Resources

A laboratory pipe manifold consists of an inlet branch (Branch 1) with an inner diameter of d1=6.00 cmd_1 = 6.00\text{ cm} carrying an inflow of v1=2.40 m/sv_1 = 2.40\text{ m/s}. At a junction, it splits into two identical delivery branches (Branch 2 and Branch 3), each having an inner diameter of d2=d3=3.00 cmd_2 = d_3 = 3.00\text{ cm}. Adopting the standard net-flux convention where outward volumetric flux is defined as positive (+Q+Q) and inward volumetric flux is defined as negative (−Q-Q), state the algebraic continuity equation at the node, and compute the signed flux Q1Q_1 of the inlet branch and the resulting discharge speed v2v_2 in each branch assuming equal division of flow.

Answer and steps

Final answer

∑Qnode=−Q1+Q2+Q3=0\sum Q_{\text{node}} = -Q_1 + Q_2 + Q_3 = 0, signed inlet flux Q1=−6.79×10−3 m3/sQ_1 = -6.79 \times 10^{-3}\text{ m}^3\text{/s}, exit speed v2=v3=4.80 m/sv_2 = v_3 = 4.80\text{ m/s}

Steps

01

Algebraic Continuity Equation at the Node

For an incompressible fluid, mass conservation requires that the total volume of fluid entering a junction per unit time equals the total volume of fluid leaving it.

Under the net-flux convention:

  • Outward fluxes (leaving the control volume) are taken as positive (+Q+Q).
  • Inward fluxes (entering the control volume) are taken as negative (−Q-Q).

Expressing the sum of volumetric fluxes across the junction node gives: ∑Qnode=−Q1+Q2+Q3=0\sum Q_{\text{node}} = -Q_1 + Q_2 + Q_3 = 0

Equivalently, the sum of all signed fluxes entering and leaving the node vanishes: Qinlet, signed+Q2+Q3=0Q_{\text{inlet, signed}} + Q_2 + Q_3 = 0


02

Cross-Sectional Area and Signed Flux of the Inlet Branch

The cross-sectional area of the inlet pipe of diameter d1=6.00 cm=0.0600 md_1 = 6.00\text{ cm} = 0.0600\text{ m} is: A1=πd124=π(0.0600 m)24≈2.827×10−3 m2A_1 = \frac{\pi d_1^2}{4} = \frac{\pi (0.0600\text{ m})^2}{4} \approx 2.827 \times 10^{-3}\text{ m}^2

The magnitude of the incoming volumetric flow rate is: ∣Q1∣=A1v1=(2.827×10−3 m2)(2.40 m/s)≈6.79×10−3 m3/s|Q_1| = A_1 v_1 = (2.827 \times 10^{-3}\text{ m}^2)(2.40\text{ m/s}) \approx 6.79 \times 10^{-3}\text{ m}^3\text{/s}

Applying the sign convention (negative for an inflow): Q1=−6.79×10−3 m3/sQ_1 = -6.79 \times 10^{-3}\text{ m}^3\text{/s}


03

Discharge Speed in the Delivery Branches

Because the two branches are identical and share the total inflow equally: Q2=Q3=∣Q1∣2=6.786×10−3 m3/s2≈3.393×10−3 m3/sQ_2 = Q_3 = \frac{|Q_1|}{2} = \frac{6.786 \times 10^{-3}\text{ m}^3\text{/s}}{2} \approx 3.393 \times 10^{-3}\text{ m}^3\text{/s}

The cross-sectional area of each exit pipe with diameter d2=3.00 cm=0.0300 md_2 = 3.00\text{ cm} = 0.0300\text{ m} is: A2=πd224=π(0.0300 m)24≈7.069×10−4 m2A_2 = \frac{\pi d_2^2}{4} = \frac{\pi (0.0300\text{ m})^2}{4} \approx 7.069 \times 10^{-4}\text{ m}^2

The exit flow speed v2v_2 is: v2=Q2A2=3.393×10−3 m3/s7.069×10−4 m2=4.80 m/sv_2 = \frac{Q_2}{A_2} = \frac{3.393 \times 10^{-3}\text{ m}^3\text{/s}}{7.069 \times 10^{-4}\text{ m}^2} = 4.80\text{ m/s}

