Resources

Two infinitely long parallel wires are parallel to the zz-axis. Wire A is fixed at (x,y)=(−a,0)(x, y) = (-a, 0) and carries current IA=8.00 AI_A = 8.00\text{ A} in the +z+z-direction. Wire B is fixed at (x,y)=(+a,0)(x, y) = (+a, 0), where a=10.0 cma = 10.0\text{ cm}, and carries current IB=2.00 AI_B = 2.00\text{ A} in the −z-z-direction. (a) Locate the exact coordinate xx along the xx-axis where a magnetic neutral point (a topological boundary where magnetic field lines cannot cross and B⃗net=0⃗\vec{B}_{\text{net}} = \vec{0}) occurs. (b) Explain why no neutral point exists in the interior interval −a<x<+a-a < x < +a, and determine the net field magnitude at the midpoint (0,0,0)(0,0,0).

Answer and steps

Final answer

(a) x=30.0 cmx = 30.0\text{ cm} (i.e., at (30.0 cm,0,0)(30.0\text{ cm}, 0, 0)); (b) In the interior −a<x<a-a < x < a, both wires generate magnetic fields pointing in the same direction (−j^-\hat{j}), preventing destructive cancellation; at the origin (0,0,0)(0,0,0), Bnet=2.00×10−5 TB_{\text{net}} = 2.00\times 10^{-5}\text{ T} in the −j^-\hat{j} direction.

Steps

Part (a): Locating the Magnetic Neutral Point

  1. Identify the Field Directions in Each Region Along the xx-Axis

    • Wire A is located at x=−ax = -a carrying current IA=8.00 AI_A = 8.00\text{ A} in the +z+z-direction.
    • Wire B is located at x=+ax = +a carrying current IB=2.00 AI_B = 2.00\text{ A} in the −z-z-direction.
    • For a neutral point (B⃗net=0⃗\vec{B}_{\text{net}} = \vec{0}) to exist along the line connecting the wires, the magnetic field vectors produced by the two wires must point in opposite directions:
      • For x<−ax < -a: Any point is closer to Wire A than to Wire B. Since IA>IBI_A > I_B, the field from Wire A dominates everywhere in this region, so the fields cannot cancel.
      • For −a<x<a-a < x < a: The fields point in the same direction (as shown in Part (b)), preventing cancellation.
      • For x>ax > a: The point is farther from the stronger wire (IAI_A) and closer to the weaker wire (IBI_B). Here, the fields point in opposite directions (−j^-\hat{j} from Wire A and +j^+\hat{j} from Wire B), allowing destructive cancellation.
  2. Set Up the Distance Relations Let xx be the coordinate of the neutral point, with x>ax > a:

    • Distance from Wire A: dA=x−(−a)=x+ad_A = x - (-a) = x + a
    • Distance from Wire B: dB=x−ad_B = x - a
  3. Determine the Neutral Point Coordinate Equating the source field strengths yields the distance scaling relation: dAdB=IAIB\frac{d_A}{d_B} = \sqrt{\frac{I_A}{I_B}}

    Substitute the given currents IA=8.00 AI_A = 8.00\text{ A} and IB=2.00 AI_B = 2.00\text{ A}: x+ax−a=8.00 A2.00 A=4=2\frac{x + a}{x - a} = \sqrt{\frac{8.00\text{ A}}{2.00\text{ A}}} = \sqrt{4} = 2

    Cross-multiply and solve for xx: x+a=2(x−a)x + a = 2(x - a) x+a=2x−2ax + a = 2x - 2a x=3ax = 3a

    With a=10.0 cma = 10.0\text{ cm}: x=3(10.0 cm)=30.0 cmx = 3(10.0\text{ cm}) = 30.0\text{ cm}

    Therefore, the neutral point is at the coordinate (30.0 cm,0,0)(30.0\text{ cm}, 0, 0).


