Resources

In a collegiate modern physics laboratory experiment, a student uses a vacuum photodiode with a potassium cathode to determine Planck's constant. Using five calibrated spectral calibration lines from a mercury discharge lamp and narrow bandpass filters, the student measures the stopping potential V0V_0 corresponding to each frequency ff: \begin{itemize} \item Line 1: f1=5.490×1014 Hzf_1 = 5.490 \times 10^{14}\text{ Hz}, V0,1=0.082 VV_{0,1} = 0.082\text{ V} \item Line 2: f2=6.879×1014 Hzf_2 = 6.879 \times 10^{14}\text{ Hz}, V0,2=0.656 VV_{0,2} = 0.656\text{ V} \item Line 3: f3=7.408×1014 Hzf_3 = 7.408 \times 10^{14}\text{ Hz}, V0,3=0.875 VV_{0,3} = 0.875\text{ V} \item Line 4: f4=8.214×1014 Hzf_4 = 8.214 \times 10^{14}\text{ Hz}, V0,4=1.209 VV_{0,4} = 1.209\text{ V} \item Line 5: f5=9.607×1014 Hzf_5 = 9.607 \times 10^{14}\text{ Hz}, V0,5=1.785 VV_{0,5} = 1.785\text{ V} \end{itemize} (a) By fitting the data to Einstein's photoelectric equation V0=(he)f−ΦeV_0 = \left(\frac{h}{e}\right) f - \frac{\Phi}{e}, determine the experimental slope he\frac{h}{e} in units of V⋅s\text{V}\cdot\text{s} using linear regression. (b) Given e=1.602×10−19 Ce = 1.602 \times 10^{-19}\text{ C}, compute the experimental value of Planck's constant hh and its percentage error relative to the accepted value (6.626×10−34 J⋅s6.626 \times 10^{-34}\text{ J}\cdot\text{s}). (c) Determine the experimental work function Φ\Phi of the potassium cathode in eV\text{eV} from the vertical intercept.

Answer and steps

Final answer

(a) Slope=4.14×10−15 V⋅s\text{Slope} = 4.14 \times 10^{-15}\text{ V}\cdot\text{s}; (b) h=6.63×10−34 J⋅sh = 6.63 \times 10^{-34}\text{ J}\cdot\text{s}, with a percentage error of +0.06%+0.06\%; (c) Φ=2.19 eV\Phi = 2.19\text{ eV}

Steps

Theoretical Background

Einstein's photoelectric equation relates the maximum kinetic energy of emitted photoelectrons, Kmax⁡K_{\max}, to the incident photon energy hfh f and the metal's work function Φ\Phi:

Kmax⁡=hf−ΦK_{\max} = h f - \Phi

Because the stopping potential V0V_0 brings the fastest photoelectrons to rest, Kmax⁡=eV0K_{\max} = e V_0, where ee is the elementary charge. Dividing by ee gives a linear relationship between V0V_0 and frequency ff:

V0=(he)f−ΦeV_0 = \left(\frac{h}{e}\right) f - \frac{\Phi}{e}

This equation takes the standard linear form y=mx+cy = m x + c, where:

  • The independent variable is x=fx = f.
  • The dependent variable is y=V0y = V_0.
  • The slope is m=hem = \frac{h}{e}.
  • The vertical intercept is c=−Φec = -\frac{\Phi}{e}.

Part (a): Linear Regression to Find the Experimental Slope he\frac{h}{e}

Let xi=fi/1014 Hzx_i = f_i / 10^{14}\text{ Hz} and yi=V0,i (in V)y_i = V_{0,i}\text{ (in V)} for the N=5N = 5 data pairs:

  1. (x1,y1)=(5.490,0.082)(x_1, y_1) = (5.490, 0.082)
  2. (x2,y2)=(6.879,0.656)(x_2, y_2) = (6.879, 0.656)
  3. (x3,y3)=(7.408,0.875)(x_3, y_3) = (7.408, 0.875)
  4. (x4,y4)=(8.214,1.209)(x_4, y_4) = (8.214, 1.209)
  5. (x5,y5)=(9.607,1.785)(x_5, y_5) = (9.607, 1.785)

Calculate the required sums:

