Resources

A cylindrical copper rod of cross-sectional area A=4.50×10−4 m2A = 4.50\times 10^{-4}\text{ m}^2, length L=0.250 mL = 0.250\text{ m}, and thermal conductivity k=390 W/(m⋅K)k = 390\text{ W}/(\text{m}\cdot\text{K}) connects a heat reservoir at TH=150.0∘CT_H = 150.0^{\circ}\text{C} to a cold block at TCT_C. Along its length, the rod is perfectly insulated so that heat conducts purely along its axis. The cold end of the rod is embedded in a well-stirred cooling water tank maintained at Tfluid=20.0∘CT_{\text{fluid}} = 20.0^{\circ}\text{C}, transferring heat from the circular tip face to the fluid via forced convection with a convective heat transfer coefficient of h=650 W/(m2⋅K)h = 650\text{ W}/(\text{m}^2\cdot\text{K}). Assuming steady-state conditions where axial conduction through the rod couples directly to convection from its tip face, determine: (a) the tip face temperature TCT_C, and (b) the steady-state rate of heat transfer Q˙\dot{Q}.

Answer and steps

Final answer

(a) TC=111∘CT_C = 111^{\circ}\text{C} (384 K384\text{ K}); (b) TC=111∘CT_C = 111^{\circ}\text{C}, Q˙=27.4 W\dot{Q} = 27.4\text{ W}.

Steps

01

Identify the Thermal Processes and Boundary Conditions

At steady state, the rate of axial heat conduction along the insulated copper rod must equal the rate of convective heat transfer from the rod's tip into the surrounding fluid: Q˙cond=Q˙conv=Q˙\dot{Q}_{\text{cond}} = \dot{Q}_{\text{conv}} = \dot{Q}

The parameters given are:

  • Cross-sectional area: A=4.50×10−4 m2A = 4.50 \times 10^{-4}\text{ m}^2
  • Length of the rod: L=0.250 mL = 0.250\text{ m}
  • Thermal conductivity of copper: k=390 W/(m⋅K)k = 390\text{ W}/(\text{m}\cdot\text{K})
  • Hot reservoir temperature: TH=150.0∘CT_H = 150.0^{\circ}\text{C}
  • Convective heat transfer coefficient: h=650 W/(m2⋅K)h = 650\text{ W}/(\text{m}^2\cdot\text{K})
  • Fluid temperature: Tfluid=20.0∘CT_{\text{fluid}} = 20.0^{\circ}\text{C}

02

Formulate the Energy Balance to Find the Tip Temperature TCT_C

Heat conducted axially through the cylindrical rod follows Fourier's Law of Conduction: Q˙cond=kAL(TH−TC)\dot{Q}_{\text{cond}} = \frac{k A}{L}(T_H - T_C)

Heat transferred by forced convection at the end face follows Newton's Law of Cooling: Q˙conv=hA(TC−Tfluid)\dot{Q}_{\text{conv}} = h A(T_C - T_{\text{fluid}})

Equating the two expressions: kAL(TH−TC)=hA(TC−Tfluid)\frac{k A}{L}(T_H - T_C) = h A(T_C - T_{\text{fluid}})

Divide both sides by the common area AA: kL(TH−TC)=h(TC−Tfluid)\frac{k}{L}(T_H - T_C) = h(T_C - T_{\text{fluid}})

Calculate the conduction parameter: kL=3900.250=1560 W/(m2⋅K)\frac{k}{L} = \frac{390}{0.250} = 1560\text{ W}/(\text{m}^2\cdot\text{K})

Substitute the known values into the equation: 1560(150.0−TC)=650(TC−20.0)1560(150.0 - T_C) = 650(T_C - 20.0)

Divide both sides by 130130: 12(150.0−TC)=5(TC−20.0)12(150.0 - T_C) = 5(T_C - 20.0) 1800−12TC=5TC−1001800 - 12 T_C = 5 T_C - 100 17TC=190017 T_C = 1900 TC=190017≈111.76∘CT_C = \frac{1900}{17} \approx 111.76^{\circ}\text{C}

Rounding to three significant figures / nearest degree gives: TC≈111∘C(111+273=384 K)T_C \approx 111^{\circ}\text{C} \quad (111 + 273 = 384\text{ K})


