Resources

A step-down transformer operating from an ac line source with an rms primary voltage of Vp=120 VV_p = 120\text{ V} supplies electrical power to a resistive heating element with resistance RL=4.50  ΩR_L = 4.50\;\Omega connected directly across its secondary terminals. An ammeter measures an rms primary current of Ip=0.800 AI_p = 0.800\text{ A}. Assuming ideal transformer behavior with negligible core and resistive losses: (a) Determine the turns ratio NsNp\frac{N_s}{N_p} of the transformer. (b) Calculate the secondary rms current IsI_s delivering power to the load.

Answer and steps

Final answer

(a) NsNp=0.173\frac{N_s}{N_p} = 0.173 (or 1:5.771:5.77); (b) Is=4.62 AI_s = 4.62\text{ A}

Steps

Part (a): Determine the turns ratio NsNp\frac{N_s}{N_p}

  1. Apply conservation of energy for an ideal transformer:
    In an ideal transformer, core losses and winding resistance are negligible, meaning the input electrical power delivered to the primary coil equals the output electrical power consumed by the load connected across the secondary coil: Pin=PoutP_{\text{in}} = P_{\text{out}}
  2. Express both powers in terms of given quantities:
    The primary power is the product of the primary rms voltage and primary rms current: Pin=VpIp=(120 V)(0.800 A)=96.0 WP_{\text{in}} = V_p I_p = (120\text{ V})(0.800\text{ A}) = 96.0\text{ W} The power delivered to the resistive load RLR_L is: Pout=Vs2RLP_{\text{out}} = \frac{V_s^2}{R_L}
  3. Solve for the secondary rms voltage VsV_s:
    Equating input and output power: Vs2RL=Pin\frac{V_s^2}{R_L} = P_{\text{in}} Vs2=Pin⋅RL=(96.0 W)(4.50  Ω)=432 V2V_s^2 = P_{\text{in}} \cdot R_L = (96.0\text{ W})(4.50\;\Omega) = 432\text{ V}^2 Vs=432 V≈20.785 VV_s = \sqrt{432}\text{ V} \approx 20.785\text{ V}
  4. Calculate the turns ratio NsNp\frac{N_s}{N_p}:
    The transformer equation relates the turns ratio directly to the ratio of voltages: NsNp=VsVp\frac{N_s}{N_p} = \frac{V_s}{V_p} NsNp=20.785 V120 V≈0.173(or 1:5.77)\frac{N_s}{N_p} = \frac{20.785\text{ V}}{120\text{ V}} \approx 0.173\quad (\text{or } 1 : 5.77)

Part (b): Calculate the secondary rms current IsI_s

  1. Use Ohm's Law across the secondary load:
    With the secondary voltage VsV_s established across the resistor RLR_L: Is=VsRL=20.785 V4.50  Ω≈4.62 AI_s = \frac{V_s}{R_L} = \frac{20.785\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}
  2. Alternative verification using current and turns ratio:
    For an ideal transformer, Is=Ip(NpNs)=IpNsNpI_s = I_p \left(\frac{N_p}{N_s}\right) = \frac{I_p}{\frac{N_s}{N_p}}: Is=0.800 A0.1732≈4.62 AI_s = \frac{0.800\text{ A}}{0.1732} \approx 4.62\text{ A} Alternatively, from Pout=Is2RLP_{\text{out}} = I_s^2 R_L: Is=PinRL=96.0 W4.50  Ω=21.333 A≈4.62 AI_s = \sqrt{\frac{P_{\text{in}}}{R_L}} = \sqrt{\frac{96.0\text{ W}}{4.50\;\Omega}} = \sqrt{21.333}\text{ A} \approx 4.62\text{ A}

Common Pitfall: Remember that a step-down transformer decreases voltage (Vs<VpV_s < V_p), but increases current (Is>IpI_s > I_p) to maintain power conservation. Be careful not to invert the relationship between turns ratio and current.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student confuses the inverse current ratio for an ideal transformer by assuming currents are directly proportional to turns ratio (Is/Ip = Ns/Np).

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pp=Vp⋅Ip=120⋅0.800=96.0 W  ⟹  Ps=Vs2RL=96.0 W  ⟹  Vs2=96.0⋅4.50=432  ⟹  Vs=20.8 VP_p = V_p \cdot I_p = 120 \cdot 0.800 = 96.0\text{ W} \implies P_s = \frac{V_s^2}{R_L} = 96.0\text{ W} \implies V_s^2 = 96.0 \cdot 4.50 = 432 \implies V_s = 20.8\text{ V}

  2. Step 2

    NsNp=VsVp=20.8120=0.173\frac{N_s}{N_p} = \frac{V_s}{V_p} = \frac{20.8}{120} = 0.173

  3. Step 3

    IsIp=NsNp\frac{I_s}{I_p} = \frac{N_s}{N_p}

    Correct

    IsIp=NpNs=VpVs\frac{I_s}{I_p} = \frac{N_p}{N_s} = \frac{V_p}{V_s}

    For an ideal transformer, power conservation (VpIp=VsIsV_p I_p = V_s I_s) requires that current is inversely proportional to voltage and turns ratio. In a step-down transformer where voltage decreases, current must increase.

