Resources

A deep-well submersible drainage pump is rated at an input electrical power of Pin=2.75 hpP_{\text{in}} = 2.75\text{ hp} (1 hp=746 W1\text{ hp} = 746\text{ W}). The pump lifts groundwater through a vertical head of H=28.5 mH = 28.5\text{ m} and discharges it at a volumetric flow rate of Q=320 L/minQ = 320\text{ L/min}. The density of the pumped water is ρ=1.00×103 kg/m3\rho = 1.00\times 10^3\text{ kg/m}^3, and g=9.80 m/s2g = 9.80\text{ m/s}^2. Express all intermediate volumetric flow rates in standard SI units (m3/s\text{m}^3/\text{s}) and determine the mechanical operating efficiency η\eta of the pumping unit.

Answer and steps

Final answer

η=72.8%\eta = 72.8\%

Steps

01

Convert Given Quantities to Standard SI Units

To find the mechanical operating efficiency of the pumping unit, we determine the useful hydraulic power delivered to the water and compare it to the electrical input power.

  1. Volumetric Flow Rate (QQ): The pump delivers water at a rate of 320 L/min320\text{ L/min}. Since 1 m3=1000 L1\text{ m}^3 = 1000\text{ L} and 1 min=60 s1\text{ min} = 60\text{ s}: Q=320 L1 min×1 m31000 L×1 min60 s=32060 000 m3/s≈5.333×10−3 m3/sQ = \frac{320\text{ L}}{1\text{ min}} \times \frac{1\text{ m}^3}{1000\text{ L}} \times \frac{1\text{ min}}{60\text{ s}} = \frac{320}{60\,000}\text{ m}^3\text{/s} \approx 5.333 \times 10^{-3}\text{ m}^3\text{/s}
  2. Electrical Input Power (PinP_{\text{in}}): Given Pin=2.75 hpP_{\text{in}} = 2.75\text{ hp} with 1 hp=746 W1\text{ hp} = 746\text{ W}: Pin=2.75×746 W=2051.5 WP_{\text{in}} = 2.75 \times 746\text{ W} = 2051.5\text{ W}
02

Calculate the Useful Hydraulic Output Power (PoutP_{\text{out}})

The useful power exerted by the pump corresponds to the rate of work done in lifting the mass of water against gravity through the vertical head HH: Pout=m˙gH=ρQgHP_{\text{out}} = \dot{m} g H = \rho Q g H

Where:

  • ρ=1.00×103 kg/m3\rho = 1.00 \times 10^3\text{ kg/m}^3
  • Q≈5.333×10−3 m3/sQ \approx 5.333 \times 10^{-3}\text{ m}^3\text{/s}
  • g=9.80 m/s2g = 9.80\text{ m/s}^2
  • H=28.5 mH = 28.5\text{ m}

Substituting these values: m˙=ρQ=(1.00×103 kg/m3)×(32060 000 m3/s)=163 kg/s≈5.333 kg/s\dot{m} = \rho Q = (1.00 \times 10^3\text{ kg/m}^3) \times \left(\frac{320}{60\,000}\text{ m}^3\text{/s}\right) = \frac{16}{3}\text{ kg/s} \approx 5.333\text{ kg/s}

Pout=(163 kg/s)×9.80 m/s2×28.5 m≈1490 WP_{\text{out}} = \left(\frac{16}{3}\text{ kg/s}\right) \times 9.80\text{ m/s}^2 \times 28.5\text{ m} \approx 1490\text{ W}

03

Determine the Operating Efficiency (η\eta)

The mechanical efficiency η\eta is the ratio of useful power output to total power input: η=PoutPin×100%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} \times 100\%

Substituting the evaluated powers: η=1490 W2051.5 W×100%≈72.8%\eta = \frac{1490\text{ W}}{2051.5\text{ W}} \times 100\% \approx 72.8\%

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert minutes to seconds when converting the volumetric flow rate, resulting in an unphysical efficiency greater than 100%.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Q=3201000=0.320 m3/sQ = \frac{320}{1000} = 0.320\text{ m}^3\text{/s}

    Correct

    Q=320 L1 min×1 m31000 L×1 min60 s=32060 000 m3/s≈5.333×10−3 m3/sQ = \frac{320\text{ L}}{1\text{ min}} \times \frac{1\text{ m}^3}{1000\text{ L}} \times \frac{1\text{ min}}{60\text{ s}} = \frac{320}{60\,000}\text{ m}^3\text{/s} \approx 5.333 \times 10^{-3}\text{ m}^3\text{/s}

    You converted liters to cubic meters by dividing by 10001000, but you left the time unit as minutes instead of converting to seconds (1 min=60 s1\text{ min} = 60\text{ s}). Your resulting value is in m3/min\text{m}^3\text{/min}, not m3/s\text{m}^3\text{/s}.

