Resources

In a physics laboratory calorimetry experiment to calibrate a continuous-flow electrical calorimeter, water flows through an insulated tube at a constant mass flow rate of dmdt=0.0350 kg/s\frac{dm}{dt} = 0.0350\text{ kg}/\text{s}. A heating coil immersed in the stream is connected across an adjustable DC power supply delivering a potential difference of V=120.0 VV = 120.0\text{ V} and drawing a steady current of I=4.50 AI = 4.50\text{ A}. Calibrated platinum resistance thermometers measure steady-state inlet and outlet temperatures of Tin=18.20∘CT_{\text{in}} = 18.20^\circ\text{C} and Tout=21.65∘CT_{\text{out}} = 21.65^\circ\text{C}, respectively. Assume steady-state flow where the rate of change of internal energy of the fluid element passing through is driven entirely by electrical heating and small heat loss to the ambient surroundings: (a) calculate the electrical power supplied PinP_{\text{in}}, (b) calculate the rate at which internal energy is gained by the flowing water stream dUwdt=(dmdt)cw(Tout−Tin)\frac{dU_w}{dt} = \left(\frac{dm}{dt}\right) c_w (T_{\text{out}} - T_{\text{in}}) taking cw=4.184×103 J/(kg⋅∘C)c_w = 4.184 \times 10^3\text{ J}/(\text{kg}\cdot^\circ\text{C}), and (c) calculate the rate of parasitic heat loss dQlossdt\frac{dQ_{\text{loss}}}{dt} to the surroundings.

Answer and steps

Final answer

(a) Pin=5.40×102 WP_{\text{in}} = 5.40 \times 10^2\text{ W}; (b) dUwdt=5.05×102 W\frac{dU_w}{dt} = 5.05 \times 10^2\text{ W}; (c) dQlossdt=35 W\frac{dQ_{\text{loss}}}{dt} = 35\text{ W}.

Steps

Part (a): Calculate the electrical power supplied

The electrical power input PinP_{\text{in}} delivered to the heating coil by the DC power source depends directly on the potential difference VV and the steady electric current II:

Pin=V⋅IP_{\text{in}} = V \cdot I

Substitute the given values:

Pin=(120.0 V)⋅(4.50 A)=540 W=5.40×102 WP_{\text{in}} = (120.0\text{ V}) \cdot (4.50\text{ A}) = 540\text{ W} = 5.40 \times 10^2\text{ W}


Part (b): Calculate the rate of internal energy gain by the water stream

For an incompressible liquid flowing continuously under steady-state conditions, the rate at which thermal internal energy is absorbed by the fluid stream is related to the mass flow rate dmdt\frac{dm}{dt}, the specific heat capacity cwc_w, and the temperature rise ΔT=Tout−Tin\Delta T = T_{\text{out}} - T_{\text{in}}:

ΔT=21.65∘C−18.20∘C=3.45∘C\Delta T = 21.65^\circ\text{C} - 18.20^\circ\text{C} = 3.45^\circ\text{C}

Now, compute the rate of increase of internal energy dUwdt\frac{dU_w}{dt}:

dUwdt=(dmdt)cw(Tout−Tin)\frac{dU_w}{dt} = \left(\frac{dm}{dt}\right) c_w (T_{\text{out}} - T_{\text{in}})

Substitute the numerical values:

dUwdt=(0.0350 kg/s)⋅(4.184×103 J/(kg⋅∘C))⋅(3.45∘C)\frac{dU_w}{dt} = (0.0350\text{ kg/s}) \cdot (4.184 \times 10^3\text{ J}/(\text{kg}\cdot^\circ\text{C})) \cdot (3.45^\circ\text{C})

dUwdt≈505.22 W≈5.05×102 W\frac{dU_w}{dt} \approx 505.22\text{ W} \approx 5.05 \times 10^2\text{ W}


Part (c): Determine the rate of heat loss to the surroundings

Applying the principle of conservation of energy to the calorimeter control volume at steady state:

Rate of energy input=Rate of internal energy increase+Rate of energy lost\text{Rate of energy input} = \text{Rate of internal energy increase} + \text{Rate of energy lost}

Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt}

Rearranging gives the rate of parasitic heat loss dQlossdt\frac{dQ_{\text{loss}}}{dt}:

dQlossdt=Pin−dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt}

dQlossdt=540 W−505.22 W=34.78 W≈35 W\frac{dQ_{\text{loss}}}{dt} = 540\text{ W} - 505.22\text{ W} = 34.78\text{ W} \approx 35\text{ W}

Pitfall Note: Temperature represents the average kinetic energy per particle at a given point, while internal energy accounts for the total thermal energy carried by the bulk fluid, and heat represents the energy transferred across boundaries due to a temperature gradient. Confusing heat flow with internal energy change leads to misidentifying which terms enter the steady-flow energy balance.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 A student reverses the terms in the conservation of energy equation, mistakenly adding the heat gain of water to the electrical power input to find the heat loss.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pin=V⋅I=120.0⋅4.50=540 WP_{\text{in}} = V \cdot I = 120.0 \cdot 4.50 = 540\text{ W}

  2. Step 2

    ΔT=21.65−18.20=3.45∘C  ⟹  dUwdt=dmdt⋅cw⋅ΔT=0.0350⋅4184⋅3.45=505.2 W\Delta T = 21.65 - 18.20 = 3.45^\circ\text{C} \implies \frac{dU_w}{dt} = \frac{dm}{dt} \cdot c_w \cdot \Delta T = 0.0350 \cdot 4184 \cdot 3.45 = 505.2\text{ W}

  3. Step 3

    dQlossdt=Pin+dUwdt=540+505.2=1045.2 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} + \frac{dU_w}{dt} = 540 + 505.2 = 1045.2\text{ W}

    Correct

    dQlossdt=Pin−dUwdt=540 W−505.22 W≈35 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} = 540\text{ W} - 505.22\text{ W} \approx 35\text{ W}

    By conservation of energy at steady state, the supplied electrical power is partitioned into warming the water and heat lost to the surroundings: Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt}. Adding the two terms implies that more energy leaves the system as heat than was supplied in total.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the electrical power delivered by the DC supply using P=VIP = VI.

You accurately computed the temperature rise and the rate of internal energy gain of the flowing water.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign Error in Steady-Flow Energy Balance

You wrote dQlossdt=Pin+dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} + \frac{dU_w}{dt} instead of dQlossdt=Pin−dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused total energy input with an output term when setting up the energy conservation balance, mistakenly treating the internal energy gain of the water as an energy source alongside the electrical power rather than an energy sink.

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify Inputs and Outputs
  • At steady state, ∑Power In=∑Power Out\sum \text{Power In} = \sum \text{Power Out}.

  • Label electrical heating as an input (PinP_{\text{in}}) and both fluid internal energy rise (dUwdt\frac{dU_w}{dt}) and parasitic losses (dQlossdt\frac{dQ_{\text{loss}}}{dt}) as energy destinations.

Physical Plausibility Check
  • Parasitic heat loss cannot exceed the total power supplied to an otherwise passive heater.

  • Notice that 1045.2 W>540 W1045.2\text{ W} > 540\text{ W}, which signals that energy is being created rather than conserved.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. State the steady-state conservation of energy equation: Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt}.

  2. Isolate the rate of heat loss: dQlossdt=Pin−dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt}.

  3. Substitute the values from parts (a) and (b): dQlossdt=540 W−505.22 W=34.78 W\frac{dQ_{\text{loss}}}{dt} = 540\text{ W} - 505.22\text{ W} = 34.78\text{ W}.

Final answer

(a) Pin=5.40×102 WP_{\text{in}} = 5.40 \times 10^2\text{ W}; (b) dUwdt=5.05×102 W\frac{dU_w}{dt} = 5.05 \times 10^2\text{ W}; (c) dQlossdt=35 W\frac{dQ_{\text{loss}}}{dt} = 35\text{ W}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the generic balance equation Rate of Energy In=Rate of Energy Out\text{Rate of Energy In} = \text{Rate of Energy Out} before rearranging terms.

  • Check that any calculated parasitic loss is strictly less than the total input power.

