Resources

A uniform horizontal beam of length L=3.00 mL = 3.00\text{ m} and mass m=20.0 kgm = 20.0\text{ kg} is hinged to a vertical wall at point OO. The outer end of the beam is supported by a light tie-wire making an angle of θ=30.0∘\theta = 30.0^\circ above the horizontal beam. A concentrated load of mass M=40.0 kgM = 40.0\text{ kg} hangs from the beam at a distance d=2.00 md = 2.00\text{ m} from the hinge. Using g=9.80 m/s2g = 9.80\text{ m/s}^2 and setting the sum of torques about pivot OO to zero, determine the tension TT in the supporting wire.

Answer and steps

Final answer

T=719 NT = 719\text{ N}

Steps

01

Identify the forces and their lever arms

To find the tension TT in the wire, we apply the rotational equilibrium condition about the hinge point OO: ∑τO=0\sum \tau_O = 0 Choosing the hinge OO as the pivot eliminates the unknown reaction forces from the wall, since their line of action passes through OO (lever arm is zero).

  1. Weight of the uniform beam (WbW_b):
    Because the beam is uniform, its weight acts downward at its center of mass, halfway along its length: rb=L2=3.00 m2=1.50 mr_b = \frac{L}{2} = \frac{3.00\text{ m}}{2} = 1.50\text{ m} Wb=mg=20.0 kg⋅9.80 m/s2=196 NW_b = m g = 20.0\text{ kg} \cdot 9.80\text{ m/s}^2 = 196\text{ N} This produces a clockwise torque: τb=−Wb⋅rb=−(196 N)(1.50 m)=−294 N⋅m\tau_b = - W_b \cdot r_b = - (196\text{ N})(1.50\text{ m}) = -294\text{ N}\cdot\text{m}
  2. Weight of the hanging load (WLW_L):
    The load acts downward at a distance d=2.00 md = 2.00\text{ m} from OO: WL=Mg=40.0 kg⋅9.80 m/s2=392 NW_L = M g = 40.0\text{ kg} \cdot 9.80\text{ m/s}^2 = 392\text{ N} This also creates a clockwise torque: τL=−WL⋅d=−(392 N)(2.00 m)=−784 N⋅m\tau_L = - W_L \cdot d = - (392\text{ N})(2.00\text{ m}) = -784\text{ N}\cdot\text{m}
  3. Tension in the wire (TT):
    The wire is attached at the outer end (L=3.00 mL = 3.00\text{ m}) at an angle of θ=30.0∘\theta = 30.0^\circ above the beam. The perpendicular component of the tension is T⊥=Tsin⁡θT_\perp = T \sin\theta, which creates a counterclockwise torque: τT=+Tsin⁡(30.0∘)⋅L=T⋅0.500⋅3.00 m=(1.50 m)T\tau_T = + T \sin(30.0^\circ) \cdot L = T \cdot 0.500 \cdot 3.00\text{ m} = (1.50\text{ m}) T

02

Set the sum of torques to zero

Balancing counterclockwise and clockwise torques:

∑τO=τT+τb+τL=0\sum \tau_O = \tau_T + \tau_b + \tau_L = 0

(1.50 m)T−294 N⋅m−784 N⋅m=0(1.50\text{ m}) T - 294\text{ N}\cdot\text{m} - 784\text{ N}\cdot\text{m} = 0

(1.50 m)T=1078 N⋅m(1.50\text{ m}) T = 1078\text{ N}\cdot\text{m}


03

Solve for TT

T=1078 N⋅m1.50 m≈718.67 NT = \frac{1078\text{ N}\cdot\text{m}}{1.50\text{ m}} \approx 718.67\text{ N}

Rounding to three significant figures gives:

T=719 NT = 719\text{ N}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student misplaces the weight of the uniform beam at its full length L instead of at its center of mass L/2.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ΣτO=T⋅L⋅sin⁡(30.0∘)−m⋅g⋅L−M⋅g⋅d=0  ⟹  T⋅3.00⋅0.50−20.0⋅9.80⋅3.00−40.0⋅9.80⋅2.00=0\Sigma\tau_O = T \cdot L \cdot \sin(30.0^\circ) - m \cdot g \cdot L - M \cdot g \cdot d = 0 \implies T \cdot 3.00 \cdot 0.50 - 20.0 \cdot 9.80 \cdot 3.00 - 40.0 \cdot 9.80 \cdot 2.00 = 0

