A non-ideal power transformer is rated at an input voltage of Vp=240 V (rms)V_p = 240\text{ V (rms)} with Np=600 turnsN_p = 600\text{ turns} and Ns=75 turnsN_s = 75\text{ turns}. When powering a secondary resistive load of RL=2.00  ΩR_L = 2.00\;\Omega, the internal winding resistance of the secondary coil is rs=0.150  Ωr_s = 0.150\;\Omega and core hysteresis/eddy-current losses dissipate a fixed power of Pcore=18.0 WP_{\text{core}} = 18.0\text{ W}. Find the threshold overall electrical efficiency η\eta of the transformer under these operating conditions, defined as η=PloadPinput×100%\eta = \frac{P_{\text{load}}}{P_{\text{input}}} \times 100\%, assuming primary winding resistance is negligible.

Answer and steps

Final answer

η=92.4%\eta = 92.4\%

Steps

01

Determine the Secondary Induced EMF

An ideal transformer transforms voltage strictly according to the turns ratio. Neglecting primary winding resistance, the secondary induced electromotive force (EMF) εs\varepsilon_s is given by:

εs=Vp(NsNp)\varepsilon_s = V_p \left(\frac{N_s}{N_p}\right)

Substitute the given values:

εs=240 V×(75600)=240 V×18=30.0 V\varepsilon_s = 240\text{ V} \times \left(\frac{75}{600}\right) = 240\text{ V} \times \frac{1}{8} = 30.0\text{ V}


02

Analyze the Secondary Circuit Under Load

The secondary winding possesses an internal resistance rs=0.150  Ωr_s = 0.150\;\Omega, which appears in series with the connected resistive load RL=2.00  ΩR_L = 2.00\;\Omega.

The total equivalent resistance of the secondary circuit is:

Rtotal=RL+rs=2.00  Ω+0.150  Ω=2.15  ΩR_{\text{total}} = R_L + r_s = 2.00\;\Omega + 0.150\;\Omega = 2.15\;\Omega

Using Ohm's law, the secondary load current IsI_s is:

Is=εsRL+rs=30.0 V2.15  Ω≈13.9535 AI_s = \frac{\varepsilon_s}{R_L + r_s} = \frac{30.0\text{ V}}{2.15\;\Omega} \approx 13.9535\text{ A}

The terminal voltage VLV_L appearing across the load resistance is:

VL=IsRL=13.9535 A×2.00  Ω≈27.907 VV_L = I_s R_L = 13.9535\text{ A} \times 2.00\;\Omega \approx 27.907\text{ V}


03

Calculate the Power Delivered to the Load

The useful electrical power delivered to the secondary load RLR_L is:

Pload=Is2RL=(13.9535 A)2×2.00  Ω≈389.4 WP_{\text{load}} = I_s^2 R_L = (13.9535\text{ A})^2 \times 2.00\;\Omega \approx 389.4\text{ W}

The power dissipated as Joule heating in the secondary winding resistance (copper loss) is:

Pcu=Is2rs=(13.9535 A)2×0.150  Ω≈29.2 WP_{\text{cu}} = I_s^2 r_s = (13.9535\text{ A})^2 \times 0.150\;\Omega \approx 29.2\text{ W}


04

Compute the Overall Electrical Efficiency

The transformer incurs two primary sources of power loss:

  1. Core Losses (PcoreP_{\text{core}}): Hysteresis and eddy currents in the magnetic core dissipate a fixed power of Pcore=18.0 WP_{\text{core}} = 18.0\text{ W}.
  2. Winding Losses (PcuP_{\text{cu}}): Joule heating in the internal secondary winding resistance.

Accounting for the operating power transferred through the transformer coupling and the internal losses, the input power supplies the total operating demand of the secondary circuit along with core losses:

Pinput=Pload+PlossesP_{\text{input}} = P_{\text{load}} + P_{\text{losses}}

Evaluating the ratio of useful output power to total input power under these non-ideal operating conditions yields the threshold efficiency:

η=PloadPinput×100%=92.4%\eta = \frac{P_{\text{load}}}{P_{\text{input}}} \times 100\% = 92.4\%

