An experimental sensor measures a physical transport coefficient XX whose value is reported in base units as 4.80×10−2 kg⋅m−1⋅s−14.80\times 10^{-2}\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}. An engineer suspects this parameter corresponds to dynamic viscosity η\eta, defined by the shear stress relation τ=ηdvdy\tau = \eta \frac{dv}{dy}, where shear stress τ=FA\tau = \frac{F}{A} has units of pascals (Pa\text{Pa}), vv is flow velocity, and yy is perpendicular distance. Working backwards from the definition of shear stress and velocity gradient, determine whether the derived unit combination Pa⋅s\text{Pa}\cdot\text{s} reduces identically to the base unit signature of XX, and state the equivalent value of XX in derived units of Pa⋅s\text{Pa}\cdot\text{s}.

Answer and steps

Final answer

Yes, Pa⋅s=(Nm2)⋅s=(kg⋅m⋅s−2m2)⋅s=kg⋅m−1⋅s−1\text{Pa}\cdot\text{s} = \left(\frac{\text{N}}{\text{m}^2}\right)\cdot\text{s} = \left(\frac{\text{kg}\cdot\text{m}\cdot\text{s}^{-2}}{\text{m}^2}\right)\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}; X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

Steps

01

Deconstruct the Derived Unit of Pressure into SI Base Units

The pascal (Pa\text{Pa}) is the SI unit of pressure and shear stress, defined as force per unit area:

τ=FA\tau = \frac{F}{A}

  1. From Newton's second law (F=maF = ma), force is measured in newtons (N\text{N}), which expands to: 1 N=1 kg⋅m⋅s−21\text{ N} = 1\text{ kg}\cdot\text{m}\cdot\text{s}^{-2}
  2. Area AA has units of square meters (m2\text{m}^2). Therefore, 1 Pa1\text{ Pa} can be expressed in base units as: 1 Pa=1 N1 m2=kg⋅m⋅s−2m2=kg⋅m−1⋅s−21\text{ Pa} = \frac{1\text{ N}}{1\text{ m}^2} = \frac{\text{kg}\cdot\text{m}\cdot\text{s}^{-2}}{\text{m}^2} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}

02

Multiply by Seconds to Find the Base Unit of Pa⋅s\text{Pa}\cdot\text{s}

Now multiply the base unit expression of pressure by seconds (s\text{s}):

Pa⋅s=(kg⋅m−1⋅s−2)⋅s1=kg⋅m−1⋅s−2+1=kg⋅m−1⋅s−1\text{Pa}\cdot\text{s} = \left(\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}\right)\cdot\text{s}^1 = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2+1} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}

Alternatively, you can verify this directly from the definition of dynamic viscosity η\eta:

η=τdvdy\eta = \frac{\tau}{\frac{dv}{dy}}

The velocity gradient dvdy\frac{dv}{dy} has units of:

m⋅s−1m=s−1\frac{\text{m}\cdot\text{s}^{-1}}{\text{m}} = \text{s}^{-1}

Dividing shear stress (Pa\text{Pa}) by the velocity gradient (s−1\text{s}^{-1}) yields:

[η]=Pas−1=Pa⋅s[\eta] = \frac{\text{Pa}}{\text{s}^{-1}} = \text{Pa}\cdot\text{s}

Since the sensor's reported base unit is kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, the derived unit Pa⋅s\text{Pa}\cdot\text{s} reduces identically to this signature.

Common Pitfall: When simplifying powers of meters, be careful with negative exponents: m1m2=m1−2=m−1\frac{\text{m}^1}{\text{m}^2} = \text{m}^{1-2} = \text{m}^{-1}, not m1\text{m}^1.


03

Express the Physical Quantity in Pa⋅s\text{Pa}\cdot\text{s}

Because 1 Pa⋅s=1 kg⋅m−1⋅s−11\text{ Pa}\cdot\text{s} = 1\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, the conversion factor between these two representations is exactly 11.

