An industrial microelectronics heat sink features a square silicon base of width W=25.0 mmW = 25.0\text{ mm} and thickness t=750 μmt = 750\text{ }\mu\text{m} (kSi=148 W/(m⋅K)k_{\text{Si}} = 148\text{ W}/(\text{m}\cdot\text{K})). The base receives heat from an integrated circuit dissipating a heat flux of q′′=45.0 W/cm2q'' = 45.0\text{ W}/\text{cm}^2. The opposite face of the heat sink base is exposed to a coolant flow yielding a local convective heat transfer coefficient of h=3200 W/(m2⋅K)h = 3200\text{ W}/(\text{m}^2\cdot\text{K}) with bulk coolant temperature Tb=35.0∘CT_b = 35.0^{\circ}\text{C}. Converting all micro-scale and engineering units (q′′q'' in W/cm2\text{W}/\text{cm}^2, tt in μm\mu\text{m}, and WW in mm\text{mm}) into standard SI units: (a) determine the total thermal power Q˙\dot{Q} generated by the chip in watts (W\text{W}), and (b) calculate the peak operating junction temperature TjT_j at the base of the silicon chip.

Answer and steps

Final answer

(a) Q˙=281 W\dot{Q} = 281\text{ W}; (b) Tj=178∘CT_j = 178^{\circ}\text{C} (451 K451\text{ K}).

Steps

Part (a): Total Thermal Power Generated

  1. Convert parameters to standard SI units:

    • Width of the square base: W=25.0 mm=2.50×10−2 mW = 25.0\text{ mm} = 2.50 \times 10^{-2}\text{ m}
    • Surface area: A=W2=(2.50×10−2 m)2=6.25×10−4 m2=6.25 cm2A = W^2 = (2.50 \times 10^{-2}\text{ m})^2 = 6.25 \times 10^{-4}\text{ m}^2 = 6.25\text{ cm}^2
    • Thickness: t=750 μm=750×10−6 m=7.50×10−4 mt = 750\text{ }\mu\text{m} = 750 \times 10^{-6}\text{ m} = 7.50 \times 10^{-4}\text{ m}
    • Heat flux: q′′=45.0 W/cm2=45.0×104 W/m2=4.50×105 W/m2q'' = 45.0\text{ W}/\text{cm}^2 = 45.0 \times 10^4\text{ W}/\text{m}^2 = 4.50 \times 10^5\text{ W}/\text{m}^2
  2. Calculate the total heat transfer rate Q˙\dot{Q}: The total thermal power dissipated by the integrated circuit over area AA is given by: Q˙=q′′A\dot{Q} = q'' A Q˙=(45.0 W/cm2)(6.25 cm2)=281.25 W≈281 W\dot{Q} = (45.0\text{ W}/\text{cm}^2)(6.25\text{ cm}^2) = 281.25\text{ W} \approx 281\text{ W}

Part (b): Peak Operating Junction Temperature TjT_j

Under steady-state one-dimensional conditions, the heat generated passes through the silicon layer via conduction and is subsequently removed by fluid convection at the coolant interface.

  1. Thermal resistance network approach: The heat flux traverses two resistances in series:

    • Conduction resistance of the silicon base: Rcond′′=tkSiR''_{\text{cond}} = \frac{t}{k_{\text{Si}}}
    • Convection resistance at the fluid boundary: Rconv′′=1hR''_{\text{conv}} = \frac{1}{h}
  2. Calculate the individual temperature drops:

    • Temperature drop across the silicon base (ΔTcond\Delta T_{\text{cond}}): Using Fourier's Law of conduction: ΔTcond=Tj−Ts=q′′(tkSi)\Delta T_{\text{cond}} = T_j - T_s = q''\left(\frac{t}{k_{\text{Si}}}\right) ΔTcond=(4.50×105 W/m2)(7.50×10−4 m148 W/(m⋅K))≈2.28 K (or 2.28∘C)\Delta T_{\text{cond}} = (4.50 \times 10^5\text{ W}/\text{m}^2)\left(\frac{7.50 \times 10^{-4}\text{ m}}{148\text{ W}/(\text{m}\cdot\text{K})}\right) \approx 2.28\text{ K} \text{ (or } 2.28^{\circ}\text{C})
    • Temperature drop from the surface to the coolant (ΔTconv\Delta T_{\text{conv}}): Using Newton's Law of Cooling: ΔTconv=Ts−Tb=q′′h\Delta T_{\text{conv}} = T_s - T_b = \frac{q''}{h} ΔTconv=4.50×105 W/m23200 W/(m2⋅K)=140.625 K (or 140.63∘C)\Delta T_{\text{conv}} = \frac{4.50 \times 10^5\text{ W}/\text{m}^2}{3200\text{ W}/(\text{m}^2\cdot\text{K})} = 140.625\text{ K} \text{ (or } 140.63^{\circ}\text{C})
  3. Compute the junction temperature TjT_j: Summing the total temperature difference from the junction to the bulk coolant: Tj−Tb=ΔTcond+ΔTconv=2.28∘C+140.63∘C=142.91∘CT_j - T_b = \Delta T_{\text{cond}} + \Delta T_{\text{conv}} = 2.28^{\circ}\text{C} + 140.63^{\circ}\text{C} = 142.91^{\circ}\text{C} Tj=Tb+142.91∘C=35.0∘C+142.91∘C≈178∘CT_j = T_b + 142.91^{\circ}\text{C} = 35.0^{\circ}\text{C} + 142.91^{\circ}\text{C} \approx 178^{\circ}\text{C}

    In absolute temperature: Tj=177.91+273.15≈451 KT_j = 177.91 + 273.15 \approx 451\text{ K}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the conversion factor between centimeters and meters when converting heat flux from W/cm² to W/m², using 100 instead of 10000 and underestimating the power and temperature rise.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    W=0.025 m  ⟹  q′′=45.0 W/cm2=4500 W/m2  ⟹  A=(0.025 m)2=6.25×10−4 m2W = 0.025\text{ m} \implies q'' = 45.0\text{ W/cm}^2 = 4500\text{ W/m}^2 \implies A = (0.025\text{ m})^2 = 6.25 \times 10^{-4}\text{ m}^2

    Correct

    q′′=45.0 W/cm2=45.0×104 W/m2=4.50×105 W/m2q'' = 45.0\text{ W/cm}^2 = 45.0 \times 10^4\text{ W/m}^2 = 4.50 \times 10^5\text{ W/m}^2

    You converted the width and calculated the cross-sectional area correctly, but you multiplied the heat flux by 100100 instead of 10,00010{,}000. Because 1 cm=10−2 m1\text{ cm} = 10^{-2}\text{ m}, the square centimeter in the denominator converts as 1 cm2=(10−2 m)2=10−4 m21\text{ cm}^2 = (10^{-2}\text{ m})^2 = 10^{-4}\text{ m}^2, giving 45.0 W10−4 m2=4.50×105 W/m2\frac{45.0\text{ W}}{10^{-4}\text{ m}^2} = 4.50 \times 10^5\text{ W/m}^2.

  2. Step 2

    Q˙=q′′×A=(4500 W/m2)×(6.25×10−4 m2)=2.81 W\dot{Q} = q'' \times A = (4500\text{ W/m}^2) \times (6.25 \times 10^{-4}\text{ m}^2) = 2.81\text{ W}

    Correct

    Q˙=q′′A=(4.50×105 W/m2)(6.25×10−4 m2)≈281 W\dot{Q} = q'' A = (4.50 \times 10^5\text{ W/m}^2)(6.25 \times 10^{-4}\text{ m}^2) \approx 281\text{ W}

    You used the correct equation for heat rate, but the result is smaller by two orders of magnitude due to the earlier heat flux conversion error.

