Resources

A compact medical solenoid designed for localized magnetic therapies is wound with n=45.0 turns/cmn = 45.0\text{ turns/cm}. An engineering technician measures the internal axial magnetic field to be B=35.0 GB = 35.0\text{ G} (gauss). (a) Convert the winding density to turns per meter (m−1\text{m}^{-1}) and the magnetic field to teslas (T\text{T}). (b) Calculate the required operating current II in amperes. (c) A flat circular exploration probe with an area of A=2.50 cm2A = 2.50\text{ cm}^2 is inserted inside the central bore of the solenoid. Calculate the magnetic flux ΦB\Phi_B through the probe in webers (Wb\text{Wb}) and maxwells (Mx\text{Mx}) when the probe's surface normal is tilted at an angle of 37.0∘37.0^\circ relative to the central field lines.

Answer and steps

Final answer

(a) n=4.50×103 turns/mn = 4.50\times 10^3\text{ turns/m}, B=3.50×10−3 TB = 3.50\times 10^{-3}\text{ T}; (b) I=0.619 AI = 0.619\text{ A}; (c) ΦB=6.99×10−7 Wb=69.9 Mx\Phi_B = 6.99\times 10^{-7}\text{ Wb} = 69.9\text{ Mx}

Steps

Part (a): Unit Conversions

  1. Winding density (nn):
    The number of turns per centimeter is converted to SI units (turns per meter) using the conversion factor 1 m=100 cm1\text{ m} = 100\text{ cm}: n=45.0 turns/cm×100 cm1 m=4500 turns/m=4.50×103 turns/mn = 45.0\text{ turns/cm} \times \frac{100\text{ cm}}{1\text{ m}} = 4500\text{ turns/m} = 4.50\times 10^3\text{ turns/m}
  2. Magnetic field (BB):
    Gauss (G\text{G}) relates to tesla (T\text{T}) by the relation 1 G=10−4 T1\text{ G} = 10^{-4}\text{ T}: B=35.0 G×10−4 T/G=3.50×10−3 TB = 35.0\text{ G} \times 10^{-4}\text{ T/G} = 3.50\times 10^{-3}\text{ T}

Part (b): Operating Current (II)

The magnetic field inside an ideal, tightly wound long solenoid is uniform along its central axis and given by Ampère's Law: B=μ0nIB = \mu_0 n I

where μ0=4π×10−7 T⋅m/A\mu_0 = 4\pi \times 10^{-7}\text{ T}\cdot\text{m/A} is the permeability of free space.

Rearranging to solve for the current II: I=Bμ0nI = \frac{B}{\mu_0 n}

Substitute the values: I=3.50×10−3 T(4π×10−7 T⋅m/A)(4.50×103 m−1)≈3.50×10−35.655×10−3≈0.619 AI = \frac{3.50\times 10^{-3}\text{ T}}{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(4.50\times 10^3\text{ m}^{-1})} \approx \frac{3.50\times 10^{-3}}{5.655\times 10^{-3}} \approx 0.619\text{ A}


Part (c): Magnetic Flux (ΦB\Phi_B)

Magnetic flux ΦB\Phi_B through a flat surface of area AA in a uniform magnetic field B⃗\vec{B} is defined as: ΦB=B⃗⋅A⃗=BAcos⁡θ\Phi_B = \vec{B} \cdot \vec{A} = B A \cos\theta

where:

  • A=2.50 cm2=2.50×10−4 m2A = 2.50\text{ cm}^2 = 2.50 \times 10^{-4}\text{ m}^2
  • θ=37.0∘\theta = 37.0^\circ is the angle between the probe's surface normal vector n^\hat{n} and the magnetic field B⃗\vec{B}

Common Pitfall: Always verify whether the given angle is measured between the field and the surface normal or the surface plane. Here, the angle is explicitly between the surface normal and the field lines, so cos⁡θ=cos⁡(37.0∘)\cos\theta = \cos(37.0^\circ) applies directly.

