/Nm}^3) = \frac{14.5}{30}\text{ MJ/s} \approx 0.48333\text{ MW} = 483.33\text{ kW}


02

Compute the Net Electrical Power Output (PelecP_{\text{elec}})

The electrical power generated is given by multiplying the total input power by the electrical efficiency ηe=31.5%=0.315\eta_e = 31.5\% = 0.315:

Pelec=ηe⋅E˙inP_{\text{elec}} = \eta_e \cdot \dot{E}_{\text{in}}

Pelec=0.315⋅483.33 kW≈152.25 kW≈152 kWP_{\text{elec}} = 0.315 \cdot 483.33\text{ kW} \approx 152.25\text{ kW} \approx 152\text{ kW}


03

Compute the Useful Thermal Heat Recovery Rate (Q˙rec\dot{Q}_{\text{rec}})

The heat recovery boiler captures waste heat at an efficiency of ηth=52.0%=0.520\eta_{\text{th}} = 52.0\% = 0.520 relative to the total fuel energy input:

Q˙rec=ηth⋅E˙in\dot{Q}_{\text{rec}} = \eta_{\text{th}} \cdot \dot{E}_{\text{in}}

Q˙rec=0.520⋅483.33 kW≈251.33 kW≈251 kW\dot{Q}_{\text{rec}} = 0.520 \cdot 483.33\text{ kW} \approx 251.33\text{ kW} \approx 251\text{ kW}

Common Pitfall: Ensure the volumetric flow rate is converted from hours to seconds (h→3600 s\text{h} \to 3600\text{ s}) before multiplying by the heating value so that the resulting power is in kJ/s\text{kJ/s} (kW\text{kW}) rather than kilowatt-hours per hour or megajoules per hour.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert the volumetric flow rate from per hour to per second, resulting in powers that are 3600 times too large.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Pin=120⋅14.5=1740 MJ/s=1740000 kWP_{\text{in}} = 120 \cdot 14.5 = 1740\text{ MJ/s} = 1740000\text{ kW}

    Correct

    E˙in=120 Nm3/h3600 s/h⋅14.5 MJ/Nm3=14.530 MJ/s≈0.4833 MW=483.33 kW\dot{E}_{\text{in}} = \frac{120\text{ Nm}^3/\text{h}}{3600\text{ s/h}} \cdot 14.5\text{ MJ/Nm}^3 = \frac{14.5}{30}\text{ MJ/s} \approx 0.4833\text{ MW} = 483.33\text{ kW}

    The fuel volumetric flow rate is given as 120 Nm3/h120\text{ Nm}^3/\text{h}, not per second. Multiplying by 14.5 MJ/Nm314.5\text{ MJ/Nm}^3 yields 1740 MJ/h1740\text{ MJ/h}. To obtain power in MJ/s\text{MJ/s} (megawatts) or kJ/s\text{kJ/s} (kilowatts), you must divide by 3600 s/h3600\text{ s/h}.

  2. Step 2

    Pelec=0.315⋅1740000 kW=548100 kWP_{\text{elec}} = 0.315 \cdot 1740000\text{ kW} = 548100\text{ kW}

    Correct

    Pelec=0.315⋅483.33 kW≈152 kWP_{\text{elec}} = 0.315 \cdot 483.33\text{ kW} \approx 152\text{ kW}

    You correctly applied the electrical efficiency relation Pelec=ηe⋅PinP_{\text{elec}} = \eta_e \cdot P_{\text{in}}, but the result carries over the unscaled hourly input power from Step 1.

  3. Step 3

    \dot{Q}{rec\text{rec}} = 0.520 ⋅\cdot 1740000 kW\text{ kW} = 904800 kW\text{ kW}

    Correct

    Q˙rec=0.520⋅483.33 kW≈251 kW\dot{Q}_{\text{rec}} = 0.520 \cdot 483.33\text{ kW} \approx 251\text{ kW}

    You correctly multiplied the thermal efficiency by the input power, but the value is 36003600 times too large due to the error in Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recognized that fuel input power equals volumetric flow rate multiplied by lower heating value.

You correctly converted megajoules to kilojoules using a factor of 10001000.

You applied both electrical and thermal efficiency factors accurately to the input power.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Conversion (Hours to Seconds)

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating hourly volumetric flow rate (Nm3/h\text{Nm}^3/\text{h}) with flow rate per second (Nm3/s\text{Nm}^3/\text{s}), leading to an implicit unit of MJ/h\text{MJ/h} being treated directly as MJ/s\text{MJ/s} (MW\text{MW}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Verify Power Time Base
  • 1 W=1 J/s1\text{ W} = 1\text{ J/s} and 1 kW=1 kJ/s1\text{ kW} = 1\text{ kJ/s}. Any quantity measured per hour must be divided by 3600 s3600\text{ s} to yield standard power units.