  3. Step 3

    Rcond=tk×A=7.50×10−4 m148 W/(m⋅K)×6.25×10−4 m2=0.0081 K/W  ⟹  Rconv=1h×A=13200 W/(m2⋅K)×6.25×10−4 m2=0.500 K/W  ⟹  Rtot=0.0081 K/W+0.500 K/W=0.5081 K/WR_{\text{cond}} = \frac{t}{k \times A} = \frac{7.50 \times 10^{-4}\text{ m}}{148\text{ W/(m}\cdot\text{K)} \times 6.25 \times 10^{-4}\text{ m}^2} = 0.0081\text{ K/W} \implies R_{\text{conv}} = \frac{1}{h \times A} = \frac{1}{3200\text{ W/(m}^2\cdot\text{K)} \times 6.25 \times 10^{-4}\text{ m}^2} = 0.500\text{ K/W} \implies R_{\text{tot}} = 0.0081\text{ K/W} + 0.500\text{ K/W} = 0.5081\text{ K/W}

  4. Step 4

    ΔT=Q˙×Rtot=(2.81 W)×(0.5081 K/W)=1.43∘C  ⟹  Tj=35.0∘C+1.43∘C=36.4∘C\Delta T = \dot{Q} \times R_{\text{tot}} = (2.81\text{ W}) \times (0.5081\text{ K/W}) = 1.43^{\circ}\text{C} \implies T_j = 35.0^{\circ}\text{C} + 1.43^{\circ}\text{C} = 36.4^{\circ}\text{C}

    Correct

    ΔT=Q˙Rtot=(281.25 W)(0.5081 K/W)≈142.9∘C  ⟹  Tj=35.0∘C+142.9∘C≈178∘C\Delta T = \dot{Q} R_{\text{tot}} = (281.25\text{ W})(0.5081\text{ K/W}) \approx 142.9^{\circ}\text{C} \implies T_j = 35.0^{\circ}\text{C} + 142.9^{\circ}\text{C} \approx 178^{\circ}\text{C}

    You applied the thermal Ohm's law relation correctly to obtain the junction temperature, but the numerical answer inherits the value of Q˙\dot{Q} from Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the cross-sectional area of the heat sink base in square meters.

You accurately identified and evaluated the individual thermal resistance formulas for conduction and convection.

You correctly applied the series thermal resistance concept and the relationship between heat rate, total resistance, and temperature difference.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Conversion Error

You converted from cm2\text{cm}^2 to m2\text{m}^2 using a factor of 100100 instead of 1002=10,000100^2 = 10{,}000.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Forgetting that dimensional scaling applies to exponents in derived units. When converting an area unit in the denominator, (1 cm)−2=(10−2 m)−2=104 m−2(1\text{ cm})^{-2} = (10^{-2}\text{ m})^{-2} = 10^4\text{ m}^{-2}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Denominator Area Conversion
  • 1 cm2=(10−2 m)2=10−4 m21\text{ cm}^2 = (10^{-2}\text{ m})^2 = 10^{-4}\text{ m}^2, so 1 W/cm2=1 W10−4 m2=104 W/m21\text{ W/cm}^2 = \frac{1\text{ W}}{10^{-4}\text{ m}^2} = 10^4\text{ W/m}^2.

  • Always write out (10−2 m)2(10^{-2}\text{ m})^2 explicitly with parentheses before evaluating units raised to powers.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Use the corrected heat flux q′′=4.50×105 W/m2q'' = 4.50 \times 10^5\text{ W/m}^2 to calculate Q˙=q′′A=(4.50×105 W/m2)(6.25×10−4 m2)=281.25 W≈281 W\dot{Q} = q'' A = (4.50 \times 10^5\text{ W/m}^2)(6.25 \times 10^{-4}\text{ m}^2) = 281.25\text{ W} \approx 281\text{ W}.

  2. Multiply the true heat rate by the total thermal resistance: ΔT=(281.25 W)(0.5081 K/W)=142.9∘C\Delta T = (281.25\text{ W})(0.5081\text{ K/W}) = 142.9^{\circ}\text{C}.