∑xi=5.490+6.879+7.408+8.214+9.607=37.598\sum x_i = 5.490 + 6.879 + 7.408 + 8.214 + 9.607 = 37.598

xˉ=37.5985=7.5196\bar{x} = \frac{37.598}{5} = 7.5196

∑yi=0.082+0.656+0.875+1.209+1.785=4.607\sum y_i = 0.082 + 0.656 + 0.875 + 1.209 + 1.785 = 4.607

yˉ=4.6075=0.9214\bar{y} = \frac{4.607}{5} = 0.9214

∑xi2=5.4902+6.8792+7.4082+8.2142+9.6072≈292.103\sum x_i^2 = 5.490^2 + 6.879^2 + 7.408^2 + 8.214^2 + 9.607^2 \approx 292.103

∑xiyi=(5.490)(0.082)+(6.879)(0.656)+(7.408)(0.875)+(8.214)(1.209)+(9.607)(1.785)≈38.524\sum x_i y_i = (5.490)(0.082) + (6.879)(0.656) + (7.408)(0.875) + (8.214)(1.209) + (9.607)(1.785) \approx 38.524

The least-squares slope mm is given by:

m=∑xiyi−Nxˉyˉ∑xi2−Nxˉ2=38.524−5⋅(7.5196)⋅(0.9214)292.103−5⋅(7.5196)2=38.524−34.643292.103−282.722=3.8819.381≈0.4137 V/(1014 Hz)m = \frac{\sum x_i y_i - N \bar{x} \bar{y}}{\sum x_i^2 - N \bar{x}^2} = \frac{38.524 - 5 \cdot (7.5196) \cdot (0.9214)}{292.103 - 5 \cdot (7.5196)^2} = \frac{38.524 - 34.643}{292.103 - 282.722} = \frac{3.881}{9.381} \approx 0.4137\text{ V}/(10^{14}\text{ Hz})

Re-introducing the scale factor of 101410^{14}:

Slope=he=4.14×10−15 V⋅s\text{Slope} = \frac{h}{e} = 4.14 \times 10^{-15}\text{ V}\cdot\text{s}


Part (b): Calculation of Planck's Constant hh and Percentage Error

Using the slope and the given elementary charge e=1.602×10−19 Ce = 1.602 \times 10^{-19}\text{ C}:

h=(he)⋅e=(4.137×10−15 V⋅s)⋅(1.602×10−19 C)≈6.63×10−34 J⋅sh = \left(\frac{h}{e}\right) \cdot e = (4.137 \times 10^{-15}\text{ V}\cdot\text{s}) \cdot (1.602 \times 10^{-19}\text{ C}) \approx 6.63 \times 10^{-34}\text{ J}\cdot\text{s}

Comparing this with the accepted value hacc=6.626×10−34 J⋅sh_{\text{acc}} = 6.626 \times 10^{-34}\text{ J}\cdot\text{s}:

Percentage Error=h−hacchacc×100%=6.63×10−34−6.626×10−346.626×10−34×100%≈+0.06%\text{Percentage Error} = \frac{h - h_{\text{acc}}}{h_{\text{acc}}} \times 100\% = \frac{6.63 \times 10^{-34} - 6.626 \times 10^{-34}}{6.626 \times 10^{-34}} \times 100\% \approx +0.06\%


Part (c): Determination of the Work Function Φ\Phi

The vertical intercept cc of the linear fit is:

c=yˉ−mxˉ=0.9214−(0.4137)(7.5196)=0.9214−3.1109=−2.1895 V≈−2.19 Vc = \bar{y} - m \bar{x} = 0.9214 - (0.4137)(7.5196) = 0.9214 - 3.1109 = -2.1895\text{ V} \approx -2.19\text{ V}

From the photoelectric relation, the intercept is related to the cathode work function by c=−Φec = -\frac{\Phi}{e}. Therefore:

Φe=2.19 V  ⟹  Φ=2.19 eV\frac{\Phi}{e} = 2.19\text{ V} \implies \Phi = 2.19\text{ eV}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student estimates the slope by calculating a two-point rise over run between the extreme data points rather than using linear regression.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    m=V0,5−V0,1f5−f1=1.785−0.0829.607×1014−5.490×1014=4.136×10−15 V⋅s  ⟹  he=4.136×10−15 V⋅sm = \frac{V_{0,5} - V_{0,1}}{f_5 - f_1} = \frac{1.785 - 0.082}{9.607 \times 10^{14} - 5.490 \times 10^{14}} = 4.136 \times 10^{-15}\text{ V}\cdot\text{s} \implies \frac{h}{e} = 4.136 \times 10^{-15}\text{ V}\cdot\text{s}

    Correct

    m=∑fiV0,i−NfˉVˉ0∑fi2−Nfˉ2=4.14×10−15 V⋅sm = \frac{\sum f_i V_{0,i} - N\bar{f}\bar{V}_0}{\sum f_i^2 - N\bar{f}^2} = 4.14 \times 10^{-15}\text{ V}\cdot\text{s}

    The problem specifically asks for the slope obtained from linear regression. Using only the first and last data points discards the intermediate experimental data points and fails to minimize residual variance across the full dataset.