Alternative scaling check: Since A∝d2A \propto d^2, halving the diameter reduces the area by a factor of 22=42^2 = 4. With the total flow rate split by 22 across two branches: v2=12A1v1A2=12(d1d2)2v1=12(2)2(2.40 m/s)=2(2.40 m/s)=4.80 m/sv_2 = \frac{\frac{1}{2} A_1 v_1}{A_2} = \frac{1}{2}\left(\frac{d_1}{d_2}\right)^2 v_1 = \frac{1}{2}(2)^2 (2.40\text{ m/s}) = 2(2.40\text{ m/s}) = 4.80\text{ m/s} Both exit branches carry equal discharge speeds: v2=v3=4.80 m/sv_2 = v_3 = 4.80\text{ m/s}.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student ignores the specified sign convention defining inward flow as negative and writes the inlet flux as positive.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Q1+Q2+Q3=0Q_1 + Q_2 + Q_3 = 0

    Correct

    −Q1+Q2+Q3=0-Q_1 + Q_2 + Q_3 = 0

    You wrote all terms with positive signs. Under the standard control-volume net-flux convention, outward fluxes are positive (+Q+Q) and inward fluxes are negative (−Q-Q). Because Branch 1 is an inlet, its term enters with a negative sign.

  2. Step 2

    A1=π(0.0300 m)2=2.827×10−3 m2  ⟹  Q1=A1v1=(2.827×10−3 m2)(2.40 m/s)=+6.79×10−3 m3/sA_1 = \pi (0.0300\text{ m})^2 = 2.827 \times 10^{-3}\text{ m}^2 \implies Q_1 = A_1 v_1 = (2.827 \times 10^{-3}\text{ m}^2)(2.40\text{ m/s}) = +6.79 \times 10^{-3}\text{ m}^3/\text{s}

    Correct

    A1=πd124≈2.827×10−3 m2  ⟹  Q1=−A1v1=−6.79×10−3 m3/sA_1 = \frac{\pi d_1^2}{4} \approx 2.827 \times 10^{-3}\text{ m}^2 \implies Q_1 = -A_1 v_1 = -6.79 \times 10^{-3}\text{ m}^3/\text{s}

    You calculated the magnitude of the inlet volumetric flow rate accurately, but you assigned it a positive sign (+6.79×10−3 m3/s+6.79 \times 10^{-3}\text{ m}^3/\text{s}) instead of a negative sign for inflow.

  3. Step 3

    Q2=Q12=3.39×10−3 m3/s  ⟹  A2=π(0.0150 m)2=7.069×10−4 m2  ⟹  v2=Q2A2=4.80 m/sQ_2 = \frac{Q_1}{2} = 3.39 \times 10^{-3}\text{ m}^3/\text{s} \implies A_2 = \pi (0.0150\text{ m})^2 = 7.069 \times 10^{-4}\text{ m}^2 \implies v_2 = \frac{Q_2}{A_2} = 4.80\text{ m/s}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the cross-sectional areas of both the inlet pipe and the branch pipes from their diameters.

You correctly applied the conservation of volume to determine that each delivery branch carries half the inlet flow.

You calculated the discharge speed v2=4.80 m/sv_2 = 4.80\text{ m/s} accurately.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign convention omission

You assigned a positive sign to the incoming volumetric flow rate instead of following the required sign convention.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the absolute physical magnitude of a flow rate (Av>0A v > 0) with a signed net flux across a control surface, where inward normal vectors point into the domain and require a negative sign under outward-positive conventions.

REASONING PATH
Your ACEpath teacher’s suggested approach
Net-Flux Sign Rule
  • By convention, any volumetric flux directed outward from a control volume is positive (+Q+Q), while any flux directed into the control volume is negative (−Q-Q).

  • Always check whether a stream is entering or leaving the node before assigning its algebraic sign.

Nodal Balance Equation
  • ∑Qout−∑Qin=0\sum Q_{\text{out}} - \sum Q_{\text{in}} = 0, or ∑Qsigned=0\sum Q_{\text{signed}} = 0.