  4. Step 4

    Is=Ip⋅NsNp=0.800⋅0.173=0.138 AI_s = I_p \cdot \frac{N_s}{N_p} = 0.800 \cdot 0.173 = 0.138\text{ A}

    Correct

    Is=VsRL=20.785 V4.50  Ω≈4.62 AI_s = \frac{V_s}{R_L} = \frac{20.785\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}

    This result was carried forward from the inverted current-turns ratio formula. Using either Ohm's law across the load (Is=VsRLI_s = \frac{V_s}{R_L}) or the correct inverse relation (Is=Ip⋅NpNs=0.800 A0.173I_s = I_p \cdot \frac{N_p}{N_s} = \frac{0.800\text{ A}}{0.173}) gives approximately 4.62 A4.62\text{ A}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly applied the power equation P=VIP = V I to determine the input power.

You used conservation of energy to relate primary power to load power.

You accurately solved for the secondary voltage and correctly computed the turns ratio NsNp=0.173\frac{N_s}{N_p} = 0.173.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Transformer Current Ratio

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the ratio of currents as directly proportional to the turns ratio ( rac{I_s}{I_p} = rac{N_s}{N_p}) instead of recognizing that conservation of electrical power requires currents to scale inversely with voltages and turns ( rac{I_s}{I_p} = rac{N_p}{N_s}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Power Conservation Rule
  • For an ideal transformer, input power equals output power: VpIp=VsIsV_p I_p = V_s I_s.

  • Rearrange VpIp=VsIsV_p I_p = V_s I_s to get IsIp=VpVs=NpNs\frac{I_s}{I_p} = \frac{V_p}{V_s} = \frac{N_p}{N_s} whenever you relate currents.

Step-Down Sanity Check
  • A step-down transformer steps voltage DOWN and current UP.

  • Check that since Vs<VpV_s < V_p, the secondary current must satisfy Is>IpI_s > I_p.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply Ohm's law directly across the secondary load: Is=VsRLI_s = \frac{V_s}{R_L}.

  2. Substitute the secondary voltage and load resistance: Is=20.785 V4.50  Ω≈4.62 AI_s = \frac{20.785\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}.

  3. Alternatively, use the inverse current relation: Is=Ip(NpNs)=0.800 A0.1732≈4.62 AI_s = I_p \left(\frac{N_p}{N_s}\right) = \frac{0.800\text{ A}}{0.1732} \approx 4.62\text{ A}.

Final answer

(a) NsNp=0.173\frac{N_s}{N_p} = 0.173; (b) Is=4.62 AI_s = 4.62\text{ A}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the derivation of transformer current ratios directly from Pin=PoutP_{\text{in}} = P_{\text{out}}.

  • Practice using direct Ohm's law (Is=VsRLI_s = \frac{V_s}{R_L}) on the secondary circuit as an independent verification step.

  • Always perform a step-up versus step-down sanity check on whether current should be larger or smaller than the primary current.

OverviewACEpath Teacher's Diagnosis

02 The student mistakenly treats the load resistance as being directly connected across the primary source to find primary voltage drop or power, assuming Vs = Vp.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Vs=Vp=120 VV_s = V_p = 120\text{ V}

    Correct

    Pin=VpIp=Pout=Vs2RL  ⟹  Vs=(120 V)(0.800 A)(4.50  Ω)≈20.8 VP_{\text{in}} = V_p I_p = P_{\text{out}} = \frac{V_s^2}{R_L} \implies V_s = \sqrt{(120\text{ V})(0.800\text{ A})(4.50\;\Omega)} \approx 20.8\text{ V}

    A transformer changes the voltage from primary to secondary, so Vs≠VpV_s \neq V_p. For an ideal transformer, input power equals output power: VpIp=Vs2RLV_p I_p = \frac{V_s^2}{R_L}.

