In a physics laboratory calorimetry experiment to calibrate a continuous-flow electrical calorimeter, water flows through an insulated tube at a constant mass flow rate of . A heating coil immersed in the stream is connected across an adjustable DC power supply delivering a potential difference of and drawing a steady current of . Calibrated platinum resistance thermometers measure steady-state inlet and outlet temperatures of and , respectively. Assume steady-state flow where the rate of change of internal energy of the fluid element passing through is driven entirely by electrical heating and small heat loss to the ambient surroundings: (a) calculate the electrical power supplied , (b) calculate the rate at which internal energy is gained by the flowing water stream taking , and (c) calculate the rate of parasitic heat loss to the surroundings.
Answer and steps
Final answer
(a) ; (b) ; (c) .
Steps
Part (a): Calculate the electrical power supplied
The electrical power input delivered to the heating coil by the DC power source depends directly on the potential difference and the steady electric current :
Substitute the given values:
Part (b): Calculate the rate of internal energy gain by the water stream
For an incompressible liquid flowing continuously under steady-state conditions, the rate at which thermal internal energy is absorbed by the fluid stream is related to the mass flow rate , the specific heat capacity , and the temperature rise :
Now, compute the rate of increase of internal energy :
Substitute the numerical values:
Part (c): Determine the rate of heat loss to the surroundings
Applying the principle of conservation of energy to the calorimeter control volume at steady state:
Rearranging gives the rate of parasitic heat loss :
Pitfall Note: Temperature represents the average kinetic energy per particle at a given point, while internal energy accounts for the total thermal energy carried by the bulk fluid, and heat represents the energy transferred across boundaries due to a temperature gradient. Confusing heat flow with internal energy change leads to misidentifying which terms enter the steady-flow energy balance.
Typical errors
01 A student reverses the terms in the conservation of energy equation, mistakenly adding the heat gain of water to the electrical power input to find the heat loss.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
By conservation of energy at steady state, the supplied electrical power is partitioned into warming the water and heat lost to the surroundings: . Adding the two terms implies that more energy leaves the system as heat than was supplied in total.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the electrical power delivered by the DC supply using .
You accurately computed the temperature rise and the rate of internal energy gain of the flowing water.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused total energy input with an output term when setting up the energy conservation balance, mistakenly treating the internal energy gain of the water as an energy source alongside the electrical power rather than an energy sink.
REASONING PATH
Your ACEpath teacher’s suggested approach- Identify Inputs and Outputs
At steady state, .
Label electrical heating as an input () and both fluid internal energy rise () and parasitic losses () as energy destinations.
- Physical Plausibility Check
Parasitic heat loss cannot exceed the total power supplied to an otherwise passive heater.
Notice that , which signals that energy is being created rather than conserved.
CORRECTED PATH
ACEpath Teacher's DemonstrationState the steady-state conservation of energy equation: .
Isolate the rate of heat loss: .
Substitute the values from parts (a) and (b): .
(a) ; (b) ; (c)
02 A student subtracts the temperatures in reverse order when computing ΔT, leading to a negative energy gain and an erroneous heat loss calculation.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You subtracted the temperatures in reverse order as rather than the final outlet temperature minus the initial inlet temperature, . Because the flowing water is heated as it passes through the calorimeter, its temperature and internal energy must increase.
- Step 3Correct
Your steady-flow energy conservation setup was mathematically sound, but substituting the negative internal energy rate from step 2 caused the heat loss to be greatly overstated.
WHAT YOU DID WELL
Compliments from Your TeacherYou used the correct relationship between voltage, current, and electrical power in part (a).
You correctly identified the steady-state control volume energy balance equation relating power input, internal energy gain, and heat loss rate.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou set instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing initial and final states for a continuous flow system caused you to calculate a negative temperature change for a stream that was clearly absorbing heat and warming up.
REASONING PATH
Your ACEpath teacher’s suggested approach- Define change as final minus initial
For any thermodynamic process or flow stream, .
Check the physical direction of flow: the outlet stream represents the final state, so evaluate .
- Verify physical plausibility
When energy is added to a single-phase fluid without phase change, internal energy must increase ().
If a heating element delivers power to a fluid stream, confirm that both and are positive before continuing.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the positive temperature increase of the water: .
Evaluate the rate of internal energy gain: .
Substitute into the steady-state energy balance: .
(a) ; (b) ; (c) .
03 A student confuses the direction of the energy balance and calculates heat loss as the energy gained by water minus the electrical power supplied, yielding a negative rate.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You inverted the steady-state energy conservation relation. Total power supplied equals internal energy rate gained by the water plus heat loss rate to surroundings (), so .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly computed the electrical power entering the system using the product of potential difference and current.
You determined the temperature rise and accurately computed the rate of internal energy absorption of the fluid stream.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou subtracted the input power from the internal energy gain instead of subtracting the internal energy gain from the input power.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou set up the steady-state conservation of energy balance in reverse, placing the input energy on the same side as the internal energy gain rather than treating the electrical supply as the sole source that splits into water heating and heat lost to the ambient environment.
REASONING PATH
Your ACEpath teacher’s suggested approach- Steady-State Energy Conservation
Write before rearranging terms.
- Physical Reality Check for Heat Loss
A loss rate defined as represents heat leaving the warmer system into cooler surroundings and must be positive.
Check that when heat escapes; a negative value signals an inverted difference.
CORRECTED PATH
ACEpath Teacher's DemonstrationApply steady-state conservation of energy: .
Isolate the rate of parasitic heat loss: .
Substitute the values found in parts (a) and (b): .
(a) ; (b) ; (c) (or )
Lock it in
How is the steady-state energy balance formulated for an electrically heated fluid stream with heat loss?
. The supplied electrical power equals the rate of internal energy gain plus the rate of heat lost to the surroundings.
Similar question
A continuous-flow water heater operates at a steady electrical power input of . Water with specific heat passes through at a rate of and experiences a temperature rise of . Calculate the rate of heat loss to the surroundings, .
Answer
. By conservation of energy, .
In a continuous-flow calorimetry experiment, oil with specific heat capacity flows at through a tube. When an electrical heater supplies , the temperature of the oil rises by . Determine the percentage of the supplied electrical power that is lost to the surroundings.
Answer
. Heat loss rate is . Percentage lost .
Two identical runs of a continuous-flow calorimeter are conducted to eliminate the unknown rate of heat loss (assumed constant since inlet, outlet, and ambient temperatures are held fixed). In Run 1, electrical power produces a temperature rise with mass flow rate . In Run 2, produces the same with . Find the specific heat capacity of the liquid and the constant rate of heat loss .
Answer
Subtracting the two energy balance equations yields , so . Substituting back into Run 1 gives .