    Correct

    ∑τO=TLsin⁡(30.0∘)−mg(L2)−Mgd=0  ⟹  T(3.00)(0.500)−(20.0)(9.80)(1.50)−(40.0)(9.80)(2.00)=0\sum \tau_O = T L \sin(30.0^\circ) - m g \left(\frac{L}{2}\right) - M g d = 0 \implies T(3.00)(0.500) - (20.0)(9.80)(1.50) - (40.0)(9.80)(2.00) = 0

    Because the horizontal beam is uniform, its gravitational force acts at its center of mass, located halfway along the beam (r=L2=1.50 mr = \frac{L}{2} = 1.50\text{ m}), not at the outer tip (L=3.00 mL = 3.00\text{ m}).

  2. Step 2

    1.50⋅T−588−784=0  ⟹  1.50⋅T=13721.50 \cdot T - 588 - 784 = 0 \implies 1.50 \cdot T = 1372

    Correct

    1.50T−294−784=0  ⟹  1.50T=10781.50 T - 294 - 784 = 0 \implies 1.50 T = 1078

    You carried out the arithmetic correctly based on your previous torque expression, but this intermediate sum is affected by using 588 N⋅m588\text{ N}\cdot\text{m} instead of 294 N⋅m294\text{ N}\cdot\text{m}.

  3. Step 3

    T=914.67 NT = 914.67\text{ N}

    Correct

    T=719 NT = 719\text{ N}

    Your final calculation reflects the propagated center-of-mass lever arm error. Solving 1.50T=1078 N⋅m1.50 T = 1078\text{ N}\cdot\text{m} yields T≈719 NT \approx 719\text{ N}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the hinge point OO as the optimal pivot to eliminate unknown wall reaction forces.

You correctly resolved the wire tension into its perpendicular component Tsin⁡(30.0∘)T \sin(30.0^\circ) at distance LL.

You correctly computed the torque for the hanging concentrated mass using MgdM g d.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Uniform beam center of mass misplaced

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the uniform beam as if its entire mass were concentrated at the far end LL, overlooking that the weight of an extended uniform object acts through its geometric center of mass at L2\frac{L}{2}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Extended Uniform Body Lever Arm
  • For a uniform rigid body of length LL in a uniform gravitational field, the effective point of action for its total weight is its center of mass at L2\frac{L}{2}.

  • Always mark the center of mass at L2\frac{L}{2} on your free-body diagram before writing the torque equation.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Replace the beam weight lever arm LL with L2=1.50 m\frac{L}{2} = 1.50\text{ m}: τb=−(20.0 kg)(9.80 m/s2)(1.50 m)=−294 N⋅m\tau_b = -(20.0\text{ kg})(9.80\text{ m/s}^2)(1.50\text{ m}) = -294\text{ N}\cdot\text{m}.

  2. Substitute into the balanced torque equation: 1.50T−294−784=01.50 T - 294 - 784 = 0.

  3. Combine clockwise torques: 1.50T=1078 N⋅m1.50 T = 1078\text{ N}\cdot\text{m}.

Final answer

T=719 NT = 719\text{ N}

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch each force vector directly onto the beam before writing formulas to verify each lever arm from pivot OO.

  • Distinguish between point masses attached at specific coordinates and the distributed weight of the beam acting at its midpoint.

OverviewACEpath Teacher's Diagnosis

02 The student omits the perpendicular angle factor sin(θ) for the tension torque, mistakenly using the entire tension force as if it acted perpendicularly.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ∑τO=T⋅L−m⋅g⋅(L2)−M⋅g⋅d=0\sum \tau_O = T \cdot L - m \cdot g \cdot \left(\frac{L}{2}\right) - M \cdot g \cdot d = 0

    Correct

    ∑τO=Tsin⁡θ⋅L−m⋅g⋅(L2)−M⋅g⋅d=0\sum \tau_O = T \sin\theta \cdot L - m \cdot g \cdot \left(\frac{L}{2}\right) - M \cdot g \cdot d = 0

    You treated the full tension TT as being perpendicular to the beam. Because the wire pulls at an angle of θ=30.0∘\theta = 30.0^\circ relative to the horizontal beam, only its perpendicular component T⊥=Tsin⁡θT_\perp = T \sin\theta exerts torque about the pivot OO.