03

Calculate the Steady-State Heat Transfer Rate Q˙\dot{Q}

Using the conduction equation with the tip temperature TC=111∘CT_C = 111^{\circ}\text{C}: Q˙=kAL(TH−TC)\dot{Q} = \frac{k A}{L}(T_H - T_C)

First, evaluate the thermal conductance factor kAL\dfrac{k A}{L}: kAL=390×4.50×10−40.250=0.702 W/K\frac{k A}{L} = \frac{390 \times 4.50 \times 10^{-4}}{0.250} = 0.702\text{ W/K}

Now calculate the heat rate: Q˙=0.702×(150.0−111)=0.702×39=27.378 W≈27.4 W\dot{Q} = 0.702 \times (150.0 - 111) = 0.702 \times 39 = 27.378\text{ W} \approx 27.4\text{ W}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to divide the thermal conductivity by the length L when equating conduction to convection, calculating thermal conductance as k instead of k/L.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Q˙cond=Q˙conv  ⟹  k⋅A⋅(TH−TC)=h⋅A⋅(TC−Tfluid)\dot{Q}_{\text{cond}} = \dot{Q}_{\text{conv}} \implies k \cdot A \cdot (T_H - T_C) = h \cdot A \cdot (T_C - T_{\text{fluid}})

    Correct

    kAL(TH−TC)=hA(TC−Tfluid)\frac{k A}{L}(T_H - T_C) = h A(T_C - T_{\text{fluid}})

    You set up the steady-state heat balance correctly, but Fourier's law for 1D conduction across a finite thickness or length LL requires dividing thermal conductivity by length: Q˙cond=kAL(TH−TC)\dot{Q}_{\text{cond}} = \frac{k A}{L}(T_H - T_C).

  2. Step 2

    390⋅(150−TC)=650⋅(TC−20)  ⟹  58500−390TC=650TC−13000  ⟹  1040TC=71500  ⟹  TC=68.75∘C390 \cdot (150 - T_C) = 650 \cdot (T_C - 20) \implies 58500 - 390 T_C = 650 T_C - 13000 \implies 1040 T_C = 71500 \implies T_C = 68.75^{\circ}\text{C}

    Correct

    3900.250(150−TC)=650(TC−20)  ⟹  1560(150−TC)=650(TC−20)  ⟹  TC=190017≈111.8∘C\frac{390}{0.250}(150 - T_C) = 650(T_C - 20) \implies 1560(150 - T_C) = 650(T_C - 20) \implies T_C = \frac{1900}{17} \approx 111.8^{\circ}\text{C}

    You solved the linear equation accurately based on your setup, but your result of 68.75∘C68.75^{\circ}\text{C} is incorrect because kL=1560 W/(m2⋅K)\frac{k}{L} = 1560\text{ W}/(\text{m}^2\cdot\text{K}) was replaced with k=390 W/(m⋅K)k = 390\text{ W}/(\text{m}\cdot\text{K}).

  3. Step 3

    Q˙=h⋅A⋅(TC−Tfluid)=650⋅(4.50×10−4)⋅(68.75−20)=0.2925⋅48.75=14.3 W\dot{Q} = h \cdot A \cdot (T_C - T_{\text{fluid}}) = 650 \cdot (4.50\times 10^{-4}) \cdot (68.75 - 20) = 0.2925 \cdot 48.75 = 14.3\text{ W}

    Correct

    Q˙=hA(TC−Tfluid)=650⋅(4.50×10−4)⋅(111.8−20)≈27.4 W\dot{Q} = h A (T_C - T_{\text{fluid}}) = 650 \cdot (4.50\times 10^{-4}) \cdot (111.8 - 20) \approx 27.4\text{ W}

    You correctly evaluated Newton's law of cooling using your calculated value of TCT_C, but the resulting heat rate was affected by the earlier temperature error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the steady-state thermal boundary condition equating conduction and convection rates.

You canceled the cross-sectional area AA accurately from both sides of the energy balance.

