Resources

An electric immersion heater with a constant resistance of R=24.0 ΩR = 24.0\ \Omega is connected across a standard V=120 VV = 120\ \text{V} direct-current power supply. (a) Calculate the electric power dissipated as thermal energy by the heater. (b) Determine the total electrical energy delivered to the water if the heater operates continuously for Δt=15.0 min\Delta t = 15.0\ \text{min}.

Answer and steps

Final answer

(a) P=600 WP = 600\ \text{W}; (b) E=5.40×105 JE = 5.40 \times 10^5\ \text{J} (or 0.150 kW⋅h0.150\ \text{kW}\cdot\text{h})

Steps

01

Energy in Joules (J\text{J})

Part (a): Calculate the Electric Power Dissipated

Electric power PP can be expressed in terms of the potential difference VV across a resistor and its resistance RR using Joule's law: P=V2RP = \frac{V^2}{R} Substitute the given values, V=120 VV = 120\ \text{V} and R=24.0 ΩR = 24.0\ \Omega: P=(120 V)224.0 Ω=14 400 V224.0 Ω=600 WP = \frac{(120\ \text{V})^2}{24.0\ \Omega} = \frac{14\,400\ \text{V}^2}{24.0\ \Omega} = 600\ \text{W} Alternative method: First find the current using Ohm's law, I=VR=120 V24.0 Ω=5.00 AI = \frac{V}{R} = \frac{120\ \text{V}}{24.0\ \Omega} = 5.00\ \text{A}. Then calculate power as P=VI=(120 V)(5.00 A)=600 WP = V I = (120\ \text{V})(5.00\ \text{A}) = 600\ \text{W}.

Part (b): Determine the Total Electrical Energy Delivered

Electrical energy EE delivered over a time interval Δt\Delta t is the product of power and time: E=P⋅ΔtE = P \cdot \Delta t

The watt (W\text{W}) is defined as one joule per second (J/s\text{J/s}). To calculate the energy in SI base units, convert the time from minutes to seconds:

Δt=15.0 min×60 s1 min=900 s\Delta t = 15.0\ \text{min} \times \frac{60\ \text{s}}{1\ \text{min}} = 900\ \text{s}

Now calculate the energy:

E=(600 W)(900 s)=5.40×105 JE = (600\ \text{W})(900\ \text{s}) = 5.40 \times 10^5\ \text{J}

Common Pitfall: Forgetting to convert time to seconds before multiplying by power in watts will yield an incorrect result in watt-minutes rather than standard joules.

02

Energy in Kilowatt-hours (kW⋅h\text{kW}\cdot\text{h})

Alternatively, energy can be calculated in standard electrical utility units:

P=600 W=0.600 kWP = 600\ \text{W} = 0.600\ \text{kW}

Δt=15.0 min60 min/h=0.250 h\Delta t = \frac{15.0\ \text{min}}{60\ \text{min/h}} = 0.250\ \text{h}

E=(0.600 kW)(0.250 h)=0.150 kW⋅hE = (0.600\ \text{kW})(0.250\ \text{h}) = 0.150\ \text{kW}\cdot\text{h}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the voltage when applying the power formula, writing P = V/R instead of P = V²/R.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P=VR  ⟹  P=120 V24.0 Ω=5.0 WP = \frac{V}{R} \implies P = \frac{120\text{ V}}{24.0\ \Omega} = 5.0\text{ W}

    Correct

    P=V2R=(120 V)224.0 Ω=600 WP = \frac{V^2}{R} = \frac{(120\text{ V})^2}{24.0\ \Omega} = 600\text{ W}

    The formula VR\frac{V}{R} gives electric current II in amperes (5.0 A5.0\text{ A}), not power. Electric power in terms of voltage and resistance is P=V2RP = \frac{V^2}{R} or P=VIP = V I.

  2. Step 2

    Δt=15.0 min=900 s\Delta t = 15.0\text{ min} = 900\text{ s}

  3. Step 3

    E=P×Δt=5.0 W×900 s=4500 JE = P \times \Delta t = 5.0\text{ W} \times 900\text{ s} = 4500\text{ J}

    Correct

    E=P⋅Δt=600 W×900 s=5.40×105 JE = P \cdot \Delta t = 600\text{ W} \times 900\text{ s} = 5.40 \times 10^5\text{ J}

    Your relationship E=PΔtE = P \Delta t and multiplication are correct, but the result is affected by the incorrect power value calculated in part (a).