  2. Step 2

    T⋅3.00−20.0⋅9.80⋅1.50−40.0⋅9.80⋅2.00=0⟹3.00⋅T−294−784=0⟹3.00⋅T=1078T \cdot 3.00 - 20.0 \cdot 9.80 \cdot 1.50 - 40.0 \cdot 9.80 \cdot 2.00 = 0 \Longrightarrow 3.00 \cdot T - 294 - 784 = 0 \Longrightarrow 3.00 \cdot T = 1078

    Correct

    Tsin⁡(30.0∘)⋅3.00−20.0⋅9.80⋅1.50−40.0⋅9.80⋅2.00=0⟹1.50⋅T=1078T \sin(30.0^\circ) \cdot 3.00 - 20.0 \cdot 9.80 \cdot 1.50 - 40.0 \cdot 9.80 \cdot 2.00 = 0 \Longrightarrow 1.50 \cdot T = 1078

    Your numerical evaluation of the gravitational torques was entirely correct, but the coefficient of TT carried forward the missing sin⁡(30.0∘)\sin(30.0^\circ) factor.

  3. Step 3

    T=359.33 NT = 359.33\text{ N}

    Correct

    T=10781.50≈719 NT = \frac{1078}{1.50} \approx 719\text{ N}

    Your division 1078/3.001078 / 3.00 is mathematically correct for your equation, but the final answer is affected by the missing trigonometric factor.

WHAT YOU DID WELL
Compliments from Your Teacher

You selected the hinge point OO as the pivot to eliminate unknown reaction forces.

You correctly placed the uniform beam's weight at its center of mass, L/2=1.50 mL/2 = 1.50\text{ m}.

You accurately calculated both downward gravitational torques and applied consistent rotational signs.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of angle factor in torque calculation

You wrote T⋅LT \cdot L instead of Tsin⁡(30.0∘)⋅LT \sin(30.0^\circ) \cdot L, forgetting that the wire pulls at an angle rather than perpendicularly.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing general force magnitude with the perpendicular force component (or perpendicular lever arm) when evaluating τ=rFsin⁡θ\tau = r F \sin\theta.

REASONING PATH
Your ACEpath teacher’s suggested approach
Perpendicular Component of Force
  • Only the component of force perpendicular to the position vector creates torque: τ=rF⊥=rFsin⁡θ\tau = r F_\perp = r F \sin\theta.

  • Always sketch the vector FF and decompose it into parallel and perpendicular components relative to the lever arm before writing the torque equation.

Effective Lever Arm Check
  • Alternatively, find the perpendicular distance from the pivot to the line of action: r⊥=rsin⁡θr_\perp = r \sin\theta.

  • Verify that if θ<90∘\theta < 90^\circ, the effective lever arm must be strictly less than the total physical distance rr.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Include the perpendicular component of the tension: τT=Tsin⁡(30.0∘)⋅L=T(0.500)(3.00 m)=1.50T N⋅m\tau_T = T \sin(30.0^\circ) \cdot L = T (0.500)(3.00\text{ m}) = 1.50 T\text{ N}\cdot\text{m}.

  2. Set the sum of torques to zero: 1.50T−294 N⋅m−784 N⋅m=01.50 T - 294\text{ N}\cdot\text{m} - 784\text{ N}\cdot\text{m} = 0.

  3. Combine the clockwise torques: 1.50T=1078 N⋅m1.50 T = 1078\text{ N}\cdot\text{m}.

  4. Solve for the wire tension: T=10781.50≈718.67 NT = \frac{1078}{1.50} \approx 718.67\text{ N}.

Final answer

T=719 NT = 719\text{ N}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how angled forces produce torque by practicing the two equivalent definitions: τ=r(Fsin⁡θ)\tau = r (F\sin\theta) and τ=(rsin⁡θ)F\tau = (r\sin\theta) F.