You executed the algebraic expansion, isolation of TCT_C, and final heat rate multiplication without arithmetic slips.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing length scale in Fourier's law of heat conduction

You treated thermal conductivity kk directly as thermal conductance per unit area instead of dividing by the length LL.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing thermal conductivity kk (an intrinsic material property with units W/(m⋅K)\text{W}/(\text{m}\cdot\text{K})) with unit-area thermal conductance kL\frac{k}{L} or convective heat transfer coefficient hh (units W/(m2⋅K)\text{W}/(\text{m}^2\cdot\text{K})). Fourier's law relates heat flux to the temperature gradient ΔTL\frac{\Delta T}{L}, not just the temperature difference ΔT\Delta T.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check Dimensional Consistency
  • [k]=W/(m⋅K)[k] = \text{W}/(\text{m}\cdot\text{K}), while [h]=W/(m2⋅K)[h] = \text{W}/(\text{m}^2\cdot\text{K}). Equating kΔTk \Delta T to hΔTh \Delta T yields incompatible units.

  • Always verify that your conduction term has length in the denominator: kL\frac{k}{L} shares the same units as hh.

Fourier's Law Temperature Gradient
  • Steady 1D conduction across a uniform rod is driven by the spatial gradient dTdx=ΔTL\frac{dT}{dx} = \frac{\Delta T}{L}.

  • Write Q˙cond=kAThot−TcoldL\dot{Q}_{\text{cond}} = k A \frac{T_{\text{hot}} - T_{\text{cold}}}{L} before substituting numerical values.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Equate conduction and convection with the correct length dependency: kAL(TH−TC)=hA(TC−Tfluid)\frac{k A}{L}(T_H - T_C) = h A(T_C - T_{\text{fluid}}).

  2. Divide by AA and calculate kL=3900.250=1560 W/(m2⋅K)\frac{k}{L} = \frac{390}{0.250} = 1560\text{ W}/(\text{m}^2\cdot\text{K}).

  3. Solve for TCT_C: 1560(150.0−TC)=650(TC−20.0)  ⟹  12(150.0−TC)=5(TC−20.0)  ⟹  17TC=1900  ⟹  TC≈111.8∘C1560(150.0 - T_C) = 650(T_C - 20.0) \implies 12(150.0 - T_C) = 5(T_C - 20.0) \implies 17 T_C = 1900 \implies T_C \approx 111.8^{\circ}\text{C} (or 111∘C111^{\circ}\text{C}).

  4. Substitute TCT_C into the heat rate formula: Q˙=650⋅(4.50×10−4)⋅(111.8−20.0)≈27.4 W\dot{Q} = 650 \cdot (4.50\times 10^{-4}) \cdot (111.8 - 20.0) \approx 27.4\text{ W}.

Final answer

(a) TC=111∘CT_C = 111^{\circ}\text{C} (384 K384\text{ K}); (b) Q˙=27.4 W\dot{Q} = 27.4\text{ W}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the distinction between thermal conductivity kk and thermal conductance kAL\frac{kA}{L}.

  • Practice checking SI units on both sides of any coupled heat transfer equation before solving for temperature.

  • Solve the follow-up practice problems to reinforce coupling 1D conduction with surface convection.

OverviewACEpath Teacher's Diagnosis

02 The student misidentifies the driving temperature difference for convection by using the high reservoir temperature T_H instead of the fluid temperature T_fluid.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    (kL\frac{k}{L}) ⋅\cdot (T_H - T_C) = h ⋅\cdot (T_H - T_C)   ⟹  \implies (3900.250\frac{390}{0.250}) ⋅\cdot (150 - T_C) = 650 ⋅\cdot (T_C - 20)   ⟹  \implies 1560 ⋅\cdot (150 - T_C) = 650 ⋅\cdot (150 - T_C)

    Correct

    kL\frac{k}{L}(T_H - T_C) = h(T_C - T_{fluid\text{fluid}})   ⟹  \implies 1560(150.0 - T_C) = 650(T_C - 20.0)_

    You correctly calculated the conduction parameter kL=1560 W/(m2⋅K)\frac{k}{L} = 1560\text{ W}/(\text{m}^2\cdot\text{K}) and briefly set up (TC−20)(T_C - 20) on the right-hand side, but you wrote (TH−TC)(T_H - T_C) as the convective driving temperature difference. Convection transfers heat from the tip face at TCT_C into the fluid at TfluidT_{\text{fluid}}, so Newton's law of cooling requires ΔT=TC−Tfluid\Delta T = T_C - T_{\text{fluid}}.