  • Verify that all inward streams carry negative signs so the sum of physical magnitudes naturally balances to zero.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the nodal continuity equation with inward flux taken as negative: −Q1+Q2+Q3=0-Q_1 + Q_2 + Q_3 = 0.

  2. Evaluate the signed inlet flux using Q1=−A1v1=−π(0.0600 m)24(2.40 m/s)=−6.79×10−3 m3/sQ_1 = -A_1 v_1 = -\frac{\pi (0.0600\text{ m})^2}{4}(2.40\text{ m/s}) = -6.79 \times 10^{-3}\text{ m}^3/\text{s}.

  3. Divide the magnitude equally between the two branches: Q2=Q3=∣Q1∣2=3.393×10−3 m3/sQ_2 = Q_3 = \frac{|Q_1|}{2} = 3.393 \times 10^{-3}\text{ m}^3/\text{s}.

  4. Calculate the exit velocity: v2=Q2A2=3.393×10−3 m3/sπ(0.0150 m)2=4.80 m/sv_2 = \frac{Q_2}{A_2} = \frac{3.393 \times 10^{-3}\text{ m}^3/\text{s}}{\pi (0.0150\text{ m})^2} = 4.80\text{ m/s}.

Final answer

Continuity equation: −Q1+Q2+Q3=0-Q_1 + Q_2 + Q_3 = 0; signed inlet flux: Q1=−6.79×10−3 m3/sQ_1 = -6.79 \times 10^{-3}\text{ m}^3/\text{s}; branch exit speed: v2=4.80 m/sv_2 = 4.80\text{ m/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review control-volume flux conventions by practicing drawing outward surface normals at each boundary.

  • Solve continuity problems that feature multiple inlets and outlets to reinforce the signed balance equation.

OverviewACEpath Teacher's Diagnosis

02 The student uses the diameter ratio directly instead of squaring it to find the area ratio, leading to an incorrect discharge speed of 2.40 m/s.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Q1+Q2+Q3=0Q_1 + Q_2 + Q_3 = 0

  2. Step 2

    A1=π(0.0300 m)2=2.827×10−3 m2  ⟹  Q1=−A1v1=−(2.827×10−3 m2)(2.40 m/s)=−6.79×10−3 m3/sA_1 = \pi(0.0300\text{ m})^2 = 2.827 \times 10^{-3}\text{ m}^2 \implies Q_1 = -A_1 v_1 = -(2.827 \times 10^{-3}\text{ m}^2)(2.40\text{ m/s}) = -6.79 \times 10^{-3}\text{ m}^3/\text{s}

  3. Step 3

    v_2 = \left(\frac{v_1}{2}\right) \cdot \left(\frac{d_1}{d_2}\right) \implies v_2 = \left(\frac{2.40\text{ m/s}}{2}\right) \cdot \left(\frac{6.00\text{ cm}}{3.00\text{ cm}} ight) = 2.40\text{ m/s}

    Correct

    v2=Q2A2=12v1(d1d2)2=12(2.40 m/s)(6.00 cm3.00 cm)2=4.80 m/sv_2 = \frac{Q_2}{A_2} = \frac{1}{2} v_1 \left(\frac{d_1}{d_2}\right)^2 = \frac{1}{2}(2.40\text{ m/s})\left(\frac{6.00\text{ cm}}{3.00\text{ cm}}\right)^2 = 4.80\text{ m/s}

    You used the linear diameter ratio d1d2\frac{d_1}{d_2} instead of the area ratio (d1d2)2\left(\frac{d_1}{d_2}\right)^2. Cross-sectional area scales with the square of the diameter, A=πd24A = \frac{\pi d^2}{4}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly applied the net volumetric flux sign convention to establish continuity at the node.

You correctly computed the inlet area and the negative signed flux Q1Q_1.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Linear scaling instead of quadratic area scaling

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated pipe diameter as scaling linearly with cross-sectional area rather than quadratic in diameter (A∝d2A \propto d^2). Halving the diameter reduces the cross-sectional area by a factor of 4, not 2.