  2. Step 2

    Pin=2.75×746=2051.5 WP_{\text{in}} = 2.75 \times 746 = 2051.5\text{ W}

  3. Step 3

    Pout=1000×9.80×0.320×28.5=89376 WP_{\text{out}} = 1000 \times 9.80 \times 0.320 \times 28.5 = 89376\text{ W}

    Correct

    Pout=ρgQH=(1000 kg/m3)(9.80 m/s2)(32060 000 m3/s)(28.5 m)≈1490 WP_{\text{out}} = \rho g Q H = (1000\text{ kg/m}^3)(9.80\text{ m/s}^2)\left(\frac{320}{60\,000}\text{ m}^3\text{/s}\right)(28.5\text{ m}) \approx 1490\text{ W}

    Your formula Pout=ρgQHP_{\text{out}} = \rho g Q H and substitution are correct in structure, but the numerical result is 6060 times too large because it inherited the unconverted flow rate from Step 1.

  4. Step 4

    η=893762051.5=43.6 or 4360%\eta = \frac{89376}{2051.5} = 43.6\text{ or } 4360\%

    Correct

    η=PoutPin×100%=1489.6 W2051.5 W×100%≈72.8%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} \times 100\% = \frac{1489.6\text{ W}}{2051.5\text{ W}} \times 100\% \approx 72.8\%

    You correctly applied the definition of efficiency η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}}, but using the inflated output power resulted in an impossible efficiency greater than 100%100\%.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recalled and applied the hydraulic power formula P=ρgQHP = \rho g Q H.

You correctly converted the input electrical power from horsepower to watts.

You correctly used the definition of mechanical efficiency η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Incomplete Unit Conversion (Time Unit Omission)

You divided by 10001000 to convert liters to cubic meters, but forgot to divide by 6060 to convert minutes to seconds.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating compound units such as L/min\text{L/min} by converting only the numerator while carrying the denominator forward unchanged, coupled with not performing a reality check when obtaining an efficiency η>100%\eta > 100\%.

REASONING PATH
Your ACEpath teacher’s suggested approach
Compound Unit Factor-Label Method
  • When converting a rate Unit1Unit2\frac{\text{Unit}_1}{\text{Unit}_2}, multiply by conversion factors for both the numerator and the denominator separately.

  • Write out both factors explicitly: Lmin×1 m31000 L×1 min60 s=160 000 m3/s\frac{\text{L}}{\text{min}} \times \frac{1\text{ m}^3}{1000\text{ L}} \times \frac{1\text{ min}}{60\text{ s}} = \frac{1}{60\,000}\text{ m}^3\text{/s}.

Physical Reality Check for Efficiency
  • By conservation of energy, the efficiency of a passive mechanical system must satisfy 0≤η≤100%0 \le \eta \le 100\%.

  • Whenever you compute an efficiency greater than 100%100\%, immediately inspect your power quantities for unit mismatch (especially minutes versus seconds or kilowatts versus watts).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert QQ completely into standard SI units: Q=3201000×60 m3/s=81500 m3/s≈5.333×10−3 m3/sQ = \frac{320}{1000 \times 60}\text{ m}^3\text{/s} = \frac{8}{1500}\text{ m}^3\text{/s} \approx 5.333 \times 10^{-3}\text{ m}^3\text{/s}.

  2. Calculate the hydraulic output power with standard SI values: Pout=ρgQH=(1000)(9.80)(81500)(28.5)≈1489.6 WP_{\text{out}} = \rho g Q H = (1000)(9.80)\left(\frac{8}{1500}\right)(28.5) \approx 1489.6\text{ W}.

  3. Calculate the efficiency using Pin=2051.5 WP_{\text{in}} = 2051.5\text{ W}: η=1489.6 W2051.5 W×100%≈72.8%\eta = \frac{1489.6\text{ W}}{2051.5\text{ W}} \times 100\% \approx 72.8\%.

Final answer

η≈72.8%\eta \approx 72.8\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice using dimensional analysis to convert compound units like L/min\text{L/min}, km/h\text{km/h}, and g/cm3\text{g/cm}^3 into SI base units.

  • Always perform a physical sanity check on dimensionless ratios such as efficiency (which must not exceed 100%100\%) and coefficient of friction.