  3. Add the temperature drop to the coolant temperature: Tj=35.0∘C+142.9∘C=177.9∘C≈178∘CT_j = 35.0^{\circ}\text{C} + 142.9^{\circ}\text{C} = 177.9^{\circ}\text{C} \approx 178^{\circ}\text{C} (or 451 K451\text{ K}).

Final answer

(a) Q˙=281 W\dot{Q} = 281\text{ W}; (b) Tj=178∘CT_j = 178^{\circ}\text{C} (451 K451\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review unit conversions involving square and cubic prefixes using bracketed dimensional analysis.

  • Check that physical results are realistic: a chip dissipating 45 W/cm245\text{ W/cm}^2 on a 2.5 cm×2.5 cm2.5\text{ cm} \times 2.5\text{ cm} die should generate several hundred watts, not under 3 W3\text{ W}.

OverviewACEpath Teacher's Diagnosis

02 The student accounts only for convective resistance to the fluid, completely omitting the conductive resistance through the silicon base.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    W=0.025 m  ⟹  A=(0.025 m)2=6.25×10−4 m2  ⟹  q′′=4.50×105 W/m2  ⟹  Q˙=q′′×A=281.25 WW = 0.025\text{ m} \implies A = (0.025\text{ m})^2 = 6.25 \times 10^{-4}\text{ m}^2 \implies q'' = 4.50 \times 10^5\text{ W/m}^2 \implies \dot{Q} = q'' \times A = 281.25\text{ W}

  2. Step 2

    Rconv=1h×A=13200 W/(m2⋅K)×6.25×10−4 m2=0.500 K/WR_{\text{conv}} = \frac{1}{h \times A} = \frac{1}{3200\text{ W/(m}^2\cdot\text{K)} \times 6.25 \times 10^{-4}\text{ m}^2} = 0.500\text{ K/W}

    Correct

    Rtot=Rcond+Rconv=tkSiA+1hA=8.11×10−3 K/W+0.500 K/W≈0.5081 K/WR_{\text{tot}} = R_{\text{cond}} + R_{\text{conv}} = \frac{t}{k_{\text{Si}} A} + \frac{1}{h A} = 8.11 \times 10^{-3}\text{ K/W} + 0.500\text{ K/W} \approx 0.5081\text{ K/W}

    While your convective resistance value of 0.500 K/W0.500\text{ K/W} is numerically correct, heat must first conduct through the thickness of the silicon base before reaching the coolant. You need to include the conduction resistance Rcond=tkSiAR_{\text{cond}} = \frac{t}{k_{\text{Si}} A} in series with RconvR_{\text{conv}}.

  3. Step 3

    ΔT=Q˙×Rconv=281.25 W×0.500 K/W=140.6∘C  ⟹  Tj=Tb+ΔT=35.0∘C+140.6∘C=175.6∘C\Delta T = \dot{Q} \times R_{\text{conv}} = 281.25\text{ W} \times 0.500\text{ K/W} = 140.6^{\circ}\text{C} \implies T_j = T_b + \Delta T = 35.0^{\circ}\text{C} + 140.6^{\circ}\text{C} = 175.6^{\circ}\text{C}

    Correct

    ΔT=Q˙Rtot=ΔTcond+ΔTconv≈2.28∘C+140.63∘C=142.91∘C  ⟹  Tj=35.0∘C+142.91∘C≈178∘C\Delta T = \dot{Q} R_{\text{tot}} = \Delta T_{\text{cond}} + \Delta T_{\text{conv}} \approx 2.28^{\circ}\text{C} + 140.63^{\circ}\text{C} = 142.91^{\circ}\text{C} \implies T_j = 35.0^{\circ}\text{C} + 142.91^{\circ}\text{C} \approx 178^{\circ}\text{C} (451 K451\text{ K})

    Because the conductive temperature rise across the silicon substrate was left out of ΔT\Delta T, your final junction temperature was missing about 2.3∘C2.3^{\circ}\text{C}.

WHAT YOU DID WELL
Compliments from Your Teacher

You handled all micro-scale and engineering unit conversions cleanly.