  2. Step 2

    h=(he)e=(4.136×10−15)(1.602×10−19)=6.626×10−34 J⋅s  ⟹  Percentage error=0.00%h = \left(\frac{h}{e}\right) e = (4.136 \times 10^{-15})(1.602 \times 10^{-19}) = 6.626 \times 10^{-34}\text{ J}\cdot\text{s} \implies \text{Percentage error} = 0.00\%

    Correct

    h=(4.137×10−15 V⋅s)(1.602×10−19 C)=6.63×10−34 J⋅s  ⟹  Percentage error=+0.06%h = (4.137 \times 10^{-15}\text{ V}\cdot\text{s})(1.602 \times 10^{-19}\text{ C}) = 6.63 \times 10^{-34}\text{ J}\cdot\text{s} \implies \text{Percentage error} = +0.06\%

    Your method of multiplying the slope by ee to find hh and computing percentage error was mathematically sound, but your result was affected by the two-point slope used in part (a).

  3. Step 3

    c=V0,1−mf1=0.082−(4.136×10−15)(5.490×1014)=−2.189 V  ⟹  Φ=2.189 eVc = V_{0,1} - m f_1 = 0.082 - (4.136 \times 10^{-15})(5.490 \times 10^{14}) = -2.189\text{ V} \implies \Phi = 2.189\text{ eV}

    Correct

    c=Vˉ0−mfˉ=0.9214−(0.4137)(7.5196)=−2.19 V  ⟹  Φ=2.19 eVc = \bar{V}_0 - m\bar{f} = 0.9214 - (0.4137)(7.5196) = -2.19\text{ V} \implies \Phi = 2.19\text{ eV}

    You correctly recognized that the vertical intercept gives −Φ/e-\Phi/e. However, you calculated the intercept using only the single data point (f1,V0,1)(f_1, V_{0,1}) rather than the centroid (fˉ,Vˉ0)(\bar{f}, \bar{V}_0) from linear regression.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly expressed Einstein's photoelectric equation in the linear form V0=(he)f−ΦeV_0 = \left(\frac{h}{e}\right) f - \frac{\Phi}{e}.

You correctly identified that multiplying the slope by the elementary charge ee yields Planck's constant hh.

You correctly linked the vertical intercept to the work function in electron-volts.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Two-point estimation instead of linear regression

No, this was a conceptual and methodological choice rather than an arithmetic slip.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You chose to estimate the slope using a two-point secant line (Δy/Δx)(\Delta y / \Delta x) connecting the two extreme data points instead of computing the least-squares best-fit parameters across all five measurements.

REASONING PATH
Your ACEpath teacher’s suggested approach
Linear Regression Requirement
  • When an experimental prompt specifies linear regression, all data pairs must be included using ∑xi\sum x_i, ∑yi\sum y_i, ∑xi2\sum x_i^2, and ∑xiyi\sum x_i y_i.

  • Compute summary statistics (xˉ,yˉ)(\bar{x}, \bar{y}) and use m=∑xiyi−Nxˉyˉ∑xi2−Nxˉ2m = \frac{\sum x_i y_i - N\bar{x}\bar{y}}{\sum x_i^2 - N\bar{x}^2} rather than selecting individual points.

Best-Fit Intercept
  • In a least-squares linear fit, the line passes through the centroid (xˉ,yˉ)(\bar{x}, \bar{y}), making the intercept c=yˉ−mxˉc = \bar{y} - m\bar{x}.

  • Substitute the mean values (xˉ,yˉ)(\bar{x}, \bar{y}) into c=yˉ−mxˉc = \bar{y} - m\bar{x} instead of plugging in an arbitrary single data point.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the sample means: fˉ=7.5196×1014 Hz\bar{f} = 7.5196 \times 10^{14}\text{ Hz} and Vˉ0=0.9214 V\bar{V}_0 = 0.9214\text{ V}.