OverviewACEpath Teacher's Diagnosis

02 A student subtracts the temperatures in reverse order when computing ΔT, leading to a negative energy gain and an erroneous heat loss calculation.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Pin=V⋅I  ⟹  Pin=120.0⋅4.50=540 WP_{\text{in}} = V \cdot I \implies P_{\text{in}} = 120.0 \cdot 4.50 = 540\text{ W}

  2. Step 2

    ΔT=Tin−Tout=18.20−21.65=−3.45∘C  ⟹  dUwdt=0.0350⋅4184⋅(−3.45)=−505.2 W\Delta T = T_{\text{in}} - T_{\text{out}} = 18.20 - 21.65 = -3.45^\circ\text{C} \implies \frac{dU_w}{dt} = 0.0350 \cdot 4184 \cdot (-3.45) = -505.2\text{ W}

    Correct

    ΔT=Tout−Tin=21.65∘C−18.20∘C=3.45∘C  ⟹  dUwdt=(0.0350 kg/s)(4.184×103 J/(kg⋅∘C))(3.45∘C)≈505.2 W\Delta T = T_{\text{out}} - T_{\text{in}} = 21.65^\circ\text{C} - 18.20^\circ\text{C} = 3.45^\circ\text{C} \implies \frac{dU_w}{dt} = (0.0350\text{ kg/s})(4.184 \times 10^3\text{ J}/(\text{kg}\cdot^\circ\text{C}))(3.45^\circ\text{C}) \approx 505.2\text{ W}

    You subtracted the temperatures in reverse order as Tin−ToutT_{\text{in}} - T_{\text{out}} rather than the final outlet temperature minus the initial inlet temperature, Tout−TinT_{\text{out}} - T_{\text{in}}. Because the flowing water is heated as it passes through the calorimeter, its temperature and internal energy must increase.

  3. Step 3

    dQlossdt=Pin−dUwdt  ⟹  dQlossdt=540−(−505.2)=1045.2 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} \implies \frac{dQ_{\text{loss}}}{dt} = 540 - (-505.2) = 1045.2\text{ W}

    Correct

    dQlossdt=Pin−dUwdt=540 W−505.2 W≈35 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} = 540\text{ W} - 505.2\text{ W} \approx 35\text{ W}

    Your steady-flow energy conservation setup was mathematically sound, but substituting the negative internal energy rate from step 2 caused the heat loss to be greatly overstated.

WHAT YOU DID WELL
Compliments from Your Teacher

You used the correct relationship between voltage, current, and electrical power in part (a).

You correctly identified the steady-state control volume energy balance equation relating power input, internal energy gain, and heat loss rate.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reversed Temperature Difference (Sign Error)

You set ΔT=Tin−Tout\Delta T = T_{\text{in}} - T_{\text{out}} instead of ΔT=Tfinal−Tinitial=Tout−Tin\Delta T = T_{\text{final}} - T_{\text{initial}} = T_{\text{out}} - T_{\text{in}}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing initial and final states for a continuous flow system caused you to calculate a negative temperature change for a stream that was clearly absorbing heat and warming up.

REASONING PATH
Your ACEpath teacher’s suggested approach
Define change as final minus initial
  • For any thermodynamic process or flow stream, ΔT=Tfinal−Tinitial=Tout−Tin\Delta T = T_{\text{final}} - T_{\text{initial}} = T_{\text{out}} - T_{\text{in}}.

  • Check the physical direction of flow: the outlet stream represents the final state, so evaluate Tout−TinT_{\text{out}} - T_{\text{in}}.

Verify physical plausibility
  • When energy is added to a single-phase fluid without phase change, internal energy must increase ( dUdt>0\,\frac{dU}{dt} > 0).

  • If a heating element delivers power to a fluid stream, confirm that both ΔT\Delta T and dUdt\frac{dU}{dt} are positive before continuing.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the positive temperature increase of the water: ΔT=Tout−Tin=21.65∘C−18.20∘C=3.45∘C\Delta T = T_{\text{out}} - T_{\text{in}} = 21.65^\circ\text{C} - 18.20^\circ\text{C} = 3.45^\circ\text{C}.

  2. Evaluate the rate of internal energy gain: dUwdt=(dmdt)cwΔT=(0.0350 kg/s)(4184 J/(kg⋅∘C))(3.45∘C)≈505.22 W=5.05×102 W\frac{dU_w}{dt} = \left(\frac{dm}{dt}\right) c_w \Delta T = (0.0350\text{ kg/s})(4184\text{ J}/(\text{kg}\cdot^\circ\text{C}))(3.45^\circ\text{C}) \approx 505.22\text{ W} = 5.05 \times 10^2\text{ W}.