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the time interval of 15.0 min15.0\text{ min} into 900 s900\text{ s}.

You applied the correct relationship between electrical energy, power, and time (E=PΔtE = P \Delta t).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula confusion between current and power

You wrote P=VRP = \frac{V}{R} instead of P=V2RP = \frac{V^2}{R}, confusing Ohm's law for current with the formula for electric power.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing Ohm's law (I=VRI = \frac{V}{R}) with Joule's power law (P=VI=V2R=I2RP = V I = \frac{V^2}{R} = I^2 R). Evaluating VR\frac{V}{R} computes the current in amperes, not the dissipated power in watts.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check power formulas
  • Power represents energy per unit time: P=VIP = V I. Combining with Ohm's law (V=IRV = I R) yields P=I2R=V2RP = I^2 R = \frac{V^2}{R}.

  • When given VV and RR, ensure you square the potential difference: P=V2RP = \frac{V^2}{R}.

Unit and dimensional check
  • VΩ=A\frac{\text{V}}{\Omega} = \text{A} (amperes), whereas W=V×A=V2Ω\text{W} = \text{V} \times \text{A} = \frac{\text{V}^2}{\Omega}.

  • Always verify that your formula's units evaluate to watts (J/s\text{J/s}) rather than amperes.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate power using P=V2R=(120 V)224.0 Ω=14 400 V224.0 Ω=600 WP = \frac{V^2}{R} = \frac{(120\text{ V})^2}{24.0\ \Omega} = \frac{14\,400\text{ V}^2}{24.0\ \Omega} = 600\text{ W}.

  2. Multiply power by the time interval in seconds: E=P⋅Δt=(600 W)(900 s)=5.40×105 JE = P \cdot \Delta t = (600\text{ W})(900\text{ s}) = 5.40 \times 10^5\text{ J}.

Final answer

(a) P=600 WP = 600\text{ W}; (b) E=5.40×105 JE = 5.40 \times 10^5\text{ J} (or 0.150 kW⋅h0.150\text{ kW}\cdot\text{h})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the three interrelated formulas for electric power: P=VIP = V I, P=I2RP = I^2 R, and P=V2RP = \frac{V^2}{R}.

  • Practice deriving P=V2RP = \frac{V^2}{R} by substituting I=VRI = \frac{V}{R} into P=VIP = V I whenever solving circuit power problems.

OverviewACEpath Teacher's Diagnosis

02 The student uses the time directly in minutes without converting to SI seconds, resulting in energy calculated in watt-minutes instead of joules.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    P=V2R  ⟹  P=(120 V)224.0 Ω=1440024.0=600 WP = \frac{V^2}{R} \implies P = \frac{(120\text{ V})^2}{24.0\ \Omega} = \frac{14400}{24.0} = 600\text{ W}

  2. Step 2

    E=P×ΔtE = P \times \Delta t

  3. Step 3

    E=600 W×15.0 min=9000 JE = 600\text{ W} \times 15.0\text{ min} = 9000\text{ J}

    Correct

    Δt=15.0 min×60 s/min=900 s  ⟹  E=(600 W)(900 s)=5.40×105 J\Delta t = 15.0\text{ min} \times 60\text{ s/min} = 900\text{ s} \implies E = (600\text{ W})(900\text{ s}) = 5.40 \times 10^5\text{ J}

    You multiplied power in watts by time in minutes and labeled the result as joules. Because 1 W=1 J/s1\text{ W} = 1\text{ J/s}, you must convert minutes to seconds (15.0 min=900 s15.0\text{ min} = 900\text{ s}) to obtain energy in standard joules (5.40×105 J5.40 \times 10^5\text{ J}).

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the formula P=V2RP = \frac{V^2}{R} to calculate electric power.

You completed the arithmetic accurately for part (a) to arrive at 600 W600\text{ W}.