You correctly calculated the total dissipated thermal power Q˙=281.25 W\dot{Q} = 281.25\text{ W}.

You set up and calculated the fluid convective thermal resistance accurately using Newton's Law of Cooling.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of conductive thermal resistance in series

You calculated the temperature drop across the fluid boundary layer correctly, but you overlooked the temperature drop across the solid silicon substrate.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating heat transfer through a composite solid-fluid path as a single-resistance convection problem rather than a two-element series thermal resistance network (Rtot=Rcond+RconvR_{\text{tot}} = R_{\text{cond}} + R_{\text{conv}}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Trace the Physical Heat Path
  • Whenever heat flows from an internal heat source through solid walls to an external coolant, the total resistance is the sum of all conduction and convection resistances in series: Rtot=∑Rcond+∑RconvR_{\text{tot}} = \sum R_{\text{cond}} + \sum R_{\text{conv}}.

  • Always sketch a 1D thermal resistance circuit from the junction (TjT_j) to the bulk fluid (TbT_b) before computing ΔT\Delta T.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the conduction resistance of the silicon base: Rcond=tkSiA=7.50×10−4 m(148 W/(m⋅K))(6.25×10−4 m2)≈8.108×10−3 K/WR_{\text{cond}} = \frac{t}{k_{\text{Si}} A} = \frac{7.50 \times 10^{-4}\text{ m}}{(148\text{ W}/(\text{m}\cdot\text{K}))(6.25 \times 10^{-4}\text{ m}^2)} \approx 8.108 \times 10^{-3}\text{ K/W}.

  2. Find the total series thermal resistance: Rtot=Rcond+Rconv=8.108×10−3 K/W+0.500 K/W≈0.5081 K/WR_{\text{tot}} = R_{\text{cond}} + R_{\text{conv}} = 8.108 \times 10^{-3}\text{ K/W} + 0.500\text{ K/W} \approx 0.5081\text{ K/W}.

  3. Compute the total temperature drop: ΔTtot=Q˙Rtot=281.25 W×0.5081 K/W≈142.9∘C\Delta T_{\text{tot}} = \dot{Q} R_{\text{tot}} = 281.25\text{ W} \times 0.5081\text{ K/W} \approx 142.9^{\circ}\text{C}.

  4. Calculate the junction temperature: Tj=Tb+ΔTtot=35.0∘C+142.9∘C≈177.9∘C≈178∘CT_j = T_b + \Delta T_{\text{tot}} = 35.0^{\circ}\text{C} + 142.9^{\circ}\text{C} \approx 177.9^{\circ}\text{C} \approx 178^{\circ}\text{C} (451 K451\text{ K}).

Final answer

(a) Q˙=281 W\dot{Q} = 281\text{ W}; (b) Tj=178∘CT_j = 178^{\circ}\text{C} (451 K451\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Draw an equivalent electrical resistance diagram showing nodes Tj→Ts→TbT_j \to T_s \to T_b before writing down formulas.

  • Practice identifying all media between the heat source and heat sink to ensure no conductive, convective, or contact resistances are skipped.

OverviewACEpath Teacher's Diagnosis

03 The student misinterprets the metric prefix micro (μ) as 10⁻³ instead of 10⁻⁶ when converting the base thickness, artificially inflating the conductive resistance and predicted junction temperature.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    W=0.025 m  ⟹  A=(0.025 m)2=6.25×10−4 m2  ⟹  q′′=45.0 W/cm2=4.50×105 W/m2  ⟹  Q˙=q′′×A=(4.50×105 W/m2)×(6.25×10−4 m2)=281.25 WW = 0.025\text{ m} \implies A = (0.025\text{ m})^2 = 6.25 \times 10^{-4}\text{ m}^2 \implies q'' = 45.0\text{ W}/\text{cm}^2 = 4.50 \times 10^5\text{ W}/\text{m}^2 \implies \dot{Q} = q'' \times A = (4.50 \times 10^5\text{ W}/\text{m}^2) \times (6.25 \times 10^{-4}\text{ m}^2) = 281.25\text{ W}