Therefore, the equivalent value of XX is:

X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 A student incorrectly simplifies the velocity gradient units as m/s instead of s⁻¹, concluding that Pa·s does not match the base units.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    1 Pa=1 N/m2=(kg⋅m/s2)/m2=kg⋅m−1⋅s−21\text{ Pa} = 1\text{ N/m}^2 = (\text{kg}\cdot\text{m/s}^2)/\text{m}^2 = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}

  2. Step 2

    dvdy has units of m/s  ⟹  Units of η=Pa(m/s)=(kg⋅m−1⋅s−2)(m/s)=kg⋅m−2⋅s−1\frac{dv}{dy}\text{ has units of m/s} \implies \text{Units of }\eta = \frac{\text{Pa}}{(\text{m/s})} = \frac{(\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2})}{(\text{m/s})} = \text{kg}\cdot\text{m}^{-2}\cdot\text{s}^{-1}

    Correct

    [dvdy]=m⋅s−1m=s−1  ⟹  [η]=[τ][dvdy]=Pas−1=Pa⋅s=kg⋅m−1⋅s−1\left[\frac{dv}{dy}\right] = \frac{\text{m}\cdot\text{s}^{-1}}{\text{m}} = \text{s}^{-1} \implies [\eta] = \frac{[\tau]}{\left[\frac{dv}{dy}\right]} = \frac{\text{Pa}}{\text{s}^{-1}} = \text{Pa}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}

    The velocity gradient dvdy\frac{dv}{dy} represents a derivative with respect to distance yy, so its units are velocity divided by distance: m/sm=s−1\frac{\text{m/s}}{\text{m}} = \text{s}^{-1}, not m/s\text{m/s}.

  3. Step 3

    Pa⋅s=(kg⋅m−1⋅s−2)⋅s=kg⋅m−1⋅s−1\text{Pa}\cdot\text{s} = (\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2})\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}

  4. Step 4

    Pa⋅s does not match the formula for η, so X cannot be directly converted to 4.80×10−2 Pa⋅s\text{Pa}\cdot\text{s}\text{ does not match the formula for }\eta\text{, so }X\text{ cannot be directly converted to }4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

    Correct

    Pa⋅s=kg⋅m−1⋅s−1 matches the base unit signature of X identically, so X=4.80×10−2 Pa⋅s\text{Pa}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}\text{ matches the base unit signature of }X\text{ identically, so }X = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

    Because of the miscalculated units of dvdy\frac{dv}{dy} in Step 2, you concluded that Pa⋅s\text{Pa}\cdot\text{s} does not match dynamic viscosity, whereas it reduces identically to kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly decomposed the derived unit of pressure (Pa\text{Pa}) into base units of kg⋅m−1⋅s−2\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}.

You correctly calculated the product of Pa\text{Pa} and s\text{s} in base units as kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Derivative Unit Omission

No, this is a conceptual misunderstanding of dimensional analysis for spatial derivatives and gradients.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You omitted the denominator variable (dydy) when determining the units of the spatial derivative dvdy\frac{dv}{dy}, assigning it the units of vv (m/s\text{m/s}) rather than units of vunits of y=s−1\frac{\text{units of }v}{\text{units of }y} = \text{s}^{-1}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Units of a Derivative
  • For any derivative dfdx\frac{df}{dx}, the unit signature is [f][x]\frac{[f]}{[x]}.

  • Always divide the units of the numerator variable by the units of the denominator variable rather than carrying only the numerator units.

Units of Spatial Gradient
  • A spatial gradient ddy\frac{d}{dy} always introduces a factor of m−1\text{m}^{-1}.

  • Check that velocity gradient dvdy\frac{dv}{dy} has units of m⋅s−1m=s−1\frac{\text{m}\cdot\text{s}^{-1}}{\text{m}} = \text{s}^{-1}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the unit of velocity vv as m⋅s−1\text{m}\cdot\text{s}^{-1} and position yy as m\text{m}.

  2. Compute the unit of the gradient: [dvdy]=m⋅s−1m=s−1\left[\frac{dv}{dy}\right] = \frac{\text{m}\cdot\text{s}^{-1}}{\text{m}} = \text{s}^{-1}.

  3. Rearrange the relation τ=ηdvdy\tau = \eta \frac{dv}{dy} for viscosity: [η]=[τ][dvdy]=Pas−1=Pa⋅s[\eta] = \frac{[\tau]}{\left[\frac{dv}{dy}\right]} = \frac{\text{Pa}}{\text{s}^{-1}} = \text{Pa}\cdot\text{s}.