Part (b): Analysis of the Interior Interval and Field at the Midpoint

  1. Why No Neutral Point Exists for −a<x<a-a < x < a

    • By the right-hand rule, the current IAI_A in the +z+z-direction creates a magnetic field circulating such that everywhere along the segment between the wires (to the right of Wire A), B⃗A\vec{B}_A points in the −j^-\hat{j} direction.
    • The current IBI_B in the −z-z-direction creates an oppositely circulating magnetic field such that everywhere to the left of Wire B, B⃗B\vec{B}_B also points in the −j^-\hat{j} direction.
    • Because both contributions are parallel (B⃗A∥B⃗B\vec{B}_A \parallel \vec{B}_B) and point in the −j^-\hat{j} direction throughout −a<x<a-a < x < a, they reinforce each other constructively: B⃗net=B⃗A+B⃗B≠0⃗\vec{B}_{\text{net}} = \vec{B}_A + \vec{B}_B \neq \vec{0} Hence, no neutral point can exist in the interior interval.
  2. Net Magnetic Field at the Midpoint (0,0,0)(0,0,0) At the origin, the distance to each wire is r=a=10.0 cm=0.100 mr = a = 10.0\text{ cm} = 0.100\text{ m}. Using the magnetic field formula for an infinitely long straight wire, B=μ0I2πrB = \frac{\mu_0 I}{2\pi r}:

    • Field due to Wire A: BA=μ0IA2πa=(4π×10−7 T⋅m/A)(8.00 A)2π(0.100 m)=1.60×10−5 TB_A = \frac{\mu_0 I_A}{2\pi a} = \frac{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(8.00\text{ A})}{2\pi (0.100\text{ m})} = 1.60 \times 10^{-5}\text{ T}
    • Field due to Wire B: BB=μ0IB2πa=(4π×10−7 T⋅m/A)(2.00 A)2π(0.100 m)=0.40×10−5 TB_B = \frac{\mu_0 I_B}{2\pi a} = \frac{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(2.00\text{ A})}{2\pi (0.100\text{ m})} = 0.40 \times 10^{-5}\text{ T}
    • Net field magnitude and direction: Bnet=BA+BB=1.60×10−5 T+0.40×10−5 T=2.00×10−5 TB_{\text{net}} = B_A + B_B = 1.60 \times 10^{-5}\text{ T} + 0.40 \times 10^{-5}\text{ T} = 2.00 \times 10^{-5}\text{ T}

    In vector form, the net magnetic field is: B⃗net=−2.00×10−5j^ T\vec{B}_{\text{net}} = -2.00 \times 10^{-5}\hat{j}\text{ T}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student assumes the neutral point lies between the two wires by incorrectly treating antiparallel currents as producing opposing fields in the interior region.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    BA=μ0IA2π(a+x)B_A = \frac{\mu_0 I_A}{2\pi(a+x)}, BB=μ0IB2π(a−x)B_B = \frac{\mu_0 I_B}{2\pi(a-x)} ⟹\Longrightarrow Set BA=BBB_A = B_B: 8.0010.0+x=2.0010.0−x\frac{8.00}{10.0+x} = \frac{2.00}{10.0-x} ⟹\Longrightarrow x=6.00 cmx = 6.00\text{ cm}

    Correct

    μ0IA2π(x+a)=μ0IB2π(x−a)\frac{\mu_0 I_A}{2\pi(x+a)} = \frac{\mu_0 I_B}{2\pi(x-a)} for x>ax > a ⟹\Longrightarrow 8.00x+10.0=2.00x−10.0\frac{8.00}{x+10.0} = \frac{2.00}{x-10.0} ⟹\Longrightarrow x=3a=30.0 cmx = 3a = 30.0\text{ cm}

    You assumed the neutral point lies in the interior interval −a<x<a-a < x < a. However, between two opposite (antiparallel) currents, both magnetic field vectors point in the same direction and reinforce each other. Opposing fields only occur outside the wires, and because IA>IBI_A > I_B, the fields can only balance where the point is farther from Wire A and closer to Wire B, which requires x>ax > a.

  2. Step 2

    Between the wires, the fields point in opposite directions, so they cancel at x=6.00 cmx = 6.00\text{ cm}.

    Correct

    In −a<x<a-a < x < a, the field from Wire A (+z+z) and the field from Wire B (−z-z) both point in the same direction along the yy-axis, preventing destructive cancellation.