  1. In Webers (Wb\text{Wb}): ΦB=(3.50×10−3 T)(2.50×10−4 m2)cos⁡(37.0∘)\Phi_B = (3.50\times 10^{-3}\text{ T})(2.50\times 10^{-4}\text{ m}^2)\cos(37.0^\circ) ΦB=(8.75×10−7 T⋅m2)(0.7986)≈6.99×10−7 Wb\Phi_B = (8.75\times 10^{-7}\text{ T}\cdot\text{m}^2)(0.7986) \approx 6.99\times 10^{-7}\text{ Wb}
  2. In Maxwells (Mx\text{Mx}):
    Since 1 Wb=108 Mx1\text{ Wb} = 10^8\text{ Mx}: ΦB=6.99×10−7 Wb×108 Mx/Wb=69.9 Mx\Phi_B = 6.99\times 10^{-7}\text{ Wb} \times 10^8\text{ Mx/Wb} = 69.9\text{ Mx}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the linear conversion factor when converting the probe area from cm² to m², using 10⁻² instead of 10⁻⁴.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    n=45.0×100=4500 turns/mn = 45.0 \times 100 = 4500\text{ turns/m} ⟹ B=35.0×10−4 T=3.50×10−3 TB = 35.0 \times 10^{-4}\text{ T} = 3.50 \times 10^{-3}\text{ T}

  2. Step 2

    B=μ0nIB = \mu_0 n I ⟹ I=Bμ0n=3.50×10−34π×10−7×4500=0.619 AI = \frac{B}{\mu_0 n} = \frac{3.50 \times 10^{-3}}{4\pi \times 10^{-7} \times 4500} = 0.619\text{ A}

  3. Step 3

    A=2.50×10−2 m2A = 2.50 \times 10^{-2}\text{ m}^2

    Correct

    A=2.50 cm2×(10−2 m/cm)2=2.50×10−4 m2A = 2.50\text{ cm}^2 \times \left(10^{-2}\text{ m/cm}\right)^2 = 2.50 \times 10^{-4}\text{ m}^2

    You used the linear conversion prefix 10−210^{-2} rather than squaring it for area. Because 1 cm=10−2 m1\text{ cm} = 10^{-2}\text{ m}, 1 cm2=(10−2 m)2=10−4 m21\text{ cm}^2 = (10^{-2}\text{ m})^2 = 10^{-4}\text{ m}^2.

  4. Step 4

    ΦB=BAcos⁡(37.0∘)=(3.50×10−3 T)(2.50×10−2 m2)cos⁡(37.0∘)=6.99×10−5 Wb\Phi_B = B A \cos(37.0^\circ) = (3.50 \times 10^{-3}\text{ T})(2.50 \times 10^{-2}\text{ m}^2)\cos(37.0^\circ) = 6.99 \times 10^{-5}\text{ Wb} ⟹ ΦB=6.99×10−5×108 Mx=6990 Mx\Phi_B = 6.99 \times 10^{-5} \times 10^8\text{ Mx} = 6990\text{ Mx}

    Correct

    ΦB=(3.50×10−3 T)(2.50×10−4 m2)cos⁡(37.0∘)≈6.99×10−7 Wb\Phi_B = (3.50 \times 10^{-3}\text{ T})(2.50 \times 10^{-4}\text{ m}^2)\cos(37.0^\circ) \approx 6.99 \times 10^{-7}\text{ Wb} ⟹ ΦB=6.99×10−7 Wb×108 Mx/Wb=69.9 Mx\Phi_B = 6.99 \times 10^{-7}\text{ Wb} \times 10^8\text{ Mx/Wb} = 69.9\text{ Mx}

    Your formula and angle setup were completely correct, but the calculated flux values were off by a factor of 100100 due to the area conversion in Step 3.

WHAT YOU DID WELL
Compliments from Your Teacher

You converted both linear turn density and gauss to SI units accurately in part (a).

You used the correct solenoid field equation B=μ0nIB = \mu_0 n I and solved for the operating current precisely.

You correctly used the surface normal angle directly in ΦB=BAcos⁡θ\Phi_B = B A \cos\theta and knew the conversion factor between webers and maxwells (1 Wb=108 Mx1\text{ Wb} = 10^8\text{ Mx}).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion power error (area)

You wrote 1 cm2=10−2 m21\text{ cm}^2 = 10^{-2}\text{ m}^2 instead of squaring the metric prefix to obtain 10−4 m210^{-4}\text{ m}^2.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Applying linear SI prefixes directly to derived geometric units (area or volume) without raising the conversion factor to the corresponding power (22 for area, 33 for volume).