  • Check input flow rates for time units (s\text{s}, min\text{min}, or h\text{h}) before evaluating energy rates.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert the volumetric flow rate to standard SI time units: V˙=120 Nm3/h3600 s/h=130 Nm3/s≈0.0333 Nm3/s\dot{V} = \frac{120\text{ Nm}^3/\text{h}}{3600\text{ s/h}} = \frac{1}{30}\text{ Nm}^3/\text{s} \approx 0.0333\text{ Nm}^3/\text{s}.

  2. Calculate the input power: E˙in=(130 Nm3/s)⋅(14.5 MJ/Nm3)≈0.4833 MW=483.33 kW\dot{E}_{\text{in}} = \left(\frac{1}{30}\text{ Nm}^3/\text{s}\right) \cdot (14.5\text{ MJ/Nm}^3) \approx 0.4833\text{ MW} = 483.33\text{ kW}.

  3. Calculate the net electrical power: Pelec=0.315⋅483.33 kW≈152.25 kW≈152 kWP_{\text{elec}} = 0.315 \cdot 483.33\text{ kW} \approx 152.25\text{ kW} \approx 152\text{ kW}.

  4. Calculate the useful heat recovery rate: Q˙rec=0.520⋅483.33 kW≈251.33 kW≈251 kW\dot{Q}_{\text{rec}} = 0.520 \cdot 483.33\text{ kW} \approx 251.33\text{ kW} \approx 251\text{ kW}.

Final answer

Pelec=152 kWP_{\text{elec}} = 152\text{ kW}; useful heat recovery rate Q˙rec=251 kW\dot{Q}_{\text{rec}} = 251\text{ kW}.

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write out complete physical units during intermediate multiplications to catch dimensional mismatches like MJ/h\text{MJ/h} vs. MJ/s\text{MJ/s}.

  • Perform a quick plausibility check: microturbines typically generate hundreds of kilowatts, not hundreds of megawatts.

OverviewACEpath Teacher's Diagnosis

02 The student assumes the thermal recovery efficiency applies only to the remaining unrecovered energy after electricity generation rather than the total fuel input.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pin=(1203600)∗14.5=0.48333 MJ/s=483.33 kWP_{\text{in}} = \left(\frac{120}{3600}\right) * 14.5 = 0.48333\text{ MJ/s} = 483.33\text{ kW}

  2. Step 2

    Pelec=0.315∗483.33 kW=152.25 kWP_{\text{elec}} = 0.315 * 483.33\text{ kW} = 152.25\text{ kW}

  3. Step 3

    Prem=483.33−152.25=331.08 kW  ⟹  Q˙rec=0.520∗331.08 kW=172.16 kWP_{\text{rem}} = 483.33 - 152.25 = 331.08\text{ kW} \implies \dot{Q}_{\text{rec}} = 0.520 * 331.08\text{ kW} = 172.16\text{ kW}

    Correct

    Q˙rec=ηth⋅E˙in=0.520⋅483.33 kW≈251 kW\dot{Q}_{\text{rec}} = \eta_{\text{th}} \cdot \dot{E}_{\text{in}} = 0.520 \cdot 483.33\text{ kW} \approx 251\text{ kW}

    In combined heat and power (CHP) systems, thermal efficiency ηth\eta_{\text{th}} is conventionally defined relative to the total chemical energy input E˙in\dot{E}_{\text{in}}, not just the unrecovered residual energy.

WHAT YOU DID WELL
Compliments from Your Teacher

You successfully converted the fuel gas volumetric flow rate from hourly to per-second units.

You calculated the total rate of fuel input energy accurately in kilowatts.

You correctly applied the electrical efficiency to find the net electrical output.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Thermal efficiency base misapplication

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the thermal efficiency as a sub-efficiency applied sequentially to remaining losses rather than as the standard first-law thermal efficiency defined over total fuel input power.

REASONING PATH
Your ACEpath teacher’s suggested approach
CHP Thermal Efficiency Definition
  • For a combined heat and power system, both ηe=PelecE˙in\eta_e = \frac{P_{\text{elec}}}{\dot{E}_{\text{in}}} and ηth=Q˙recE˙in\eta_{\text{th}} = \frac{\dot{Q}_{\text{rec}}}{\dot{E}_{\text{in}}} share the total fuel energy input E˙in\dot{E}_{\text{in}} as their common denominator.