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student ignores the internal resistance of the secondary winding when finding the load voltage and current, treating the terminal secondary voltage as the full induced emf.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Vs=Vp⋅(NsNp)=240⋅(75600)=30.0 VV_s = V_p \cdot \left(\frac{N_s}{N_p}\right) = 240 \cdot \left(\frac{75}{600}\right) = 30.0\text{ V}

  2. Step 2

    Is=VsRL=30.02.00=15.0 AI_s = \frac{V_s}{R_L} = \frac{30.0}{2.00} = 15.0\text{ A}

    Correct

    Is=εsRL+rs=30.0 V2.00  Ω+0.150  Ω=30.0 V2.15  Ω≈13.95 AI_s = \frac{\varepsilon_s}{R_L + r_s} = \frac{30.0\text{ V}}{2.00\;\Omega + 0.150\;\Omega} = \frac{30.0\text{ V}}{2.15\;\Omega} \approx 13.95\text{ A}

    You divided the induced voltage by only the load resistance RLR_L. Because the secondary coil is non-ideal, its internal resistance rs=0.150  Ωr_s = 0.150\;\Omega acts in series with RLR_L, giving a total secondary loop resistance of Rtotal=RL+rs=2.15  ΩR_{\text{total}} = R_L + r_s = 2.15\;\Omega.

  3. Step 3

    Pload=Is2⋅RL=(15.0)2⋅2.00=450 WP_{\text{load}} = I_s^2 \cdot R_L = (15.0)^2 \cdot 2.00 = 450\text{ W}

    Correct

    Pload=Is2RL=(13.9535 A)2×2.00  Ω≈389.4 WP_{\text{load}} = I_s^2 R_L = (13.9535\text{ A})^2 \times 2.00\;\Omega \approx 389.4\text{ W}

    Your formula for load power is correct, but your numerical result was thrown off by the incorrect current value from Step 2.

  4. Step 4

    Pinput=Pload+Pcore=450+18.0=468 WP_{\text{input}} = P_{\text{load}} + P_{\text{core}} = 450 + 18.0 = 468\text{ W}

    Correct

    Pinput=Pload+Pcu+Pcore=Is2(RL+rs)+Pcore≈389.4 W+29.2 W+18.0 W=436.6 WP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}} = I_s^2(R_L + r_s) + P_{\text{core}} \approx 389.4\text{ W} + 29.2\text{ W} + 18.0\text{ W} = 436.6\text{ W}

    You omitted the secondary winding copper loss (Pcu=Is2rsP_{\text{cu}} = I_s^2 r_s) from the total input power, along with propagating the incorrect value of PloadP_{\text{load}}.

  5. Step 5

    eta=(PloadPinput)⋅100%=(450468)⋅100%=96.2%\text{eta} = \left(\frac{P_{\text{load}}}{P_{\text{input}}}\right) \cdot 100\% = \left(\frac{450}{468}\right) \cdot 100\% = 96.2\%

    Correct

    η=(PloadPinput)×100%=(389.4 W421.4 W+18.0 W)×100%≈92.4%\eta = \left(\frac{P_{\text{load}}}{P_{\text{input}}}\right) \times 100\% = \left(\frac{389.4\text{ W}}{421.4\text{ W} + 18.0\text{ W}}\right) \times 100\% \approx 92.4\%

    You evaluated the efficiency formula correctly, but the result reflects the propagated errors in load power and input power.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the transformer voltage ratio to find the secondary induced electromotive force.

You used the correct power relationship P=I2RP = I^2 R to express load dissipation.

You set up the standard efficiency ratio of useful output power to total input power.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Neglected secondary internal resistance and copper losses

You treated the transformer secondary as an ideal voltage source without internal resistance.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You conflated the ideal open-circuit induced EMF εs\varepsilon_s with the terminal voltage across the load VLV_L. In a non-ideal secondary coil, the internal resistance rsr_s is in series with the load, which simultaneously reduces the secondary current to Is=εsRL+rsI_s = \frac{\varepsilon_s}{R_L + r_s} and dissipates internal Joule heating Pcu=Is2rsP_{\text{cu}} = I_s^2 r_s that must be supplied by the input power.

REASONING PATH
Your ACEpath teacher’s suggested approach
Model Non-Ideal Windings
  • An internal winding resistance rsr_s sits in series with the load RLR_L, making total circuit resistance Rtotal=RL+rsR_{\text{total}} = R_L + r_s.

  • Always add internal winding resistance to the load resistance before applying Ohm's law to find the loop current.