  3. Substitute into the steady-state energy balance: dQlossdt=Pin−dUwdt=540 W−505.22 W≈35 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} = 540\text{ W} - 505.22\text{ W} \approx 35\text{ W}.

Final answer

(a) Pin=5.40×102 WP_{\text{in}} = 5.40 \times 10^2\text{ W}; (b) dUwdt=5.05×102 W\frac{dU_w}{dt} = 5.05 \times 10^2\text{ W}; (c) dQlossdt=35 W\frac{dQ_{\text{loss}}}{dt} = 35\text{ W}.

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write ΔT\Delta T explicitly as Tfinal−TinitialT_{\text{final}} - T_{\text{initial}} (or Tout−TinT_{\text{out}} - T_{\text{in}}) before plugging in numbers.

  • Perform a sanity check on energy conservation: heat loss to cooler surroundings must be less than the total power input.

OverviewACEpath Teacher's Diagnosis

03 A student confuses the direction of the energy balance and calculates heat loss as the energy gained by water minus the electrical power supplied, yielding a negative rate.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pin=120.0∗4.50=540 WP_{\text{in}} = 120.0 * 4.50 = 540\text{ W}

  2. Step 2

    ΔT=21.65−18.20=3.45 ∘C  ⟹  dUwdt=0.0350∗4184∗3.45=505.2 W\Delta T = 21.65 - 18.20 = 3.45\text{ }^\circ\text{C} \implies \frac{dU_w}{dt} = 0.0350 * 4184 * 3.45 = 505.2\text{ W}

  3. Step 3

    dQlossdt=dUwdt−Pin  ⟹  dQlossdt=505.2−540=−34.8 W\frac{dQ_{\text{loss}}}{dt} = \frac{dU_w}{dt} - P_{\text{in}} \implies \frac{dQ_{\text{loss}}}{dt} = 505.2 - 540 = -34.8\text{ W}

    Correct

    dQlossdt=Pin−dUwdt=540 W−505.2 W=34.8 W≈35 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} = 540\text{ W} - 505.2\text{ W} = 34.8\text{ W} \approx 35\text{ W}

    You inverted the steady-state energy conservation relation. Total power supplied equals internal energy rate gained by the water plus heat loss rate to surroundings (Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt}), so dQlossdt=Pin−dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly computed the electrical power entering the system using the product of potential difference and current.

You determined the temperature rise and accurately computed the rate of internal energy absorption of the fluid stream.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign / Direction Inversion in Energy Balance

You subtracted the input power from the internal energy gain instead of subtracting the internal energy gain from the input power.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You set up the steady-state conservation of energy balance in reverse, placing the input energy on the same side as the internal energy gain rather than treating the electrical supply as the sole source that splits into water heating and heat lost to the ambient environment.

REASONING PATH
Your ACEpath teacher’s suggested approach
Steady-State Energy Conservation
  • Energy Inflow Rate=Energy Outflow Rate+Internal Energy Rate Transferred\text{Energy Inflow Rate} = \text{Energy Outflow Rate} + \text{Internal Energy Rate Transferred}

  • Write Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt} before rearranging terms.

Physical Reality Check for Heat Loss
  • A loss rate defined as dQlossdt\frac{dQ_{\text{loss}}}{dt} represents heat leaving the warmer system into cooler surroundings and must be positive.

  • Check that Pin>dUwdtP_{\text{in}} > \frac{dU_w}{dt} when heat escapes; a negative value signals an inverted difference.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply steady-state conservation of energy: Pin=dUwdt+dQlossdtP_{\text{in}} = \frac{dU_w}{dt} + \frac{dQ_{\text{loss}}}{dt}.

  2. Isolate the rate of parasitic heat loss: dQlossdt=Pin−dUwdt\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt}.

  3. Substitute the values found in parts (a) and (b): dQlossdt=540 W−505.2 W=34.8 W\frac{dQ_{\text{loss}}}{dt} = 540\text{ W} - 505.2\text{ W} = 34.8\text{ W}.