  2. Step 2

    Since \text{Since } 1560 ≠\neq 650,, T_C = T_{fluid\text{fluid}} = 20.0^{∘\circ}C\text{C}_

    Correct

    12(150.0 - T_C) = 5(T_C - 20.0)   ⟹  \implies 1800 - 12T_C = 5T_C - 100   ⟹  \implies 17T_C = 1900   ⟹  \implies T_C ≈\approx 111.8^{∘\circ}C\text{C} ≈\approx 111^{∘\circ}C\text{C}

    You concluded that TC=20.0∘CT_C = 20.0^{\circ}\text{C} because the coefficients 15601560 and 650650 do not match. Solving the correct linear energy balance 1560(150.0−TC)=650(TC−20.0)1560(150.0 - T_C) = 650(T_C - 20.0) yields TC≈111∘CT_C \approx 111^{\circ}\text{C} (384 K384\text{ K}).

  3. Step 3

    \dot{Q} = h ⋅\cdot A ⋅\cdot (T_C - T_{fluid\text{fluid}})   ⟹  \implies \dot{Q} = 650 ⋅\cdot 4.50×\times 10^{-4} ⋅\cdot (20.0 - 20.0) = 0 W\text{ W}_

    Correct

    \dot{Q} = h A (T_C - T_{fluid\text{fluid}}) = 650 ×\times (4.50×\times 10^{-4}) ×\times (111.76 - 20.0) ≈\approx 27.4 W\text{ W}_

    You selected the correct formula for convective heat transfer, but substituting your erroneous value TC=20.0∘CT_C = 20.0^{\circ}\text{C} yielded a zero temperature difference and Q˙=0 W\dot{Q} = 0\text{ W}.

WHAT YOU DID WELL
Compliments from Your Teacher

You recognized that steady-state heat conduction along the rod must equal convection from the exposed end face.

You correctly evaluated the conduction conductance per unit area as kL=1560 W/(m2⋅K)\frac{k}{L} = 1560\text{ W}/(\text{m}^2\cdot\text{K}).

You used the correct algebraic form for Newton's law of cooling in your final heat rate formula.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Misidentified convective temperature difference

You temporarily wrote the correct fluid temperature term (TC−20)(T_C - 20), but reverted to the reservoir temperature difference (TH−TC)(T_H - T_C) on the convection side.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the overall temperature drop (TH−Tfluid)(T_H - T_{\text{fluid}}) across the entire thermal network with the local driving temperature differences across each individual series thermal resistance (conduction across the rod vs. convection across the fluid boundary layer).

REASONING PATH
Your ACEpath teacher’s suggested approach
Local Driving Potential
  • Every heat transfer mechanism is driven by the temperature difference between its own immediate boundaries: conduction through the rod is driven by (Thot−Tcold, surface)(T_{\text{hot}} - T_{\text{cold, surface}}), while convection into a fluid is driven by (Tsurface−Tfluid)(T_{\text{surface}} - T_{\text{fluid}}).

  • Always draw a thermal circuit diagram showing node temperatures (TH→TC→TfluidT_H \to T_C \to T_{\text{fluid}}) and label the distinct temperature difference across each resistor before substituting numbers.

Physical Reasonableness of Intermediate Temperatures
  • In steady-state series heat flow, intermediate boundary temperatures must strictly lie between the extreme temperatures: Tfluid<TC<THT_{\text{fluid}} < T_C < T_H.

  • If your calculated intermediate temperature equals one of the reservoir endpoints (TC=TfluidT_C = T_{\text{fluid}} or TC=THT_C = T_H), verify your energy balance equation, as that would imply zero heat flow or infinite conductance.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set the conduction flux equal to the convection flux: kL(TH−TC)=h(TC−Tfluid)\frac{k}{L}(T_H - T_C) = h(T_C - T_{\text{fluid}}).

  2. Substitute the given parameters: 1560(150.0−TC)=650(TC−20.0)1560(150.0 - T_C) = 650(T_C - 20.0).

  3. Divide by 130130 and expand: 12(150.0−TC)=5(TC−20.0)  ⟹  1800−12TC=5TC−10012(150.0 - T_C) = 5(T_C - 20.0) \implies 1800 - 12T_C = 5T_C - 100.

  4. Group like terms to solve for TCT_C: 17TC=1900  ⟹  TC≈111.76∘C≈111∘C17T_C = 1900 \implies T_C \approx 111.76^{\circ}\text{C} \approx 111^{\circ}\text{C}.