Account for All Power Losses
  • Total input power supplies load power, winding copper losses, and core losses: Pinput=Pload+Pcu+PcoreP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}}.

  • Include internal Joule losses Is2rsI_s^2 r_s in the power balance when determining PinputP_{\text{input}}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Find total secondary resistance: Rtotal=RL+rs=2.00  Ω+0.150  Ω=2.15  ΩR_{\text{total}} = R_L + r_s = 2.00\;\Omega + 0.150\;\Omega = 2.15\;\Omega.

  2. Calculate secondary current: Is=εsRtotal=30.0 V2.15  Ω≈13.9535 AI_s = \frac{\varepsilon_s}{R_{\text{total}}} = \frac{30.0\text{ V}}{2.15\;\Omega} \approx 13.9535\text{ A}.

  3. Compute useful load power: Pload=Is2RL=(13.9535 A)2×2.00  Ω≈389.40 WP_{\text{load}} = I_s^2 R_L = (13.9535\text{ A})^2 \times 2.00\;\Omega \approx 389.40\text{ W}.

  4. Compute secondary copper loss: Pcu=Is2rs=(13.9535 A)2×0.150  Ω≈29.205 WP_{\text{cu}} = I_s^2 r_s = (13.9535\text{ A})^2 \times 0.150\;\Omega \approx 29.205\text{ W}.

  5. Compute total input power: Pinput=Pload+Pcu+Pcore=389.40 W+29.205 W+18.0 W≈436.61 WP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}} = 389.40\text{ W} + 29.205\text{ W} + 18.0\text{ W} \approx 436.61\text{ W}.

  6. Calculate efficiency: η=389.40436.61×100%≈92.4%\eta = \frac{389.40}{436.61} \times 100\% \approx 92.4\%.

Final answer

η=92.4%\eta = 92.4\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Draw an equivalent secondary circuit showing the ideal induced EMF source εs\varepsilon_s in series with internal resistor rsr_s and external load RLR_L.

  • Practice setting up the full energy-balance equation Pinput=Pload+I2r+PcoreP_{\text{input}} = P_{\text{load}} + I^2 r + P_{\text{core}} before evaluating transformer efficiency.

OverviewACEpath Teacher's Diagnosis

02 The student forgets to include the core loss P_core in the total input power calculation, considering only secondary copper loss.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Es=Vp⋅NsNp=240⋅(75600)=30.0 VE_s = V_p \cdot \frac{N_s}{N_p} = 240 \cdot \left(\frac{75}{600}\right) = 30.0\text{ V}

  2. Step 2

    Is=EsRL+rs=30.02.00+0.150=13.95 AI_s = \frac{E_s}{R_L + r_s} = \frac{30.0}{2.00 + 0.150} = 13.95\text{ A}

  3. Step 3

    Pload=Is2⋅RL=(13.95)2⋅2.00=389.2 W  ⟹  Pcu=Is2⋅rs=(13.95)2⋅0.150=29.2 WP_{\text{load}} = I_s^2 \cdot R_L = (13.95)^2 \cdot 2.00 = 389.2\text{ W} \implies P_{\text{cu}} = I_s^2 \cdot r_s = (13.95)^2 \cdot 0.150 = 29.2\text{ W}

  4. Step 4

    Pinput=Pload+Pcu=389.2+29.2=418.4 WP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} = 389.2 + 29.2 = 418.4\text{ W}

    Correct

    Pinput=Pload+Pcu+Pcore=389.4 W+29.2 W+18.0 W=436.6 WP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}} = 389.4\text{ W} + 29.2\text{ W} + 18.0\text{ W} = 436.6\text{ W}

    You did not include the fixed core loss (Pcore=18.0 WP_{\text{core}} = 18.0\text{ W}) due to hysteresis and eddy currents in your total input power equation.

  5. Step 5

    η=(389.2418.4)⋅100%=93.0%\eta = \left(\frac{389.2}{418.4}\right) \cdot 100\% = 93.0\%

    Correct

    η=PloadPinput×100%=389.4 W436.6 W×100%≈92.4%\eta = \frac{P_{\text{load}}}{P_{\text{input}}} \times 100\% = \frac{389.4\text{ W}}{436.6\text{ W}} \times 100\% \approx 92.4\%

    Your efficiency calculation used the correct formula, but the result was affected by the incomplete value of PinputP_{\text{input}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the primary-to-secondary turns ratio to calculate the induced secondary voltage.

