A microfluidic cooling device dissipates thermal energy at a rate of q=145 mW/mm2q = 145\text{ mW/mm}^2. Convert this heat flux into standard engineering units of kilowatts per square meter (kW/m2\text{kW/m}^2) and into imperial units of British thermal units per hour per square foot (Btu/(h⋅ft2)\text{Btu/(h}\cdot\text{ft}^2\text{)}), using 1 W=3.412 Btu/h1\text{ W} = 3.412\text{ Btu/h} and 1 m=3.281 ft1\text{ m} = 3.281\text{ ft}. Express both values to three significant figures.

Answer and steps

Final answer

145 kW/m2145\text{ kW/m}^2 and 4.60×104 Btu/(h⋅ft2)4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2\text{)}

Steps

01

Convert to Kilowatts per Square Meter (kW/m2\text{kW/m}^2)

Write down the metric prefix relationships for both power and length:

  • For power: 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W} and 1 kW=103 W1\text{ kW} = 10^3\text{ W}, which means: 1 mW=10−6 kW1\text{ mW} = 10^{-6}\text{ kW}
  • For area: 1 mm=10−3 m1\text{ mm} = 10^{-3}\text{ m}. Squaring both sides gives: 1 mm2=(10−3 m)2=10−6 m21\text{ mm}^2 = (10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2

Substitute these conversions into the given heat flux: q=145 mW/mm2=145×10−6 kW10−6 m2=145 kW/m2q = 145\text{ mW/mm}^2 = 145 \times \frac{10^{-6}\text{ kW}}{10^{-6}\text{ m}^2} = 145\text{ kW/m}^2

Expressed to three significant figures, this is 145 kW/m2145\text{ kW/m}^2.


02

Convert to Imperial Units (Btu/(h⋅ft2)\text{Btu/(h}\cdot\text{ft}^2\text{)})

Express 145 kW/m2145\text{ kW/m}^2 in base SI units: 145 kW/m2=1.45×105 W/m2145\text{ kW/m}^2 = 1.45 \times 10^5\text{ W/m}^2

Now, apply the given conversion factors using dimensional analysis:

  • Power: 1 W=3.412 Btu/h1\text{ W} = 3.412\text{ Btu/h}
  • Area: 1 m=3.281 ft  ⟹  1 m2=(3.281 ft)2≈10.765 ft21\text{ m} = 3.281\text{ ft} \implies 1\text{ m}^2 = (3.281\text{ ft})^2 \approx 10.765\text{ ft}^2

Common Pitfall: When converting units of area, you must square the linear conversion factor (i.e., (3.281 ft)2(3.281\text{ ft})^2, not simply 3.281 ft23.281\text{ ft}^2).

Set up the conversion chain: q=(1.45×105 Wm2)×(3.412 Btu/h1 W)×(1 m3.281 ft)2q = \left(1.45 \times 10^5\text{ }\frac{\text{W}}{\text{m}^2}\right) \times \left(\frac{3.412\text{ Btu/h}}{1\text{ W}}\right) \times \left(\frac{1\text{ m}}{3.281\text{ ft}}\right)^2

Calculate the intermediate values: q=1.45×105⋅3.412(3.281)2 Btu/(h⋅ft2)=49474010.76496 Btu/(h⋅ft2)≈45958 Btu/(h⋅ft2)q = \frac{1.45 \times 10^5 \cdot 3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) = \frac{494740}{10.76496}\text{ Btu/(h}\cdot\text{ft}^2) \approx 45958\text{ Btu/(h}\cdot\text{ft}^2)

Rounding to three significant figures yields: q=4.60×104 Btu/(h⋅ft2)q = 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the linear conversion factor when converting square millimeters to square meters, underestimating the area factor by 10³.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    1 mW=10−3 W  ⟹  1 mm2=10−3 m21\text{ mW} = 10^{-3}\text{ W} \implies 1\text{ mm}^2 = 10^{-3}\text{ m}^2

    Correct

    1 mW=10−3 W  ⟹  1 mm2=(10−3 m)2=10−6 m21\text{ mW} = 10^{-3}\text{ W} \implies 1\text{ mm}^2 = (10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2

    You correctly stated that 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W}, but for area you wrote 1 mm2=10−3 m21\text{ mm}^2 = 10^{-3}\text{ m}^2. Because 1 mm=10−3 m1\text{ mm} = 10^{-3}\text{ m}, squaring both sides gives (1 mm)2=(10−3 m)2=10−6 m2(1\text{ mm})^2 = (10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2.