You identified the fundamental definition linking electrical energy to power, E=PΔtE = P \Delta t.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of SI Unit Conversion for Time

You substituted Δt=15.0 min\Delta t = 15.0\text{ min} directly into E=PΔtE = P \Delta t instead of converting to seconds first.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You overlooked the dimensional definition of the watt (1 W=1 J/s1\text{ W} = 1\text{ J/s}), which requires time to be expressed in SI base units (seconds) for their product to yield joules (1 W⋅s=1 J1\text{ W}\cdot\text{s} = 1\text{ J}). Multiplying watts by minutes yields watt-minutes, not joules.

REASONING PATH
Your ACEpath teacher’s suggested approach
SI Unit Definition of Power
  • 1 W=1 J/s1\text{ W} = 1\text{ J/s}, so 1 J=1 W⋅s1\text{ J} = 1\text{ W}\cdot\text{s}.

  • Whenever an equation yields an answer in joules from watts, verify that time is expressed strictly in seconds.

Unit Cancellation Check
  • [E]=[P][Δt]=(Js)(s)=J[E] = [P][\Delta t] = \left(\frac{\text{J}}{\text{s}}\right)(\text{s}) = \text{J}.

  • Write out units explicitly in substitution lines: (600 J/s)(15.0 min)(600\text{ J/s})(15.0\text{ min}) does not cancel time units until multiplied by (60 s/1 min)(60\text{ s}/1\text{ min}).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert time to seconds: Δt=15.0 min×60 s1 min=900 s\Delta t = 15.0\text{ min} \times \frac{60\text{ s}}{1\text{ min}} = 900\text{ s}.

  2. Multiply power by time in seconds: E=PΔt=(600 W)(900 s)=540 000 J=5.40×105 JE = P \Delta t = (600\text{ W})(900\text{ s}) = 540\,000\text{ J} = 5.40 \times 10^5\text{ J}.

Final answer

(a) P=600 WP = 600\text{ W}; (b) E=5.40×105 JE = 5.40 \times 10^5\text{ J} (or 0.150 kW⋅h0.150\text{ kW}\cdot\text{h})

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out unit fractions explicitly whenever time is given in minutes or hours and the required energy unit is joules.

  • Practice verifying whether energy is requested in joules (requiring seconds) or kilowatt-hours (requiring kilowatts and hours).

OverviewACEpath Teacher's Diagnosis

03 The student misremembers the power formula as P = V² × R instead of dividing by resistance.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P=V2×R  ⟹  P=(120 V)2×24.0 Ω=14400×24.0=345600 WP = V^2 \times R \implies P = (120\text{ V})^2 \times 24.0\ \Omega = 14400 \times 24.0 = 345600\text{ W}

    Correct

    P=V2R=(120 V)224.0 Ω=600 WP = \frac{V^2}{R} = \frac{(120\text{ V})^2}{24.0\ \Omega} = 600\text{ W}

    You multiplied V2V^2 by RR instead of dividing by RR. Since Ohm's law gives I=VRI = \frac{V}{R}, substituting into P=VIP = V I yields P=V2RP = \frac{V^2}{R}.

  2. Step 2

    Δt=15.0×60 s=900 s\Delta t = 15.0 \times 60\text{ s} = 900\text{ s}

  3. Step 3

    E=P×Δt=345600 W×900 s=3.11×108 JE = P \times \Delta t = 345600\text{ W} \times 900\text{ s} = 3.11 \times 10^8\text{ J}

    Correct

    E=P⋅Δt=(600 W)(900 s)=5.40×105 JE = P \cdot \Delta t = (600\text{ W})(900\text{ s}) = 5.40 \times 10^5\text{ J}

    Your method E=PΔtE = P \Delta t is correct, but the calculated numerical value is affected by the incorrect power from Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recalled that electrical energy is the product of power and elapsed time, E=PΔtE = P \Delta t.

You converted time from minutes to seconds before computing energy in joules.

You carried out your arithmetic and scientific notation rounding accurately according to your formulas.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula inversion or multiplication instead of division

You wrote P=V2×RP = V^2 \times R instead of P=V2RP = \frac{V^2}{R}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You conflated the two Joule heating formulas, confusing P=I2RP = I^2 R (where current is multiplied by resistance) with P=V2RP = \frac{V^2}{R} (where potential difference squared is divided by resistance).