  2. Step 2

    NsNp=VsVp=120120=1\frac{N_s}{N_p} = \frac{V_s}{V_p} = \frac{120}{120} = 1

    Correct

    NsNp=VsVp=20.8 V120 V≈0.173\frac{N_s}{N_p} = \frac{V_s}{V_p} = \frac{20.8\text{ V}}{120\text{ V}} \approx 0.173

    You correctly stated the relationship NsNp=VsVp\frac{N_s}{N_p} = \frac{V_s}{V_p}, but the numerical value was affected by your assumption that Vs=120 VV_s = 120\text{ V}.

  3. Step 3

    Is=VsRL=1204.50=26.7 AI_s = \frac{V_s}{R_L} = \frac{120}{4.50} = 26.7\text{ A}

    Correct

    Is=VsRL=20.8 V4.50  Ω≈4.62 AI_s = \frac{V_s}{R_L} = \frac{20.8\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}

    You correctly applied Ohm's law Is=VsRLI_s = \frac{V_s}{R_L}, but the calculation carried over the incorrect value of VsV_s.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the ideal transformer turns ratio formula relating voltage and turns.

You correctly applied Ohm's law to relate secondary current, secondary voltage, and load resistance.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Equating Primary and Secondary Voltages in a Transformer

You set the secondary voltage equal to the primary line voltage instead of solving for the secondary voltage using conservation of power.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the load resistance as if it were connected directly across the primary ac source, bypassing the voltage transformation and the power balance between primary and secondary circuits.

REASONING PATH
Your ACEpath teacher’s suggested approach
Ideal Power Conservation
  • For an ideal transformer, input electrical power equals output electrical power: Pin=PoutP_{\text{in}} = P_{\text{out}}, so VpIp=VsIs=Vs2RLV_p I_p = V_s I_s = \frac{V_s^2}{R_L}.

  • Calculate the input power from primary readings first, then set it equal to the power dissipated by the secondary load resistor.

Transformer Voltage Transformation
  • In a step-down transformer, Vs<VpV_s < V_p and NsNp<1\frac{N_s}{N_p} < 1.

  • Always verify that your calculated turns ratio is strictly less than 1 for a step-down transformer and strictly greater than 1 for a step-up transformer.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Find input power: Pin=VpIp=(120 V)(0.800 A)=96.0 WP_{\text{in}} = V_p I_p = (120\text{ V})(0.800\text{ A}) = 96.0\text{ W}.

  2. Equate input power to load power: Pout=Vs2RL=96.0 W  ⟹  Vs=(96.0 W)(4.50  Ω)=432 V≈20.785 VP_{\text{out}} = \frac{V_s^2}{R_L} = 96.0\text{ W} \implies V_s = \sqrt{(96.0\text{ W})(4.50\;\Omega)} = \sqrt{432}\text{ V} \approx 20.785\text{ V}.

  3. Compute turns ratio: NsNp=VsVp=20.785 V120 V≈0.173\frac{N_s}{N_p} = \frac{V_s}{V_p} = \frac{20.785\text{ V}}{120\text{ V}} \approx 0.173.

  4. Compute secondary current: Is=VsRL=20.785 V4.50  Ω≈4.62 AI_s = \frac{V_s}{R_L} = \frac{20.785\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A} (or using current conservation Is=PinVs=96.0 W20.785 V≈4.62 AI_s = \frac{P_{\text{in}}}{V_s} = \frac{96.0\text{ W}}{20.785\text{ V}} \approx 4.62\text{ A}).

Final answer

(a) NsNp≈0.173\frac{N_s}{N_p} \approx 0.173 (or 1:5.771:5.77); (b) Is≈4.62 AI_s \approx 4.62\text{ A}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice using the power conservation equation VpIp=Vs2RLV_p I_p = \frac{V_s^2}{R_L} whenever given primary operating values and a secondary load resistance.

  • Check your turns ratio value: a step-down transformer must always yield NsNp<1\frac{N_s}{N_p} < 1.

OverviewACEpath Teacher's Diagnosis

03 The student inverts the transformer impedance transformation formula, writing Rp = RL * (Ns/Np)² instead of RL * (Np/Ns)².

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Rp=VpIp=1200.800=150  ΩR_p = \frac{V_p}{I_p} = \frac{120}{0.800} = 150\;\Omega

  2. Step 2

    Rp=RL⋅(NsNp)2⟹(NsNp)2=RpRL=1504.50=33.33⟹NsNp=33.33=5.77R_p = R_L \cdot \left(\frac{N_s}{N_p}\right)^2 \Longrightarrow \left(\frac{N_s}{N_p}\right)^2 = \frac{R_p}{R_L} = \frac{150}{4.50} = 33.33 \Longrightarrow \frac{N_s}{N_p} = \sqrt{33.33} = 5.77