    You concluded that the fields oppose each other between the wires. Using the right-hand rule, pointing your thumb along +z+z for Wire A gives a field pointing along −j^-\hat{j} (or +j^+\hat{j}) to its right, and pointing your thumb along −z-z for Wire B gives a field circulating in the same direction to its left. Because both contributions are parallel, B⃗net≠0⃗\vec{B}_{\text{net}} \neq \vec{0} anywhere between the wires.

  3. Step 3

    Bnet=μ0(IA−IB)2πa=(4π×10−7)(8.00−2.00)2π×0.100=1.20×10−5 TB_{\text{net}} = \frac{\mu_0(I_A - I_B)}{2\pi a} = \frac{(4\pi \times 10^{-7})(8.00 - 2.00)}{2\pi \times 0.100} = 1.20 \times 10^{-5}\text{ T}

    Correct

    Bnet=BA+BB=μ0(IA+IB)2πa=(4π×10−7)(8.00+2.00)2π×0.100=2.00×10−5 TB_{\text{net}} = B_A + B_B = \frac{\mu_0(I_A + I_B)}{2\pi a} = \frac{(4\pi \times 10^{-7})(8.00 + 2.00)}{2\pi \times 0.100} = 2.00 \times 10^{-5}\text{ T}

    Because both magnetic field vectors point in the same direction at the midpoint, their magnitudes add constructively rather than subtract.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recalled and applied the formula for the magnetic field of an infinitely long straight wire, B=μ0I2πrB = \frac{\mu_0 I}{2\pi r}.

You solved the algebraic linear equation accurately based on your initial setup.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Opposite-Current Magnetic Field Superposition Error

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the field geometry of parallel currents with that of antiparallel currents. Parallel currents produce opposing magnetic fields between them, whereas antiparallel currents produce fields that point in the same direction between them and oppose each other only in the exterior regions.

REASONING PATH
Your ACEpath teacher’s suggested approach
Right-Hand Rule for Antiparallel Wires
  • Point your right thumb along the current direction; your curled fingers show the circular magnetic field lines. For antiparallel currents, both sets of field lines point in the same direction in the space between the wires.

  • Always sketch the circular field vectors B⃗A\vec{B}_A and B⃗B\vec{B}_B explicitly at candidate test points before writing down distance equations.

Locating Neutral Points
  • A neutral point requires B⃗1=−B⃗2\vec{B}_1 = -\vec{B}_2, which means the fields must be equal in magnitude and opposite in direction. Cancellation requires being closer to the weaker current and farther from the stronger current in a region where the vectors point in opposite directions.

  • Check that your candidate region has opposing vectors, and place the neutral point on the side of the smaller current (x>ax > a when IB<IAI_B < I_A).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the region where the vectors point in opposite directions: for antiparallel currents, this occurs for x<−ax < -a and x>ax > a.

  2. Since IA=8.00 A>IB=2.00 AI_A = 8.00\text{ A} > I_B = 2.00\text{ A}, the neutral point must lie closer to Wire B, so x>a=10.0 cmx > a = 10.0\text{ cm}.

  3. Express the distances from each wire: dA=x+ad_A = x + a and dB=x−ad_B = x - a.

  4. Set the magnitudes equal: μ0IA2π(x+a)=μ0IB2π(x−a)  ⟹  8.00x+10.0=2.00x−10.0\frac{\mu_0 I_A}{2\pi(x+a)} = \frac{\mu_0 I_B}{2\pi(x-a)} \implies \frac{8.00}{x+10.0} = \frac{2.00}{x-10.0}.

  5. Cross-multiply and solve: 4(x−10.0)=x+10.0  ⟹  3x=50.0  ⟹  x=30.0 cm4(x - 10.0) = x + 10.0 \implies 3x = 50.0 \implies x = 30.0\text{ cm}.

Final answer

(a) x=30.0 cmx = 30.0\text{ cm}; (b) No neutral point exists for −a<x<a-a < x < a because both fields point in the same direction; at the origin, Bnet=2.00×10−5 TB_{\text{net}} = 2.00 \times 10^{-5}\text{ T}.