REASONING PATH
Your ACEpath teacher’s suggested approach
Area-Diameter Scaling Relationship
  • For a circular pipe, cross-sectional area is A=πd24A = \frac{\pi d^2}{4}, so the area ratio is A1A2=(d1d2)2\frac{A_1}{A_2} = \left(\frac{d_1}{d_2}\right)^2.

  • Always square the diameter ratio whenever converting flow rate or velocity between circular cross-sections.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the continuity equation for Branch 2 using the split flow: Q2=A2v2=12A1v1Q_2 = A_2 v_2 = \frac{1}{2} A_1 v_1.

  2. Solve for v2v_2 in terms of the diameter ratio: v2=12v1(d1d2)2v_2 = \frac{1}{2} v_1 \left(\frac{d_1}{d_2}\right)^2.

  3. Substitute the given numerical values: v2=12(2.40 m/s)(6.00 cm3.00 cm)2=12(2.40 m/s)(4)=4.80 m/sv_2 = \frac{1}{2}(2.40\text{ m/s})\left(\frac{6.00\text{ cm}}{3.00\text{ cm}}\right)^2 = \frac{1}{2}(2.40\text{ m/s})(4) = 4.80\text{ m/s}.

Final answer

v2=v3=4.80 m/sv_2 = v_3 = 4.80\text{ m/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the geometric relationship between circular cross-sectional area and diameter (A∝d2A \propto d^2).

  • Practice scaling problems involving pipe branching by writing A=πd24A = \frac{\pi d^2}{4} explicitly before solving for velocity.

OverviewACEpath Teacher's Diagnosis

03 The student fails to account for the flow splitting into two branches and equates the total inlet flux directly to the discharge flux of a single branch.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Q1+Q2=0Q_1 + Q_2 = 0

    Correct

    ∑Qnode=Q1+Q2+Q3=0\sum Q_{\text{node}} = Q_1 + Q_2 + Q_3 = 0 (or −∣Q1∣+Q2+Q3=0-|Q_1| + Q_2 + Q_3 = 0)

    The manifold splits into two delivery branches (Branch 2 and Branch 3), so the continuity equation must include all three branches at the junction node rather than treating it as a single two-pipe connection.

  2. Step 2

    A1=π(0.0300 m)2=2.827×10−3 m2  ⟹  Q1=−A1v1=−(2.827×10−3 m2)(2.40 m/s)=−6.79×10−3 m3/sA_1 = \pi (0.0300\text{ m})^2 = 2.827 \times 10^{-3}\text{ m}^2 \implies Q_1 = -A_1 v_1 = -(2.827 \times 10^{-3}\text{ m}^2)(2.40\text{ m/s}) = -6.79 \times 10^{-3}\text{ m}^3\text{/s}

  3. Step 3

    Q2=−Q1=6.79×10−3 m3/sQ_2 = -Q_1 = 6.79 \times 10^{-3}\text{ m}^3\text{/s}

    Correct

    Q2=Q3=∣Q1∣2=3.393×10−3 m3/sQ_2 = Q_3 = \frac{|Q_1|}{2} = 3.393 \times 10^{-3}\text{ m}^3\text{/s}

    Because Branch 3 was left out of the nodal balance in Step 1, you assigned all incoming volume flow to Branch 2 instead of dividing it equally between the two identical exit branches.

  4. Step 4

    A2=π(0.0150 m)2=7.069×10−4 m2  ⟹  v2=9.60 m/sA_2 = \pi (0.0150\text{ m})^2 = 7.069 \times 10^{-4}\text{ m}^2 \implies v_2 = 9.60\text{ m/s}

    Correct

    v2=Q2A2=3.393×10−3 m3/s7.069×10−4 m2=4.80 m/sv_2 = \frac{Q_2}{A_2} = \frac{3.393 \times 10^{-3}\text{ m}^3\text{/s}}{7.069 \times 10^{-4}\text{ m}^2} = 4.80\text{ m/s}

    Your area calculation for Branch 2 is accurate, but your speed is exactly twice the true value (4.80 m/s4.80\text{ m/s}) due to the doubled flow rate carried over from Step 3.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly computed the cross-sectional areas from the pipe diameters.

