Resources
A deep-well submersible drainage pump is rated at an input electrical power of (). The pump lifts groundwater through a vertical head of and discharges it at a volumetric flow rate of . The density of the pumped water is , and . Express all intermediate volumetric flow rates in standard SI units () and determine the mechanical operating efficiency of the pumping unit.
Answer and steps
Final answer
Steps
Convert Given Quantities to Standard SI Units
To find the mechanical operating efficiency of the pumping unit, we determine the useful hydraulic power delivered to the water and compare it to the electrical input power.
- Volumetric Flow Rate (): The pump delivers water at a rate of . Since and :
- Electrical Input Power (): Given with :
Calculate the Useful Hydraulic Output Power ()
The useful power exerted by the pump corresponds to the rate of work done in lifting the mass of water against gravity through the vertical head :
Where:
Substituting these values:
Determine the Operating Efficiency ()
The mechanical efficiency is the ratio of useful power output to total power input:
Substituting the evaluated powers:
Typical errors
01 The student forgets to convert minutes to seconds when converting the volumetric flow rate, resulting in an unphysical efficiency greater than 100%.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You converted liters to cubic meters by dividing by , but you left the time unit as minutes instead of converting to seconds (). Your resulting value is in , not .
- Step 2
- Step 3Correct
Your formula and substitution are correct in structure, but the numerical result is times too large because it inherited the unconverted flow rate from Step 1.
- Step 4Correct
You correctly applied the definition of efficiency , but using the inflated output power resulted in an impossible efficiency greater than .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recalled and applied the hydraulic power formula .
You correctly converted the input electrical power from horsepower to watts.
You correctly used the definition of mechanical efficiency .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou divided by to convert liters to cubic meters, but forgot to divide by to convert minutes to seconds.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisTreating compound units such as by converting only the numerator while carrying the denominator forward unchanged, coupled with not performing a reality check when obtaining an efficiency .
REASONING PATH
Your ACEpath teacher’s suggested approach- Compound Unit Factor-Label Method
When converting a rate , multiply by conversion factors for both the numerator and the denominator separately.
Write out both factors explicitly: .
- Physical Reality Check for Efficiency
By conservation of energy, the efficiency of a passive mechanical system must satisfy .
Whenever you compute an efficiency greater than , immediately inspect your power quantities for unit mismatch (especially minutes versus seconds or kilowatts versus watts).
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert completely into standard SI units: .
Calculate the hydraulic output power with standard SI values: .
Calculate the efficiency using : .
02 The student inverts the definition of efficiency by dividing input power by output power.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
- Step 4Correct
Efficiency is defined as the ratio of useful output power to total input power, . Dividing input by output yields an efficiency greater than , which violates the conservation of energy.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the volumetric flow rate into standard SI units of .
You converted the input horsepower rating into watts accurately.
You correctly applied the hydraulic power equation to find the useful power output.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou placed in the numerator and in the denominator when calculating efficiency.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused the roles of energy input and energy output in the definition of efficiency, overlooking the physical constraint that a real machine's useful output cannot exceed its total input.
REASONING PATH
Your ACEpath teacher’s suggested approach- Definition of Efficiency
Always place the useful power delivered to the system in the numerator and the total supplied power in the denominator.
- Sanity Check on Conservation of Energy
For any passive or real machine, ().
If your calculated efficiency exceeds (or ), pause immediately and check if you inverted the numerator and denominator.
CORRECTED PATH
ACEpath Teacher's DemonstrationRecall the definition of mechanical efficiency: .
Substitute and : .
Round to three significant figures: .
03 The student forgets to convert input horsepower to watts, calculating efficiency by dividing watts directly by horsepower.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You substituted directly in horsepower while was in watts. Efficiency requires both numerator and denominator to share identical units.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly transformed the volumetric flow rate into cubic meters per second.
You accurately formulated and calculated the hydraulic output power in watts.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou forgot to convert the electrical input power from horsepower to watts before computing efficiency.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking unit homogeneity in dimensionless efficiency formulas, and omitting a reality check when obtaining an efficiency far above 100%.
REASONING PATH
Your ACEpath teacher’s suggested approach- Unit Consistency in Ratios
Efficiency is a dimensionless fraction; both power quantities must be in the same units (e.g., both in watts).
Always convert mechanical or electrical power from horsepower to watts using before substituting into the efficiency formula.
- Sanity Check on Efficiency
By the conservation of energy, the efficiency of a passive pump or motor cannot exceed ().
If your calculated efficiency exceeds , pause immediately to check for mismatched units in the numerator and denominator.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert input power to watts: .
Compute efficiency: .
Lock it in
How do you convert a volumetric flow rate from to standard SI units ()?
Divide by (or multiply by ). Remember that both volume and time must be converted.
Similar question
A domestic sump pump lifts water through a height of at a flow rate of . What is the useful hydraulic output power of the pump? (Take and .)
Answer
. Key steps: ; .
An irrigation pump draws an electrical input power of and lifts water vertically by at a rate of . Determine the mechanical operating efficiency of the pump. (Take and .)
Answer
. Key steps: ; ; .
A deep-well pump with an operating efficiency of is driven by a motor (). If the vertical lifting head is , find the volumetric flow rate of water delivered in liters per minute (). (Take and .)
Answer
. Key steps: ; ; ; .