  2. Step 2

    t=750 μm=0.750 m  ⟹  Rcond=tk×A=0.750 m148 W/(m⋅K)×6.25×10−4 m2=8.11 K/Wt = 750\text{ }\mu\text{m} = 0.750\text{ m} \implies R_{\text{cond}} = \frac{t}{k \times A} = \frac{0.750\text{ m}}{148\text{ W}/(\text{m}\cdot\text{K}) \times 6.25 \times 10^{-4}\text{ m}^2} = 8.11\text{ K}/\text{W}

    Correct

    t=750 μm=750×10−6 m=7.50×10−4 m  ⟹  Rcond=7.50×10−4 m(148 W/(m⋅K))(6.25×10−4 m2)≈0.00811 K/Wt = 750\text{ }\mu\text{m} = 750 \times 10^{-6}\text{ m} = 7.50 \times 10^{-4}\text{ m} \implies R_{\text{cond}} = \frac{7.50 \times 10^{-4}\text{ m}}{(148\text{ W}/(\text{m}\cdot\text{K}))(6.25 \times 10^{-4}\text{ m}^2)} \approx 0.00811\text{ K}/\text{W}

    You treated 1 μm1\text{ }\mu\text{m} as 10−3 m10^{-3}\text{ m} (equivalent to millimeters) instead of 10−6 m10^{-6}\text{ m}. A thickness of 0.750 m0.750\text{ m} is 75 cm75\text{ cm}, which is far too thick for a silicon micro-chip layer and made RcondR_{\text{cond}} 1000 times larger than its true value.

  3. Step 3

    Rconv=1h×A=13200 W/(m2⋅K)×6.25×10−4 m2=0.500 K/WR_{\text{conv}} = \frac{1}{h \times A} = \frac{1}{3200\text{ W}/(\text{m}^2\cdot\text{K}) \times 6.25 \times 10^{-4}\text{ m}^2} = 0.500\text{ K}/\text{W}

  4. Step 4

    Rtot=8.11 K/W+0.500 K/W=8.61 K/W  ⟹  ΔT=Q˙×Rtot=281.25 W×8.61 K/W=2422∘C  ⟹  Tj=35.0∘C+2422∘C=2457∘CR_{\text{tot}} = 8.11\text{ K}/\text{W} + 0.500\text{ K}/\text{W} = 8.61\text{ K}/\text{W} \implies \Delta T = \dot{Q} \times R_{\text{tot}} = 281.25\text{ W} \times 8.61\text{ K}/\text{W} = 2422^{\circ}\text{C} \implies T_j = 35.0^{\circ}\text{C} + 2422^{\circ}\text{C} = 2457^{\circ}\text{C}

    Correct

    Rtot=0.00811 K/W+0.500 K/W=0.50811 K/W  ⟹  ΔT=(281.25 W)(0.50811 K/W)≈142.9∘C  ⟹  Tj=35.0∘C+142.9∘C≈178∘CR_{\text{tot}} = 0.00811\text{ K}/\text{W} + 0.500\text{ K}/\text{W} = 0.50811\text{ K}/\text{W} \implies \Delta T = (281.25\text{ W})(0.50811\text{ K}/\text{W}) \approx 142.9^{\circ}\text{C} \implies T_j = 35.0^{\circ}\text{C} + 142.9^{\circ}\text{C} \approx 178^{\circ}\text{C}

    Your thermal circuit combination and temperature summation logic were completely sound, but the final numerical value was inflated due to the thickness conversion error from Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly determined the surface area AA and converted the heat flux q′′q'' from W/cm2\text{W}/\text{cm}^2 to W/m2\text{W}/\text{m}^2.

You accurately calculated the total heat dissipation rate Q˙=281.25 W\dot{Q} = 281.25\text{ W}.