REASONING PATH
Your ACEpath teacher’s suggested approach
Square the prefix for area
  • 1 cm=10−2 m  ⟹  1 cm2=(10−2 m)2=10−4 m21\text{ cm} = 10^{-2}\text{ m} \implies 1\text{ cm}^2 = (10^{-2}\text{ m})^2 = 10^{-4}\text{ m}^2

  • Always write out parentheses around both the value and the unit prefix before squaring: (10−2 m)2(10^{-2}\text{ m})^2.

Reasonableness check on area
  • A sheet of paper is roughly 0.06 m20.06\text{ m}^2; an area of 10−2 m210^{-2}\text{ m}^2 is a 10 cm×10 cm10\text{ cm} \times 10\text{ cm} square.

  • Check whether your calculated area matches physical scale: a small probe of 2.5 cm22.5\text{ cm}^2 cannot be a substantial fraction of a square meter.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert area properly: A=2.50 cm2×(1 m100 cm)2=2.50×10−4 m2A = 2.50\text{ cm}^2 \times \left(\frac{1\text{ m}}{100\text{ cm}}\right)^2 = 2.50 \times 10^{-4}\text{ m}^2.

  2. Substitute into the flux formula: ΦB=(3.50×10−3 T)(2.50×10−4 m2)cos⁡(37.0∘)=6.99×10−7 Wb\Phi_B = (3.50 \times 10^{-3}\text{ T})(2.50 \times 10^{-4}\text{ m}^2)\cos(37.0^\circ) = 6.99 \times 10^{-7}\text{ Wb}.

  3. Convert to maxwells: ΦB=6.99×10−7 Wb×108 Mx/Wb=69.9 Mx\Phi_B = 6.99 \times 10^{-7}\text{ Wb} \times 10^8\text{ Mx/Wb} = 69.9\text{ Mx}.

Final answer

(a) n=4.50×103 turns/mn = 4.50 \times 10^3\text{ turns/m}, B=3.50×10−3 TB = 3.50 \times 10^{-3}\text{ T}; (b) I=0.619 AI = 0.619\text{ A}; (c) ΦB=6.99×10−7 Wb=69.9 Mx\Phi_B = 6.99 \times 10^{-7}\text{ Wb} = 69.9\text{ Mx}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting non-SI area units (such as cm2\text{cm}^2 and mm2\text{mm}^2) into m2\text{m}^2 using explicit exponent notation.

  • Rework part (c) with A=2.50×10−4 m2A = 2.50 \times 10^{-4}\text{ m}^2 to confirm both flux representations.

OverviewACEpath Teacher's Diagnosis

02 The student uses the sine of the angle rather than the cosine when calculating magnetic flux, confusing the surface normal angle with the plane angle.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    n=45.0×100=4500 turns/mn = 45.0 \times 100 = 4500\text{ turns/m} ⟹ B=35.0×10−4 T=3.50×10−3 TB = 35.0 \times 10^{-4}\text{ T} = 3.50 \times 10^{-3}\text{ T}

  2. Step 2

    B=μ0nIB = \mu_0 n I ⟹ I=Bμ0n=3.50×10−34π×10−7×4500=0.619 AI = \frac{B}{\mu_0 n} = \frac{3.50 \times 10^{-3}}{4\pi \times 10^{-7} \times 4500} = 0.619\text{ A}

  3. Step 3

    A=2.50×10−4 m2A = 2.50 \times 10^{-4}\text{ m}^2 ⟹ ΦB=BAsin⁡(37.0∘)=(3.50×10−3)(2.50×10−4)sin⁡(37.0∘)=5.27×10−7 Wb\Phi_B = B A \sin(37.0^\circ) = (3.50 \times 10^{-3})(2.50 \times 10^{-4})\sin(37.0^\circ) = 5.27 \times 10^{-7}\text{ Wb}

    Correct

    ΦB=BAcos⁡(37.0∘)=(3.50×10−3 T)(2.50×10−4 m2)cos⁡(37.0∘)≈6.99×10−7 Wb\Phi_B = B A \cos(37.0^\circ) = (3.50 \times 10^{-3}\text{ T})(2.50 \times 10^{-4}\text{ m}^2)\cos(37.0^\circ) \approx 6.99 \times 10^{-7}\text{ Wb}

    You used sin⁡(37.0∘)\sin(37.0^\circ) instead of cos⁡(37.0∘)\cos(37.0^\circ). Magnetic flux is defined by the dot product B⃗⋅A⃗=BAcos⁡θ\vec{B}\cdot\vec{A} = B A \cos\theta, where θ\theta is the angle between the magnetic field and the surface normal.