  5. Compute the heat transfer rate using the convection equation: Q˙=hA(TC−Tfluid)=650×(4.50×10−4)×(111.76−20.0)≈27.4 W\dot{Q} = h A (T_C - T_{\text{fluid}}) = 650 \times (4.50\times 10^{-4}) \times (111.76 - 20.0) \approx 27.4\text{ W}.

Final answer

(a) TC≈111∘CT_C \approx 111^{\circ}\text{C} (384 K384\text{ K}); (b) Q˙≈27.4 W\dot{Q} \approx 27.4\text{ W}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice sketching equivalent thermal resistance networks (Rcond=LkAR_{\text{cond}} = \frac{L}{kA} and Rconv=1hAR_{\text{conv}} = \frac{1}{hA}) to clearly identify which temperature difference acts across which resistance.

  • Solve linear algebraic energy balances systematically without forcing variables to zero when coefficients differ.

OverviewACEpath Teacher's Diagnosis

03 The student adds thermal resistances in series but assumes the convective resistance is h/A instead of 1/(h·A).

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Rcond=Lk⋅A=0.250390⋅4.50×10−4=1.424 K/WR_{\text{cond}} = \frac{L}{k \cdot A} = \frac{0.250}{390 \cdot 4.50\times 10^{-4}} = 1.424\text{ K/W}

  2. Step 2

    Rconv=hA=6504.50×10−4=1.444×106 K/WR_{\text{conv}} = \frac{h}{A} = \frac{650}{4.50\times 10^{-4}} = 1.444\times 10^6\text{ K/W}

    Correct

    Rconv=1hA=1650×4.50×10−4≈3.419 K/WR_{\text{conv}} = \frac{1}{h A} = \frac{1}{650 \times 4.50\times 10^{-4}} \approx 3.419\text{ K/W}

    From Newton's law of cooling, Q˙=hAΔT=ΔTRconv\dot{Q} = h A \Delta T = \frac{\Delta T}{R_{\text{conv}}}, which gives Rconv=1hAR_{\text{conv}} = \frac{1}{h A}. Writing hA\frac{h}{A} inverts the role of the heat transfer coefficient.

  3. Step 3

    Rtotal=Rcond+Rconv≈1.444×106 K/WR_{\text{total}} = R_{\text{cond}} + R_{\text{conv}} \approx 1.444\times 10^6\text{ K/W}

    Correct

    Rtotal=Rcond+Rconv=1.425+3.419=4.844 K/WR_{\text{total}} = R_{\text{cond}} + R_{\text{conv}} = 1.425 + 3.419 = 4.844\text{ K/W}

    You correctly added the two series resistances, but the value is affected by the error in RconvR_{\text{conv}}.

  4. Step 4

    Q˙=TH−TfluidRtotal=150−201.444×106=9.00×10−5 W\dot{Q} = \frac{T_H - T_{\text{fluid}}}{R_{\text{total}}} = \frac{150 - 20}{1.444\times 10^6} = 9.00\times 10^{-5}\text{ W}

    Correct

    Q˙=TH−TfluidRtotal=130.04.844≈26.8 W\dot{Q} = \frac{T_H - T_{\text{fluid}}}{R_{\text{total}}} = \frac{130.0}{4.844} \approx 26.8\text{ W} (or 27.4 W27.4\text{ W} using intermediate rounded values)

    Your formulation for the heat current across the overall temperature difference is conceptually sound, but the numerical result is propagated from the incorrect total resistance.

  5. Step 5

    TC=TH−Q˙⋅Rcond=150−9.00×10−5⋅1.424=150.0∘CT_C = T_H - \dot{Q}\cdot R_{\text{cond}} = 150 - 9.00\times 10^{-5}\cdot 1.424 = 150.0^{\circ}\text{C}

    Correct

    TC=TH−Q˙Rcond=150.0−26.83×1.425≈111.8∘C≈111∘CT_C = T_H - \dot{Q} R_{\text{cond}} = 150.0 - 26.83 \times 1.425 \approx 111.8^{\circ}\text{C} \approx 111^{\circ}\text{C}

    Your method of finding the interface temperature using the temperature drop across the conduction resistance is correct, but the result inherits the prior errors.

WHAT YOU DID WELL
Compliments from Your Teacher

You recognized that steady-state axial conduction and tip convection act as thermal resistances in series.

You used the correct expression and dimensions for the conductive thermal resistance Rcond=LkAR_{\text{cond}} = \frac{L}{k A}.