    Correct

    Rp=RL⋅(NpNs)2⟹(NpNs)2=1504.50=33.33⟹NsNp=133.33≈0.173R_p = R_L \cdot \left(\frac{N_p}{N_s}\right)^2 \Longrightarrow \left(\frac{N_p}{N_s}\right)^2 = \frac{150}{4.50} = 33.33 \Longrightarrow \frac{N_s}{N_p} = \frac{1}{\sqrt{33.33}} \approx 0.173

    You inverted the impedance reflection formula. The reflected primary resistance is Rp=RL(NpNs)2=RL(Ns/Np)2R_p = R_L \left(\frac{N_p}{N_s}\right)^2 = \frac{R_L}{(N_s/N_p)^2}. Because this is a step-down transformer (Vs<VpV_s < V_p), the turns ratio NsNp\frac{N_s}{N_p} must be less than 11.

  3. Step 3

    Vs=Vp⋅(NsNp)=120⋅5.77=692.4 V⟹Is=VsRL=692.44.50=154 AV_s = V_p \cdot \left(\frac{N_s}{N_p}\right) = 120 \cdot 5.77 = 692.4\text{ V} \Longrightarrow I_s = \frac{V_s}{R_L} = \frac{692.4}{4.50} = 154\text{ A}

    Correct

    Vs=Vp⋅(NsNp)=120 V⋅0.1732≈20.78 V⟹Is=VsRL=20.78 V4.50  Ω≈4.62 AV_s = V_p \cdot \left(\frac{N_s}{N_p}\right) = 120\text{ V} \cdot 0.1732 \approx 20.78\text{ V} \Longrightarrow I_s = \frac{V_s}{R_L} = \frac{20.78\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}

    Your method of finding VsV_s and IsI_s was conceptually consistent with your previous value, but the numerical answer is incorrect due to the inverted turns ratio from Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the effective input resistance of the primary circuit as Rp=150  ΩR_p = 150\;\Omega.

You correctly related secondary voltage to primary voltage through the turns ratio.

You correctly applied Ohm's law across the secondary load resistance to find secondary current.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted transformer impedance transformation formula

You wrote Rp=RL(NsNp)2R_p = R_L \left(\frac{N_s}{N_p}\right)^2 instead of Rp=RL(NpNs)2R_p = R_L \left(\frac{N_p}{N_s}\right)^2.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing how voltage, current, and impedance scale with the transformer turns ratio. Because Vp=Vs(NpNs)V_p = V_s \left(\frac{N_p}{N_s}\right) and Ip=Is(NsNp)I_p = I_s \left(\frac{N_s}{N_p}\right), dividing them gives Rp=VpIp=VsIs(NpNs)2=RL(NpNs)2R_p = \frac{V_p}{I_p} = \frac{V_s}{I_s} \left(\frac{N_p}{N_s}\right)^2 = R_L \left(\frac{N_p}{N_s}\right)^2.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check Step-Up vs. Step-Down
  • For a step-down transformer, secondary voltage decreases (Vs<VpV_s < V_p), so NsNp<1\frac{N_s}{N_p} < 1.

  • Whenever a problem specifies a step-down transformer, verify that your calculated turns ratio NsNp\frac{N_s}{N_p} is less than 1.

Derive Reflected Resistance from First Principles
  • Rp=VpIp=Vs(Np/Ns)Is(Ns/Np)=RL(NpNs)2R_p = \frac{V_p}{I_p} = \frac{V_s (N_p / N_s)}{I_s (N_s / N_p)} = R_L \left(\frac{N_p}{N_s}\right)^2.

  • If you forget whether the factor is NpNs\frac{N_p}{N_s} or NsNp\frac{N_s}{N_p}, re-derive it in one line using Vp/IpV_p/I_p.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the correct reflected resistance formula: Rp=RL(NpNs)2R_p = R_L \left(\frac{N_p}{N_s}\right)^2.

  2. Substitute Rp=150  ΩR_p = 150\;\Omega and RL=4.50  ΩR_L = 4.50\;\Omega: (NpNs)2=1504.50=1003≈33.33\left(\frac{N_p}{N_s}\right)^2 = \frac{150}{4.50} = \frac{100}{3} \approx 33.33.

  3. Take the square root to find NpNs=5.7735\frac{N_p}{N_s} = 5.7735, which gives the turns ratio NsNp=15.7735≈0.173\frac{N_s}{N_p} = \frac{1}{5.7735} \approx 0.173.

  4. Calculate secondary rms voltage: Vs=Vp(NsNp)=120 V×0.1732≈20.78 VV_s = V_p \left(\frac{N_s}{N_p}\right) = 120\text{ V} \times 0.1732 \approx 20.78\text{ V}.