  2. Step 2

    q=145×10−3 W10−3 m2=145 W/m2  ⟹  145 W/m2=0.145 kW/m2q = \frac{145 \times 10^{-3}\text{ W}}{10^{-3}\text{ m}^2} = 145\text{ W/m}^2 \implies 145\text{ W/m}^2 = 0.145\text{ kW/m}^2

    Correct

    q=145×10−3 W10−6 m2=1.45×105 W/m2=145 kW/m2q = \frac{145 \times 10^{-3}\text{ W}}{10^{-6}\text{ m}^2} = 1.45 \times 10^5\text{ W/m}^2 = 145\text{ kW/m}^2

    Because of the area conversion error in Step 1, you obtained 145 W/m2145\text{ W/m}^2 instead of 1.45×105 W/m21.45 \times 10^5\text{ W/m}^2, which then led to 0.145 kW/m20.145\text{ kW/m}^2 instead of 145 kW/m2145\text{ kW/m}^2.

  3. Step 3

    q=145×3.412(3.281)2 Btu/(h⋅ft2)  ⟹  q=494.7410.765=46.0 Btu/(h⋅ft2)q = \frac{145 \times 3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) \implies q = \frac{494.74}{10.765} = 46.0\text{ Btu/(h}\cdot\text{ft}^2)

    Correct

    q=(1.45×105)×3.412(3.281)2 Btu/(h⋅ft2)≈4.60×104 Btu/(h⋅ft2)q = \frac{(1.45 \times 10^5) \times 3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) \approx 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

    You correctly squared (3.281 ft)2(3.281\text{ ft})^2 in the denominator and applied the power conversion factor, but you carried over the underestimated base value 145 W/m2145\text{ W/m}^2 rather than 1.45×105 W/m21.45 \times 10^5\text{ W/m}^2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the metric prefix for milliwatts as 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W}.

You remembered to square the linear conversion factor (3.281 ft)2(3.281\text{ ft})^2 when converting square meters to square feet.

You carried out the dimensional analysis arithmetic with correct significant figures.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unsquared linear prefix in area conversion

You treated the area unit mm2\text{mm}^2 as having the same conversion factor as the linear unit mm\text{mm}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing linear dimension conversion with derived area conversion. When converting squared or cubed units, the entire conversion factor (including prefix powers of 10) must be raised to that same power.

REASONING PATH
Your ACEpath teacher’s suggested approach
Square the Entire Factor for Area
  • For any linear conversion 1 unitA=k unitB1\text{ unit}_A = k\text{ unit}_B, the area conversion is 1 unitA2=k2 unitB21\text{ unit}_A^2 = k^2\text{ unit}_B^2.

  • Always write out parentheses around both the coefficient and the unit before squaring, such as (10−3 m)2=10−6 m2(10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the area conversion by squaring the linear relation: 1 mm=10−3 m  ⟹  1 mm2=(10−3 m)2=10−6 m21\text{ mm} = 10^{-3}\text{ m} \implies 1\text{ mm}^2 = (10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2.

  2. Substitute into heat flux: q=145 mW/mm2=145×10−3 W10−6 m2=1.45×105 W/m2q = 145\text{ mW/mm}^2 = 145 \times \frac{10^{-3}\text{ W}}{10^{-6}\text{ m}^2} = 1.45 \times 10^5\text{ W/m}^2.

  3. Convert to kilowatts per square meter: 1.45×105 W/m2=145 kW/m21.45 \times 10^5\text{ W/m}^2 = 145\text{ kW/m}^2.

  4. Convert to imperial units using (3.281 ft)2(3.281\text{ ft})^2: q=(1.45×105)(3.412)(3.281)2≈45958 Btu/(h⋅ft2)=4.60×104 Btu/(h⋅ft2)q = \frac{(1.45 \times 10^5)(3.412)}{(3.281)^2} \approx 45958\text{ Btu/(h}\cdot\text{ft}^2) = 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2).

