Resources
A cryogenic laboratory specimen requires cooling by condensing vaporized nitrogen gas. A stream of gaseous nitrogen at its normal boiling point of is condensed to liquid nitrogen at a rate of . Given that the latent heat of vaporization of nitrogen is , calculate the rate of heat removal (in watts, ) required to maintain this continuous condensation rate.
Answer and steps
Final answer
Steps
Identify the Physical Process
When a substance undergoes a phase change at its boiling point without any change in temperature, the amount of thermal energy transferred is governed by the latent heat of vaporization:
For a continuous, steady-flow process, the rate of heat removal (thermal power, ) is directly proportional to the mass condensation rate ():
Convert Given Values to Standard SI Units
To calculate the rate of heat removal in watts (), convert all quantities into standard SI units ( and ):
- Mass condensation rate ():
- Latent heat of vaporization ():
Calculate the Rate of Heat Removal
Substitute the converted values into the power equation:
Rounding to three significant figures gives:
Common Pitfalls to Avoid
- Unit Mismatches: Ensure the mass rate is converted from milligrams () to kilograms () and latent heat from kilojoules () to joules () so that the resulting unit evaluates properly to .
- Temperature Change: Because the phase change occurs at a constant temperature of , specific heat capacity () and temperature changes () are not involved in this calculation.
Typical errors
01 The student confuses milligrams with grams by using 10^-3 instead of 10^-6 to convert milligrams to kilograms, resulting in an answer that is three orders of magnitude too large.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You converted milligrams to kilograms as if . Since and , , so equals .
- Step 3
- Step 4Correct
Your arithmetic followed directly from your previous values, but using the incorrect mass condensation rate caused the final power to be off by a factor of .
WHAT YOU DID WELL
Compliments from Your TeacherYou selected the correct physical relation for a steady-state phase change.
You correctly converted the latent heat into standard SI units of .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou divided by instead of when converting milligrams to kilograms, confusing milligrams with grams.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisSkipping the intermediate base unit (grams) during metric prefix conversion often leads to conflating milli- () with the conversion between grams and kilograms (), omitting the cumulative factor of .
REASONING PATH
Your ACEpath teacher’s suggested approach- Chain-link conversion through base units
and .
Always convert from a prefixed unit to the SI base unit (or through grams first) before substituting into thermal power formulas.
CORRECTED PATH
ACEpath Teacher's DemonstrationRounding to three significant figures gives .
02 The student forgets to convert the latent heat from kilojoules per kilogram to joules per kilogram, resulting in a calculated power that is a factor of 1000 too small.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You kept as instead of converting it to the base SI unit . Because , multiplying by yields power in kilowatts (), not watts ().
- Step 3Correct
Due to the missing factor of from the latent heat unit conversion, your numerical result is times smaller than the true value.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the mass flow rate from milligrams per second into standard kilograms per second.
You selected the correct physical relationship between thermal power and latent heat of vaporization ().
You carried out the arithmetic multiplication accurately.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted directly into the power equation without converting kilojoules to joules.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou overlooked prefix consistency across combined SI units; when an output requires watts (), all energy inputs must be expressed in joules () rather than kilojoules ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Base SI Unit Requirement for Watts
. A watt requires joules in the numerator, not kilojoules.
Always convert to by multiplying by before evaluating power in watts.
- Dimensional Unit Verification
.
Check your intermediate units; if your calculation yields , multiply by to report the answer in .
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert the latent heat of vaporization to standard SI units: .
Substitute the converted rate and latent heat into the power equation: .
Evaluate the product: .
03 The student misinterprets the temperature of 77.36 K as needing to be multiplied into the heat transfer equation alongside the latent heat, confusing latent phase change with temperature-dependent heat capacity.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Phase changes occur at a constant temperature where heat transfer is given by , or . Multiplying by temperature is physically incorrect and violates dimensional consistency (yielding instead of ).
- Step 3Correct
Your arithmetic matches your written formula, but the result is incorrect because temperature was included in the calculation.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the mass flow rate from to .
You correctly converted the latent heat of vaporization from to .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou brought the constant boiling temperature of into the heat transfer product.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused isothermal latent heat transfer () with temperature-dependent sensible heat transfer (), not realizing that phase changes take place at constant temperature without temperature in the heat formula.
REASONING PATH
Your ACEpath teacher’s suggested approach- Isothermal Phase Change
During a phase change at a boiling or freezing point, temperature remains constant and thermal energy depends only on mass and latent heat: .
Check whether a substance is changing phase or changing temperature. If it is only changing phase, leave temperature out of the energy formula.
- Dimensional Consistency Check
The unit of latent heat is . Multiplying by mass rate () directly yields power in .
Always verify units: . Multiplying by kelvins () would incorrectly give .
CORRECTED PATH
ACEpath Teacher's DemonstrationState the steady-state thermal power formula for phase change:
Substitute the standard SI values:
Evaluate the product:
Lock it in
How many kilograms are in ?
. Remember: and , so you multiply the factors to get .
Similar question
A cryocooler condenses vaporized helium at its boiling point at a continuous rate of . If the latent heat of vaporization of helium is , calculate the required cooling power in milliwatts ().
Answer
(or ). Key steps: ; ; .
An oxygen liquefaction chamber condenses oxygen gas at (). If the refrigeration unit removes heat at a constant rate of , determine the mass of oxygen condensed each minute in grams.
Answer
. Key steps: . Over one minute (), .
A cold finger condenser receives saturated nitrogen vapor () at and sub-cools the resulting liquid to . The specific heat capacity of liquid nitrogen is . If the nitrogen flow rate is , calculate the total heat removal rate in watts.
Answer
. Key steps: . Latent power . Sensible cooling power . Total power .