You correctly identified that conduction and convection act in series, summing their thermal resistances to find the total temperature difference.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric prefix confusion (micro vs. milli)

You converted 750 μm750\text{ }\mu\text{m} to 0.750 m0.750\text{ m} by dividing by 10310^3 instead of 10610^6.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the metric prefix micro (μ=10−6\mu = 10^{-6}) with milli (m=10−3\text{m} = 10^{-3}). Whenever working with silicon wafers or thin foils, checking the physical plausibility of the dimension (0.75 m=75 cm0.75\text{ m} = 75\text{ cm}, which is the length of a desk rather than the thickness of a chip) can immediately reveal this prefix slip.

REASONING PATH
Your ACEpath teacher’s suggested approach
Metric Prefix Definition
  • 1 μm=10−6 m=10−3 mm1\text{ }\mu\text{m} = 10^{-6}\text{ m} = 10^{-3}\text{ mm}

  • Always replace μ\mu directly with ×10−6\times 10^{-6} when moving to standard SI base units.

Physical Reasonableness of Conduction in Thin Substrates
  • Highly conductive, sub-millimeter substrates typically present a negligible resistance compared to fluid convection.

  • Compare RcondR_{\text{cond}} and RconvR_{\text{conv}}. For a 750 μm750\text{ }\mu\text{m} silicon base, Rcond≈0.008 K/WR_{\text{cond}} \approx 0.008\text{ K}/\text{W}, which is roughly 1.6%1.6\% of Rconv=0.500 K/WR_{\text{conv}} = 0.500\text{ K}/\text{W}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert thickness: t=750 μm=750×10−6 m=7.50×10−4 mt = 750\text{ }\mu\text{m} = 750 \times 10^{-6}\text{ m} = 7.50 \times 10^{-4}\text{ m}.

  2. Calculate conductive resistance: Rcond=tkA=7.50×10−4 m(148 W/(m⋅K))(6.25×10−4 m2)=8.108×10−3 K/WR_{\text{cond}} = \frac{t}{k A} = \frac{7.50 \times 10^{-4}\text{ m}}{(148\text{ W}/(\text{m}\cdot\text{K}))(6.25 \times 10^{-4}\text{ m}^2)} = 8.108 \times 10^{-3}\text{ K}/\text{W}.

  3. Calculate total thermal resistance: Rtot=Rcond+Rconv=0.00811 K/W+0.500 K/W=0.50811 K/WR_{\text{tot}} = R_{\text{cond}} + R_{\text{conv}} = 0.00811\text{ K}/\text{W} + 0.500\text{ K}/\text{W} = 0.50811\text{ K}/\text{W}.

  4. Calculate peak junction temperature: Tj=Tb+Q˙Rtot=35.0∘C+(281.25 W)(0.50811 K/W)=35.0∘C+142.91∘C=177.91∘C≈178∘CT_j = T_b + \dot{Q} R_{\text{tot}} = 35.0^{\circ}\text{C} + (281.25\text{ W})(0.50811\text{ K}/\text{W}) = 35.0^{\circ}\text{C} + 142.91^{\circ}\text{C} = 177.91^{\circ}\text{C} \approx 178^{\circ}\text{C}.

Final answer

(a) Q˙=281 W\dot{Q} = 281\text{ W}; (b) Tj=178∘CT_j = 178^{\circ}\text{C} (or 451 K451\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the SI prefix scale from pico (10−1210^{-12}) up to mega (10610^6), paying close attention to micro (10−610^{-6}) versus milli (10−310^{-3}).

  • Practice converting compound micro-units such as μm\mu\text{m} to m\text{m} and W/cm2\text{W}/\text{cm}^2 to W/m2\text{W}/\text{m}^2 using explicit unit cancellation fractions.

  • Solve the three targeted follow-up problems below to reinforce thermal circuit analysis.

Lock it in

Similar question

01

A semiconductor diode has an active surface of 4.0 mm24.0\text{ mm}^2 and dissipates heat at a uniform flux of 12.5 W/cm212.5\text{ W}/\text{cm}^2. Determine the total heat dissipated Q˙\dot{Q} in watts.