Final answer

145 kW/m2145\text{ kW/m}^2 and 4.60×104 Btu/(h⋅ft2)4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting derived units of area and volume by explicitly squaring or cubing the base conversion factor.

  • Double-check that metric prefixes attached to squared units like cm2\text{cm}^2 or mm2\text{mm}^2 are squared along with the unit.

OverviewACEpath Teacher's Diagnosis

02 The student forgets to square the length conversion factor when converting square meters to square feet in imperial units.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    q=145×10−3 W/(10−3 m)2  ⟹  q=145000 W/m2  ⟹  q=145 kW/m2q = 145 \times 10^{-3}\text{ W} / (10^{-3}\text{ m})^2 \implies q = 145000\text{ W/m}^2 \implies q = 145\text{ kW/m}^2

  2. Step 2

    145 kW/m2=145000 W/m2  ⟹  q=145000×3.4123.281 Btu/(h⋅ft2)145\text{ kW/m}^2 = 145000\text{ W/m}^2 \implies q = 145000 \times \frac{3.412}{3.281}\text{ Btu/(h}\cdot\text{ft}^2)

    Correct

    q=145000 W/m2×(3.412 Btu/h1 W)×(1 m3.281 ft)2q = 145000\text{ W/m}^2 \times \left(\frac{3.412\text{ Btu/h}}{1\text{ W}}\right) \times \left(\frac{1\text{ m}}{3.281\text{ ft}}\right)^2

    You applied the conversion factor 1 m=3.281 ft1\text{ m} = 3.281\text{ ft} as a linear factor instead of squaring it to convert square meters into square feet: 1 m2=(3.281 ft)2≈10.765 ft21\text{ m}^2 = (3.281\text{ ft})^2 \approx 10.765\text{ ft}^2.

  3. Step 3

    q=4947403.281=1.51×105 Btu/(h⋅ft2)q = \frac{494740}{3.281} = 1.51 \times 10^5\text{ Btu/(h}\cdot\text{ft}^2)

    Correct

    q=494740(3.281)2≈4.60×104 Btu/(h⋅ft2)q = \frac{494740}{(3.281)^2} \approx 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

    Your arithmetic evaluation followed directly from the unsquared denominator in Step 2, leading to an answer that is a factor of 3.2813.281 too large.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly squared the millimeter-to-meter conversion factor when converting the metric units.

You correctly multiplied by the power conversion ratio 3.412 (Btu/h)/W3.412\text{ (Btu/h)/W}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unsquared Area Conversion Factor

You divided by the linear ratio 3.2813.281 rather than squaring the entire ratio (3.281 ft/m)2(3.281\text{ ft/m})^2.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

When converting derived units involving area or volume, conversion factors between base length units must be raised to the same power (squared for area, cubed for volume) to maintain dimensional consistency.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional Powers of Units
  • If [L1]=c[L2][L_1] = c[L_2], then [A1]=[L1]2=c2[L2]2[A_1] = [L_1]^2 = c^2[L_2]^2.

  • Always write conversion factors with parentheses and apply the exponent to both the numerical value and the unit symbol before evaluating.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Express the conversion with the squared length ratio: q=1.45×105 W/m2×3.412 Btu/(h⋅W)1×(1 m3.281 ft)2q = 1.45 \times 10^5\text{ W/m}^2 \times \frac{3.412\text{ Btu/(h}\cdot\text{W)}}{1} \times \left(\frac{1\text{ m}}{3.281\text{ ft}}\right)^2

  2. Evaluate the squared denominator: (3.281)2≈10.765 ft2(3.281)^2 \approx 10.765\text{ ft}^2

  3. Compute the quotient: q=49474010.765≈45958 Btu/(h⋅ft2)q = \frac{494740}{10.765} \approx 45958\text{ Btu/(h}\cdot\text{ft}^2)

  4. Round to three significant figures: q=4.60×104 Btu/(h⋅ft2)q = 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

Final answer

145 kW/m2145\text{ kW/m}^2 and 4.60×104 Btu/(h⋅ft2)4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out full dimensional analysis parentheses around unit factors, such as (1 m3.281 ft)2\left(\frac{1\text{ m}}{3.281\text{ ft}}\right)^2, to remind yourself to square both the number and the unit.

