Resources

A pumped-storage hydroelectric facility transfers water from an upper reservoir situated at a vertical height of h=160 mh = 160\text{ m} above the powerhouse to drive a set of Francis turbines connected to electrical generators. Water flows through the penstock at a steady volumetric flow rate of Q=45.0 m3/sQ = 45.0\text{ m}^3/\text{s}. If the frictional and turbulent head losses in the penstock dissipate 12.0%12.0\% of the gross gravitational potential energy into thermal internal energy, and the combined electromechanical efficiency of the turbine-generator units is η=88.0%\eta = 88.0\%, identify the sequential stages of the energy-conversion chain and calculate the net electrical power output PelecP_{\text{elec}} delivered to the high-voltage transmission grid. Use ρwater=1.00×103 kg/m3\rho_{\text{water}} = 1.00 \times 10^3\text{ kg/m}^3 and g=9.80 m/s2g = 9.80\text{ m/s}^2.

Answer and steps

Final answer

Energy chain: Gravitational Potential Energy →\rightarrow Mechanical Kinetic Energy of fluid →\rightarrow Rotational Kinetic Energy of turbine/generator shaft →\rightarrow Electrical Energy (with parallel dissipative thermal losses at each transition); Pelec=5.46×107 WP_{\text{elec}} = 5.46 \times 10^7\text{ W} (or 54.6 MW54.6\text{ MW}).

Steps

01

Identify the Energy-Conversion Chain

Hydroelectric generation converts the potential energy of elevated water into electricity through a continuous sequence of energy transformations:

  1. Gravitational Potential Energy (EpE_{\text{p}}): Stored in the mass of water residing in the elevated reservoir at height hh.
  2. Kinetic Energy of Fluid Flow (Ek, fluidE_{\text{k, fluid}}): As water descends through the penstock, gravitational potential energy converts into kinetic and pressure energy of the moving fluid. Frictional and viscous shear forces dissipate a fraction of this energy into internal thermal energy.
  3. Rotational Kinetic Energy (Ek, rotE_{\text{k, rot}}): The high-speed water jet strikes the blades of the Francis turbine, transferring fluid momentum to the runner and turning the turbine-generator shaft.
  4. Electrical Energy (EelecE_{\text{elec}}): The rotating generator rotor drives electromagnetic induction in the stator windings, generating electrical power. Losses due to mechanical friction, windage, electrical resistance (Joule heating), and magnetic hysteresis release additional thermal energy.

Thus, the primary conversion sequence is: Gravitational Potential Energy⟶Fluid Kinetic/Flow Energy⟶Rotational Kinetic Energy⟶Electrical Energy\text{Gravitational Potential Energy} \longrightarrow \text{Fluid Kinetic/Flow Energy} \longrightarrow \text{Rotational Kinetic Energy} \longrightarrow \text{Electrical Energy} (with thermal dissipation occurring at each transition stage).


02

Calculate the Gross Power Input

The mass flow rate m˙\dot{m} of water entering the penstock is given by: m˙=ρwaterQ=(1.00×103 kg/m3)(45.0 m3/s)=4.50×104 kg/s\dot{m} = \rho_{\text{water}} Q = (1.00 \times 10^3\text{ kg/m}^3)(45.0\text{ m}^3/\text{s}) = 4.50 \times 10^4\text{ kg/s}

The gross theoretical gravitational potential power available per unit time is: Pgross=m˙ghP_{\text{gross}} = \dot{m} g h

Substituting the given values: Pgross=(4.50×104 kg/s)(9.80 m/s2)(160 m)=7.056×107 W=70.56 MWP_{\text{gross}} = (4.50 \times 10^4\text{ kg/s})(9.80\text{ m/s}^2)(160\text{ m}) = 7.056 \times 10^7\text{ W} = 70.56\text{ MW}


