Resources

In a university modern physics laboratory experiment modeled after the classic Frisch-Smith experiment, charged pions produced in a target enter an evacuated drift tube of rest length L0=15.0 mL_0 = 15.0\text{ m}. Time-of-flight scintillation counters measure that the pions take Δtlab=52.1 ns\Delta t_{\text{lab}} = 52.1\text{ ns} to traverse the entire tube. The accepted proper half-life of a charged pion at rest is τ0=18.0 ns\tau_0 = 18.0\text{ ns}. (a) Determine the speed parameter β=v/c\beta = v/c and Lorentz factor γ\gamma of the pions in the lab frame (c=3.00×108 m/sc = 3.00\times 10^8\text{ m/s}). (b) Calculate the proper time Δt0\Delta t_0 elapsed on the internal decay clock of a pion during the transit, and determine the ratio Δt0/τ0\Delta t_0 / \tau_0.

Answer and steps

Final answer

(a) β=0.960\beta = 0.960, γ=3.57\gamma = 3.57; (b) Δt0=14.6 ns\Delta t_0 = 14.6\text{ ns}, giving an elapsed ratio of Δt0/τ0=0.811\Delta t_0 / \tau_0 = 0.811

Steps

Part (a): Determining the Speed Parameter β\beta and Lorentz Factor γ\gamma

  1. Calculate the pion's speed in the laboratory frame: In the laboratory reference frame, the drift tube is at rest, so the distance traveled by the pions is equal to the tube's rest length, L0=15.0 mL_0 = 15.0\text{ m}. With a measured time-of-flight of Δtlab=52.1 ns=52.1×10−9 s\Delta t_{\text{lab}} = 52.1\text{ ns} = 52.1\times 10^{-9}\text{ s}, the speed vv is: v=L0Δtlab=15.0 m52.1×10−9 s≈2.879×108 m/sv = \frac{L_0}{\Delta t_{\text{lab}}} = \frac{15.0\text{ m}}{52.1\times 10^{-9}\text{ s}} \approx 2.879\times 10^8\text{ m/s}
  2. Compute the speed parameter β\beta: The ratio of the particle's speed to the speed of light c=3.00×108 m/sc = 3.00\times 10^8\text{ m/s} is: β=vc=2.879×108 m/s3.00×108 m/s≈0.960\beta = \frac{v}{c} = \frac{2.879\times 10^8\text{ m/s}}{3.00\times 10^8\text{ m/s}} \approx 0.960
  3. Compute the Lorentz factor γ\gamma: Using the definition γ=11−β2\gamma = \frac{1}{\sqrt{1 - \beta^2}}: γ=11−(0.960)2=11−0.9216=10.0784=10.280≈3.57\gamma = \frac{1}{\sqrt{1 - (0.960)^2}} = \frac{1}{\sqrt{1 - 0.9216}} = \frac{1}{\sqrt{0.0784}} = \frac{1}{0.280} \approx 3.57

Part (b): Calculating the Proper Time Δt0\Delta t_0 and the Ratio Δt0/τ0\Delta t_0 / \tau_0

  1. Relate laboratory time to proper time via time dilation: The internal clock of the pion measures the proper time interval Δt0\Delta t_0 because both the start and the end of the transit occur at the same spatial location in the pion's rest frame. According to time dilation: Δtlab=γΔt0  ⟹  Δt0=Δtlabγ\Delta t_{\text{lab}} = \gamma \Delta t_0 \implies \Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma}

    Substituting Δtlab=52.1 ns\Delta t_{\text{lab}} = 52.1\text{ ns} and γ≈3.571\gamma \approx 3.571: Δt0=52.1 ns3.571≈14.6 ns\Delta t_0 = \frac{52.1\text{ ns}}{3.571} \approx 14.6\text{ ns}

    (Alternative verification via length contraction: In the pion's frame, the drift tube moves toward the pion and is contracted to L=L0/γ=15.0 m/3.571≈4.20 mL = L_0 / \gamma = 15.0\text{ m} / 3.571 \approx 4.20\text{ m}. The transit time is then Δt0=L/v=4.20 m/(2.879×108 m/s)≈14.6 ns\Delta t_0 = L / v = 4.20\text{ m} / (2.879\times 10^8\text{ m/s}) \approx 14.6\text{ ns}, confirming the result.)

