Resources
In a university modern physics laboratory experiment modeled after the classic Frisch-Smith experiment, charged pions produced in a target enter an evacuated drift tube of rest length . Time-of-flight scintillation counters measure that the pions take to traverse the entire tube. The accepted proper half-life of a charged pion at rest is . (a) Determine the speed parameter and Lorentz factor of the pions in the lab frame (). (b) Calculate the proper time elapsed on the internal decay clock of a pion during the transit, and determine the ratio .
Answer and steps
Final answer
(a) , ; (b) , giving an elapsed ratio of
Steps
Part (a): Determining the Speed Parameter and Lorentz Factor
- Calculate the pion's speed in the laboratory frame: In the laboratory reference frame, the drift tube is at rest, so the distance traveled by the pions is equal to the tube's rest length, . With a measured time-of-flight of , the speed is:
- Compute the speed parameter : The ratio of the particle's speed to the speed of light is:
- Compute the Lorentz factor : Using the definition :
Part (b): Calculating the Proper Time and the Ratio
-
Relate laboratory time to proper time via time dilation: The internal clock of the pion measures the proper time interval because both the start and the end of the transit occur at the same spatial location in the pion's rest frame. According to time dilation:
Substituting and :
(Alternative verification via length contraction: In the pion's frame, the drift tube moves toward the pion and is contracted to . The transit time is then , confirming the result.)
- Find the elapsed ratio : Given the proper half-life :
Common Pitfall: A frequent mistake is setting . Remember that a moving clock always ticks slower relative to a stationary observer: the proper time between two co-local events is always the shortest measured time interval, so .
Typical errors
01 The student inverts the time dilation relation by multiplying the lab time by γ instead of dividing, concluding that the proper time is dilated relative to the lab frame.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You multiplied the laboratory time by instead of dividing by . Because proper time is measured in the pion's rest frame where the particle remains at the same spatial position, it is always smaller than the dilated laboratory time interval ().
- Step 4Correct
Your division step was carried out correctly, but the numerical result was affected by the inverted time value from Step 3.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the laboratory transit speed and converted it into the dimensionless speed parameter .
You evaluated the Lorentz factor using the correct relativistic formula.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou set instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing which frame measures proper time versus dilated time. Proper time is measured by a clock at rest relative to the events (the pion's own internal clock), making it the minimum time interval between those two events.
REASONING PATH
Your ACEpath teacher’s suggested approach- Identify Proper Time
Proper time is measured by a single clock present at both events.
Ask: Does a single clock at rest in this frame measure both the start and end of the event? For the moving particle, its internal clock is co-local with both events, so it measures .
- Sanity Check Time Dilation
Moving clocks run slow: , where , which implies .
Check that the elapsed proper time is strictly less than the time interval measured by stationary laboratory clocks.
CORRECTED PATH
ACEpath Teacher's DemonstrationApply the time dilation relation , giving .
Divide the proper time by the proper half-life: .
(a) , ; (b) , giving
02 The student omits the square root when calculating the Lorentz factor, computing γ = 1 / (1 - β²) instead of 1 / √(1 - β²).
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You omitted the square root in the definition of the Lorentz factor. The formula is , not .
- Step 3Correct
Your reasoning that the proper time interval is shorter than the laboratory interval () is completely sound, but substituting your earlier value led to an incorrect numerical result.
- Step 4Correct
You correctly identified how to compute the elapsed lifetime ratio, but the value is affected by the earlier error in .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used distance over time to find the lab speed and the speed parameter .
You correctly identified that the pion's internal clock measures proper time and divided by to account for time dilation.
You correctly set up the final comparison ratio .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou calculated instead of taking the square root in the denominator.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the relativistic factor as an inverse quadratic term rather than remembering that it stems from the Pythagorean spacetime interval relation , which yields a square root: .
REASONING PATH
Your ACEpath teacher’s suggested approach- Definition of Lorentz Factor
The Lorentz factor always contains a square root: .
Whenever you compute , take its square root before evaluating the reciprocal.
- Sanity Check for Common $\beta$ Values
A 3-4-5 right triangle analogy helps: for , . For , . For , .
Check whether your calculated matches the expected order of magnitude; corresponds to , not .
CORRECTED PATH
ACEpath Teacher's DemonstrationApply the full formula with the square root: .
Recalculate proper time: .
Compute the ratio: .
(a) , ; (b) ,
03 The student misidentifies the given lab time as the proper time and calculates the ratio using Δt_lab / τ₀ directly without applying time dilation.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
The time of was recorded by laboratory scintillation counters across two separate locations, so it is the dilated laboratory time interval , not the proper time . Because moving clocks tick slower, the proper time elapsed on the pion's internal clock must be shorter: .
- Step 4Correct
Your division was set up correctly, but the resulting numerical value was affected by using the uncorrected transit time from the previous step.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly related the laboratory rest length and transit time to find the particle velocity.
You correctly calculated the dimensionless speed parameter and Lorentz factor .
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou conflated the laboratory frame coordinate time with the proper time , missing the fact that proper time is measured only by a single clock that is present at both the start and finish events (the particle's rest frame).
REASONING PATH
Your ACEpath teacher’s suggested approach- Identify which frame measures proper time
Proper time is the time interval measured by a clock present at both events at the same spatial location (). Laboratory detectors placed at two different positions measure dilated time .
Always verify whether the measured time comes from a clock traveling with the object (proper time) or separate stationary clocks in the lab (dilated time).
- Check magnitude: moving clocks tick slower
Because for any non-zero speed, the proper time is always strictly shorter than the laboratory-measured time: .
When solving for proper time from lab time, divide by rather than setting them equal or multiplying.
CORRECTED PATH
ACEpath Teacher's DemonstrationApply the time dilation relation: .
Substitute the laboratory time and : .
Calculate the decay ratio with the proper half-life : .
(a) , ; (b) ,
Lock it in
What is the physical definition of proper time between two events?
is the time interval measured by a single clock present at both events (co-local events). Memory cue: proper time is always the shortest measured time interval between the events.
Similar question
A beam of neutral kaons travels down a beamline at speed (giving ). Laboratory detectors measure their flight time as . Calculate the proper time that elapsed on the kaons' internal clock.
Answer
. Key steps: Relate lab time to proper time via , so .
Atmospheric muons are created at an altitude of and reach sea level with speed parameter (). (a) What is the transit time in the Earth (lab) frame? (b) How much proper time elapses for the muons during this descent?
Answer
(a) ; (b) . Key steps: (a) , so . (b) .
A relativistic particle with a rest-frame mean lifetime passes through a drift chamber of rest length . It is observed in the lab to survive the transit for an elapsed lab time of . (a) Determine and . (b) Verify that the particle's elapsed proper time is consistent using both time dilation and length contraction.
Answer
(a) , ; (b) by both methods. Key steps: (a) ; . (b) Time dilation: . Length contraction: in the particle frame, the chamber length is , so transit time is .