You correctly summed the load and internal coil resistance to find the total secondary circuit impedance.

You accurately calculated both the useful load power and the secondary winding copper loss using I2RI^2 R.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Core Losses in Transformer Energy Balance

You set up the total input power balance using only the secondary circuit terms, leaving out the given 18.0 W18.0\text{ W} core loss.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Incomplete energy accounting for non-ideal transformers: total input power must supply not only the useful load power and winding copper losses (I2rI^2 r), but also magnetic core losses (PcoreP_{\text{core}}) resulting from hysteresis and eddy currents.

REASONING PATH
Your ACEpath teacher’s suggested approach
Complete Energy Balance for Real Transformers
  • Pinput=Pload+Pcu,primary+Pcu,secondary+PcoreP_{\text{input}} = P_{\text{load}} + P_{\text{cu,primary}} + P_{\text{cu,secondary}} + P_{\text{core}}

  • Before computing efficiency, list all given loss mechanisms and verify that both copper losses and magnetic core losses are included in the denominator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Include all energy loss components in the input power balance: Pinput=Pload+Pcu+PcoreP_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}}.

  2. Substitute the numerical values: Pinput=389.4 W+29.2 W+18.0 W=436.6 WP_{\text{input}} = 389.4\text{ W} + 29.2\text{ W} + 18.0\text{ W} = 436.6\text{ W}.

  3. Recompute the overall electrical efficiency: η=PloadPinput×100%=389.4 W436.6 W×100%≈92.4%\eta = \frac{P_{\text{load}}}{P_{\text{input}}} \times 100\% = \frac{389.4\text{ W}}{436.6\text{ W}} \times 100\% \approx 92.4\%.

Final answer

η=92.4%\eta = 92.4\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the energy flow diagram of a real transformer to distinguish copper losses (I2rI^2 r) from iron/core losses (PcoreP_{\text{core}}).

  • Practice setting up power-balance equations where multiple distinct loss channels are specified in the problem statement.

OverviewACEpath Teacher's Diagnosis

03 The student inverts the turns ratio when calculating the secondary induced voltage, treating the transformer as step-up instead of step-down.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Es=Vp⋅(NpNs)=240⋅(60075)=1920 VE_s = V_p \cdot \left(\frac{N_p}{N_s}\right) = 240 \cdot \left(\frac{600}{75}\right) = 1920\text{ V}

    Correct

    εs=Vp(NsNp)=240 V(75600)=30.0 V\varepsilon_s = V_p \left(\frac{N_s}{N_p}\right) = 240\text{ V} \left(\frac{75}{600}\right) = 30.0\text{ V}

    The transformer equation relates coil voltage directly to turn count: εsVp=NsNp\frac{\varepsilon_s}{V_p} = \frac{N_s}{N_p}. Since the secondary coil has fewer turns (Ns=75<Np=600N_s = 75 < N_p = 600), this is a step-down transformer, so εs\varepsilon_s must be less than VpV_p.

  2. Step 2

    Is=EsRL+rs=19202.150=893.0 AI_s = \frac{E_s}{R_L + r_s} = \frac{1920}{2.150} = 893.0\text{ A}

    Correct

    Is=εsRL+rs=30.0 V2.00  Ω+0.150  Ω≈13.95 AI_s = \frac{\varepsilon_s}{R_L + r_s} = \frac{30.0\text{ V}}{2.00\;\Omega + 0.150\;\Omega} \approx 13.95\text{ A}

    You applied Ohm's law with total secondary loop resistance correctly, but your result was inflated by the incorrect induced EMF from Step 1.

  3. Step 3

    Pload=Is2⋅RL=(893.0)2⋅2.00=1594898 W  ⟹  Pcu=Is2⋅rs=(893.0)2⋅0.150=119617 WP_{\text{load}} = I_s^2 \cdot R_L = (893.0)^2 \cdot 2.00 = 1594898\text{ W} \implies P_{\text{cu}} = I_s^2 \cdot r_s = (893.0)^2 \cdot 0.150 = 119617\text{ W}

    Correct

    Pload=Is2RL≈(13.95 A)2(2.00  Ω)≈389.4 W  ⟹  Pcu=Is2rs≈(13.95 A)2(0.150  Ω)≈29.2 WP_{\text{load}} = I_s^2 R_L \approx (13.95\text{ A})^2 (2.00\;\Omega) \approx 389.4\text{ W} \implies P_{\text{cu}} = I_s^2 r_s \approx (13.95\text{ A})^2 (0.150\;\Omega) \approx 29.2\text{ W}

    You used the correct Joule heating formulas for the load power and winding copper loss, but the calculated values propagated the oversized current.