OverviewACEpath Teacher's Diagnosis

02 The student inverts the definition of efficiency by dividing input power by output power.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Q=32060000=0.005333 m3/sQ = \frac{320}{60000} = 0.005333\text{ m}^3/\text{s}

  2. Step 2

    Pin=2.75×746=2051.5 WP_{\text{in}} = 2.75 \times 746 = 2051.5\text{ W}

  3. Step 3

    Pout=1000×9.80×0.005333×28.5=1489.6 WP_{\text{out}} = 1000 \times 9.80 \times 0.005333 \times 28.5 = 1489.6\text{ W}

  4. Step 4

    η=PinPout=2051.51489.6=1.38 or 138%\eta = \frac{P_{\text{in}}}{P_{\text{out}}} = \frac{2051.5}{1489.6} = 1.38\text{ or } 138\%

    Correct

    η=PoutPin=1489.6 W2051.5 W≈0.726 or 72.8%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} = \frac{1489.6\text{ W}}{2051.5\text{ W}} \approx 0.726\text{ or } 72.8\%

    Efficiency is defined as the ratio of useful output power to total input power, η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}}. Dividing input by output yields an efficiency greater than 100%100\%, which violates the conservation of energy.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the volumetric flow rate into standard SI units of m3/s\text{m}^3/\text{s}.

You converted the input horsepower rating into watts accurately.

You correctly applied the hydraulic power equation P=ρgQHP = \rho g Q H to find the useful power output.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted efficiency ratio

You placed PinP_{\text{in}} in the numerator and PoutP_{\text{out}} in the denominator when calculating efficiency.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the roles of energy input and energy output in the definition of efficiency, overlooking the physical constraint that a real machine's useful output cannot exceed its total input.

REASONING PATH
Your ACEpath teacher’s suggested approach
Definition of Efficiency
  • η=Puseful, outPtotal, in=What you getWhat you pay for\eta = \frac{P_{\text{useful, out}}}{P_{\text{total, in}}} = \frac{\text{What you get}}{\text{What you pay for}}

  • Always place the useful power delivered to the system in the numerator and the total supplied power in the denominator.

Sanity Check on Conservation of Energy
  • For any passive or real machine, η≤100%\eta \le 100\% (Pout≤PinP_{\text{out}} \le P_{\text{in}}).

  • If your calculated efficiency exceeds 1.01.0 (or 100%100\%), pause immediately and check if you inverted the numerator and denominator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recall the definition of mechanical efficiency: η=PoutPin×100%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} \times 100\%.

  2. Substitute Pout=1489.6 WP_{\text{out}} = 1489.6\text{ W} and Pin=2051.5 WP_{\text{in}} = 2051.5\text{ W}: η=1489.62051.5≈0.7261\eta = \frac{1489.6}{2051.5} \approx 0.7261.

  3. Round to three significant figures: η≈72.8%\eta \approx 72.8\%.

Final answer

η=72.8%\eta = 72.8\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the mnemonic for efficiency: 'Output over Input' or 'What you get divided by what you pay'.

  • Perform a physical sanity check on every efficiency calculation to ensure η<100%\eta < 100\% for real systems.

OverviewACEpath Teacher's Diagnosis

03 The student forgets to convert input horsepower to watts, calculating efficiency by dividing watts directly by horsepower.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Q=32060000=0.005333 m3/sQ = \frac{320}{60000} = 0.005333\text{ m}^3/\text{s}

  2. Step 2

    Pout=1000×9.80×0.005333×28.5=1489.6 WP_{\text{out}} = 1000 \times 9.80 \times 0.005333 \times 28.5 = 1489.6\text{ W}

  3. Step 3

    η=PoutPin=1489.62.75=541.7 or 54170%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} = \frac{1489.6}{2.75} = 541.7\text{ or } 54170\%

    Correct

    η=PoutPin=1489.6 W2.75×746 W=1489.6 W2051.5 W≈72.8%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} = \frac{1489.6\text{ W}}{2.75 \times 746\text{ W}} = \frac{1489.6\text{ W}}{2051.5\text{ W}} \approx 72.8\%

    You substituted Pin=2.75P_{\text{in}} = 2.75 directly in horsepower while PoutP_{\text{out}} was in watts. Efficiency requires both numerator and denominator to share identical units.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly transformed the volumetric flow rate into cubic meters per second.

You accurately formulated and calculated the hydraulic output power in watts.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion omission in dimensionless ratio

You forgot to convert the electrical input power from horsepower to watts before computing efficiency.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking unit homogeneity in dimensionless efficiency formulas, and omitting a reality check when obtaining an efficiency far above 100%.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Consistency in Ratios
  • Efficiency η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}} is a dimensionless fraction; both power quantities must be in the same units (e.g., both in watts).