Final answer

(a) 5.40×102 W5.40 \times 10^2\text{ W}; (b) 5.05×102 W5.05 \times 10^2\text{ W}; (c) 35 W35\text{ W} (or 34.8 W34.8\text{ W})

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write out the verbal energy balance ('Total power in = Power gained by fluid + Power lost') before rearranging algebraically.

  • Check the physical sign: any quantity explicitly labeled 'loss' should evaluate to a positive magnitude when energy is escaping the system.

Lock it in

Similar question

01

A continuous-flow water heater operates at a steady electrical power input of Pin=1800 WP_{\text{in}} = 1800\text{ W}. Water with specific heat c=4184 J/(kg⋅∘C)c = 4184\text{ J}/(\text{kg}\cdot^\circ\text{C}) passes through at a rate of 0.0120 kg/s0.0120\text{ kg/s} and experiences a temperature rise of 32.0∘C32.0^\circ\text{C}. Calculate the rate of heat loss to the surroundings, dQlossdt\frac{dQ_{\text{loss}}}{dt}.

Answer

dUwdt=(0.0120)(4184)(32.0)≈1606.7 W\frac{dU_w}{dt} = (0.0120)(4184)(32.0) \approx 1606.7\text{ W}. By conservation of energy, dQlossdt=Pin−dUwdt=1800−1606.7≈1.93×102 W\frac{dQ_{\text{loss}}}{dt} = P_{\text{in}} - \frac{dU_w}{dt} = 1800 - 1606.7 \approx 1.93 \times 10^2\text{ W}.

02

In a continuous-flow calorimetry experiment, oil with specific heat capacity c=2.10×103 J/(kg⋅∘C)c = 2.10 \times 10^3\text{ J}/(\text{kg}\cdot^\circ\text{C}) flows at 0.0500 kg/s0.0500\text{ kg/s} through a tube. When an electrical heater supplies 1500 W1500\text{ W}, the temperature of the oil rises by 13.5∘C13.5^\circ\text{C}. Determine the percentage of the supplied electrical power that is lost to the surroundings.

Answer

dUoildt=(0.0500)(2100)(13.5)=1417.5 W\frac{dU_{\text{oil}}}{dt} = (0.0500)(2100)(13.5) = 1417.5\text{ W}. Heat loss rate is dQlossdt=1500−1417.5=82.5 W\frac{dQ_{\text{loss}}}{dt} = 1500 - 1417.5 = 82.5\text{ W}. Percentage lost =82.51500×100%=5.50%= \frac{82.5}{1500} \times 100\% = 5.50\%.

03

Two identical runs of a continuous-flow calorimeter are conducted to eliminate the unknown rate of heat loss dQlossdt\frac{dQ_{\text{loss}}}{dt} (assumed constant since inlet, outlet, and ambient temperatures are held fixed). In Run 1, electrical power P1=300.0 WP_1 = 300.0\text{ W} produces a temperature rise ΔT=4.00∘C\Delta T = 4.00^\circ\text{C} with mass flow rate m˙1=0.0150 kg/s\dot{m}_1 = 0.0150\text{ kg/s}. In Run 2, P2=480.0 WP_2 = 480.0\text{ W} produces the same ΔT=4.00∘C\Delta T = 4.00^\circ\text{C} with m˙2=0.0260 kg/s\dot{m}_2 = 0.0260\text{ kg/s}. Find the specific heat capacity cc of the liquid and the constant rate of heat loss dQlossdt\frac{dQ_{\text{loss}}}{dt}.

Answer

Subtracting the two energy balance equations (P2−P1)=(m˙2−m˙1)cΔT(P_2 - P_1) = (\dot{m}_2 - \dot{m}_1) c \Delta T yields 180.0=(0.0110)(c)(4.00)180.0 = (0.0110)(c)(4.00), so c=180.00.0440≈4091 J/(kg⋅∘C)c = \frac{180.0}{0.0440} \approx 4091\text{ J}/(\text{kg}\cdot^\circ\text{C}). Substituting back into Run 1 gives dQlossdt=P1−m˙1cΔT=300.0−(0.0150)(4090.9)(4.00)=300.0−245.5=54.5 W\frac{dQ_{\text{loss}}}{dt} = P_1 - \dot{m}_1 c \Delta T = 300.0 - (0.0150)(4090.9)(4.00) = 300.0 - 245.5 = 54.5\text{ W}.

Loading workspace…