  2. Find the elapsed ratio Δt0/τ0\Delta t_0 / \tau_0: Given the proper half-life τ0=18.0 ns\tau_0 = 18.0\text{ ns}: Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811

Common Pitfall: A frequent mistake is setting Δt0=γΔtlab\Delta t_0 = \gamma \Delta t_{\text{lab}}. Remember that a moving clock always ticks slower relative to a stationary observer: the proper time Δt0\Delta t_0 between two co-local events is always the shortest measured time interval, so Δt0<Δtlab\Delta t_0 < \Delta t_{\text{lab}}.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student inverts the time dilation relation by multiplying the lab time by γ instead of dividing, concluding that the proper time is dilated relative to the lab frame.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    v=15.052.1×10−9=2.88×108 m/s  ⟹  β=2.88×1083.00×108=0.960v = \frac{15.0}{52.1 \times 10^{-9}} = 2.88 \times 10^8\text{ m/s} \implies \beta = \frac{2.88 \times 10^8}{3.00 \times 10^8} = 0.960

  2. Step 2

    γ=11−0.9602=3.57\gamma = \frac{1}{\sqrt{1 - 0.960^2}} = 3.57

  3. Step 3

    Δt0=γ×ΔtLab=3.57×52.1 ns=186 ns\Delta t_0 = \gamma \times \Delta t_{\text{Lab}} = 3.57 \times 52.1\text{ ns} = 186\text{ ns}

    Correct

    Δtlab=γΔt0  ⟹  Δt0=Δtlabγ=52.1 ns3.57≈14.6 ns\Delta t_{\text{lab}} = \gamma \Delta t_0 \implies \Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{3.57} \approx 14.6\text{ ns}

    You multiplied the laboratory time by γ\gamma instead of dividing by γ\gamma. Because proper time Δt0\Delta t_0 is measured in the pion's rest frame where the particle remains at the same spatial position, it is always smaller than the dilated laboratory time interval ( Δtlab=γΔt0 \,\Delta t_{\text{lab}} = \gamma \Delta t_0\,).

  4. Step 4

    Δt0τ0=186 ns18.0 ns=10.3\frac{\Delta t_0}{\tau_0} = \frac{186\text{ ns}}{18.0\text{ ns}} = 10.3

    Correct

    Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811

    Your division step was carried out correctly, but the numerical result was affected by the inverted time value from Step 3.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the laboratory transit speed and converted it into the dimensionless speed parameter β\beta.

You evaluated the Lorentz factor γ\gamma using the correct relativistic formula.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Time Dilation Relation

You set Δt0=γΔtlab\Delta t_0 = \gamma \Delta t_{\text{lab}} instead of Δtlab=γΔt0\Delta t_{\text{lab}} = \gamma \Delta t_0.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing which frame measures proper time versus dilated time. Proper time Δt0\Delta t_0 is measured by a clock at rest relative to the events (the pion's own internal clock), making it the minimum time interval between those two events.

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify Proper Time
  • Proper time Δt0\Delta t_0 is measured by a single clock present at both events.

  • Ask: Does a single clock at rest in this frame measure both the start and end of the event? For the moving particle, its internal clock is co-local with both events, so it measures Δt0\Delta t_0.

Sanity Check Time Dilation
  • Moving clocks run slow: Δt=γΔt0\Delta t = \gamma \Delta t_0, where γ≥1\gamma \ge 1, which implies Δt0≤Δt\Delta t_0 \le \Delta t.

  • Check that the elapsed proper time Δt0\Delta t_0 is strictly less than the time interval Δtlab\Delta t_{\text{lab}} measured by stationary laboratory clocks.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the time dilation relation Δtlab=γΔt0\Delta t_{\text{lab}} = \gamma \Delta t_0, giving Δt0=Δtlabγ=52.1 ns3.571≈14.59 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{3.571} \approx 14.59\text{ ns}.

  2. Divide the proper time by the proper half-life: Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811.

Final answer

(a) β=0.960\beta = 0.960, γ=3.57\gamma = 3.57; (b) Δt0=14.6 ns\Delta t_0 = 14.6\text{ ns}, giving Δt0τ0=0.811\frac{\Delta t_0}{\tau_0} = 0.811

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the definition of proper time Δt0\Delta t_0 as the time interval measured in the reference frame where the two events occur at the same location.

  • Always perform a magnitude check: because γ>1\gamma > 1, the dilated time in any other frame must be longer than the proper time ( Δtother>Δt0 \,\Delta t_{\text{other}} > \Delta t_0\,).

OverviewACEpath Teacher's Diagnosis

02 The student omits the square root when calculating the Lorentz factor, computing γ = 1 / (1 - β²) instead of 1 / √(1 - β²).