03

Account for Penstock Head Losses and Conversion Efficiency

  1. Penstock Efficiency (ηpenstock\eta_{\text{penstock}}):
    Frictional and turbulent dissipation consumes 12.0%12.0\% of the initial potential energy: ηpenstock=1−0.120=0.880\eta_{\text{penstock}} = 1 - 0.120 = 0.880 The hydraulic power delivered to the turbine inlet is: Phydraulic=Pgross×ηpenstock=70.56 MW×0.880=62.0928 MWP_{\text{hydraulic}} = P_{\text{gross}} \times \eta_{\text{penstock}} = 70.56\text{ MW} \times 0.880 = 62.0928\text{ MW}
  2. Combined Electromechanical Efficiency (η\eta):
    The turbine and generator units convert the available hydraulic power with an efficiency of η=88.0%=0.880\eta = 88.0\% = 0.880: Pelec=Phydraulic×ηP_{\text{elec}} = P_{\text{hydraulic}} \times \eta

Common Pitfall: Efficiencies at sequential stages multiply rather than subtract or add. The total overall efficiency is ηtotal=ηpenstock×η=0.880×0.880=0.7744\eta_{\text{total}} = \eta_{\text{penstock}} \times \eta = 0.880 \times 0.880 = 0.7744 (or 77.44%77.44\%).


04

Compute the Net Electrical Power Output

Combining the steps into a single expression: Pelec=Pgross×ηpenstock×ηP_{\text{elec}} = P_{\text{gross}} \times \eta_{\text{penstock}} \times \eta Pelec=(7.056×107 W)×0.880×0.880≈5.464×107 WP_{\text{elec}} = (7.056 \times 10^7\text{ W}) \times 0.880 \times 0.880 \approx 5.464 \times 10^7\text{ W}

Rounding to three significant figures to match the given data: Pelec=5.46×107 W(or 54.6 MW)P_{\text{elec}} = 5.46 \times 10^7\text{ W} \quad (\text{or } 54.6\text{ MW})

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student treats the 12.0% penstock loss as an efficiency of 12.0% rather than subtracting the losses, resulting in a severely underestimated net power output.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Gravitational potential energy→Kinetic energy of water→Mechanical energy of turbine→Electrical energy\text{Gravitational potential energy} \rightarrow \text{Kinetic energy of water} \rightarrow \text{Mechanical energy of turbine} \rightarrow \text{Electrical energy}

  2. Step 2

    m˙=1000⋅45.0=45000 kg/s  ⟹  Pgross=45000⋅9.80⋅160=70560000 W=70.56 MW\dot{m} = 1000 \cdot 45.0 = 45000\text{ kg/s} \implies P_{\text{gross}} = 45000 \cdot 9.80 \cdot 160 = 70560000\text{ W} = 70.56\text{ MW}

  3. Step 3

    Pturb=70.56⋅0.120=8.4672 MWP_{\text{turb}} = 70.56 \cdot 0.120 = 8.4672\text{ MW}

    Correct

    Phydraulic=Pgross×(1−0.120)=70.56 MW×0.880=62.09 MWP_{\text{hydraulic}} = P_{\text{gross}} \times (1 - 0.120) = 70.56\text{ MW} \times 0.880 = 62.09\text{ MW}

    The penstock dissipates 12.0%12.0\% as thermal losses, meaning the useful hydraulic power delivered to the turbine is 100%−12.0%=88.0%100\% - 12.0\% = 88.0\% of the gross power, not 12.0%12.0\%.

  4. Step 4

    Pelec=8.4672⋅0.880=7.45 MWP_{\text{elec}} = 8.4672 \cdot 0.880 = 7.45\text{ MW}

    Correct

    Pelec=62.0928 MW×0.880≈54.6 MWP_{\text{elec}} = 62.0928\text{ MW} \times 0.880 \approx 54.6\text{ MW}

    Your electromechanical conversion step correctly used η=0.880\eta = 0.880, but it inherited the incorrect input power from the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You clearly outlined the physical stages of the hydroelectric energy-conversion sequence.