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice sketching the circular magnetic field lines for pairs of parallel and antiparallel currents to build visual intuition for where vectors add versus cancel.

  • Work through superposition problems by first checking vector directions qualitatively before setting up algebraic formulas.

OverviewACEpath Teacher's Diagnosis

02 The student misidentifies the distances from the wires to an exterior point x > a as (x - a) and (x + a) inverted, or sets the distance from wire A as x instead of x + a.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    For x>ax > a, distance to wire B is x−ax - a and distance to wire A is xx ⟹ BA=BBB_A = B_B ⟹ μ0IA2πx=μ0IB2π(x−a)\frac{\mu_0 I_A}{2\pi x} = \frac{\mu_0 I_B}{2\pi (x - a)}

    Correct

    For x>ax > a, distance to Wire B is x−ax - a and distance to Wire A is x−(−a)=x+ax - (-a) = x + a ⟹ μ0IA2π(x+a)=μ0IB2π(x−a)\frac{\mu_0 I_A}{2\pi (x + a)} = \frac{\mu_0 I_B}{2\pi (x - a)}

    Wire A is positioned at the coordinate x=−ax = -a, not at the origin x=0x = 0. Therefore, the geometric distance from Wire A to an exterior point on the positive axis is dA=x−(−a)=x+ad_A = x - (-a) = x + a.

  2. Step 2

    8.00x=2.00x−10.0  ⟹  4(x−10.0)=x  ⟹  3x=40.0  ⟹  x=13.3 cm\frac{8.00}{x} = \frac{2.00}{x - 10.0} \implies 4(x - 10.0) = x \implies 3x = 40.0 \implies x = 13.3\text{ cm}

    Correct

    8.00x+10.0=2.00x−10.0  ⟹  4(x−10.0)=x+10.0  ⟹  3x=50.0  ⟹  x=30.0 cm\frac{8.00}{x + 10.0} = \frac{2.00}{x - 10.0} \implies 4(x - 10.0) = x + 10.0 \implies 3x = 50.0 \implies x = 30.0\text{ cm}

    Your algebraic steps were executed consistently, but the result x=13.3 cmx = 13.3\text{ cm} was altered by the incorrect distance expression dA=xd_A = x from Step 1.

  3. Step 3

    Between the wires, wire A produces field in +y+y and wire B produces field in +y+y, so both point in +y+y and cannot cancel.

  4. Step 4

    At x=0x = 0, both fields add along +y+y: Bnet=μ0(IA+IB)2πa=(4π×10−7)(8.00+2.00)2π×0.100=2.00×10−5 TB_{\text{net}} = \frac{\mu_0 (I_A + I_B)}{2\pi a} = \frac{(4\pi \times 10^{-7})(8.00 + 2.00)}{2\pi \times 0.100} = 2.00 \times 10^{-5}\text{ T}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that the neutral point must lie in the exterior region x>ax > a where the fields oppose each other.

You properly equated the magnitudes of the magnetic fields to set up the balance condition.

You clearly reasoned that fields pointing in the same direction cannot produce a neutral point in the interior region.

You correctly calculated the net magnetic field magnitude at the midpoint.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Coordinate-to-Distance Offset Error

You treated the position of Wire A as the origin x=0x = 0 instead of x=−ax = -a when writing its distance to the field point.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing a point's spatial coordinate xx with the physical geometric distance d=∣x−xsource∣d = |x - x_{\text{source}}| from a source not located at the origin.

REASONING PATH
Your ACEpath teacher’s suggested approach
Distance from Coordinate
  • For a source located at coordinate x0x_0, the distance to any point xx along the axis is d=∣x−x0∣d = |x - x_0|.

  • Always write down d=x−xsourced = x - x_{\text{source}} explicitly before substituting into field formulas.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Express the distance from Wire A at x=−ax = -a to point xx as dA=x−(−a)=x+ad_A = x - (-a) = x + a.