REASONING PATH
Your ACEpath teacher’s suggested approach
Deriving Power from Ohm's Law
  • Start from fundamental definitions: P=VIP = V I and I=VRI = \frac{V}{R}. Substituting II into PP gives P=V(VR)=V2RP = V \left(\frac{V}{R}\right) = \frac{V^2}{R}.

  • Whenever you are unsure of whether resistance goes in the numerator or denominator, write down P=VIP = VI and Ohm's law to derive the relation.

Sanity Check via Physical Intuition
  • At a fixed voltage, increasing resistance reduces the current and thus decreases power dissipation: P∝1RP \propto \frac{1}{R}.

  • Check whether higher resistance yields less power at constant voltage; if it does, RR must be in the denominator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recalculate power using Joule's law with voltage and resistance: P=V2R=(120 V)224.0 Ω=14400 V224.0 Ω=600 WP = \frac{V^2}{R} = \frac{(120\text{ V})^2}{24.0\ \Omega} = \frac{14400\text{ V}^2}{24.0\ \Omega} = 600\text{ W}.

  2. Calculate total energy delivered using the correct power: E=P⋅Δt=(600 W)(900 s)=5.40×105 JE = P \cdot \Delta t = (600\text{ W})(900\text{ s}) = 5.40 \times 10^5\text{ J}.

Final answer

(a) P=600 WP = 600\text{ W}; (b) E=5.40×105 JE = 5.40 \times 10^5\text{ J} (or 0.150 kW⋅h0.150\text{ kW}\cdot\text{h})

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the three equivalent forms of electric power: P=VI=I2R=V2RP = VI = I^2 R = \frac{V^2}{R}.

  • Use dimensional analysis to verify: [V2/R]=V2/Ω=W[V^2 / R] = \text{V}^2 / \Omega = \text{W}, whereas [V2⋅R]=V2⋅Ω≠W[V^2 \cdot R] = \text{V}^2 \cdot \Omega \neq \text{W}.

Lock it in

Similar question

01

An electric kettle with a resistance of 16.0 Ω16.0\ \Omega operates on a 120 V120\text{ V} household line. Calculate the power rating of the kettle.

Answer

P=900 WP = 900\text{ W}. Key steps: P=V2R=(120 V)216.0 Ω=14 40016.0=900 WP = \frac{V^2}{R} = \frac{(120\text{ V})^2}{16.0\ \Omega} = \frac{14\,400}{16.0} = 900\text{ W}.

02

A 48.0 Ω48.0\ \Omega heating coil is connected to a 240 V240\text{ V} supply. How much energy in joules is consumed if the coil runs for 5.00 min5.00\text{ min}?

Answer

E=3.60×105 JE = 3.60 \times 10^5\text{ J}. Key steps: P=V2R=240248.0=1200 WP = \frac{V^2}{R} = \frac{240^2}{48.0} = 1200\text{ W}; convert time Δt=5.00 min×60 s/min=300 s\Delta t = 5.00\text{ min} \times 60\text{ s/min} = 300\text{ s}; E=PΔt=(1200 W)(300 s)=3.60×105 JE = P \Delta t = (1200\text{ W})(300\text{ s}) = 3.60 \times 10^5\text{ J}.

03

A portable electric space heater delivers 1.80×106 J1.80 \times 10^6\text{ J} of thermal energy in 20.0 min20.0\text{ min} when plugged into a 120 V120\text{ V} outlet. Determine (a) the heater's operating power and (b) its electrical resistance.

Answer

(a) P=1500 WP = 1500\text{ W}; (b) R=9.60 ΩR = 9.60\ \Omega. Key steps: (a) Δt=20.0×60=1200 s\Delta t = 20.0 \times 60 = 1200\text{ s}, so P=EΔt=1.80×106 J1200 s=1500 WP = \frac{E}{\Delta t} = \frac{1.80 \times 10^6\text{ J}}{1200\text{ s}} = 1500\text{ W}; (b) From P=V2RP = \frac{V^2}{R}, solve for resistance: R=V2P=12021500=14 4001500=9.60 ΩR = \frac{V^2}{P} = \frac{120^2}{1500} = \frac{14\,400}{1500} = 9.60\ \Omega.

Loading workspace…