You correctly calculated the mass flow rate from the fluid density and volumetric flow rate.

You accurately determined the gross theoretical input power using Pgross=m˙ghP_{\text{gross}} = \dot{m}gh.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Loss percentage confused with transmission efficiency

You used the loss fraction 0.1200.120 as the transmission efficiency rather than subtracting it from 11.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing energy dissipation/loss percentages with transmission efficiency factors ( η=1−loss factor\,\eta = 1 - \text{loss factor}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Loss vs. Transmitted Efficiency
  • When a stage dissipates a fraction LL of input energy, the transmitted power is Pout=Pin(1−L)P_{\text{out}} = P_{\text{in}}(1 - L), while the lost power is Plost=PinLP_{\text{lost}} = P_{\text{in}}L.

  • Always check whether a percentage represents 'energy lost' or 'energy delivered', and subtract losses from 100%100\% before propagating forward.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Phydraulic=Pgross×(1−0.120)=70.56 MW×0.880=62.0928 MWP_{\text{hydraulic}} = P_{\text{gross}} \times (1 - 0.120) = 70.56\text{ MW} \times 0.880 = 62.0928\text{ MW}

  2. Pelec=Phydraulic×η=62.0928 MW×0.880=54.64 MWP_{\text{elec}} = P_{\text{hydraulic}} \times \eta = 62.0928\text{ MW} \times 0.880 = 54.64\text{ MW}

Final answer

Pelec=5.46×107 WP_{\text{elec}} = 5.46 \times 10^7\text{ W} (or 54.6 MW54.6\text{ MW})

NEXT STEPS
Final Takeaways from Your Teacher
  • In multi-stage systems, label each percentage explicitly as either a transmission efficiency η\eta or a dissipation fraction LL.

  • Perform a sanity check on intermediate values: a penstock with only minor friction losses should deliver most of the gross potential energy to the turbine runner.

OverviewACEpath Teacher's Diagnosis

02 The student forgets to account for the 12.0% penstock loss entirely and directly applies the generator efficiency to the gross power.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Gravitational potential energy→Kinetic energy→Mechanical rotational energy→Electrical energy\text{Gravitational potential energy} \rightarrow \text{Kinetic energy} \rightarrow \text{Mechanical rotational energy} \rightarrow \text{Electrical energy}

  2. Step 2

    Pgross=ρ⋅Q⋅g⋅h⟹Pgross=1000⋅45.0⋅9.80⋅160=70.56 MWP_{\text{gross}} = \rho \cdot Q \cdot g \cdot h \Longrightarrow P_{\text{gross}} = 1000 \cdot 45.0 \cdot 9.80 \cdot 160 = 70.56\text{ MW}

  3. Step 3

    Pelec=η⋅Pgross=0.880⋅70.56 MW=62.1 MWP_{\text{elec}} = \eta \cdot P_{\text{gross}} = 0.880 \cdot 70.56\text{ MW} = 62.1\text{ MW}

    Correct

    Pelec=Pgross×(1−0.120)×η=70.56 MW×0.880×0.880≈54.6 MWP_{\text{elec}} = P_{\text{gross}} \times (1 - 0.120) \times \eta = 70.56\text{ MW} \times 0.880 \times 0.880 \approx 54.6\text{ MW}

    You only accounted for the electromechanical efficiency of the turbine-generator (η=0.880\eta = 0.880) and omitted the 12.0%12.0\% friction loss in the penstock (ηpenstock=1−0.120=0.880\eta_{\text{penstock}} = 1 - 0.120 = 0.880). Both conversion stages must be compounded multiplicatively.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the full physical sequence of energy transformations from reservoir potential energy to electrical energy.

You calculated the gross input power accurately using Pgross=ρQghP_{\text{gross}} = \rho Q g h.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted multi-stage loss in energy chain

You applied only one factor of 0.8800.880 instead of accounting for both the penstock transmission loss and the electromechanical generator loss.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating a multi-stage energy system with losses at distinct points as having only one efficiency stage, rather than multiplying the sequential transmission efficiencies along the chain.