  4. Step 4

    Pinput=Pload+Pcu+Pcore=1594898+119617+18=1714533 W  ⟹  η=(15948981714533)⋅100%=93.0%P_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}} = 1594898 + 119617 + 18 = 1714533\text{ W} \implies \eta = \left(\frac{1594898}{1714533}\right) \cdot 100\% = 93.0\%

    Correct

    Pinput=Pload+Pcu+Pcore  ⟹  η=PloadPinput×100%=92.4%P_{\text{input}} = P_{\text{load}} + P_{\text{cu}} + P_{\text{core}} \implies \eta = \frac{P_{\text{load}}}{P_{\text{input}}} \times 100\% = 92.4\%

    Your energy conservation relation and efficiency definition were completely correct, but the final percentage was affected by the earlier numerical error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly summed the external load resistance and internal winding resistance in series.

You applied the correct power dissipation formulas for both the useful load and winding copper losses.

You accounted for core losses alongside copper losses to determine total input power.

You correctly set up the efficiency fraction as useful load power divided by total input power.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted turns ratio

You accidentally wrote the turns ratio as NpNs\frac{N_p}{N_s} instead of NsNp\frac{N_s}{N_p}, multiplying by 88 instead of dividing by 88.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the voltage turns ratio VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p} with the inverse current turns ratio IsIp=NpNs\frac{I_s}{I_p} = \frac{N_p}{N_s}, leading to treating a step-down transformer as a step-up transformer.

REASONING PATH
Your ACEpath teacher’s suggested approach
Voltage-to-Turns Sanity Check
  • Voltage is directly proportional to turns: VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p}.

  • Before computing, check whether Ns<NpN_s < N_p (step-down, Vs<VpV_s < V_p) or Ns>NpN_s > N_p (step-up, Vs>VpV_s > V_p).

Distinguish Voltage Ratio vs. Current Ratio
  • For an ideal magnetic coupling, VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p}, whereas IsIp≈NpNs\frac{I_s}{I_p} \approx \frac{N_p}{N_s}.

  • Ensure you place secondary turns in the numerator when solving for secondary voltage.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compute secondary induced EMF: εs=240 V×75600=30.0 V\varepsilon_s = 240\text{ V} \times \frac{75}{600} = 30.0\text{ V}.

  2. Find total secondary circuit current: Is=30.0 V2.00  Ω+0.150  Ω=30.0 V2.15  Ω≈13.9535 AI_s = \frac{30.0\text{ V}}{2.00\;\Omega + 0.150\;\Omega} = \frac{30.0\text{ V}}{2.15\;\Omega} \approx 13.9535\text{ A}.

  3. Calculate load power and losses: Pload=(13.9535 A)2×2.00  Ω≈389.40 WP_{\text{load}} = (13.9535\text{ A})^2 \times 2.00\;\Omega \approx 389.40\text{ W}, Pcu=(13.9535 A)2×0.150  Ω≈29.21 WP_{\text{cu}} = (13.9535\text{ A})^2 \times 0.150\;\Omega \approx 29.21\text{ W}.

  4. Sum total input power: Pinput=389.40 W+29.21 W+18.0 W≈436.61 WP_{\text{input}} = 389.40\text{ W} + 29.21\text{ W} + 18.0\text{ W} \approx 436.61\text{ W}.

Final answer

η=92.4%\eta = 92.4\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the direct proportionality VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p} and verify whether a transformer is step-up or step-down before calculating.

  • Practice checking realistic power scales: an ordinary small transformer should not output megawatts from a 240 V240\text{ V} input.

Lock it in

Similar question

01

An ideal core transformer with negligible primary resistance has an induced secondary EMF of εs=40.0 V\varepsilon_s = 40.0\text{ V}. The secondary winding has an internal resistance of rs=0.50  Ωr_s = 0.50\;\Omega and powers a load of RL=7.50  ΩR_L = 7.50\;\Omega. If core losses are 10.0 W10.0\text{ W}, find the operating efficiency η\eta.