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    v=15.052.1×10−9=2.88×108 m/s  ⟹  β=2.88×1083.00×108=0.960v = \frac{15.0}{52.1\times 10^{-9}} = 2.88\times 10^8\text{ m/s} \implies \beta = \frac{2.88\times 10^8}{3.00\times 10^8} = 0.960

  2. Step 2

    γ=11−0.9602=10.0784=12.8\gamma = \frac{1}{1 - 0.960^2} = \frac{1}{0.0784} = 12.8

    Correct

    γ=11−β2=11−0.9602=10.0784=10.280≈3.57\gamma = \frac{1}{\sqrt{1 - \beta^2}} = \frac{1}{\sqrt{1 - 0.960^2}} = \frac{1}{\sqrt{0.0784}} = \frac{1}{0.280} \approx 3.57

    You omitted the square root in the definition of the Lorentz factor. The formula is γ=11−β2\gamma = \frac{1}{\sqrt{1 - \beta^2}}, not 11−β2\frac{1}{1 - \beta^2}.

  3. Step 3

    Δt0=Δtlabγ=52.1 ns12.8=4.07 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{12.8} = 4.07\text{ ns}

    Correct

    Δt0=Δtlabγ=52.1 ns3.57≈14.6 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{3.57} \approx 14.6\text{ ns}

    Your reasoning that the proper time interval is shorter than the laboratory interval (Δt0=Δtlab/γ\Delta t_0 = \Delta t_{\text{lab}} / \gamma) is completely sound, but substituting your earlier value γ=12.8\gamma = 12.8 led to an incorrect numerical result.

  4. Step 4

    Δt0τ0=4.07 ns18.0 ns=0.226\frac{\Delta t_0}{\tau_0} = \frac{4.07\text{ ns}}{18.0\text{ ns}} = 0.226

    Correct

    Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811

    You correctly identified how to compute the elapsed lifetime ratio, but the value is affected by the earlier error in γ\gamma.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used distance over time to find the lab speed vv and the speed parameter β\beta.

You correctly identified that the pion's internal clock measures proper time Δt0\Delta t_0 and divided by γ\gamma to account for time dilation.

You correctly set up the final comparison ratio Δt0/τ0\Delta t_0 / \tau_0.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing Radical in Lorentz Factor

You calculated γ=11−β2\gamma = \frac{1}{1-\beta^2} instead of taking the square root in the denominator.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the relativistic factor as an inverse quadratic term rather than remembering that it stems from the Pythagorean spacetime interval relation c2Δt2=c2Δt02+v2Δt2c^2 \Delta t^2 = c^2 \Delta t_0^2 + v^2 \Delta t^2, which yields a square root: γ=(1−β2)−1/2\gamma = (1 - \beta^2)^{-1/2}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Definition of Lorentz Factor
  • The Lorentz factor always contains a square root: γ=11−β2\gamma = \frac{1}{\sqrt{1-\beta^2}}.

  • Whenever you compute 1−β21 - \beta^2, take its square root before evaluating the reciprocal.

Sanity Check for Common $\beta$ Values
  • A 3-4-5 right triangle analogy helps: for β=0.6\beta = 0.6, 1−β2=0.8  ⟹  γ=1.25\sqrt{1-\beta^2} = 0.8 \implies \gamma = 1.25. For β=0.8\beta = 0.8, 1−β2=0.6  ⟹  γ=1.67\sqrt{1-\beta^2} = 0.6 \implies \gamma = 1.67. For β=0.96\beta = 0.96, 1−0.962=0.0784=0.28  ⟹  γ=3.57\sqrt{1-0.96^2} = \sqrt{0.0784} = 0.28 \implies \gamma = 3.57.

  • Check whether your calculated γ\gamma matches the expected order of magnitude; γ≈13\gamma \approx 13 corresponds to β>0.997\beta > 0.997, not β=0.960\beta = 0.960.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the full formula with the square root: γ=11−(0.960)2=10.0784=10.280≈3.571\gamma = \frac{1}{\sqrt{1 - (0.960)^2}} = \frac{1}{\sqrt{0.0784}} = \frac{1}{0.280} \approx 3.571.

  2. Recalculate proper time: Δt0=Δtlabγ=52.1 ns3.571≈14.59 ns≈14.6 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{3.571} \approx 14.59\text{ ns} \approx 14.6\text{ ns}.