REASONING PATH
Your ACEpath teacher’s suggested approach
Compound Efficiencies Along an Energy Chain
  • When energy flows through consecutive stages with intermediate losses, overall efficiency is the product of all stage efficiencies: ηtotal=η1×η2×⋯×ηn\eta_{\text{total}} = \eta_1 \times \eta_2 \times \dots \times \eta_n.

  • Check every physical stage along your chain (penstock transport, turbine rotation, generator output) and multiply their respective efficiencies together before computing net power.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the penstock transmission efficiency: ηpenstock=1−0.120=0.880\eta_{\text{penstock}} = 1 - 0.120 = 0.880.

  2. Multiply gross power by both sequential efficiencies: Pelec=Pgross×ηpenstock×ηturbine-genP_{\text{elec}} = P_{\text{gross}} \times \eta_{\text{penstock}} \times \eta_{\text{turbine-gen}}.

  3. Substitute numerical values: Pelec=70.56 MW×0.880×0.880=54.64 MWP_{\text{elec}} = 70.56\text{ MW} \times 0.880 \times 0.880 = 54.64\text{ MW}.

Final answer

Pelec=5.46×107 WP_{\text{elec}} = 5.46 \times 10^7\text{ W} (or 54.6 MW54.6\text{ MW})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how energy flows through multi-stage systems and practice writing out an efficiency factor ηi\eta_i for every distinct transition.

  • Solve the practice problems below to master chaining transmission and conversion efficiencies.

OverviewACEpath Teacher's Diagnosis

03 The student adds the 12.0% loss to the efficiency or subtracts 12% directly from the 88% efficiency by confusing overall efficiency with additive percentages.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Gravitational potential energy →\rightarrow Kinetic energy of water →\rightarrow Mechanical energy →\rightarrow Electrical energy

  2. Step 2

    Pgross=1000⋅45.0⋅9.80⋅160=70.56 MWP_{\text{gross}} = 1000 \cdot 45.0 \cdot 9.80 \cdot 160 = 70.56\text{ MW}

  3. Step 3

    ηtotal=88.0%−12.0%=76.0%\eta_{\text{total}} = 88.0\% - 12.0\% = 76.0\%

    Correct

    ηpenstock=1−0.120=0.880  ⟹  ηtotal=ηpenstock×η=0.880×0.880=0.7744 (or 77.44%)\eta_{\text{penstock}} = 1 - 0.120 = 0.880 \implies \eta_{\text{total}} = \eta_{\text{penstock}} \times \eta = 0.880 \times 0.880 = 0.7744\text{ (or } 77.44\%)

    Efficiencies of consecutive stages in an energy chain multiply rather than subtract. The penstock retains 1−0.120=0.8801 - 0.120 = 0.880 of the power, and the turbine-generator converts 88.0%88.0\% of that remaining hydraulic power, giving ηtotal=0.880×0.880=0.7744\eta_{\text{total}} = 0.880 \times 0.880 = 0.7744.

  4. Step 4

    Pelec=70.56⋅0.760=53.6 MWP_{\text{elec}} = 70.56 \cdot 0.760 = 53.6\text{ MW}

    Correct

    Pelec=Pgross×ηtotal=70.56 MW×0.7744≈54.6 MWP_{\text{elec}} = P_{\text{gross}} \times \eta_{\text{total}} = 70.56\text{ MW} \times 0.7744 \approx 54.6\text{ MW}

    Your calculation carried forward the incorrect overall efficiency from the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the full energy-conversion chain from gravitational potential energy to electrical energy.

You accurately determined the mass flow rate and gross gravitational power.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Additive Efficiency Fallacy

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated percentage loss and stage efficiency as additive quantities across different stages rather than recognizing that each sequential conversion stage operates only on the energy output delivered by the preceding stage.