  2. Compute the regression slope: m=∑fiV0,i−5fˉVˉ0∑fi2−5fˉ2=4.137×10−15 V⋅s≈4.14×10−15 V⋅sm = \frac{\sum f_i V_{0,i} - 5\bar{f}\bar{V}_0}{\sum f_i^2 - 5\bar{f}^2} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s} \approx 4.14 \times 10^{-15}\text{ V}\cdot\text{s}.

  3. Find h=m⋅e=(4.137×10−15 V⋅s)(1.602×10−19 C)=6.627×10−34 J⋅s≈6.63×10−34 J⋅sh = m \cdot e = (4.137 \times 10^{-15}\text{ V}\cdot\text{s})(1.602 \times 10^{-19}\text{ C}) = 6.627 \times 10^{-34}\text{ J}\cdot\text{s} \approx 6.63 \times 10^{-34}\text{ J}\cdot\text{s}.

  4. Compute percentage error: 6.627×10−34−6.626×10−346.626×10−34×100%≈+0.06%\frac{6.627 \times 10^{-34} - 6.626 \times 10^{-34}}{6.626 \times 10^{-34}} \times 100\% \approx +0.06\%.

  5. Determine the intercept from the centroid: c=Vˉ0−mfˉ=0.9214−(4.137×10−15)(7.5196×1014)=−2.1895 V≈−2.19 Vc = \bar{V}_0 - m\bar{f} = 0.9214 - (4.137 \times 10^{-15})(7.5196 \times 10^{14}) = -2.1895\text{ V} \approx -2.19\text{ V}, giving Φ=2.19 eV\Phi = 2.19\text{ eV}.

Final answer

(a) Slope=4.14×10−15 V⋅s\text{Slope} = 4.14 \times 10^{-15}\text{ V}\cdot\text{s}; (b) h=6.63×10−34 J⋅sh = 6.63 \times 10^{-34}\text{ J}\cdot\text{s}, with a percentage error of +0.06%+0.06\%; (c) Φ=2.19 eV\Phi = 2.19\text{ eV}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice tabulating linear regression sums (∑x,∑y,∑x2,∑xy)(\sum x, \sum y, \sum x^2, \sum xy) directly from experimental data tables.

  • Always use the centroid formula c=yˉ−mxˉc = \bar{y} - m\bar{x} to extract intercepts from best-fit lines.

  • Avoid using two-point slope estimates when an exercise specifies linear regression.

OverviewACEpath Teacher's Diagnosis

02 The student forgets that the vertical intercept is in volts (-Φ/e) and unnecessarily multiplies by the elementary charge when stating the work function in eV, confusing joules and electron-volts.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    fˉ=7.5196×1014 Hz, Vˉ0=0.9214 V  ⟹  m=∑(fi−fˉ)(V0,i−Vˉ0)∑(fi−fˉ)2=4.137×10−15 V⋅s  ⟹  he=4.137×10−15 V⋅s\bar{f} = 7.5196 \times 10^{14}\text{ Hz},\ \bar{V}_0 = 0.9214\text{ V} \implies m = \frac{\sum (f_i - \bar{f})(V_{0,i} - \bar{V}_0)}{\sum (f_i - \bar{f})^2} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s} \implies \frac{h}{e} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s}

  2. Step 2

    h=(4.137×10−15)(1.602×10−19)=6.628×10−34 J⋅s  ⟹  Percentage error=∣6.628×10−34−6.626×10−34∣6.626×10−34×100%=0.03%h = (4.137 \times 10^{-15})(1.602 \times 10^{-19}) = 6.628 \times 10^{-34}\text{ J}\cdot\text{s} \implies \text{Percentage error} = \frac{|6.628 \times 10^{-34} - 6.626 \times 10^{-34}|}{6.626 \times 10^{-34}} \times 100\% = 0.03\%

  3. Step 3

    Intercept c=Vˉ0−mfˉ=0.9214−(4.1371×10−15)(7.5196×1014)=−2.190 V\text{Intercept } c = \bar{V}_0 - m\bar{f} = 0.9214 - (4.1371 \times 10^{-15})(7.5196 \times 10^{14}) = -2.190\text{ V}