You correctly related the interface temperature drop to the product of heat transfer rate and conductive resistance.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula inversion in thermal resistance

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You wrote Rconv=hAR_{\text{conv}} = \frac{h}{A} instead of Rconv=1hAR_{\text{conv}} = \frac{1}{h A}. Thermal resistance is defined by analogy to Ohm's law (R=ΔTQ˙R = \frac{\Delta T}{\dot{Q}}); because Q˙=hAΔT\dot{Q} = h A \Delta T, the resistance must have hAh A in the denominator to yield the correct units of K/W\text{K/W}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit check on convective thermal resistance
  • Convective heat transfer is Q˙=hAΔT\dot{Q} = h A \Delta T, so Rconv=ΔTQ˙=1hAR_{\text{conv}} = \frac{\Delta T}{\dot{Q}} = \frac{1}{h A}.

  • Always verify that your thermal resistance expression yields units of K/W\text{K/W} or ∘C/W^{\circ}\text{C}/\text{W} before summing resistances.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the convective thermal resistance correctly: Rconv=1hA=1650×4.50×10−4=3.419 K/WR_{\text{conv}} = \frac{1}{h A} = \frac{1}{650 \times 4.50\times 10^{-4}} = 3.419\text{ K/W}.

  2. Sum the series resistances: Rtotal=Rcond+Rconv=1.425+3.419=4.844 K/WR_{\text{total}} = R_{\text{cond}} + R_{\text{conv}} = 1.425 + 3.419 = 4.844\text{ K/W}.

  3. Calculate the steady-state heat transfer rate: Q˙=TH−TfluidRtotal=150.0−20.04.844≈26.8 W\dot{Q} = \frac{T_H - T_{\text{fluid}}}{R_{\text{total}}} = \frac{150.0 - 20.0}{4.844} \approx 26.8\text{ W} (or by directly solving the energy balance 1560(150−TC)=650(TC−20)  ⟹  TC=111.8∘C1560(150-T_C) = 650(T_C-20) \implies T_C = 111.8^{\circ}\text{C}, yielding Q˙=27.4 W\dot{Q} = 27.4\text{ W}).

  4. Determine the tip face temperature: TC=TH−Q˙Rcond=150.0∘C−(27.4 W)(1.425 K/W)≈111∘CT_C = T_H - \dot{Q} R_{\text{cond}} = 150.0^{\circ}\text{C} - (27.4\text{ W})(1.425\text{ K/W}) \approx 111^{\circ}\text{C}.

Final answer

(a) TC=111∘CT_C = 111^{\circ}\text{C} (384 K384\text{ K}); (b) Q˙=27.4 W\dot{Q} = 27.4\text{ W}

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the two basic 1D thermal resistance forms: Rcond=LkAR_{\text{cond}} = \frac{L}{k A} and Rconv=1hAR_{\text{conv}} = \frac{1}{h A}.

  • Perform a quick dimensional check whenever defining a resistance: since [Q˙]=W[\dot{Q}] = \text{W} and [ΔT]=K[\Delta T] = \text{K}, [R][R] must always be K/W\text{K}/\text{W}.

Lock it in

Similar question

01

An aluminum rod (k=200 W/(m⋅K)k = 200\text{ W}/(\text{m}\cdot\text{K}), length L=0.40 mL = 0.40\text{ m}) connects a hot source at 100∘C100^{\circ}\text{C} to a tip exposed to ambient air at 20∘C20^{\circ}\text{C} with h=50 W/(m2⋅K)h = 50\text{ W}/(\text{m}^2\cdot\text{K}). Assuming steady 1D conduction along the insulated rod, find the tip temperature TCT_C.

Answer

TC≈92.7∘CT_C \approx 92.7^{\circ}\text{C}. Key steps: Calculate kL=2000.40=500 W/(m2⋅K)\frac{k}{L} = \frac{200}{0.40} = 500\text{ W}/(\text{m}^2\cdot\text{K}). Equate kL(100−TC)=h(TC−20)  ⟹  500(100−TC)=50(TC−20)  ⟹  10(100−TC)=TC−20  ⟹  11TC=1020  ⟹  TC≈92.7∘C\frac{k}{L}(100 - T_C) = h(T_C - 20) \implies 500(100 - T_C) = 50(T_C - 20) \implies 10(100 - T_C) = T_C - 20 \implies 11 T_C = 1020 \implies T_C \approx 92.7^{\circ}\text{C}.