  • Always multiply the given thermal efficiency directly by the total fuel input power E˙in\dot{E}_{\text{in}} unless a problem explicitly states the boiler efficiency is based strictly on the exhaust stream enthalpy.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recall that the thermal efficiency ηth=52.0%\eta_{\text{th}} = 52.0\% relates directly to the total input power E˙in=483.33 kW\dot{E}_{\text{in}} = 483.33\text{ kW}.

  2. Calculate the useful thermal recovery rate directly: Q˙rec=0.520×483.33 kW=251.33 kW\dot{Q}_{\text{rec}} = 0.520 \times 483.33\text{ kW} = 251.33\text{ kW}.

Final answer

Pelec≈152 kWP_{\text{elec}} \approx 152\text{ kW}, Q˙rec≈251 kW\dot{Q}_{\text{rec}} \approx 251\text{ kW}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the formal definitions of electrical efficiency, thermal efficiency, and overall cogeneration efficiency in CHP systems.

  • Practice identifying the reference base (total fuel energy input vs. available exhaust stream) from system specifications.

OverviewACEpath Teacher's Diagnosis

03 The student divides the input energy by the efficiencies instead of multiplying by them.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pin=(1203600)∗14.5=483.33 kWP_{\text{in}} = \left(\frac{120}{3600}\right) * 14.5 = 483.33\text{ kW}

  2. Step 2

    Pelec=483.330.315=1534.38 kWP_{\text{elec}} = \frac{483.33}{0.315} = 1534.38\text{ kW}

    Correct

    Pelec=ηe⋅Pin=0.315⋅483.33 kW≈152.25 kWP_{\text{elec}} = \eta_e \cdot P_{\text{in}} = 0.315 \cdot 483.33\text{ kW} \approx 152.25\text{ kW}

    Efficiency is defined as output divided by input (η=Pout/Pin\eta = P_{\text{out}} / P_{\text{in}}). Therefore, the useful electrical power output is Pelec=ηe⋅PinP_{\text{elec}} = \eta_e \cdot P_{\text{in}}, not Pin/ηeP_{\text{in}} / \eta_e. Dividing by a fraction smaller than 11 produces an impossible power output that exceeds the input energy.

  3. Step 3

    Q˙rec=483.330.520=929.48 kW\dot{Q}_{\text{rec}} = \frac{483.33}{0.520} = 929.48\text{ kW}

    Correct

    Q˙rec=ηth⋅Pin=0.520⋅483.33 kW≈251.33 kW\dot{Q}_{\text{rec}} = \eta_{\text{th}} \cdot P_{\text{in}} = 0.520 \cdot 483.33\text{ kW} \approx 251.33\text{ kW}

    Similarly, the thermal recovery rate represents a fraction of the total fuel power input, so it must be calculated as Q˙rec=ηth⋅Pin=0.520⋅483.33 kW≈251.33 kW\dot{Q}_{\text{rec}} = \eta_{\text{th}} \cdot P_{\text{in}} = 0.520 \cdot 483.33\text{ kW} \approx 251.33\text{ kW}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the fuel volumetric flow rate from Nm3/h\text{Nm}^3/\text{h} to Nm3/s\text{Nm}^3/\text{s}.

You accurately multiplied the flow rate by the lower heating value to obtain the total fuel chemical input power in kilowatts.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Efficiency Equation

You divided the input power by the decimal efficiencies instead of multiplying by them.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You reversed the relationship between input power, output power, and efficiency. Useful output power is always a fraction of the total supplied input power for passive or conversion systems (Pout=η⋅Pin≤PinP_{\text{out}} = \eta \cdot P_{\text{in}} \le P_{\text{in}}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Sanity Check with Conservation of Energy
  • For any heat engine or energy converter, the First and Second Laws of Thermodynamics dictate that useful power output cannot exceed total fuel input (Pout≤PinP_{\text{out}} \le P_{\text{in}}).

  • Always verify that your calculated useful output is strictly less than your fuel input power.

Efficiency Rearrangement Rule
  • η=Useful OutputTotal Input  ⟹  Useful Output=η⋅Total Input\eta = \frac{\text{Useful Output}}{\text{Total Input}} \implies \text{Useful Output} = \eta \cdot \text{Total Input} and Total Input=Useful Outputη\text{Total Input} = \frac{\text{Useful Output}}{\eta}.