  4. Step 4

    Φ=2.190×1.602×10−19=3.508×10−19 eV\Phi = 2.190 \times 1.602 \times 10^{-19} = 3.508 \times 10^{-19}\text{ eV}

    Correct

    Φ=2.19 eV\Phi = 2.19\text{ eV}

    From Einstein's photoelectric equation, the vertical intercept equals −Φe=−2.190 V-\frac{\Phi}{e} = -2.190\text{ V}, which means the potential is 2.190 V2.190\text{ V}. Multiplying a potential in volts by the elementary charge ee yields energy in electron-volts directly as Φ=2.190 eV\Phi = 2.190\text{ eV}. Multiplying the numerical magnitude by 1.602×10−19 C1.602 \times 10^{-19}\text{ C} gives the energy in Joules (3.51×10−19 J3.51 \times 10^{-19}\text{ J}), not eV\text{eV}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the least-squares formula to compute the experimental slope he\frac{h}{e}.

You correctly evaluated Planck's constant hh in J⋅s\text{J}\cdot\text{s} and computed the percentage discrepancy.

You correctly calculated the vertical intercept c=−2.190 Vc = -2.190\text{ V} from the centroid coordinates.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Conversion Error (eV vs. Joules)

You performed the numerical multiplication by 1.602×10−191.602 \times 10^{-19} (which converts eV\text{eV} to J\text{J}) but kept the unit label as eV\text{eV}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the unit definition of the electron-volt (eV\text{eV}) with the conversion factor to Joules. When an equation gives a potential in volts (V0=2.19 VV_0 = 2.19\text{ V}), an electron traversing this potential has an energy of exactly 2.19 eV2.19\text{ eV} without any numerical multiplication by 1.602×10−191.602 \times 10^{-19}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Definition of the Electron-Volt
  • By definition, an energy of 1 eV1\text{ eV} is the energy gained or lost by an elementary charge ee across a potential difference of 1 V1\text{ V}. Therefore, E [in eV]=V [in V]E\text{ [in eV]} = V\text{ [in V]}.

  • If the intercept is −Φe=−Vc-\frac{\Phi}{e} = -V_c, read off the work function directly as Φ=Vc eV\Phi = V_c\text{ eV}.

Converting Between Joules and Electron-Volts
  • 1 eV=1.602×10−19 J1\text{ eV} = 1.602 \times 10^{-19}\text{ J}. To convert J→eV\text{J} \to \text{eV}, divide by 1.602×10−191.602 \times 10^{-19}. To convert eV→J\text{eV} \to \text{J}, multiply by 1.602×10−191.602 \times 10^{-19}.

  • Always verify whether the requested unit is eV\text{eV} or J\text{J} before introducing the factor 1.602×10−191.602 \times 10^{-19}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set the theoretical vertical intercept equal to the experimental value: −Φe=−2.190 V-\frac{\Phi}{e} = -2.190\text{ V}.

  2. Solve for the ratio: Φe=2.190 V\frac{\Phi}{e} = 2.190\text{ V}.

  3. Multiply both sides by ee: Φ=2.190 eV\Phi = 2.190\text{ eV}.

Final answer

(a) 4.14×10−15 V⋅s4.14 \times 10^{-15}\text{ V}\cdot\text{s}; (b) h=6.63×10−34 J⋅sh = 6.63 \times 10^{-34}\text{ J}\cdot\text{s} (error +0.06%+0.06\%); (c) Φ=2.19 eV\Phi = 2.19\text{ eV}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice reading work functions directly from V0 vs. fV_0\text{ vs. }f graph intercepts without redundant factor conversions.

  • Check units explicitly at every step: potential difference in V\text{V} directly corresponds to electron energy in eV\text{eV}.

OverviewACEpath Teacher's Diagnosis

03 The student divides the experimental slope by the elementary charge instead of multiplying by e when calculating Planck's constant.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    fˉ=7.5196×1014 Hz,Vˉ0=0.9214 V  ⟹  m=∑(fi−fˉ)(V0,i−Vˉ0)∑(fi−fˉ)2=4.137×10−15 V⋅s  ⟹  he=4.137×10−15 V⋅s\bar{f} = 7.5196 \times 10^{14}\text{ Hz},\quad \bar{V}_0 = 0.9214\text{ V} \implies m = \frac{\sum (f_i - \bar{f})(V_{0,i} - \bar{V}_0)}{\sum (f_i - \bar{f})^2} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s} \implies \frac{h}{e} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s}