  • Perform a sanity check on unit magnitude: 1 m21\text{ m}^2 is about 10.8 ft210.8\text{ ft}^2, so spreading heat over a square meter should be roughly 10 times more spread out than over a square foot.

OverviewACEpath Teacher's Diagnosis

03 The student treats the prefix milli as 10⁻⁶ instead of 10⁻³, mistaking milliwatts for microwatts.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    1 mW=10−6 W1\text{ mW} = 10^{-6}\text{ W}

    Correct

    1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W}

    You initially had the correct conversion 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W} written down, but crossed it out and changed it to 10−6 W10^{-6}\text{ W}. The prefix milli- (m\text{m}) corresponds to 10−310^{-3}, whereas micro- (μ\mu) corresponds to 10−610^{-6}.

  2. Step 2

    1 mm2=10−6 m2  ⟹  q=145×10−6 W10−6 m2=145 W/m2  ⟹  q=0.145 kW/m21\text{ mm}^2 = 10^{-6}\text{ m}^2 \implies q = \frac{145 \times 10^{-6}\text{ W}}{10^{-6}\text{ m}^2} = 145\text{ W/m}^2 \implies q = 0.145\text{ kW/m}^2

    Correct

    q=145×10−3 W10−6 m2=1.45×105 W/m2=145 kW/m2q = \frac{145 \times 10^{-3}\text{ W}}{10^{-6}\text{ m}^2} = 1.45 \times 10^5\text{ W/m}^2 = 145\text{ kW/m}^2

    Your area conversion 1 mm2=10−6 m21\text{ mm}^2 = 10^{-6}\text{ m}^2 and your division by 10310^3 to go from W\text{W} to kW\text{kW} were both algebraically sound, but substituting 10−6 W10^{-6}\text{ W} instead of 10−3 W10^{-3}\text{ W} caused the powers of ten to cancel prematurely.

  3. Step 3

    q=145×3.412(3.281)2 Btu/(h⋅ft2)  ⟹  q=494.7410.765=46.0 Btu/(h⋅ft2)q = \frac{145 \times 3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) \implies q = \frac{494.74}{10.765} = 46.0\text{ Btu/(h}\cdot\text{ft}^2)

    Correct

    q=1.45×105×3.412(3.281)2 Btu/(h⋅ft2)≈4.60×104 Btu/(h⋅ft2)q = \frac{1.45 \times 10^5 \times 3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) \approx 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

    You correctly set up the imperial conversion factors including squaring 3.281 ft/m3.281\text{ ft/m}, but using your intermediate value of 145 W/m2145\text{ W/m}^2 instead of 1.45×105 W/m21.45 \times 10^5\text{ W/m}^2 caused your result to be smaller by a factor of 10310^3.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated that 1 mm2=10−6 m21\text{ mm}^2 = 10^{-6}\text{ m}^2 by squaring the linear metric conversion factor.

You correctly squared the conversion factor 3.281 ft/m3.281\text{ ft/m} when converting area to square feet.

You executed all arithmetic computations cleanly and maintained correct significant figures.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric prefix confusion (milli vs. micro)

You crossed out the correct relation 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W} and replaced it with 1 mW=10−6 W1\text{ mW} = 10^{-6}\text{ W}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the metric prefix milli- (m−\text{m}-, representing 10−310^{-3}) with micro- (μ−\mu-, representing 10−610^{-6}), which propagated an error of 10310^3 into both final calculations.

REASONING PATH
Your ACEpath teacher’s suggested approach
Metric Prefix Powers of Ten
  • The prefix milli- (m\text{m}) always denotes 10−310^{-3}, while micro- (μ\mu) denotes 10−610^{-6}.

  • Verify prefix symbols before writing: m→10−3\text{m} \to 10^{-3} and μ→10−6\mu \to 10^{-6}.

Order-of-Magnitude Sanity Check
  • There are 106 mm210^6\text{ mm}^2 in 1 m21\text{ m}^2, so heat flux concentrated into square millimeters scales up dramatically per square meter.