  • Ask yourself whether you are starting from the total fuel supplied (multiply by η\eta) or from a required target output demand (divide by η\eta).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate electrical power by multiplying the total input power by ηe\eta_e: Pelec=0.315⋅483.33 kW≈152.25 kWP_{\text{elec}} = 0.315 \cdot 483.33\text{ kW} \approx 152.25\text{ kW}.

  2. Calculate useful thermal heat recovery by multiplying total input power by ηth\eta_{\text{th}}: Q˙rec=0.520⋅483.33 kW≈251.33 kW\dot{Q}_{\text{rec}} = 0.520 \cdot 483.33\text{ kW} \approx 251.33\text{ kW}.

Final answer

Pelec≈152 kWP_{\text{elec}} \approx 152\text{ kW} and Q˙rec≈251 kW\dot{Q}_{\text{rec}} \approx 251\text{ kW}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the base definition of thermal/generator efficiency: η=Pout/Pin\eta = P_{\text{out}} / P_{\text{in}}.

  • Perform a physical reality check on outputs: output power must be less than 100%100\% of the fuel input rate.

  • Practice problems that switch between finding required input fuel versus actual available output power.

Lock it in

Similar question

01

A biogas boiler consumes methane with a lower heating value of Hu=36 MJ/m3H_u = 36\text{ MJ/m}^3 at a flow rate of 180 m3/h180\text{ m}^3/\text{h}. If the thermal efficiency of the boiler is η=85%\eta = 85\%, calculate the useful heat output rate in kilowatts (kW\text{kW}).

Answer

Q˙out=1530 kW\dot{Q}_{\text{out}} = 1530\text{ kW}. Key steps: E˙in=180 m3/h3600 s/h⋅36 MJ/m3=1.8 MW=1800 kW\dot{E}_{\text{in}} = \frac{180\text{ m}^3/\text{h}}{3600\text{ s/h}} \cdot 36\text{ MJ/m}^3 = 1.8\text{ MW} = 1800\text{ kW}. Useful heat output Q˙out=0.85⋅1800 kW=1530 kW\dot{Q}_{\text{out}} = 0.85 \cdot 1800\text{ kW} = 1530\text{ kW}.

02

A diesel generator consumes fuel with an energy density of 42.0 MJ/kg42.0\text{ MJ/kg} at a rate of 24.0 kg/h24.0\text{ kg/h}. It delivers 91.0 kW91.0\text{ kW} of electrical power. Determine the electrical efficiency ηe\eta_e of the generator.

Answer

ηe=32.5%\eta_e = 32.5\%. Key steps: E˙in=24.0 kg/h3600 s/h⋅42.0 MJ/kg=0.280 MW=280 kW\dot{E}_{\text{in}} = \frac{24.0\text{ kg/h}}{3600\text{ s/h}} \cdot 42.0\text{ MJ/kg} = 0.280\text{ MW} = 280\text{ kW}. Efficiency ηe=91.0 kW280 kW=0.325=32.5%\eta_e = \frac{91.0\text{ kW}}{280\text{ kW}} = 0.325 = 32.5\%.

03

A combined heat and power (CHP) plant has an electrical efficiency of ηe=35%\eta_e = 35\% and an overall cogeneration efficiency of ηtotal=82%\eta_{\text{total}} = 82\%. If it produces 700 kW700\text{ kW} of net electrical power, find the fuel energy consumption rate in GJ/h\text{GJ/h} and the recovered thermal heat rate in kW\text{kW}.

Answer

Fuel consumption rate =7.2 GJ/h= 7.2\text{ GJ/h}; thermal recovery rate Q˙rec=940 kW\dot{Q}_{\text{rec}} = 940\text{ kW}. Key steps: Input power E˙in=700 kW0.35=2000 kW=2.0 MJ/s\dot{E}_{\text{in}} = \frac{700\text{ kW}}{0.35} = 2000\text{ kW} = 2.0\text{ MJ/s}. In hourly units: 2.0 MJ/s⋅3600 s/h=7200 MJ/h=7.2 GJ/h2.0\text{ MJ/s} \cdot 3600\text{ s/h} = 7200\text{ MJ/h} = 7.2\text{ GJ/h}. Thermal efficiency ηth=82%−35%=47%\eta_{\text{th}} = 82\% - 35\% = 47\%. Thermal recovery rate Q˙rec=0.47⋅2000 kW=940 kW\dot{Q}_{\text{rec}} = 0.47 \cdot 2000\text{ kW} = 940\text{ kW}.