A structural steel cable of original unstretched length and uniform circular cross-sectional radius supports a suspended load of mass . The Young's modulus of this steel alloy is , and the acceleration due to gravity is . Assuming the cable deforms elastically and neglecting the mass of the cable itself, calculate: (a) the tensile stress developed in the cable, (b) the tensile strain , and (c) the total elongation of the cable in millimeters.
Answer and steps
Final answer
(a) ; (b) ; (c)
Steps
Part (a): Tensile Stress ()
- Calculate the tension force () acting on the cable: The tension in the cable is equal to the gravitational weight of the suspended load:
- Calculate the cross-sectional area () of the cable: Convert the radius to meters: .
- Compute the tensile stress (): Tensile stress is defined as the force applied per unit cross-sectional area: Rounded to three significant figures:
Part (b): Tensile Strain ()
- Relate stress and strain using Hooke's Law: For elastic deformation, stress is proportional to strain via Young's modulus ():
- Calculate the tensile strain (): Rounded to three significant figures: (Note: Strain is a dimensionless quantity representing relative deformation.)
Part (c): Total Elongation ()
- Relate strain to change in length: By definition, tensile strain is the ratio of elongation () to the original unstretched length ():
- Compute the elongation (): Using the strain value:
- Convert to millimeters:
Common Pitfall to Avoid:
- Unit conversions: Forgetting to convert the radius from millimeters to meters before calculating the area leads to an error of several orders of magnitude in both stress and strain.
Typical errors
01 The student treats the given mass as the tension force instead of multiplying by gravitational acceleration, underestimating the tensile stress.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You treated the given mass of directly as a force of . To find the tension supporting a suspended static load, you need to calculate the weight by multiplying mass by gravity: .
- Step 2
- Step 3Correct
Your formula for tensile stress is correct, but your numerical result is smaller by a factor of because it uses your incorrect force from Step 1.
- Step 4Correct
You correctly applied Hooke's law in the form , but the value is affected by the understated stress.
- Step 5Correct
Your definition for elongation and conversion to millimeters are correct, but your final answer is an order of magnitude too small due to the initial force error.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the radius from millimeters to meters before squaring it in the area formula.
You applied the correct definition for tensile stress .
You related stress and strain properly through Young's modulus using .
You correctly converted the calculated elongation from meters to millimeters.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of calculating the weight force .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou conflated mass (, measured in ) with gravitational weight force (, measured in ). When a load is suspended at rest, the upward tension in the cable must balance the downward gravitational force , not simply equal the numerical mass value.
REASONING PATH
Your ACEpath teacher’s suggested approach- Mass to Force Conversion
A suspended static mass exerts a downward weight force of , where .
Always verify units: if a quantity is given in kilograms, multiply by to find the force in newtons before calculating stress.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the gravitational tension force: .
Compute tensile stress: .
Compute tensile strain: .
Compute total elongation: .
(a) ; (b) ; (c)
02 The student forgets to convert the radius from millimeters to meters when finding the cross-sectional area, yielding an incorrect area and stress by a factor of 10⁶.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You used the radius value directly as without converting millimeters to meters (). As a result, the cross-sectional area was overestimated by a factor of .
- Step 3Correct
Your formula and division were carried out properly, but the numerical result is too small because it used the incorrect area from step 2.
- Step 4Correct
You applied Hooke's law correctly to find strain, but the value inherits the error from your stress calculation.
- Step 5Correct
Your formula and unit conversion at the end were completely correct, but the final elongation is off because of the earlier radius conversion error.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the tension force as the gravitational weight of the load.
You used the correct definition of tensile stress as force per unit area.
You correctly applied Hooke's law to relate stress, strain, and Young's modulus.
You correctly related tensile strain to the total elongation and original length.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the radius in millimeters directly into the area formula without converting it to meters first.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking that geometric parameters with prefixes (like ) must be converted to base SI units () before calculating derived quantities (like ), leading to an area error proportional to .
REASONING PATH
Your ACEpath teacher’s suggested approach- Check SI unit compatibility
Pascal is defined as , so all linear dimensions used for cross-sectional area must be in meters ().
Always convert millimeters to meters () before squaring.
- Sanity check physical plausibility
A thin structural steel cable (radius ) carrying nearly experiences significant stress (typically on the order of ) and elongates by a few millimeters.
Compare your calculated stress to ambient pressure or material limits: is unrealistically small for supporting .
CORRECTED PATH
ACEpath Teacher's Demonstration(a) ; (b) ; (c)
03 The student uses the circumference formula 2·π·r instead of the area formula π·r² to compute the cross-sectional area, underestimating the area and overestimating stress.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You applied the circumference formula rather than the circular cross-sectional area formula .
- Step 3Correct
Your definition of tensile stress was correct, but the result is numerically incorrect due to the area calculation error in Step 2.
- Step 4Correct
You correctly applied Hooke's law in the form , but your input stress was carried over from Step 3.
- Step 5Correct
Your elongation formula and your unit conversion to millimeters were executed properly, but the numerical answer inherits the earlier error.
WHAT YOU DID WELL
Compliments from Your TeacherYou calculated the gravitational load accurately.
You properly identified the governing formulas for tensile stress , tensile strain , and elongation .
You converted radius millimeters to meters and final elongation meters to millimeters correctly.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of squaring the radius in .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou conflated the one-dimensional boundary perimeter (circumference ) of a circle with its two-dimensional internal surface area ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Cross-Sectional Area vs. Circumference
Area has units of length squared (). For a solid circular rod or cable, , whereas is the circumference.
Check the power of the radius before computing: an area formula must always contain a squared length term ().
CORRECTED PATH
ACEpath Teacher's DemonstrationCompute the correct circular area: .
Calculate tensile stress: .
Calculate tensile strain: .
Calculate elongation: .
(a) , (b) , (c)
Lock it in
A problem states that a suspended fixture has a mass of . What is the tension force in the vertical support rod?
. Remember: kilograms measure mass; newtons measure force.
Similar question
A brass rod with a circular cross-sectional area of supports a suspended load of mass . Taking , calculate the tensile stress in the rod.
Answer
. Key steps: ; .
An aluminum wire of original length and radius hangs vertically. A mass of is attached to its lower end. If Young's modulus for aluminum is and , determine: (a) the tensile strain , and (b) the elongation in millimeters.
Answer
(a) ; (b) . Key steps: ; ; ; ; .
A steel elevator cable () of length must support a total suspended mass of . If the maximum allowable tensile strain is and , find: (a) the minimum required cross-sectional radius of the cable in millimeters, and (b) the corresponding total elongation in millimeters under this maximum strain.
Answer
(a) ; (b) . Key steps: ; maximum allowable stress ; minimum area ; ; elongation .