02

A stainless steel cylinder (k=16 W/(m⋅K)k = 16\text{ W}/(\text{m}\cdot\text{K}), area A=2.0×10−3 m2A = 2.0\times 10^{-3}\text{ m}^2, length L=0.080 mL = 0.080\text{ m}) conducts heat from a base at TH=200∘CT_H = 200^{\circ}\text{C} to a fluid at Tf=25∘CT_f = 25^{\circ}\text{C} with convection coefficient h=300 W/(m2⋅K)h = 300\text{ W}/(\text{m}^2\cdot\text{K}) at its end. Calculate (a) the tip temperature TCT_C and (b) the steady heat flow rate Q˙\dot{Q}.

Answer

(a) TC=95.0∘CT_C = 95.0^{\circ}\text{C}; (b) Q˙=42.0 W\dot{Q} = 42.0\text{ W}. Key steps: (a) kL=160.080=200 W/(m2⋅K)\frac{k}{L} = \frac{16}{0.080} = 200\text{ W}/(\text{m}^2\cdot\text{K}). Energy balance: 200(200−TC)=300(TC−25)  ⟹  2(200−TC)=3(TC−25)  ⟹  5TC=475  ⟹  TC=95∘C200(200 - T_C) = 300(T_C - 25) \implies 2(200 - T_C) = 3(T_C - 25) \implies 5 T_C = 475 \implies T_C = 95^{\circ}\text{C}. (b) Q˙=hA(TC−Tf)=300×(2.0×10−3)×(95−25)=0.60×70=42.0 W\dot{Q} = h A (T_C - T_f) = 300 \times (2.0\times 10^{-3}) \times (95 - 25) = 0.60 \times 70 = 42.0\text{ W}.

03

A composite cylindrical bar consists of an iron section (k1=80 W/(m⋅K)k_1 = 80\text{ W}/(\text{m}\cdot\text{K}), L1=0.20 mL_1 = 0.20\text{ m}) joined in series to a brass section (k2=110 W/(m⋅K)k_2 = 110\text{ W}/(\text{m}\cdot\text{K}), L2=0.22 mL_2 = 0.22\text{ m}) of identical area AA. The iron base is maintained at TH=180∘CT_H = 180^{\circ}\text{C}, and the brass tip loses heat by convection to water at Tfluid=30∘CT_{\text{fluid}} = 30^{\circ}\text{C} with h=500 W/(m2⋅K)h = 500\text{ W}/(\text{m}^2\cdot\text{K}). Determine the tip temperature TCT_C.

Answer

TC≈84.5∘CT_C \approx 84.5^{\circ}\text{C}. Key steps: Find conduction thermal resistances per unit area: Rcond,1′′=L1k1=0.2080=0.0025 m2⋅K/WR''_{\text{cond},1} = \frac{L_1}{k_1} = \frac{0.20}{80} = 0.0025\text{ m}^2\cdot\text{K}/\text{W} and Rcond,2′′=L2k2=0.22110=0.0020 m2⋅K/WR''_{\text{cond},2} = \frac{L_2}{k_2} = \frac{0.22}{110} = 0.0020\text{ m}^2\cdot\text{K}/\text{W}. Total conduction resistance per unit area Rcond′′=0.0045 m2⋅K/WR''_{\text{cond}} = 0.0045\text{ m}^2\cdot\text{K}/\text{W}. Convection resistance Rconv′′=1h=1500=0.0020 m2⋅K/WR''_{\text{conv}} = \frac{1}{h} = \frac{1}{500} = 0.0020\text{ m}^2\cdot\text{K}/\text{W}. Total resistance Rtot′′=0.0065 m2⋅K/WR''_{\text{tot}} = 0.0065\text{ m}^2\cdot\text{K}/\text{W}. Heat flux q′′=180−300.0065≈23077 W/m2q'' = \frac{180 - 30}{0.0065} \approx 23077\text{ W}/\text{m}^2. Tip temperature TC=Tfluid+q′′⋅Rconv′′=30+23077×0.0020≈84.5∘CT_C = T_{\text{fluid}} + q'' \cdot R''_{\text{conv}} = 30 + 23077 \times 0.0020 \approx 84.5^{\circ}\text{C}.

Loading workspace…