  • Always convert mechanical or electrical power from horsepower to watts using 1 hp=746 W1\text{ hp} = 746\text{ W} before substituting into the efficiency formula.

Sanity Check on Efficiency
  • By the conservation of energy, the efficiency of a passive pump or motor cannot exceed 100%100\% ( η≤1 \,\eta \le 1\,).

  • If your calculated efficiency exceeds 100%100\%, pause immediately to check for mismatched units in the numerator and denominator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert input power to watts: Pin=2.75 hp×746 W/hp=2051.5 WP_{\text{in}} = 2.75\text{ hp} \times 746\text{ W/hp} = 2051.5\text{ W}.

  2. Compute efficiency: η=PoutPin=1489.6 W2051.5 W≈0.7261=72.8%\eta = \frac{P_{\text{out}}}{P_{\text{in}}} = \frac{1489.6\text{ W}}{2051.5\text{ W}} \approx 0.7261 = 72.8\%.

Final answer

η=72.8%\eta = 72.8\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out explicit unit tags next to each number inside fractions to make mismatched units immediately obvious.

  • Perform a physical sanity check on every computed efficiency value: confirm that 0<η<100%0 < \eta < 100\%.

Lock it in

Similar question

01

A domestic sump pump lifts water through a height of H=4.50 mH = 4.50\text{ m} at a flow rate of Q=150 L/minQ = 150\text{ L/min}. What is the useful hydraulic output power PoutP_{\text{out}} of the pump? (Take ρ=1000 kg/m3\rho = 1000\text{ kg/m}^3 and g=9.80 m/s2g = 9.80\text{ m/s}^2.)

Answer

Pout=110 WP_{\text{out}} = 110\text{ W}. Key steps: Q=15060 000 m3/s=2.50×10−3 m3/sQ = \frac{150}{60\,000}\text{ m}^3\text{/s} = 2.50 \times 10^{-3}\text{ m}^3\text{/s}; Pout=ρgQH=(1000)(9.80)(2.50×10−3)(4.50)=110.25 W≈110 WP_{\text{out}} = \rho g Q H = (1000)(9.80)(2.50 \times 10^{-3})(4.50) = 110.25\text{ W} \approx 110\text{ W}.

02

An irrigation pump draws an electrical input power of Pin=1.20 kWP_{\text{in}} = 1.20\text{ kW} and lifts water vertically by H=18.0 mH = 18.0\text{ m} at a rate of Q=240 L/minQ = 240\text{ L/min}. Determine the mechanical operating efficiency η\eta of the pump. (Take ρ=1000 kg/m3\rho = 1000\text{ kg/m}^3 and g=9.80 m/s2g = 9.80\text{ m/s}^2.)

Answer

η=58.8%\eta = 58.8\%. Key steps: Q=24060 000=4.00×10−3 m3/sQ = \frac{240}{60\,000} = 4.00 \times 10^{-3}\text{ m}^3\text{/s}; Pout=(1000)(9.80)(4.00×10−3)(18.0)=705.6 WP_{\text{out}} = (1000)(9.80)(4.00 \times 10^{-3})(18.0) = 705.6\text{ W}; η=705.6 W1200 W×100%≈58.8%\eta = \frac{705.6\text{ W}}{1200\text{ W}} \times 100\% \approx 58.8\%.

03

A deep-well pump with an operating efficiency of η=68.0%\eta = 68.0\% is driven by a 3.00 hp3.00\text{ hp} motor (1 hp=746 W1\text{ hp} = 746\text{ W}). If the vertical lifting head is H=35.0 mH = 35.0\text{ m}, find the volumetric flow rate of water delivered in liters per minute (L/min\text{L/min}). (Take ρ=1000 kg/m3\rho = 1000\text{ kg/m}^3 and g=9.80 m/s2g = 9.80\text{ m/s}^2.)

Answer

Q=266 L/minQ = 266\text{ L/min}. Key steps: Pin=3.00×746=2238 WP_{\text{in}} = 3.00 \times 746 = 2238\text{ W}; Pout=ηPin=0.680×2238=1521.8 WP_{\text{out}} = \eta P_{\text{in}} = 0.680 \times 2238 = 1521.8\text{ W}; Q=PoutρgH=1521.8(1000)(9.80)(35.0)≈4.437×10−3 m3/sQ = \frac{P_{\text{out}}}{\rho g H} = \frac{1521.8}{(1000)(9.80)(35.0)} \approx 4.437 \times 10^{-3}\text{ m}^3\text{/s}; Q=(4.437×10−3)×60 000≈266 L/minQ = (4.437 \times 10^{-3}) \times 60\,000 \approx 266\text{ L/min}.

Loading workspace…