  2. Step 2

    h=(h/e)e=4.137×10−151.602×10−19=2.582×104 J⋅sh = \frac{(h/e)}{e} = \frac{4.137 \times 10^{-15}}{1.602 \times 10^{-19}} = 2.582 \times 10^4\text{ J}\cdot\text{s}

    Correct

    h=(he)⋅e=(4.137×10−15 V⋅s)(1.602×10−19 C)≈6.63×10−34 J⋅sh = \left(\frac{h}{e}\right) \cdot e = (4.137 \times 10^{-15}\text{ V}\cdot\text{s})(1.602 \times 10^{-19}\text{ C}) \approx 6.63 \times 10^{-34}\text{ J}\cdot\text{s}

    To isolate hh from the ratio he\frac{h}{e}, you must multiply by ee rather than divide by ee. Dividing yields he2\frac{h}{e^2}, which has units of V⋅s/C\text{V}\cdot\text{s}/\text{C} instead of J⋅s\text{J}\cdot\text{s}.

  3. Step 3

    Percentage error=∣2.582×104−6.626×10−34∣6.626×10−34×100%=3.90×1039%\text{Percentage error} = \frac{|2.582 \times 10^4 - 6.626 \times 10^{-34}|}{6.626 \times 10^{-34}} \times 100\% = 3.90 \times 10^{39}\%

    Correct

    Percentage error=6.628×10−34−6.626×10−346.626×10−34×100%≈+0.06%\text{Percentage error} = \frac{6.628 \times 10^{-34} - 6.626 \times 10^{-34}}{6.626 \times 10^{-34}} \times 100\% \approx +0.06\%

    Your percentage error formula is set up properly, but the result is skewed because of the incorrect value of hh propagated from the previous step.

  4. Step 4

    c=Vˉ0−mfˉ=−2.190 V  ⟹  Φ=−(−2.190)=2.190 eVc = \bar{V}_0 - m\bar{f} = -2.190\text{ V} \implies \Phi = -(-2.190) = 2.190\text{ eV}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used standard linear regression formulas to find the experimental slope he\frac{h}{e}.

You recognized that the vertical intercept equals −Φe-\frac{\Phi}{e} and correctly converted the potential intercept in volts to a work function in electron-volts.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Algebraic Isolation / Dimensional Analysis

Dividing the quotient he\frac{h}{e} by ee instead of multiplying by ee to isolate hh.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the slope he\frac{h}{e} as if it were h⋅eh \cdot e, leading you to divide by ee instead of multiplying by ee to clear the denominator. Checking the dimensions of your result ( V⋅C⋅s=J⋅s\,\text{V}\cdot\text{C}\cdot\text{s} = \text{J}\cdot\text{s}) or observing the unphysical exponent (10410^4) would immediately flag this inversion.

REASONING PATH
Your ACEpath teacher’s suggested approach
Clearing Denominators
  • If a measured quantity represents a ratio AB\frac{A}{B}, the numerator is recovered by A=(AB)×BA = \left(\frac{A}{B}\right) \times B.

  • Multiply the slope by ee: h=Slope×eh = \text{Slope} \times e.

Order-of-Magnitude & Unit Sanity Check
  • Planck's constant has the dimension of action (J⋅s\text{J}\cdot\text{s}) and an order of magnitude of 10−34 J⋅s10^{-34}\text{ J}\cdot\text{s}.

  • Check whether your result has an exponent near −34-34; an exponent near +4+4 indicates an inverted factor of 10−1910^{-19}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Multiply the experimental slope he=4.137×10−15 V⋅s\frac{h}{e} = 4.137 \times 10^{-15}\text{ V}\cdot\text{s} by e=1.602×10−19 Ce = 1.602 \times 10^{-19}\text{ C}:

  2. h=(4.137×10−15 V⋅s)×(1.602×10−19 C)=6.628×10−34 J⋅sh = (4.137 \times 10^{-15}\text{ V}\cdot\text{s}) \times (1.602 \times 10^{-19}\text{ C}) = 6.628 \times 10^{-34}\text{ J}\cdot\text{s}

  3. Calculate the relative percentage error against the accepted value 6.626×10−34 J⋅s6.626 \times 10^{-34}\text{ J}\cdot\text{s}:

  4. Error=6.628×10−34−6.626×10−346.626×10−34×100%≈+0.03% to +0.06%\text{Error} = \frac{6.628 \times 10^{-34} - 6.626 \times 10^{-34}}{6.626 \times 10^{-34}} \times 100\% \approx +0.03\% \text{ to } +0.06\%

Final answer

(a) he=4.14×10−15 V⋅s\frac{h}{e} = 4.14 \times 10^{-15}\text{ V}\cdot\text{s}; (b) h=6.63×10−34 J⋅sh = 6.63 \times 10^{-34}\text{ J}\cdot\text{s} with +0.06%+0.06\% error; (c) Φ=2.19 eV\Phi = 2.19\text{ eV}

NEXT STEPS
Final Takeaways from Your Teacher
  • Perform unit tracking on every slope calculation: verify that (V⋅s)×C=J⋅s(\text{V}\cdot\text{s}) \times \text{C} = \text{J}\cdot\text{s}.

  • Always evaluate whether the calculated physical constant matches expected physical scales before proceeding to percentage error.

Lock it in

Similar question

01

In a photoelectric experiment, three data points (f,V0)(f, V_0) are measured: (5.0×1014 Hz,0.50 V)(5.0 \times 10^{14}\text{ Hz}, 0.50\text{ V}), (6.0×1014 Hz,0.92 V)(6.0 \times 10^{14}\text{ Hz}, 0.92\text{ V}), and (7.0×1014 Hz,1.30 V)(7.0 \times 10^{14}\text{ Hz}, 1.30\text{ V}). Using least-squares linear regression, calculate the experimental slope m=hem = \frac{h}{e}.

Answer

With x=f/1014x = f/10^{14}, xˉ=6.0\bar{x} = 6.0, yˉ=0.9067 V\bar{y} = 0.9067\text{ V}, ∑(xi−xˉ)2=2.0\sum (x_i - \bar{x})^2 = 2.0, and ∑(xi−xˉ)(yi−yˉ)=(−1)(−0.4067)+(0)+(1)(0.3933)=0.80 V\sum (x_i - \bar{x})(y_i - \bar{y}) = (-1)(-0.4067) + (0) + (1)(0.3933) = 0.80\text{ V}. Thus, m=0.802.0×10−14=4.00×10−15 V⋅sm = \frac{0.80}{2.0} \times 10^{-14} = 4.00 \times 10^{-15}\text{ V}\cdot\text{s}.

02

Using the linear fit from the previous question where m=4.00×10−15 V⋅sm = 4.00 \times 10^{-15}\text{ V}\cdot\text{s}, fˉ=6.0×1014 Hz\bar{f} = 6.0 \times 10^{14}\text{ Hz}, and Vˉ0=0.907 V\bar{V}_0 = 0.907\text{ V}, determine the work function Φ\Phi of the emitter in eV\text{eV}.

Answer

Calculate the intercept c=Vˉ0−mfˉ=0.907−(4.00×10−15)(6.0×1014)=0.907−2.400=−1.493 Vc = \bar{V}_0 - m\bar{f} = 0.907 - (4.00 \times 10^{-15})(6.0 \times 10^{14}) = 0.907 - 2.400 = -1.493\text{ V}. Since c=−Φec = -\frac{\Phi}{e}, Φ=1.49 eV\Phi = 1.49\text{ eV}.

03

A student obtains a linear regression line V0=(4.10×10−15 V⋅s)f−2.05 VV_0 = (4.10 \times 10^{-15}\text{ V}\cdot\text{s}) f - 2.05\text{ V}. Find the threshold frequency f0f_0 for photoemission and Planck's constant hh using e=1.602×10−19 Ce = 1.602 \times 10^{-19}\text{ C}.

Answer

At threshold, V0=0  ⟹  f0=Φ/eh/e=2.05 V4.10×10−15 V⋅s=5.00×1014 HzV_0 = 0 \implies f_0 = \frac{\Phi/e}{h/e} = \frac{2.05\text{ V}}{4.10 \times 10^{-15}\text{ V}\cdot\text{s}} = 5.00 \times 10^{14}\text{ Hz}. Planck's constant is h=m⋅e=(4.10×10−15 V⋅s)(1.602×10−19 C)=6.57×10−34 J⋅sh = m \cdot e = (4.10 \times 10^{-15}\text{ V}\cdot\text{s})(1.602 \times 10^{-19}\text{ C}) = 6.57 \times 10^{-34}\text{ J}\cdot\text{s}.

Loading workspace…