  4. Step 4

    ΦB=5.27×10−7×108 Mx=52.7 Mx\Phi_B = 5.27 \times 10^{-7} \times 10^8\text{ Mx} = 52.7\text{ Mx}

    Correct

    ΦB=6.99×10−7 Wb×108 Mx/Wb=69.9 Mx\Phi_B = 6.99 \times 10^{-7}\text{ Wb} \times 10^8\text{ Mx/Wb} = 69.9\text{ Mx}

    Your unit conversion factor from webers to maxwells (1 Wb=108 Mx1\text{ Wb} = 10^8\text{ Mx}) was correct, but the final value carried over the error from using sine.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the solenoid winding density to turns/m\text{turns/m} and the magnetic field to teslas.

You set up and evaluated the magnetic field inside an ideal solenoid to find the current II.

You converted the probe area accurately to m2\text{m}^2 and used the correct factor 108 Mx/Wb10^8\text{ Mx/Wb}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Trigonometric Function Confusion in Dot Product

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the angle between the magnetic field and the surface normal with the angle between the magnetic field and the plane of the loop. The dot product definition of flux ΦB=B⃗⋅A⃗=BAcos⁡θ\Phi_B = \vec{B}\cdot\vec{A} = BA\cos\theta directly takes cos⁡θ\cos\theta when θ\theta is measured with respect to the normal vector.

REASONING PATH
Your ACEpath teacher’s suggested approach
Identifying the Reference Axis for $\theta$
  • In ΦB=BAcos⁡θ\Phi_B = BA\cos\theta, θ\theta must be measured from the surface normal n^\hat{n} to B⃗\vec{B}.

  • Check whether the problem specifies the angle relative to the 'surface normal' (use cos⁡θ\cos\theta) or the 'plane of the surface' (use sin⁡α\sin\alpha or cos⁡(90∘−α)\cos(90^\circ - \alpha)).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recognize that θ=37.0∘\theta = 37.0^\circ is measured directly from the surface normal to B⃗\vec{B}, so ΦB=BAcos⁡(37.0∘)\Phi_B = B A \cos(37.0^\circ).

  2. Calculate flux in webers: ΦB=(3.50×10−3 T)(2.50×10−4 m2)cos⁡(37.0∘)=6.99×10−7 Wb\Phi_B = (3.50 \times 10^{-3}\text{ T})(2.50 \times 10^{-4}\text{ m}^2)\cos(37.0^\circ) = 6.99 \times 10^{-7}\text{ Wb}.

  3. Convert to maxwells using 1 Wb=108 Mx1\text{ Wb} = 10^8\text{ Mx}: ΦB=6.99×10−7×108=69.9 Mx\Phi_B = 6.99 \times 10^{-7} \times 10^8 = 69.9\text{ Mx}.

Final answer

(a) n=4.50×103 turns/mn = 4.50\times 10^3\text{ turns/m}, B=3.50×10−3 TB = 3.50\times 10^{-3}\text{ T}; (b) I=0.619 AI = 0.619\text{ A}; (c) ΦB=6.99×10−7 Wb=69.9 Mx\Phi_B = 6.99\times 10^{-7}\text{ Wb} = 69.9\text{ Mx}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always draw the area vector n^\hat{n} perpendicular to the surface before writing down the flux formula.

  • Check if the given angle is relative to the normal n^\hat{n} or the surface face: if relative to n^\hat{n}, always use cosine.

OverviewACEpath Teacher's Diagnosis

03 The student divides by 100 instead of multiplying by 100 when converting turns/cm to turns/m, resulting in an incorrect turns per meter value of 0.45 turns/m.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    n=45.0100=0.45 turns/mn = \frac{45.0}{100} = 0.45\text{ turns/m}

    Correct

    n=45.0 turns/cm×100 cm1 m=4.50×103 turns/mn = 45.0\text{ turns/cm} \times \frac{100\text{ cm}}{1\text{ m}} = 4.50\times 10^3\text{ turns/m}

    Centimeters are in the denominator of turns/cm\text{turns/cm}. Since 1 m=100 cm1\text{ m} = 100\text{ cm}, there are 100100 times more turns in one full meter than in one centimeter, so you need to multiply by 100100 rather than divide.