  • Whenever a force is not perpendicular to a body, draw a right triangle showing the parallel and perpendicular force components before writing down ∑τ=0\sum \tau = 0.

OverviewACEpath Teacher's Diagnosis

03 The student forgets to account for the gravitational torque due to the beam's own mass.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ∑τO=T⋅L⋅sin⁡(30.0∘)−M⋅g⋅d=0  ⟹  T⋅3.00⋅sin⁡(30.0∘)−40.0⋅9.80⋅2.00=0\sum \tau_O = T \cdot L \cdot \sin(30.0^\circ) - M \cdot g \cdot d = 0 \implies T \cdot 3.00 \cdot \sin(30.0^\circ) - 40.0 \cdot 9.80 \cdot 2.00 = 0

    Correct

    ∑τO=TLsin⁡(30.0∘)−mg(L2)−Mgd=0\sum \tau_O = T L \sin(30.0^\circ) - m g \left(\frac{L}{2}\right) - M g d = 0

    You correctly expressed the counterclockwise torque of the wire and the clockwise torque of the hanging load, but you left out the clockwise torque produced by the beam's own mass (m=20.0 kgm = 20.0\text{ kg}) acting at its center of gravity (r=L/2=1.50 mr = L/2 = 1.50\text{ m}).

  2. Step 2

    1.50⋅T−784=0  ⟹  1.50⋅T=784  ⟹  T=522.67 N1.50 \cdot T - 784 = 0 \implies 1.50 \cdot T = 784 \implies T = 522.67\text{ N}

    Correct

    1.50T−294−784=0  ⟹  1.50T=1078  ⟹  T≈719 N1.50 T - 294 - 784 = 0 \implies 1.50 T = 1078 \implies T \approx 719\text{ N}

    Your algebraic solving steps are carried out correctly, but the resulting tension is smaller than expected because the beam's own weight was missing from the torque sum.

WHAT YOU DID WELL
Compliments from Your Teacher

You chose the hinge point OO as the pivot, correctly eliminating the unknown hinge reaction forces.

You resolved the wire tension into its perpendicular component Tsin⁡(30.0∘)T \sin(30.0^\circ) to find its torque.

You correctly calculated the torque due to the hanging mass as Mgd=784 N⋅mM g d = 784\text{ N}\cdot\text{m}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted beam weight in rotational equilibrium

The beam's mass m=20.0 kgm = 20.0\text{ kg} given in the problem statement was overlooked during the torque summation.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating extended real objects as massless lines when an external load is present, forgetting that any non-massless uniform body experiences an internal gravity force acting at its center of mass.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check for Body Weight
  • If a rigid body has a stated mass m>0m > 0, its weight w=mgw = mg exerts a torque unless its center of mass lies directly on the pivot.

  • Draw a free-body diagram and place a downward vector mgmg at the center of mass (midpoint L/2L/2 for a uniform beam) before writing ∑τ=0\sum \tau = 0.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the beam's weight: Wb=mg=(20.0 kg)(9.80 m/s2)=196 NW_b = m g = (20.0\text{ kg})(9.80\text{ m/s}^2) = 196\text{ N}.

  2. Find the torque of the beam about pivot OO: τb=−Wb(L2)=−(196 N)(1.50 m)=−294 N⋅m\tau_b = -W_b \left(\frac{L}{2}\right) = -(196\text{ N})(1.50\text{ m}) = -294\text{ N}\cdot\text{m}.

  3. Set up the complete torque balance: (Tsin⁡30.0∘)(3.00 m)−294 N⋅m−784 N⋅m=0(T \sin 30.0^\circ)(3.00\text{ m}) - 294\text{ N}\cdot\text{m} - 784\text{ N}\cdot\text{m} = 0.

  4. Solve for tension: 1.50T=1078 N⋅m  ⟹  T=10781.50≈718.67 N1.50 T = 1078\text{ N}\cdot\text{m} \implies T = \frac{1078}{1.50} \approx 718.67\text{ N}.