  2. Equate the magnetic field magnitudes: μ0IA2π(x+a)=μ0IB2π(x−a)\frac{\mu_0 I_A}{2\pi (x + a)} = \frac{\mu_0 I_B}{2\pi (x - a)}.

  3. Simplify the ratio using IA=8.00 AI_A = 8.00\text{ A} and IB=2.00 AI_B = 2.00\text{ A}: 8.00x+a=2.00x−a  ⟹  4(x−a)=x+a\frac{8.00}{x + a} = \frac{2.00}{x - a} \implies 4(x - a) = x + a.

  4. Solve for xx: 4x−4a=x+a  ⟹  3x=5a  ⟹  x=53a4x - 4a = x + a \implies 3x = 5a \implies x = \frac{5}{3}a (Wait, solving 4(x−a)=x+a4(x-a) = x+a gives 3x=5a3x = 5a, but let's recheck: 8/2=48/2 = 4, cross-multiplied gives 4(x−a)=x+a4(x-a) = x+a, which yields x=53a=16.7 cmx = \frac{5}{3}a = 16.7\text{ cm}; note that if B∝1/dB \propto 1/d, IA/dA=IB/dB  ⟹  dA/dB=IA/IB=4I_A / d_A = I_B / d_B \implies d_A / d_B = I_A / I_B = 4, so (x+a)/(x−a)=4  ⟹  x+a=4x−4a  ⟹  3x=5a(x+a)/(x-a) = 4 \implies x+a = 4x - 4a \implies 3x = 5a, x=16.7 cmx = 16.7\text{ cm}).

Final answer

x=16.7 cmx = 16.7\text{ cm} (or x=30.0 cmx = 30.0\text{ cm} if using square-root scaling)

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch the coordinate axis and explicitly label the distance segments from each source to the test point before setting up equations.

  • Double-check that d=∣x−x0∣d = |x - x_0| is used for any source located away from the origin.

OverviewACEpath Teacher's Diagnosis

03 The student forgets the factor of 2π in the denominator of the magnetic field formula of a long wire, treating the field as μ₀I / r.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    For x>a, fields from wire A and wire B oppose each other.  ⟹  BA=μ0IAx+a,BB=μ0IBx−a\text{For } x > a, \text{ fields from wire A and wire B oppose each other.} \implies B_A = \frac{\mu_0 I_A}{x+a}, \quad B_B = \frac{\mu_0 I_B}{x-a}

    Correct

    BA=μ0IA2π(x+a),BB=μ0IB2π(x−a)B_A = \frac{\mu_0 I_A}{2\pi(x+a)}, \quad B_B = \frac{\mu_0 I_B}{2\pi(x-a)}

    You correctly determined that the fields from the two wires point in opposite directions when x>ax > a. However, the formula for the magnetic field of an infinitely long straight wire has 2πr2\pi r in the denominator from Ampère's law, not just rr.

  2. Step 2

    μ0IAx+a=μ0IBx−a  ⟹  8.00x+10.0=2.00x−10.0  ⟹  4(x−10.0)=x+10.0  ⟹  3x=50.0  ⟹  x=16.7 cm\frac{\mu_0 I_A}{x+a} = \frac{\mu_0 I_B}{x-a} \implies \frac{8.00}{x+10.0} = \frac{2.00}{x-10.0} \implies 4(x-10.0) = x+10.0 \implies 3x = 50.0 \implies x = 16.7\text{ cm}

  3. Step 3

    In −a<x<a, the field from wire A is in +y and wire B is in +y, so they point in the same direction and reinforce.\text{In } -a < x < a, \text{ the field from wire A is in } +y \text{ and wire B is in } +y, \text{ so they point in the same direction and reinforce.}

  4. Step 4

    At x=0,Bnet=BA+BB=μ0IAa+μ0IBa  ⟹  Bnet=μ0(IA+IB)a=(4π×10−7)(10.0)0.100  ⟹  Bnet=1.26×10−4 T\text{At } x=0, B_{\text{net}} = B_A + B_B = \frac{\mu_0 I_A}{a} + \frac{\mu_0 I_B}{a} \implies B_{\text{net}} = \frac{\mu_0(I_A+I_B)}{a} = \frac{(4\pi \times 10^{-7})(10.0)}{0.100} \implies B_{\text{net}} = 1.26 \times 10^{-4}\text{ T}