  3. Compute the ratio: Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811.

Final answer

(a) β=0.960\beta = 0.960, γ=3.57\gamma = 3.57; (b) Δt0=14.6 ns\Delta t_0 = 14.6\text{ ns}, Δt0/τ0=0.811\Delta t_0 / \tau_0 = 0.811

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the Lorentz factor formula as γ=(1−β2)−1/2\gamma = (1 - \beta^2)^{-1/2} so you never forget the radical.

  • Practice computing γ\gamma for benchmark values like β=0.6\beta = 0.6, 0.80.8, and 0.960.96 using Pythagorean triples.

  • Always review intermediate values against physical intuition before carrying them into time dilation calculations.

OverviewACEpath Teacher's Diagnosis

03 The student misidentifies the given lab time as the proper time and calculates the ratio using Δt_lab / τ₀ directly without applying time dilation.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    v=15.052.1×10−9=2.88×108 m/s  ⟹  β=2.88×1083.00×108=0.960v = \frac{15.0}{52.1 \times 10^{-9}} = 2.88 \times 10^8\text{ m/s} \implies \beta = \frac{2.88 \times 10^8}{3.00 \times 10^8} = 0.960

  2. Step 2

    γ=11−0.9602=3.57\gamma = \frac{1}{\sqrt{1 - 0.960^2}} = 3.57

  3. Step 3

    Δt0=52.1 ns\Delta t_0 = 52.1\text{ ns}

    Correct

    Δt0=Δtlabγ=52.1 ns3.57≈14.6 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{52.1\text{ ns}}{3.57} \approx 14.6\text{ ns}

    The time of 52.1 ns52.1\text{ ns} was recorded by laboratory scintillation counters across two separate locations, so it is the dilated laboratory time interval Δtlab\Delta t_{\text{lab}}, not the proper time Δt0\Delta t_0. Because moving clocks tick slower, the proper time elapsed on the pion's internal clock must be shorter: Δt0=Δtlab/γ\Delta t_0 = \Delta t_{\text{lab}} / \gamma.

  4. Step 4

    Δt0τ0=52.1 ns18.0 ns=2.89\frac{\Delta t_0}{\tau_0} = \frac{52.1\text{ ns}}{18.0\text{ ns}} = 2.89

    Correct

    Δt0τ0=14.6 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.6\text{ ns}}{18.0\text{ ns}} \approx 0.811

    Your division was set up correctly, but the resulting numerical value was affected by using the uncorrected transit time from the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly related the laboratory rest length and transit time to find the particle velocity.

You correctly calculated the dimensionless speed parameter β\beta and Lorentz factor γ\gamma.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Proper Time Misidentification

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You conflated the laboratory frame coordinate time Δtlab\Delta t_{\text{lab}} with the proper time Δt0\Delta t_0, missing the fact that proper time is measured only by a single clock that is present at both the start and finish events (the particle's rest frame).

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify which frame measures proper time
  • Proper time Δt0\Delta t_0 is the time interval measured by a clock present at both events at the same spatial location (x1′=x2′x_1' = x_2'). Laboratory detectors placed at two different positions measure dilated time Δt=γΔt0\Delta t = \gamma \Delta t_0.

  • Always verify whether the measured time comes from a clock traveling with the object (proper time) or separate stationary clocks in the lab (dilated time).

Check magnitude: moving clocks tick slower
  • Because γ>1\gamma > 1 for any non-zero speed, the proper time is always strictly shorter than the laboratory-measured time: Δt0<Δtlab\Delta t_0 < \Delta t_{\text{lab}}.

  • When solving for proper time from lab time, divide by γ\gamma rather than setting them equal or multiplying.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the time dilation relation: Δtlab=γΔt0  ⟹  Δt0=Δtlabγ\Delta t_{\text{lab}} = \gamma \Delta t_0 \implies \Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma}.

  2. Substitute the laboratory time Δtlab=52.1 ns\Delta t_{\text{lab}} = 52.1\text{ ns} and γ≈3.571\gamma \approx 3.571: Δt0=52.1 ns3.571≈14.59 ns\Delta t_0 = \frac{52.1\text{ ns}}{3.571} \approx 14.59\text{ ns}.

  3. Calculate the decay ratio with the proper half-life τ0=18.0 ns\tau_0 = 18.0\text{ ns}: Δt0τ0=14.59 ns18.0 ns≈0.811\frac{\Delta t_0}{\tau_0} = \frac{14.59\text{ ns}}{18.0\text{ ns}} \approx 0.811.