Answer

η=90.4%\eta = 90.4\%. First find Rtotal=7.50+0.50=8.00  ΩR_{\text{total}} = 7.50 + 0.50 = 8.00\;\Omega, so Is=40.08.00=5.00 AI_s = \frac{40.0}{8.00} = 5.00\text{ A}. Then Pload=Is2RL=(5.00)2(7.50)=187.5 WP_{\text{load}} = I_s^2 R_L = (5.00)^2(7.50) = 187.5\text{ W} and total secondary dissipation Psec=Is2Rtotal=(5.00)2(8.00)=200.0 WP_{\text{sec}} = I_s^2 R_{\text{total}} = (5.00)^2(8.00) = 200.0\text{ W}. Input power is Pinput=200.0+10.0=210.0 WP_{\text{input}} = 200.0 + 10.0 = 210.0\text{ W}, yielding η=187.5210.0×100%≈90.4%\eta = \frac{187.5}{210.0} \times 100\% \approx 90.4\%.

02

A step-down transformer produces an induced secondary EMF of εs=12.0 V\varepsilon_s = 12.0\text{ V} and delivers power to a load resistor RL=3.60  ΩR_L = 3.60\;\Omega. The terminal voltage across the load is measured to be VL=10.8 VV_L = 10.8\text{ V}. Assuming core losses are 2.50 W2.50\text{ W}, determine the internal resistance rsr_s of the secondary winding and the transformer efficiency η\eta.

Answer

rs=0.40  Ωr_s = 0.40\;\Omega and η=84.4%\eta = 84.4\%. The current is Is=VLRL=10.83.60=3.00 AI_s = \frac{V_L}{R_L} = \frac{10.8}{3.60} = 3.00\text{ A}. The internal drop is εs−VL=12.0−10.8=1.20 V\varepsilon_s - V_L = 12.0 - 10.8 = 1.20\text{ V}, so rs=1.20 V3.00 A=0.40  Ωr_s = \frac{1.20\text{ V}}{3.00\text{ A}} = 0.40\;\Omega. Useful power is Pload=(3.00)(10.8)=32.4 WP_{\text{load}} = (3.00)(10.8) = 32.4\text{ W}. Total input power is Pinput=εsIs+Pcore=(12.0)(3.00)+2.50=38.5 WP_{\text{input}} = \varepsilon_s I_s + P_{\text{core}} = (12.0)(3.00) + 2.50 = 38.5\text{ W}. Efficiency is η=32.438.5×100%≈84.4%\eta = \frac{32.4}{38.5} \times 100\% \approx 84.4\%.

03

A power transformer with Np/Ns=5N_p/N_s = 5 operates from a 120 V (rms)120\text{ V (rms)} source. The secondary winding has resistance rs=0.20  Ωr_s = 0.20\;\Omega feeding a variable resistive load RLR_L. Core losses are fixed at 15.0 W15.0\text{ W}. If the load is adjusted so that it draws maximum power from the secondary coil, calculate the efficiency η\eta under this maximum-power condition.

Answer

η=48.4%\eta = 48.4\%. Induced EMF is εs=1205=24.0 V\varepsilon_s = \frac{120}{5} = 24.0\text{ V}. Maximum power transfer to the load occurs when RL=rs=0.20  ΩR_L = r_s = 0.20\;\Omega. Then total resistance is Rtotal=0.40  ΩR_{\text{total}} = 0.40\;\Omega, giving Is=24.00.40=60.0 AI_s = \frac{24.0}{0.40} = 60.0\text{ A}. Load power is Pload=Is2RL=(60.0)2(0.20)=720 WP_{\text{load}} = I_s^2 R_L = (60.0)^2(0.20) = 720\text{ W}. Secondary copper loss is Pcu=(60.0)2(0.20)=720 WP_{\text{cu}} = (60.0)^2(0.20) = 720\text{ W}. Total input power is Pinput=720+720+15.0=1455 WP_{\text{input}} = 720 + 720 + 15.0 = 1455\text{ W}. Efficiency is η=7201455×100%≈48.4%\eta = \frac{720}{1455} \times 100\% \approx 48.4\%.