Answer

Q˙=0.50 W\dot{Q} = 0.50\text{ W}. Key steps: Convert area A=4.0 mm2=4.0×10−6 m2A = 4.0\text{ mm}^2 = 4.0 \times 10^{-6}\text{ m}^2; convert heat flux q′′=12.5 W/cm2=1.25×105 W/m2q'' = 12.5\text{ W}/\text{cm}^2 = 1.25 \times 10^5\text{ W}/\text{m}^2; calculate Q˙=q′′A=(1.25×105)(4.0×10−6)=0.50 W\dot{Q} = q'' A = (1.25 \times 10^5)(4.0 \times 10^{-6}) = 0.50\text{ W}.

02

A flat silicon plate (k=150 W/(m⋅K)k = 150\text{ W}/(\text{m}\cdot\text{K})) of thickness t=1.2 mmt = 1.2\text{ mm} is heated on one side with a heat flux of q′′=30.0 W/cm2q'' = 30.0\text{ W}/\text{cm}^2. If the back face is held at 40.0∘C40.0^{\circ}\text{C}, find the temperature of the heated front face.

Answer

Tfront=42.4∘CT_{\text{front}} = 42.4^{\circ}\text{C}. Key steps: Convert q′′=30.0×104 W/m2=3.0×105 W/m2q'' = 30.0 \times 10^4\text{ W}/\text{m}^2 = 3.0 \times 10^5\text{ W}/\text{m}^2 and t=1.2×10−3 mt = 1.2 \times 10^{-3}\text{ m}; conductive temperature drop ΔT=q′′(t/k)=(3.0×105)(1.2×10−3/150)=2.4 K\Delta T = q''(t/k) = (3.0 \times 10^5)(1.2 \times 10^{-3}/150) = 2.4\text{ K}; front temperature Tfront=40.0∘C+2.4∘C=42.4∘CT_{\text{front}} = 40.0^{\circ}\text{C} + 2.4^{\circ}\text{C} = 42.4^{\circ}\text{C}.

03

A high-power LED module with a square base of side length L=10.0 mmL = 10.0\text{ mm} dissipates 25.0 W25.0\text{ W}. The base has thickness t=500 μmt = 500\text{ }\mu\text{m} (k=200 W/(m⋅K)k = 200\text{ W}/(\text{m}\cdot\text{K})) and is cooled by air with h=250 W/(m2⋅K)h = 250\text{ W}/(\text{m}^2\cdot\text{K}) at T∞=25.0∘CT_{\infty} = 25.0^{\circ}\text{C}. Find the junction temperature TjT_j.

Answer

Tj=1025.6∘CT_j = 1025.6^{\circ}\text{C} (or ≈1026∘C\approx 1026^{\circ}\text{C}). Key steps: Area A=(0.010 m)2=1.0×10−4 m2A = (0.010\text{ m})^2 = 1.0 \times 10^{-4}\text{ m}^2; Rcond=t/(kA)=(500×10−6)/(200×1.0×10−4)=0.025 K/WR_{\text{cond}} = t/(kA) = (500 \times 10^{-6})/(200 \times 1.0 \times 10^{-4}) = 0.025\text{ K/W}; Rconv=1/(hA)=1/(250×1.0×10−4)=40.0 K/WR_{\text{conv}} = 1/(hA) = 1/(250 \times 1.0 \times 10^{-4}) = 40.0\text{ K/W}; total resistance Rtot=40.025 K/WR_{\text{tot}} = 40.025\text{ K/W}; temperature drop ΔT=Q˙Rtot=25.0×40.025=1000.6∘C\Delta T = \dot{Q} R_{\text{tot}} = 25.0 \times 40.025 = 1000.6^{\circ}\text{C}; junction temperature Tj=25.0∘C+1000.6∘C=1025.6∘CT_j = 25.0^{\circ}\text{C} + 1000.6^{\circ}\text{C} = 1025.6^{\circ}\text{C}.