Resources
In an analytical physics laboratory experiment, a student determines the electrical conductivity of an unknown cylindrical electrolyte column. The column has an internal diameter and an electrode separation length . A digital multimeter measures a resistance of . Resistance is related to conductivity by , where is the cross-sectional area. (a) Derive the expression for the SI derived unit of electrical conductivity, the siemens per meter (), expressed strictly in SI base units. (b) Compute the conductivity of the electrolyte solution in using the student's experimental data.
Answer and steps
Final answer
(a) (or ); (b)
Steps
Part (a): Expressing Siemens per Meter in SI Base Units
-
Relate electrical quantities to fundamental mechanical and electrical units:
- Current (): The base unit is the ampere ().
- Electric charge (): .
- Potential difference (): Potential difference is the work done per unit charge, . Substituting this into the definition of potential:
- Find the base units of resistance (): Using Ohm's law, :
-
Find the base units of conductance () and conductivity ():
- Conductance in siemens () is the reciprocal of resistance:
- Conductivity has units of siemens per meter ():
Part (b): Calculating Conductivity
-
Convert given values to SI units:
- Length:
- Diameter:
- Resistance:
-
Calculate the cross-sectional area :
Pitfall: A common error is squaring the diameter without dividing by (or forgetting to convert centimeters to meters before squaring).
- Rearrange the resistance formula and solve for : Substitute the numerical values:
To three significant figures, the conductivity is .
Typical errors
01 The student uses diameter instead of radius when calculating the cross-sectional area, resulting in an area that is four times too large and an underestimated conductivity.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You used instead of . When given diameter , you must either divide by first to get radius or divide by .
- Step 3Correct
Your calculation correctly followed your rearranged formula , but the numerical value was divided by an area that was four times too large.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly rearranged the resistance formula for conductivity as .
You accurately tracked and derived the base SI units for potential, resistance, and conductivity.
You correctly converted centimeters to meters for both length and diameter.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou substituted diameter directly into the area formula as , omitting the factor of (or failing to divide the diameter by to obtain radius).
REASONING PATH
Your ACEpath teacher’s suggested approach- Area from Diameter
A circle's area is .
Whenever a problem provides a diameter , immediately write before calculating area, or explicitly write .
CORRECTED PATH
ACEpath Teacher's DemonstrationRecalculate cross-sectional area with the correct formula: .
Substitute into : .
Compute the final numerical quotient: .
(a) ; (b)
02 The student forgets to convert centimeters to meters, resulting in area and length values that are off by powers of ten.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You substituted and without converting them into standard SI units (meters and square meters). Evaluating yields conductivity in , not the requested .
- Step 3Correct
Your arithmetic on the substituted numbers was carried out properly, but because the input dimensions were in centimeters, your result represents , which equals .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly related electrical resistance to potential difference, current, work, and charge to derive the SI base units.
You correctly identified and applied the formula relating conductivity, length, cross-sectional area, and resistance.
You correctly computed the cylinder radius from the diameter and calculated the cross-sectional area with proper geometry.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou substituted dimensioned geometric measurements in centimeters and square centimeters directly into an equation expecting SI base units (meters), leading to an unscaled conductivity in labeled as .
REASONING PATH
Your ACEpath teacher’s suggested approach- Convert Inputs to Standard SI Units First
Derived physical formulas with SI outputs require base SI inputs: length must be in and area in .
Always convert all geometric quantities to meters before computing area and substituting into physical formulas.
- Area Unit Scaling Factor
, not .
When converting areas or volumes, square or cube the linear conversion factor explicitly.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert diameter and length to meters: (so ) and .
Compute cross-sectional area in SI units: .
Substitute into : .
(a) ; (b)
03 The student misinverts the definition formula and solves for conductivity as σ = R A / L instead of σ = L / (R A).
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You wrote instead of . Although you rearranged correctly in part (a), you accidentally inverted the formula in part (b) (which corresponds to resistivity , rather than conductivity ).
- Step 4Correct
Your numerical computation followed directly from your inverted formula in Step 3, yielding .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly derived the SI base units of conductivity as .
You converted all given values into standard SI units before calculating.
You correctly calculated the cross-sectional area from the column's diameter.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou correctly isolated in part (a), but inadvertently switched it to when plugging in numbers for part (b).
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing conductivity with resistivity , or making an algebraic transposition error when setting up the substitution step.
REASONING PATH
Your ACEpath teacher’s suggested approach- Conductivity vs. Resistivity
Conductivity is the reciprocal of resistivity: . Since , solving for gives .
Check that the length stays in the numerator and resistance stays in the denominator whenever you solve for conductivity .
CORRECTED PATH
ACEpath Teacher's DemonstrationSubstitute the values into the correct formula:
Lock it in
How are radius and diameter related in the area formula for a circular cross-section?
. If you write , your area is 4 times too large.
Similar question
A cylindrical copper wire has diameter and length . The measured resistance is . Calculate the electrical conductivity of the copper in .
Answer
. Cross-sectional area . Conductivity .
An electrolyte tube of length has an inner circular cross-section with diameter . If the solution has conductivity , what resistance will be measured across the ends?
Answer
Convert to SI units: , . Cross-sectional area . Resistance ().
Derive the SI base unit expression for electrical resistivity and verify its dimensional consistency with the resistance relation .
Answer
Resistivity is the reciprocal of conductivity: (or ). Checking with : , which equals .