You accurately applied the inflow sign convention to state Q1Q_1 as a negative quantity.

You correctly identified the relationship between volumetric flow rate, area, and speed (v=Q/Av = Q/A).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Branch in Multi-Branch Junction

You treated the junction as a single entrance and single exit (Q1+Q2=0Q_1 + Q_2 = 0) instead of a three-way splitting manifold.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You neglected to account for all branches converging at the junction node when writing the continuity equation, overlooking the fact that total inflow divides among all outlet paths.

REASONING PATH
Your ACEpath teacher’s suggested approach
Node Inventory Check
  • For any pipe junction or manifold, conservation of volume requires ∑Qin=∑Qout\sum Q_{\text{in}} = \sum Q_{\text{out}}, accounting for every connected branch.

  • Before writing numbers, list all branches entering and leaving the junction to ensure every branch appears as a term in the continuity equation.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Account for equal flow division across both exit branches: Q2=Q3=∣Q1∣2=6.786×10−3 m3/s2=3.393×10−3 m3/sQ_2 = Q_3 = \frac{|Q_1|}{2} = \frac{6.786 \times 10^{-3}\text{ m}^3\text{/s}}{2} = 3.393 \times 10^{-3}\text{ m}^3\text{/s}.

  2. Use the exit branch cross-sectional area A2=7.069×10−4 m2A_2 = 7.069 \times 10^{-4}\text{ m}^2 to find the exit speed: v2=Q2A2=3.393×10−3 m3/s7.069×10−4 m2=4.80 m/sv_2 = \frac{Q_2}{A_2} = \frac{3.393 \times 10^{-3}\text{ m}^3\text{/s}}{7.069 \times 10^{-4}\text{ m}^2} = 4.80\text{ m/s}.

Final answer

∑Qnode=−Q1+Q2+Q3=0\sum Q_{\text{node}} = -Q_1 + Q_2 + Q_3 = 0, signed inlet flux Q1=−6.79×10−3 m3/sQ_1 = -6.79 \times 10^{-3}\text{ m}^3\text{/s}, exit speed v2=v3=4.80 m/sv_2 = v_3 = 4.80\text{ m/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always sketch or annotate the junction and write ∑Q=0\sum Q = 0 with one term per physical pipe branch before substituting values.

  • When a pipe splits into NN identical symmetric delivery pipes, remember that the volumetric flow rate in each delivery pipe is Qbranch=QtotalNQ_{\text{branch}} = \frac{Q_{\text{total}}}{N}.

Lock it in

Similar question

01

A single pipe with diameter d=4.0 cmd = 4.0\text{ cm} feeds water at v=1.5 m/sv = 1.5\text{ m/s} into a sealed junction box. Two identical exit pipes of diameter dexit=2.0 cmd_{\text{exit}} = 2.0\text{ cm} discharge the fluid equally. Write the nodal continuity equation using the outward-positive flux convention, state the signed inlet flux QinQ_{\text{in}}, and find the exit velocity vexitv_{\text{exit}}.

Answer

Nodal equation: −Qin+Q1+Q2=0-Q_{\text{in}} + Q_1 + Q_2 = 0. Area Ain=π(0.040 m)24≈1.257×10−3 m2A_{\text{in}} = \frac{\pi(0.040\text{ m})^2}{4} \approx 1.257 \times 10^{-3}\text{ m}^2, so signed flux Qin=−Ainv=−1.88×10−3 m3/sQ_{\text{in}} = -A_{\text{in}} v = -1.88 \times 10^{-3}\text{ m}^3/\text{s}. Each exit branch carries Qexit=0.942×10−3 m3/sQ_{\text{exit}} = 0.942 \times 10^{-3}\text{ m}^3/\text{s} with area Aexit=π(0.020 m)24≈3.142×10−4 m2A_{\text{exit}} = \frac{\pi(0.020\text{ m})^2}{4} \approx 3.142 \times 10^{-4}\text{ m}^2, giving exit speed vexit=QexitAexit=3.0 m/sv_{\text{exit}} = \frac{Q_{\text{exit}}}{A_{\text{exit}}} = 3.0\text{ m/s}.