REASONING PATH
Your ACEpath teacher’s suggested approach
Multistage Efficiency Rule
  • For sequential conversion processes, ηtotal=η1×η2×⋯×ηn\eta_{\text{total}} = \eta_1 \times \eta_2 \times \dots \times \eta_n.

  • Always convert each stage's transmission or conversion rate to a fractional efficiency first, then multiply them together.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Find penstock transmission efficiency: ηpenstock=1.000−0.120=0.880\eta_{\text{penstock}} = 1.000 - 0.120 = 0.880.

  2. Multiply sequential efficiencies: ηtotal=ηpenstock×ηgen=0.880×0.880=0.7744\eta_{\text{total}} = \eta_{\text{penstock}} \times \eta_{\text{gen}} = 0.880 \times 0.880 = 0.7744.

  3. Compute net power: Pelec=Pgross×ηtotal=70.56 MW×0.7744≈54.6 MWP_{\text{elec}} = P_{\text{gross}} \times \eta_{\text{total}} = 70.56\text{ MW} \times 0.7744 \approx 54.6\text{ MW}.

Final answer

5.46×107 W (or 54.6 MW)5.46 \times 10^7\text{ W}\text{ (or } 54.6\text{ MW})

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice combining multistage efficiencies by multiplying successive decimal fractions rather than combining percentage points.

  • Review Sankey diagrams to visualize how energy decreases sequentially along each stage of a power system.

Lock it in

Similar question

01

A water turbine receives hydraulic power of Pin=25.0 MWP_{\text{in}} = 25.0\text{ MW}. Mechanical friction in the bearings dissipates 4.0%4.0\% of this power, and the attached generator has an electrical efficiency of 92.0%92.0\%. Calculate the net electrical power produced.

Answer

Pmech=25.0 MW×(1−0.040)=24.0 MWP_{\text{mech}} = 25.0\text{ MW} \times (1 - 0.040) = 24.0\text{ MW}. Then Pelec=24.0 MW×0.920=22.08 MW≈22.1 MWP_{\text{elec}} = 24.0\text{ MW} \times 0.920 = 22.08\text{ MW} \approx 22.1\text{ MW}.

02

An elevated water tower delivers water at a mass flow rate of 150 kg/s150\text{ kg/s} over an effective drop of h=40.0 mh = 40.0\text{ m}. Viscous pipe friction consumes 8.0%8.0\% of the gross gravitational energy. What is the hydraulic power available at the nozzle exit? (Use g=9.80 m/s2g = 9.80\text{ m/s}^2.)

Answer

Pgross=m˙gh=(150)(9.80)(40.0)=58.8 kWP_{\text{gross}} = \dot{m}gh = (150)(9.80)(40.0) = 58.8\text{ kW}. Accounting for losses: Pnet=58.8 kW×(1−0.080)=54.096 kW≈54.1 kWP_{\text{net}} = 58.8\text{ kW} \times (1 - 0.080) = 54.096\text{ kW} \approx 54.1\text{ kW}.

03

A pumped-storage system has three sequential stages: penstock fluid transport (dissipates 10.0%10.0\% as heat), turbine runner conversion (efficiency η1=90.0%\eta_1 = 90.0\%), and generator induction (dissipates 5.0%5.0\% as electrical resistance heat). Calculate the overall system efficiency ηtotal\eta_{\text{total}}.

Answer

Each stage efficiency is ηpen=1−0.100=0.900\eta_{\text{pen}} = 1 - 0.100 = 0.900, ηturb=0.900\eta_{\text{turb}} = 0.900, and ηgen=1−0.050=0.950\eta_{\text{gen}} = 1 - 0.050 = 0.950. Overall efficiency is ηtotal=0.900×0.900×0.950=0.7695=76.95%\eta_{\text{total}} = 0.900 \times 0.900 \times 0.950 = 0.7695 = 76.95\%.

Loading workspace…