Resources
In a laboratory experiment using an insulated continuous-flow water calorimeter, an electric immersion heating coil is powered by an adjustable DC power bench. A calibrated digital multimeter measures a potential difference of across the coil and a current of through it. Water with specific heat capacity flows steadily through the chamber at a mass flow rate of . Assuming that of the total electrical power is absorbed by the fluid stream (with the remainder lost to ambient surroundings): (a) calculate the total electrical power input to the heating coil. (b) Determine the steady-state temperature rise of the flowing water.
Answer and steps
Final answer
(a) ; (b)
Steps
Part (a): Total Electrical Power Input
The electrical power delivered to a resistive heating element is given by the product of the potential difference across it and the current passing through it:
Substitute the given values into the equation:
Rounding to three significant figures gives:
Part (b): Steady-State Temperature Rise of the Water
-
Determine the useful thermal power absorbed by the water:
Only a fraction of the electrical power enters the water stream, with the rest dissipated to the surroundings:
-
Relate thermal power to mass flow rate and temperature rise:
In a steady-state continuous-flow calorimeter, the rate of heat absorption increases the temperature of the flowing mass:
where:
- is the mass flow rate,
- is the specific heat capacity of water,
- is the temperature rise.
-
Solve for :
Substitute the numerical values:
(Note on unit consistency: Expressing mass flow rate in aligns directly with in , so the mass units cancel cleanly without converting to kilograms.)
Typical errors
01 A student neglects the 92.5% efficiency factor and assumes 100% of electrical power is absorbed by water, resulting in an overestimated temperature rise of 64.7 °C.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You assumed of the electrical energy is absorbed by the water stream, but the problem states an efficiency of with the remaining power lost to the surroundings.
- Step 3Correct
Your flow calorimetry relationship is set up correctly, but substituting the unscaled electrical power propagated the error to your final temperature rise.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used the relationship to calculate the electrical power delivered to the immersion heater.
You correctly identified and applied the continuous-flow calorimetry formula relating power, mass flow rate, specific heat, and temperature change.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeNo, this was an omission of a given condition (efficiency ) rather than a simple arithmetic slip.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou equated total electrical input power directly to thermal power absorbed by the fluid, overlooking that real-world calorimeters lose energy to the surroundings unless stated to be ideal.
REASONING PATH
Your ACEpath teacher’s suggested approach- Efficiency in Energy Transfer
Always identify whether an efficiency or heat loss is specified before equating input power to thermal absorption.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate useful thermal power absorbed by the water:
Substitute into the flow equation:
Evaluate the temperature change:
(a) ; (b)
02 A student multiplies by the efficiency factor instead of dividing when relating absorbed power to total power, or divides by efficiency in the temperature rise formula, using P_absorbed = P_elec / 0.925 = 190.2 W.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Because only of the electrical energy reaches the water stream, the absorbed power must be less than the total input power, so you need to multiply by rather than divide.
- Step 3Correct
Your thermal flow equation and unit balancing were completely correct, but the final numerical temperature rise was affected by carrying forward the incorrect value of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the total electrical power input using .
You set up the continuous-flow calorimetry equation relating thermal power to mass flow rate, specific heat, and temperature rise correctly.
You handled the mass and energy units consistently without needing unnecessary conversions.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeDividing total power by the fractional efficiency rather than multiplying by it.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused the relationship between total input power and useful absorbed power. Efficiency represents the fraction of input power converted into useful output, so . Because , the useful output power must always be strictly less than the total supplied power.
REASONING PATH
Your ACEpath teacher’s suggested approach- Reality Check on Conservation of Energy
Whenever a device loses energy to the surroundings, verify that your calculated useful power is smaller than your source power before moving to the next step.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the thermal power absorbed by the water: .
Substitute the corrected absorbed power into the calorimetry equation: .
Evaluate the ratio: .
(a) ; (b)
03 A student inverts the formula for temperature rise as ΔT = ((dm/dt) × c) / P_absorbed, resulting in an incorrect value of 0.0167 °C.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
The steady-flow heat transfer rate is . When isolating , you must divide the power by the product , not the other way around.
- Step 4Correct
Your numerical evaluation accurately followed your inverted formula from Step 3, propagating the algebraic error into the final answer.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used to determine the electrical input power.
You correctly applied the efficiency to find the thermal power entering the fluid.
You used consistent units for mass flow rate () and specific heat capacity ().
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou accidentally placed the heat capacity rate in the numerator and the absorbed power in the denominator when rearranging the equation.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the independent energy input rate () with the heat capacity rate () during algebraic rearrangement, which can be caught early by checking that power divided by heat capacity rate yields temperature units.
REASONING PATH
Your ACEpath teacher’s suggested approach- Isolate the Desired Variable
If , then .
Divide both sides of by to isolate .
- Dimensional / Unit Check
.
Check whether your isolated expression gives units of degrees Celsius before plugging in numbers.
CORRECTED PATH
ACEpath Teacher's DemonstrationWrite the primary rate equation: .
Isolate by dividing both sides by : .
Substitute the numerical values: .
(a) ; (b)
Lock it in
How do you relate input electrical power to useful thermal power when efficiency is given?
. Only the fraction heats the substance; is lost to surroundings.
Similar question
A continuous-flow heater operating at and transfers thermal energy into water with an efficiency of . If water flows at a mass rate of with specific heat capacity , calculate the steady-state temperature rise .
Answer
. Key steps: ; ; .
Water () flows through an electric heating chamber at and undergoes a temperature rise of . If the heating coil operates at and draws , what is the thermal efficiency of the heater?
Answer
. Key steps: ; ; .
An electric immersion heater of resistance is connected across a line to heat an oil stream (). The unit has an efficiency of . To maintain a steady temperature increase of exactly , what mass flow rate in must be maintained?
Answer
. Key steps: ; ; .