  5. Compute secondary current: Is=VsRL=20.78 V4.50  Ω≈4.62 AI_s = \frac{V_s}{R_L} = \frac{20.78\text{ V}}{4.50\;\Omega} \approx 4.62\text{ A}.

Final answer

(a) NsNp=0.173\frac{N_s}{N_p} = 0.173 (or 1:5.771:5.77); (b) Is=4.62 AI_s = 4.62\text{ A}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how resistance scales across an ideal transformer by re-deriving Rp=RL(Np/Ns)2R_p = R_L (N_p/N_s)^2 from conservation of energy and voltage ratios.

  • Perform a quick sanity check on all transformer problems: step-down means Vs<VpV_s < V_p, Is>IpI_s > I_p, and Ns<NpN_s < N_p.

Lock it in

Similar question

01

An ideal step-down transformer with primary voltage Vp=240 VV_p = 240\text{ V} and turns ratio NsNp=110\frac{N_s}{N_p} = \frac{1}{10} delivers power to a 6.0  Ω6.0\;\Omega load resistor. Calculate: (a) the secondary voltage VsV_s, (b) the secondary current IsI_s, and (c) the primary current IpI_p.

Answer

(a) Vs=Vp(NsNp)=240⋅110=24 VV_s = V_p \left(\frac{N_s}{N_p}\right) = 240 \cdot \frac{1}{10} = 24\text{ V}. (b) Is=VsR=24 V6.0  Ω=4.0 AI_s = \frac{V_s}{R} = \frac{24\text{ V}}{6.0\;\Omega} = 4.0\text{ A}. (c) Ip=Is(NsNp)=4.0 A⋅110=0.40 AI_p = I_s \left(\frac{N_s}{N_p}\right) = 4.0\text{ A} \cdot \frac{1}{10} = 0.40\text{ A} (or from P=96 WP = 96\text{ W}, Ip=96240=0.40 AI_p = \frac{96}{240} = 0.40\text{ A}).

02

An ideal transformer powers a 12  Ω12\;\Omega speaker connected across its secondary winding. The primary operates at Vp=120 VV_p = 120\text{ V} drawing Ip=0.25 AI_p = 0.25\text{ A}. Determine: (a) the output power delivered to the speaker, (b) the secondary rms current IsI_s, and (c) the turns ratio NsNp\frac{N_s}{N_p}.

Answer

(a) Pout=Pin=VpIp=(120 V)(0.25 A)=30 WP_{\text{out}} = P_{\text{in}} = V_p I_p = (120\text{ V})(0.25\text{ A}) = 30\text{ W}. (b) Pout=Is2R  ⟹  Is=30 W12  Ω=2.5≈1.58 AP_{\text{out}} = I_s^2 R \implies I_s = \sqrt{\frac{30\text{ W}}{12\;\Omega}} = \sqrt{2.5} \approx 1.58\text{ A}. (c) NsNp=IpIs=0.25 A1.581 A≈0.158\frac{N_s}{N_p} = \frac{I_p}{I_s} = \frac{0.25\text{ A}}{1.581\text{ A}} \approx 0.158 (or Vs=IsR=18.97 V  ⟹  NsNp=18.97120≈0.158V_s = I_s R = 18.97\text{ V} \implies \frac{N_s}{N_p} = \frac{18.97}{120} \approx 0.158).

03

A step-up transformer has primary voltage Vp=12 VV_p = 12\text{ V} and delivers 60 W60\text{ W} of power to a resistive load at Vs=120 VV_s = 120\text{ V}. (a) Find the turns ratio NsNp\frac{N_s}{N_p}. (b) Find the primary current IpI_p and secondary current IsI_s. (c) Verify that IsIp=NpNs\frac{I_s}{I_p} = \frac{N_p}{N_s}.

Answer

(a) NsNp=VsVp=120 V12 V=10\frac{N_s}{N_p} = \frac{V_s}{V_p} = \frac{120\text{ V}}{12\text{ V}} = 10. (b) Ip=PVp=60 W12 V=5.0 AI_p = \frac{P}{V_p} = \frac{60\text{ W}}{12\text{ V}} = 5.0\text{ A}; Is=PVs=60 W120 V=0.50 AI_s = \frac{P}{V_s} = \frac{60\text{ W}}{120\text{ V}} = 0.50\text{ A}. (c) IsIp=0.50 A5.0 A=0.10=110=NpNs\frac{I_s}{I_p} = \frac{0.50\text{ A}}{5.0\text{ A}} = 0.10 = \frac{1}{10} = \frac{N_p}{N_s}, confirming current is stepped down when voltage is stepped up.