Final answer

(a) β=0.960\beta = 0.960, γ=3.57\gamma = 3.57; (b) Δt0=14.6 ns\Delta t_0 = 14.6\text{ ns}, Δt0/τ0=0.811\Delta t_0 / \tau_0 = 0.811

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice distinguishing between proper time (single moving clock) and dilated coordinate time (synchronized laboratory clocks).

  • Perform a quick sanity check on relativistic decay problems: elapsed proper time Δt0\Delta t_0 must always be smaller than the laboratory transit time Δtlab\Delta t_{\text{lab}}.

Lock it in

Similar question

01

A beam of neutral kaons travels down a beamline at speed β=0.800\beta = 0.800 (giving γ=1.67\gamma = 1.67). Laboratory detectors measure their flight time as Δtlab=25.0 ns\Delta t_{\text{lab}} = 25.0\text{ ns}. Calculate the proper time Δt0\Delta t_0 that elapsed on the kaons' internal clock.

Answer

Δt0=15.0 ns\Delta t_0 = 15.0\text{ ns}. Key steps: Relate lab time to proper time via Δtlab=γΔt0\Delta t_{\text{lab}} = \gamma \Delta t_0, so Δt0=Δtlabγ=25.0 ns1.67≈15.0 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{25.0\text{ ns}}{1.67} \approx 15.0\text{ ns}.

02

Atmospheric muons are created at an altitude of 10.0 km10.0\text{ km} and reach sea level with speed parameter β=0.995\beta = 0.995 ( γ≈10.0 \,\gamma \approx 10.0\,). (a) What is the transit time in the Earth (lab) frame? (b) How much proper time Δt0\Delta t_0 elapses for the muons during this descent?

Answer

(a) ΔtEarth≈33.5 μs\Delta t_{\text{Earth}} \approx 33.5\text{ }\mu\text{s}; (b) Δt0≈3.35 μs\Delta t_0 \approx 3.35\text{ }\mu\text{s}. Key steps: (a) v=0.995×3.00×108 m/s=2.985×108 m/sv = 0.995 \times 3.00 \times 10^8\text{ m/s} = 2.985 \times 10^8\text{ m/s}, so ΔtEarth=10000 m2.985×108 m/s≈33.5 μs\Delta t_{\text{Earth}} = \frac{10000\text{ m}}{2.985 \times 10^8\text{ m/s}} \approx 33.5\text{ }\mu\text{s}. (b) Δt0=ΔtEarthγ=33.5 μs10.0=3.35 μs\Delta t_0 = \frac{\Delta t_{\text{Earth}}}{\gamma} = \frac{33.5\text{ }\mu\text{s}}{10.0} = 3.35\text{ }\mu\text{s}.

03

A relativistic particle with a rest-frame mean lifetime τ0=26.0 ns\tau_0 = 26.0\text{ ns} passes through a drift chamber of rest length L0=18.0 mL_0 = 18.0\text{ m}. It is observed in the lab to survive the transit for an elapsed lab time of Δtlab=65.0 ns\Delta t_{\text{lab}} = 65.0\text{ ns}. (a) Determine β\beta and γ\gamma. (b) Verify that the particle's elapsed proper time Δt0\Delta t_0 is consistent using both time dilation and length contraction.

Answer

(a) β=0.923\beta = 0.923, γ=2.60\gamma = 2.60; (b) Δt0=25.0 ns\Delta t_0 = 25.0\text{ ns} by both methods. Key steps: (a) v=18.0 m65.0×10−9 s=2.769×108 m/s  ⟹  β=2.7693.00≈0.923v = \frac{18.0\text{ m}}{65.0 \times 10^{-9}\text{ s}} = 2.769 \times 10^8\text{ m/s} \implies \beta = \frac{2.769}{3.00} \approx 0.923; γ=11−0.9232≈2.60\gamma = \frac{1}{\sqrt{1 - 0.923^2}} \approx 2.60. (b) Time dilation: Δt0=Δtlabγ=65.0 ns2.60=25.0 ns\Delta t_0 = \frac{\Delta t_{\text{lab}}}{\gamma} = \frac{65.0\text{ ns}}{2.60} = 25.0\text{ ns}. Length contraction: in the particle frame, the chamber length is L=L0γ=18.0 m2.60≈6.923 mL = \frac{L_0}{\gamma} = \frac{18.0\text{ m}}{2.60} \approx 6.923\text{ m}, so transit time is Lv=6.923 m2.769×108 m/s≈25.0 ns\frac{L}{v} = \frac{6.923\text{ m}}{2.769 \times 10^8\text{ m/s}} \approx 25.0\text{ ns}.

Loading workspace…