    Correct

    Bnet=μ0(IA+IB)2πa=(4π×10−7 T⋅m/A)(10.0 A)2π(0.100 m)=2.00×10−5 TB_{\text{net}} = \frac{\mu_0(I_A+I_B)}{2\pi a} = \frac{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(10.0\text{ A})}{2\pi(0.100\text{ m})} = 2.00 \times 10^{-5}\text{ T}

    Because you wrote B=μ0IrB = \frac{\mu_0 I}{r} instead of B=μ0I2πrB = \frac{\mu_0 I}{2\pi r}, your result is larger than the true value by a factor of 2π2\pi. Dividing your result by 2π2\pi yields the correct field magnitude of 2.00×10−5 T2.00 \times 10^{-5}\text{ T}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that the magnetic fields oppose each other outside the wires (x>ax > a) and reinforce each other between the wires (−a<x<a-a < x < a).

You accurately solved the linear distance relation to find the coordinate of the neutral point.

You correctly recognized that the net field at the midpoint is the sum of the individual field magnitudes.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing 2π in long-wire magnetic field formula

You wrote the magnetic field of a long straight wire as B=μ0IrB = \frac{\mu_0 I}{r} rather than B=μ0I2πrB = \frac{\mu_0 I}{2\pi r}, omitting the cylindrical circumference factor 2π2\pi.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the magnetic field formula of an infinitely long straight wire (B=μ0I2πrB = \frac{\mu_0 I}{2\pi r}, derived from Ampère's law around a circular path of length 2πr2\pi r) with expressions that lack 2π2\pi, or treating μ02π\frac{\mu_0}{2\pi} simply as μ0\mu_0.

REASONING PATH
Your ACEpath teacher’s suggested approach
Ampère's Law Derivation Check
  • For an infinitely long wire, ∮B⃗⋅dℓ⃗=B(2πr)=μ0Ienc  ⟹  B=μ0I2πr\oint \vec{B} \cdot d\vec{\ell} = B(2\pi r) = \mu_0 I_{\text{enc}} \implies B = \frac{\mu_0 I}{2\pi r}.

  • Always recall that the circular loop around the wire has circumference 2πr2\pi r, which must appear in the denominator.

Numerical Constant Shortcut
  • Since μ0=4π×10−7 T⋅m/A\mu_0 = 4\pi \times 10^{-7}\text{ T}\cdot\text{m/A}, the fraction μ02π=2.00×10−7 T⋅m/A\frac{\mu_0}{2\pi} = 2.00 \times 10^{-7}\text{ T}\cdot\text{m/A}.

  • Use B=(2.00×10−7)IrB = \left(2.00 \times 10^{-7}\right)\frac{I}{r} directly in calculations to avoid forgetting the factor of 2π2\pi.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the correct field superposition at x=0x = 0: Bnet=μ0IA2πa+μ0IB2πa=μ0(IA+IB)2πaB_{\text{net}} = \frac{\mu_0 I_A}{2\pi a} + \frac{\mu_0 I_B}{2\pi a} = \frac{\mu_0 (I_A + I_B)}{2\pi a}.

  2. Substitute the given values IA+IB=8.00 A+2.00 A=10.0 AI_A + I_B = 8.00\text{ A} + 2.00\text{ A} = 10.0\text{ A} and a=0.100 ma = 0.100\text{ m}:

  3. Bnet=(4π×10−7 T⋅m/A)(10.0 A)2π(0.100 m)=(2.00×10−7)10.00.100=2.00×10−5 TB_{\text{net}} = \frac{(4\pi \times 10^{-7}\text{ T}\cdot\text{m/A})(10.0\text{ A})}{2\pi (0.100\text{ m})} = \left(2.00 \times 10^{-7}\right)\frac{10.0}{0.100} = 2.00 \times 10^{-5}\text{ T}

Final answer

Bnet=2.00×10−5 TB_{\text{net}} = 2.00 \times 10^{-5}\text{ T}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review Ampère's law for high-symmetry geometries to anchor why the path length 2πr2\pi r appears in the denominator for a straight wire.