  2. Step 2

    B=35.0×10−4 T=3.50×10−3 TB = 35.0 \times 10^{-4}\text{ T} = 3.50 \times 10^{-3}\text{ T}

  3. Step 3

    B=μ0nI  ⟹  I=Bμ0n=3.50×10−34π×10−7×0.45=6189 AB = \mu_0 n I \implies I = \frac{B}{\mu_0 n} = \frac{3.50 \times 10^{-3}}{4\pi \times 10^{-7} \times 0.45} = 6189\text{ A}

    Correct

    I=Bμ0n=3.50×10−3 T(4π×10−7 T⋅m/A)(4.50×103 m−1)≈0.619 AI = \frac{B}{\mu_0 n} = \frac{3.50 \times 10^{-3}\text{ T}}{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(4.50\times 10^3\text{ m}^{-1})} \approx 0.619\text{ A}

    Your algebraic rearrangement and substitution structure were completely correct, but the calculation inherited your incorrect winding density n=0.45 turns/mn = 0.45\text{ turns/m} from Step 1.

  4. Step 4

    A=2.50×10−4 m2  ⟹  ΦB=BAcos⁡(37.0∘)=(3.50×10−3)(2.50×10−4)cos⁡(37.0∘)=6.99×10−7 Wb  ⟹  ΦB=6.99×10−7×108 Mx=69.9 MxA = 2.50 \times 10^{-4}\text{ m}^2 \implies \Phi_B = B A \cos(37.0^\circ) = (3.50 \times 10^{-3})(2.50 \times 10^{-4})\cos(37.0^\circ) = 6.99 \times 10^{-7}\text{ Wb} \implies \Phi_B = 6.99 \times 10^{-7} \times 10^8\text{ Mx} = 69.9\text{ Mx}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted gauss to teslas using the standard factor 1 G=10−4 T1\text{ G} = 10^{-4}\text{ T}.

You correctly applied Ampère's law for a long solenoid, B=μ0nIB = \mu_0 n I, and rearranged it to isolate current II.

You properly converted square centimeters to square meters and evaluated the magnetic flux through the tilted probe in both SI and CGS units.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Denominator unit conversion inversion

Dividing by 100100 when converting a unit whose length dimension is in the denominator (extturns/cm ext{turns/cm} to extturns/m ext{turns/m}).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the centimeter-to-meter conversion as a standard direct length conversion (dividing by 100100) rather than recognizing that centimeters appear in the denominator of linear density (1/cm=100/m1/\text{cm} = 100/\text{m}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Denominator Unit Cancellation
  • When a prefix is in the denominator, the conversion factor must place that unit in the numerator to cancel: turnscm×100 cm1 m=turnsm\frac{\text{turns}}{\text{cm}} \times \frac{100\text{ cm}}{1\text{ m}} = \frac{\text{turns}}{\text{m}}.

  • Write unit conversion factors with explicit fraction bars and cancel units explicitly before multiplying or dividing numerical values.

Physical Sanity Check for Solenoid Density
  • A meter is 100100 times longer than a centimeter, so a tight coil must pack 100100 times more wire loops in a meter than in a centimeter.

  • Ask yourself whether the physical quantity should get larger or smaller over a longer distance before finalizing your arithmetic.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Substitute the correct winding density n=4.50×103 m−1n = 4.50\times 10^3\text{ m}^{-1} into I=Bμ0nI = \frac{B}{\mu_0 n}.

  2. Evaluate the denominator: μ0n=(4π×10−7 T⋅m/A)(4500 m−1)≈5.655×10−3 T/A\mu_0 n = (4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(4500\text{ m}^{-1}) \approx 5.655\times 10^{-3}\text{ T/A}.

  3. Compute the current: I=3.50×10−3 T5.655×10−3 T/A≈0.619 AI = \frac{3.50\times 10^{-3}\text{ T}}{5.655\times 10^{-3}\text{ T/A}} \approx 0.619\text{ A}.