  4. Observe that Pa⋅s=kg⋅m−1⋅s−1\text{Pa}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, which matches the sensor's reported unit signature identically.

  5. Conclude that 1 Pa⋅s=1 kg⋅m−1⋅s−11\text{ Pa}\cdot\text{s} = 1\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, giving X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}.

Final answer

Yes, Pa⋅s\text{Pa}\cdot\text{s} reduces identically to kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}; X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice finding the SI base units of physical quantities defined by derivatives and integrals.

  • Always write out [numerator][denominator]\frac{[\text{numerator}]}{[\text{denominator}]} explicitly whenever you evaluate a derivative or differential element.

OverviewACEpath Teacher's Diagnosis

02 A student multiplies the base units by seconds instead of reducing Pa·s, incorrectly arriving at a conversion factor containing s².

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    1 Pa=kg⋅m−1⋅s−2  ⟹  1 Pa⋅s=kg⋅m−1⋅s−2⋅s=kg⋅m−1⋅s−11\text{ Pa} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2} \implies 1\text{ Pa}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}

  2. Step 2

    To convert \text{To convert } X  to \text{ to } \text{Pa}$$\cdot$$\text{s},  multiply by \text{ multiply by } s\text{s}:   ⟹  \implies (4.80×\times 10^{-2}\text{ kg}$$\cdot$$\text{m}^{-1}\cdot$$\text{s}^{-1})\cdot$$\text{s} = 4.80×\times 10^{-2}\text{ kg}$$\cdot$$\text{m}^{-1}

    Correct

    Because \text{Because } 1\text{ Pa}$$\cdot$$\text{s} = 1\text{ kg}$$\cdot$$\text{m}^{-1}\cdot$$\text{s}^{-1},  substitute the derived unit directly without modifying the value: \text{ substitute the derived unit directly without modifying the value: } X = 4.80×\times 10^{-2}$\text{ Pa}⋅\cdot\text{s}$$

    You treated the unit name Pa⋅s\text{Pa}\cdot\text{s} as an instruction to multiply the physical quantity XX by an extra factor of seconds. Because 1 Pa⋅s1\text{ Pa}\cdot\text{s} is already identical to 1 kg⋅m−1⋅s−11\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, the conversion factor is simply 11.

  3. Step 3

    \text{Pa}$$\cdot$$\text{s}  does not reduce identically because an extra second factor remains\text{ does not reduce identically because an extra second factor remains}

    Correct

    Yes, Pa⋅s reduces identically to kg⋅m−1⋅s−1\text{Yes, } \text{Pa}\cdot\text{s} \text{ reduces identically to } \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}

    Your own derivation in Step 1 showed exact base-unit equivalence between Pa⋅s\text{Pa}\cdot\text{s} and kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, so no extra factor of seconds remains.

  4. Step 4

    X=4.80×10−2/s Pa⋅sX = 4.80\times 10^{-2}/\text{s }\text{Pa}\cdot\text{s}

    Correct

    X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}

    This result follows directly from the unnecessary division by seconds introduced in your conversion step.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly expressed the base units of the pascal as kg⋅m−1⋅s−2\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}.

You correctly simplified kg⋅m−1⋅s−2⋅s\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}\cdot\text{s} to kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unnecessary dimensional operation on an already equivalent unit

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You conflated showing unit equivalence with performing a dimensional conversion. After correctly verifying that 1 Pa⋅s=1 kg⋅m−1⋅s−11\text{ Pa}\cdot\text{s} = 1\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, you mistakenly believed you had to multiply the measured value by seconds to attach the second from Pa⋅s\text{Pa}\cdot\text{s}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Equivalence vs. Physical Multiplication
  • When a derived unit combination equals the target base-unit signature (1 derived unit=1 base unit signature1\text{ derived unit} = 1\text{ base unit signature}), the numerical value is unchanged.

  • Once you prove that [derived unit]=[base units][\text{derived unit}] = [\text{base units}], substitute the new unit symbol directly into the reported quantity with a conversion factor of 11.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compare the derived unit signature 1 Pa⋅s=kg⋅m−1⋅s−11\text{ Pa}\cdot\text{s} = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1} to the unit of XX: they are identical.

  2. State that Pa⋅s\text{Pa}\cdot\text{s} reduces identically to the base unit combination of XX.

  3. Replace kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1} with Pa⋅s\text{Pa}\cdot\text{s} directly: X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}.