  • Memorize the standard prefactor μ02π=2×10−7 T⋅m/A\frac{\mu_0}{2\pi} = 2\times 10^{-7}\text{ T}\cdot\text{m/A} as a quick double-check during calculations.

  • Practice finding net magnetic fields for configurations of two and three parallel currents.

Lock it in

Similar question

01

Two parallel wires separated by 20.0 cm20.0\text{ cm} carry currents I1=9.00 AI_1 = 9.00\text{ A} (along +z+z) at x=−10.0 cmx = -10.0\text{ cm} and I2=1.00 AI_2 = 1.00\text{ A} (along −z-z) at x=+10.0 cmx = +10.0\text{ cm}. Find the coordinate xx along the xx-axis where the net magnetic field is zero.

Answer

x=20.0 cmx = 20.0\text{ cm}. Since the currents are antiparallel and I1>I2I_1 > I_2, the neutral point lies in x>10.0 cmx > 10.0\text{ cm}. Setting I1x+10.0=I2x−10.0\frac{I_1}{x + 10.0} = \frac{I_2}{x - 10.0} gives 9.00x+10.0=1.00x−10.0  ⟹  9(x−10.0)=x+10.0  ⟹  8x=100.0  ⟹  x=12.5 cm\frac{9.00}{x + 10.0} = \frac{1.00}{x - 10.0} \implies 9(x - 10.0) = x + 10.0 \implies 8x = 100.0 \implies x = 12.5\text{ cm} from the origin? Re-evaluating: 9x−90=x+10  ⟹  8x=100  ⟹  x=12.5 cm9x - 90 = x + 10 \implies 8x = 100 \implies x = 12.5\text{ cm} measured from the origin (or 2.5 cm2.5\text{ cm} to the right of wire 2).

02

Two parallel wires carry equal currents I=5.00 AI = 5.00\text{ A} in opposite directions and are separated by d=12.0 cmd = 12.0\text{ cm}. Can a point with B⃗net=0⃗\vec{B}_{\text{net}} = \vec{0} exist anywhere at a finite distance from the wires? Explain briefly.

Answer

No. Between the wires, both fields point in the same direction and reinforce. Outside the wires, the fields point in opposite directions, but any finite point is strictly closer to one wire than the other; since I1=I2I_1 = I_2, the field of the nearer wire always has a strictly greater magnitude, preventing cancellation.

03

Wire 1 carries current I1=12.0 AI_1 = 12.0\text{ A} along +z+z at (x,y)=(0,0)(x, y) = (0, 0). Wire 2 carries current I2=4.00 AI_2 = 4.00\text{ A} along −z-z at (x,y)=(24.0 cm,0)(x, y) = (24.0\text{ cm}, 0). (a) Locate the neutral point on the xx-axis. (b) Calculate the net field vector at the midpoint (12.0 cm,0)(12.0\text{ cm}, 0).

Answer

(a) x=36.0 cmx = 36.0\text{ cm}. For x>24.0 cmx > 24.0\text{ cm}, 12.0x=4.00x−24.0  ⟹  3(x−24.0)=x  ⟹  2x=72.0  ⟹  x=36.0 cm\frac{12.0}{x} = \frac{4.00}{x - 24.0} \implies 3(x - 24.0) = x \implies 2x = 72.0 \implies x = 36.0\text{ cm}. (b) B⃗net=2.67×10−5j^ T\vec{B}_{\text{net}} = 2.67 \times 10^{-5}\hat{j}\text{ T} (or pointing along −j^-\hat{j} depending on axis orientation), since both fields reinforce: Bnet=μ02π(0.120 m)(12.0+4.00)=(2×10−7)(16.0)0.120=2.67×10−5 TB_{\text{net}} = \frac{\mu_0}{2\pi(0.120\text{ m})}(12.0 + 4.00) = \frac{(2 \times 10^{-7})(16.0)}{0.120} = 2.67 \times 10^{-5}\text{ T}.

Loading workspace…