02

A mixing chamber has two inlet pipes: Pipe A (dA=10.0 cmd_A = 10.0\text{ cm}, vA=1.20 m/sv_A = 1.20\text{ m/s}) and Pipe B (dB=6.00 cmd_B = 6.00\text{ cm}, vB=2.50 m/sv_B = 2.50\text{ m/s}). It has a single discharge pipe C (dC=8.00 cmd_C = 8.00\text{ cm}). Using the standard outward-positive flux convention, write the algebraic continuity equation for the chamber, compute the signed fluxes QAQ_A and QBQ_B, and determine the exit speed vCv_C.

Answer

Algebraic continuity equation: −QA−QB+QC=0-Q_A - Q_B + Q_C = 0. Inflow areas: AA=π(0.100)24≈7.854×10−3 m2A_A = \frac{\pi(0.100)^2}{4} \approx 7.854 \times 10^{-3}\text{ m}^2, AB=π(0.0600)24≈2.827×10−3 m2A_B = \frac{\pi(0.0600)^2}{4} \approx 2.827 \times 10^{-3}\text{ m}^2. Signed fluxes: QA=−AAvA=−9.42×10−3 m3/sQ_A = -A_A v_A = -9.42 \times 10^{-3}\text{ m}^3/\text{s} and QB=−ABvB=−7.07×10−3 m3/sQ_B = -A_B v_B = -7.07 \times 10^{-3}\text{ m}^3/\text{s}. Required exit flux QC=∣QA∣+∣QB∣=1.649×10−2 m3/sQ_C = |Q_A| + |Q_B| = 1.649 \times 10^{-2}\text{ m}^3/\text{s}. With exit area AC=π(0.0800)24≈5.027×10−3 m2A_C = \frac{\pi(0.0800)^2}{4} \approx 5.027 \times 10^{-3}\text{ m}^2, the exit speed is vC=QCAC=3.28 m/sv_C = \frac{Q_C}{A_C} = 3.28\text{ m/s}.

03

A hydraulic manifold connects three ports: Port 1 (d1=4.0 cmd_1 = 4.0\text{ cm}, inflow v1=3.0 m/sv_1 = 3.0\text{ m/s}), Port 2 (d2=2.0 cmd_2 = 2.0\text{ cm}, outflow v2=4.0 m/sv_2 = 4.0\text{ m/s}), and Port 3 (d3=3.0 cmd_3 = 3.0\text{ cm}). Assuming incompressible steady flow, write the signed continuity equation ∑Q=0\sum Q = 0, determine the signed flux Q3Q_3, and find the flow speed and direction (inflow or outflow) at Port 3.

Answer

Areas: A1=1.257×10−3 m2A_1 = 1.257 \times 10^{-3}\text{ m}^2, A2=3.142×10−4 m2A_2 = 3.142 \times 10^{-4}\text{ m}^2, A3=7.069×10−4 m2A_3 = 7.069 \times 10^{-4}\text{ m}^2. Signed fluxes: Q1=−A1v1=−3.770×10−3 m3/sQ_1 = -A_1 v_1 = -3.770 \times 10^{-3}\text{ m}^3/\text{s}, Q2=+A2v2=+1.257×10−3 m3/sQ_2 = +A_2 v_2 = +1.257 \times 10^{-3}\text{ m}^3/\text{s}. Nodal equation: Q1+Q2+Q3=0  ⟹  Q3=−(Q1+Q2)=−(−3.770×10−3+1.257×10−3)=+2.513×10−3 m3/sQ_1 + Q_2 + Q_3 = 0 \implies Q_3 = -(Q_1 + Q_2) = -(-3.770 \times 10^{-3} + 1.257 \times 10^{-3}) = +2.513 \times 10^{-3}\text{ m}^3/\text{s}. Since Q3>0Q_3 > 0, Port 3 is an outflow, with speed v3=Q3A3=2.513×10−37.069×10−4=3.56 m/sv_3 = \frac{Q_3}{A_3} = \frac{2.513 \times 10^{-3}}{7.069 \times 10^{-4}} = 3.56\text{ m/s}.

Loading workspace…