Final answer

(a) n=4.50×103 turns/mn = 4.50\times 10^3\text{ turns/m}, B=3.50×10−3 TB = 3.50\times 10^{-3}\text{ T}; (b) I=0.619 AI = 0.619\text{ A}; (c) ΦB=6.99×10−7 Wb=69.9 Mx\Phi_B = 6.99\times 10^{-7}\text{ Wb} = 69.9\text{ Mx}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write out dimensional analysis explicitly with canceling units whenever converting rates or densities with units in the denominator.

  • Perform an order-of-magnitude check on calculated current: thousands of amperes would vaporize a compact medical solenoid, signaling an inverted density factor.

Lock it in

Similar question

01

A square sensor with side length s=4.0 cms = 4.0\text{ cm} is placed perpendicular to a uniform magnetic field of B=0.15 TB = 0.15\text{ T}. Calculate the magnetic flux ΦB\Phi_B through the sensor in webers.

Answer

ΦB=2.4×10−3 Wb\Phi_B = 2.4 \times 10^{-3}\text{ Wb}. Key steps: A=(0.040 m)2=1.6×10−3 m2A = (0.040\text{ m})^2 = 1.6 \times 10^{-3}\text{ m}^2 (or 16 cm2×10−4 m2/cm216\text{ cm}^2 \times 10^{-4}\text{ m}^2/\text{cm}^2). With θ=0∘\theta = 0^\circ, ΦB=BA=(0.15 T)(1.6×10−3 m2)=2.4×10−3 Wb\Phi_B = B A = (0.15\text{ T})(1.6 \times 10^{-3}\text{ m}^2) = 2.4 \times 10^{-3}\text{ Wb}.

02

A solenoid of radius r=2.0 cmr = 2.0\text{ cm} has an axial internal field of B=0.050 TB = 0.050\text{ T}. A small circular loop of area A=6.0 cm2A = 6.0\text{ cm}^2 sits inside the solenoid with its flat face tilted at an angle of 60.0∘60.0^\circ relative to the solenoid's axis (meaning the loop's surface normal is tilted at 30.0∘30.0^\circ to the field lines). Find the magnetic flux through the loop in both webers (Wb\text{Wb}) and maxwells (Mx\text{Mx}).

Answer

ΦB≈2.60×10−5 Wb=2600 Mx\Phi_B \approx 2.60 \times 10^{-5}\text{ Wb} = 2600\text{ Mx}. Key steps: A=6.0×10−4 m2A = 6.0 \times 10^{-4}\text{ m}^2; θ=30.0∘\theta = 30.0^\circ; ΦB=BAcos⁡(30.0∘)=(0.050 T)(6.0×10−4 m2)(0.866)≈2.60×10−5 Wb\Phi_B = B A \cos(30.0^\circ) = (0.050\text{ T})(6.0 \times 10^{-4}\text{ m}^2)(0.866) \approx 2.60 \times 10^{-5}\text{ Wb}; in maxwells, (2.60×10−5 Wb)(108 Mx/Wb)=2.60×103 Mx(2.60 \times 10^{-5}\text{ Wb})(10^8\text{ Mx/Wb}) = 2.60 \times 10^3\text{ Mx}.

03

A compact magnetic pickup coil has N=250 turnsN = 250\text{ turns}, each of cross-sectional area A=1.20 cm2A = 1.20\text{ cm}^2. It is positioned inside a magnetic field that collapses from Bi=0.80 TB_i = 0.80\text{ T} to zero in Δt=40 ms\Delta t = 40\text{ ms}. If the normal to the coil faces is aligned parallel to the field, calculate the magnitude of the average induced electromotive force (EMF) E\mathcal{E} across the coil.

Answer

E=0.60 V\mathcal{E} = 0.60\text{ V}. Key steps: Area per turn A=1.20×10−4 m2A = 1.20 \times 10^{-4}\text{ m}^2; total flux linkage change ΔΦtotal=N(ΔB)A=250×(0.80 T)×(1.20×10−4 m2)=0.024 Wb\Delta \Phi_{\text{total}} = N (\Delta B) A = 250 \times (0.80\text{ T}) \times (1.20 \times 10^{-4}\text{ m}^2) = 0.024\text{ Wb}; by Faraday's law, ∣E∣=ΔΦtotalΔt=0.024 Wb0.040 s=0.60 V|\mathcal{E}| = \frac{\Delta \Phi_{\text{total}}}{\Delta t} = \frac{0.024\text{ Wb}}{0.040\text{ s}} = 0.60\text{ V}.

Loading workspace…