Final answer

T=719 NT = 719\text{ N}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always highlight the word 'uniform' and any given mass for the beam to remind yourself to draw its center-of-gravity force vector.

  • Count the forces on your free-body diagram and ensure every force not passing through the pivot has a corresponding term in ∑τ=0\sum \tau = 0.

Lock it in

Similar question

01

A uniform horizontal bar of length L=2.00 mL = 2.00\text{ m} and mass m=12.0 kgm = 12.0\text{ kg} is hinged to a wall at one end. A support cable is attached at the outer end at an angle of 45.0∘45.0^\circ above the horizontal. With no additional load, find the tension TT in the cable. (Use g=9.80 m/s2g = 9.80\text{ m/s}^2)

Answer

T=83.2 NT = 83.2\text{ N}. Set ∑τpivot=TLsin⁡(45.0∘)−mg(L2)=0\sum \tau_{\text{pivot}} = T L \sin(45.0^\circ) - mg\left(\frac{L}{2}\right) = 0. This gives T=mg2sin⁡(45.0∘)=(12.0)(9.80)2(0.7071)≈83.2 NT = \frac{mg}{2\sin(45.0^\circ)} = \frac{(12.0)(9.80)}{2(0.7071)} \approx 83.2\text{ N}.

02

A uniform shelf of length L=1.20 mL = 1.20\text{ m} and mass m=6.00 kgm = 6.00\text{ kg} is supported horizontally by a hinge at the left end and a vertical cable attached at a distance of 0.90 m0.90\text{ m} from the hinge. A concentrated box of mass M=15.0 kgM = 15.0\text{ kg} rests at the far right end (1.20 m1.20\text{ m}). Find the tension TT in the vertical cable. (Use g=9.80 m/s2g = 9.80\text{ m/s}^2)

Answer

T=235 NT = 235\text{ N}. Take torques about the hinge: ∑τ=T(0.90)−mg(0.60)−Mg(1.20)=0\sum \tau = T(0.90) - mg(0.60) - Mg(1.20) = 0. With mg=58.8 Nmg = 58.8\text{ N} and Mg=147 NMg = 147\text{ N}, T(0.90)=(58.8)(0.60)+(147)(1.20)=35.28+176.4=211.68 N⋅mT(0.90) = (58.8)(0.60) + (147)(1.20) = 35.28 + 176.4 = 211.68\text{ N}\cdot\text{m}. Thus T=211.680.90≈235 NT = \frac{211.68}{0.90} \approx 235\text{ N}.

03

A uniform boom of length L=4.00 mL = 4.00\text{ m} and mass m=50.0 kgm = 50.0\text{ kg} is tilted at an angle of 30.0∘30.0^\circ above the horizontal, hinged at its lower base OO. A horizontal tie-rope is attached to the upper tip of the boom. A load of mass M=100.0 kgM = 100.0\text{ kg} hangs vertically from the upper tip. Find the tension TT in the horizontal tie-rope. (Use g=9.80 m/s2g = 9.80\text{ m/s}^2)

Answer

T=2120 NT = 2120\text{ N}. Setting torques about pivot OO to zero: ∑τO=T(Lsin⁡30.0∘)−mg(L2cos⁡30.0∘)−Mg(Lcos⁡30.0∘)=0\sum \tau_O = T(L\sin 30.0^\circ) - mg\left(\frac{L}{2}\cos 30.0^\circ\right) - Mg(L\cos 30.0^\circ) = 0. Dividing by LL: Tsin⁡30.0∘=(12mg+Mg)cos⁡30.0∘T \sin 30.0^\circ = \left(\frac{1}{2}mg + Mg\right)\cos 30.0^\circ. With 12mg+Mg=245+980=1225 N\frac{1}{2}mg + Mg = 245 + 980 = 1225\text{ N}, T=1225cot⁡(30.0∘)=12253≈2122 NT = 1225\cot(30.0^\circ) = 1225\sqrt{3} \approx 2122\text{ N} (or 2120 N2120\text{ N} to 3 sig figs).

Loading workspace…