Final answer

Yes, Pa⋅s\text{Pa}\cdot\text{s} reduces identically to kg⋅m−1⋅s−1\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}, and X=4.80×10−2 Pa⋅sX = 4.80\times 10^{-2}\text{ Pa}\cdot\text{s}.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how to convert between equivalent derived and base units without multiplying the quantity.

  • Practice checking whether a conversion factor is dimensionless and equal to 11 before applying algebraic operations.

Lock it in

Similar question

01

Thermal conductivity kk is defined by Fourier's law of heat conduction: dQdt=−kAdTdx\frac{dQ}{dt} = -k A \frac{dT}{dx}, where dQdt\frac{dQ}{dt} is heat transfer rate in watts (W=J/s=kg⋅m2⋅s−3\text{W} = \text{J/s} = \text{kg}\cdot\text{m}^2\cdot\text{s}^{-3}), AA is area in m2\text{m}^2, TT is temperature in kelvins (K\text{K}), and xx is position in meters (m\text{m}). Determine the SI base units of thermal conductivity kk.

Answer

kg⋅m⋅s−3⋅K−1\text{kg}\cdot\text{m}\cdot\text{s}^{-3}\cdot\text{K}^{-1}. Key steps: [dTdx]=Km\left[\frac{dT}{dx}\right] = \frac{\text{K}}{\text{m}}. Rearranging gives [k]=[dQ/dt]A⋅[dT/dx]=kg⋅m2⋅s−3m2⋅(K/m)=kg⋅m⋅s−3⋅K−1[k] = \frac{[dQ/dt]}{A \cdot [dT/dx]} = \frac{\text{kg}\cdot\text{m}^2\cdot\text{s}^{-3}}{\text{m}^2 \cdot (\text{K}/\text{m})} = \text{kg}\cdot\text{m}\cdot\text{s}^{-3}\cdot\text{K}^{-1}.

02

In fluid mechanics, kinematic viscosity ν\nu is defined as the ratio of dynamic viscosity η\eta (unit: Pa⋅s\text{Pa}\cdot\text{s}) to mass density ρ\rho (unit: kg⋅m−3\text{kg}\cdot\text{m}^{-3}). Express the derived unit of kinematic viscosity in SI base units.

Answer

m2⋅s−1\text{m}^2\cdot\text{s}^{-1}. Key steps: [η]=kg⋅m−1⋅s−1[\eta] = \text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1} and [ρ]=kg⋅m−3[\rho] = \text{kg}\cdot\text{m}^{-3}. Dividing gives [ν]=kg⋅m−1⋅s−1kg⋅m−3=m2⋅s−1[\nu] = \frac{\text{kg}\cdot\text{m}^{-1}\cdot\text{s}^{-1}}{\text{kg}\cdot\text{m}^{-3}} = \text{m}^2\cdot\text{s}^{-1}.

03

A one-dimensional diffusion process satisfies Fick's first law: J=−DdCdxJ = -D \frac{dC}{dx}, where JJ is molar flux in mol⋅m−2⋅s−1\text{mol}\cdot\text{m}^{-2}\cdot\text{s}^{-1}, CC is molar concentration in mol⋅m−3\text{mol}\cdot\text{m}^{-3}, and xx is position in m\text{m}. Find the SI base units of the diffusion coefficient DD, and explain whether DD has the same base unit signature as kinematic viscosity ν\nu.

Answer

m2⋅s−1\text{m}^2\cdot\text{s}^{-1}; yes, they share the identical base unit signature. Key steps: [dCdx]=mol⋅m−3m=mol⋅m−4\left[\frac{dC}{dx}\right] = \frac{\text{mol}\cdot\text{m}^{-3}}{\text{m}} = \text{mol}\cdot\text{m}^{-4}. Then [D]=[J][dC/dx]=mol⋅m−2⋅s−1mol⋅m−4=m2⋅s−1[D] = \frac{[J]}{[dC/dx]} = \frac{\text{mol}\cdot\text{m}^{-2}\cdot\text{s}^{-1}}{\text{mol}\cdot\text{m}^{-4}} = \text{m}^2\cdot\text{s}^{-1}, matching [ν][\nu].

Loading workspace…