  • Check that 145 mW/mm2=145×10−3 W/10−6 m2=145×103 W/m2=145 kW/m2145\text{ mW/mm}^2 = 145 \times 10^{-3}\text{ W} / 10^{-6}\text{ m}^2 = 145 \times 10^3\text{ W/m}^2 = 145\text{ kW/m}^2.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the correct prefix conversion: 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W}.

  2. Convert heat flux to base SI units: q=145×10−3 W10−6 m2=1.45×105 W/m2q = \frac{145 \times 10^{-3}\text{ W}}{10^{-6}\text{ m}^2} = 1.45 \times 10^5\text{ W/m}^2.

  3. Convert to kW/m2\text{kW/m}^2: 1.45×105 W/m2×1 kW103 W=145 kW/m21.45 \times 10^5\text{ W/m}^2 \times \frac{1\text{ kW}}{10^3\text{ W}} = 145\text{ kW/m}^2.

  4. Convert to imperial units using (3.281 ft)2(3.281\text{ ft})^2: q=(1.45×105)×3.412(3.281)2 Btu/(h⋅ft2)≈4.60×104 Btu/(h⋅ft2)q = \left(1.45 \times 10^5\right) \times \frac{3.412}{(3.281)^2}\text{ Btu/(h}\cdot\text{ft}^2) \approx 4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2).

Final answer

145 kW/m2145\text{ kW/m}^2 and 4.60×104 Btu/(h⋅ft2)4.60 \times 10^4\text{ Btu/(h}\cdot\text{ft}^2)

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the SI prefix ladder from kilo (10310^3) down to nano (10−910^{-9}), focusing on the distinction between milli (10−310^{-3}) and micro (10−610^{-6}).

  • Practice checking whether a physical density or flux should increase or decrease when changing from small area units (extmm2 ext{mm}^2) to large area units (extm2 ext{m}^2).

Lock it in

Similar question

01

A laser diode outputs a power density of 25 mW/cm225\text{ mW/cm}^2. Convert this value to W/m2\text{W/m}^2.

Answer

250 W/m2250\text{ W/m}^2. Key steps: 1 mW=10−3 W1\text{ mW} = 10^{-3}\text{ W} and 1 cm2=(10−2 m)2=10−4 m21\text{ cm}^2 = (10^{-2}\text{ m})^2 = 10^{-4}\text{ m}^2. Thus, 25×10−3 W10−4 m2=25×10=250 W/m225 \times \frac{10^{-3}\text{ W}}{10^{-4}\text{ m}^2} = 25 \times 10 = 250\text{ W/m}^2.

02

A hydraulic piston exerts a pressure of 8.5 N/mm28.5\text{ N/mm}^2. Convert this pressure into megapascals (MPa\text{MPa}), where 1 Pa=1 N/m21\text{ Pa} = 1\text{ N/m}^2 and 1 MPa=106 Pa1\text{ MPa} = 10^6\text{ Pa}.

Answer

8.5 MPa8.5\text{ MPa}. Key steps: 1 mm2=(10−3 m)2=10−6 m21\text{ mm}^2 = (10^{-3}\text{ m})^2 = 10^{-6}\text{ m}^2. Pressure in pascals is 8.5 N10−6 m2=8.5×106 Pa=8.5 MPa\frac{8.5\text{ N}}{10^{-6}\text{ m}^2} = 8.5 \times 10^6\text{ Pa} = 8.5\text{ MPa}.

03

An engine dissipates heat at a volumetric rate of 4.2 W/cm34.2\text{ W/cm}^3. Convert this heat generation rate into kilowatts per cubic meter (kW/m3\text{kW/m}^3).

Answer

4.2×103 kW/m34.2 \times 10^3\text{ kW/m}^3. Key steps: 1 cm3=(10−2 m)3=10−6 m31\text{ cm}^3 = (10^{-2}\text{ m})^3 = 10^{-6}\text{ m}^3. Therefore, 4.2 W/cm3=4.2 W10−6 m3=4.2×106 W/m3=4.2×103 kW/m34.2\text{ W/cm}^3 = \frac{4.2\text{ W}}{10^{-6}\text{ m}^3} = 4.2 \times 10^6\text{ W/m}^3 = 4.2 \times 10^3\text{ kW/m}^3.