A standard thermodynamic refrigeration cycle is analyzed using the Clausius statement sign convention, where all energy transfers into the working fluid are positive and all energy transfers out of the fluid are negative. The system extracts heat from a cold freezer compartment, absorbs work from an electric motor, and expels heat to the room. The measured magnitudes are ∣QC∣=3.60×103 J|Q_C| = 3.60 \times 10^3\text{ J} and ∣Win∣=9.00×102 J|W_{\text{in}}| = 9.00 \times 10^2\text{ J}. (a) Assign the proper algebraic signs to QCQ_C, WnetW_{\text{net}}, and QHQ_H from the perspective of the working fluid. (b) Write the First Law of Thermodynamics relation ΔUcycle=Qnet−Wfluid\Delta U_{\text{cycle}} = Q_{\text{net}} - W_{\text{fluid}} for a complete closed cycle and solve for the signed quantity QHQ_H. (c) Compute the coefficient of performance COPref\text{COP}_{\text{ref}} using absolute energy magnitudes.

Answer and steps

Final answer

(a) QC=+3.60×103 JQ_C = +3.60 \times 10^3\text{ J}, Wfluid=−9.00×102 JW_{\text{fluid}} = -9.00 \times 10^2\text{ J} (meaning work done on fluid is Win=+9.00×102 JW_{\text{in}} = +9.00 \times 10^2\text{ J}), QH=−4.50×103 JQ_H = -4.50 \times 10^3\text{ J}; (b) ΔUcycle=0  ⟹  QC+QH−Wfluid=0\Delta U_{\text{cycle}} = 0 \implies Q_C + Q_H - W_{\text{fluid}} = 0, giving QH=−4.50×103 JQ_H = -4.50 \times 10^3\text{ J}; (c) COPref=4.00\text{COP}_{\text{ref}} = 4.00.

Steps

Part (a): Assigning Algebraic Signs

The standard sign convention in thermodynamics treats energy entering the working fluid as positive (>0> 0) and energy leaving the working fluid as negative (<0< 0):

  1. Heat absorbed from the cold space (QCQ_C): Heat enters the working fluid from the cold reservoir (the freezer compartment): QC=+3.60×103 JQ_C = +3.60 \times 10^3\text{ J}
  2. Work interaction (WfluidW_{\text{fluid}}): Work is done on the working fluid by an external motor (∣Win∣=9.00×102 J|W_{\text{in}}| = 9.00 \times 10^2\text{ J}). Since work done by the fluid represents energy leaving the fluid: Wfluid=−∣Win∣=−9.00×102 JW_{\text{fluid}} = -|W_{\text{in}}| = -9.00 \times 10^2\text{ J}
  3. Heat expelled to the warm room (QHQ_H): Heat leaves the working fluid to the surroundings at higher temperature. Therefore, QHQ_H must carry a negative sign: QH<0Q_H < 0 (Its magnitude is calculated in Part (b).)

Part (b): First Law Analysis for a Full Cycle

Because internal energy UU is a thermodynamic state function, the net change in internal energy over any complete, closed cycle is zero: ΔUcycle=0\Delta U_{\text{cycle}} = 0

Applying the First Law of Thermodynamics, ΔU=Qnet−Wfluid\Delta U = Q_{\text{net}} - W_{\text{fluid}}: 0=(QC+QH)−Wfluid0 = (Q_C + Q_H) - W_{\text{fluid}}

Rearranging to solve for QHQ_H: QH=Wfluid−QCQ_H = W_{\text{fluid}} - Q_C

Substitute the signed values: QH=(−9.00×102 J)−(3.60×103 J)=−4.50×103 JQ_H = (-9.00 \times 10^2\text{ J}) - (3.60 \times 10^3\text{ J}) = -4.50 \times 10^3\text{ J}

The negative sign confirms that 4.50×103 J4.50 \times 10^3\text{ J} of thermal energy is rejected by the fluid into the warm room.

Common Pitfall: Forgetting the definition of work used in the First Law equation. If using ΔU=Q−W\Delta U = Q - W, WW is the work done by the system. When work is put into the system, Wby=−WinW_{\text{by}} = -W_{\text{in}}. Alternatively, writing the energy balance directly as ∑Ein=∑Eout\sum E_{\text{in}} = \sum E_{\text{out}} yields ∣QC∣+∣Win∣=∣QH∣|Q_C| + |W_{\text{in}}| = |Q_H|, which confirms the magnitude ∣QH∣=4.50×103 J|Q_H| = 4.50 \times 10^3\text{ J}.


Part (c): Coefficient of Performance (COPref\text{COP}_{\text{ref}})

The coefficient of performance of a refrigerator measures the desired cooling effect relative to the required work input: COPref=Desired OutputRequired Input=∣QC∣∣Win∣\text{COP}_{\text{ref}} = \frac{\text{Desired Output}}{\text{Required Input}} = \frac{|Q_C|}{|W_{\text{in}}|}

Substitute the given absolute values: COPref=3.60×103 J9.00×102 J=4.00\text{COP}_{\text{ref}} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 4.00

The refrigeration cycle delivers 4.00 J4.00\text{ J} of cooling for every 1.00 J1.00\text{ J} of electrical work consumed.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student confuses the refrigerator coefficient of performance with that of a heat pump, defining it as heat delivered to the hot reservoir divided by work input.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    QC>0Q_C > 0 because heat is extracted into fluid ⟹Wfluid<0\Longrightarrow W_{\text{fluid}} < 0 because work is done on fluid ⟹QH<0\Longrightarrow Q_H < 0 because heat is expelled to room

  2. Step 2

    ΔUcycle=0⟹Qnet−Wfluid=0⟹QC+QH−(−∣Win∣)=0⟹QH=−QC−∣Win∣=−3.60×103 J−9.00×102 J=−4.50×103 J\Delta U_{\text{cycle}} = 0 \Longrightarrow Q_{\text{net}} - W_{\text{fluid}} = 0 \Longrightarrow Q_C + Q_H - (-|W_{\text{in}}|) = 0 \Longrightarrow Q_H = -Q_C - |W_{\text{in}}| = -3.60 \times 10^3\text{ J} - 9.00 \times 10^2\text{ J} = -4.50 \times 10^3\text{ J}

  3. Step 3

    COPref=∣QH∣∣Win∣=4.50×103 J9.00×102 J=5.00\text{COP}_{\text{ref}} = \frac{|Q_H|}{|W_{\text{in}}|} = \frac{4.50 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 5.00

    Correct

    COPref=∣QC∣∣Win∣=3.60×103 J9.00×102 J=4.00\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 4.00

    The objective of a refrigerator is cooling the low-temperature space, so the desired output is ∣QC∣|Q_C|, not the rejected heat ∣QH∣|Q_H|.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly established the sign conventions for heat entering, heat leaving, and work done on the fluid.

You correctly set ΔUcycle=0\Delta U_{\text{cycle}} = 0 and solved for the signed quantity QHQ_H using the First Law of Thermodynamics.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula confusion between refrigerator COP and heat pump COP

You substituted the heat delivered to the hot reservoir ∣QH∣|Q_H| into the numerator instead of the heat removed from the cold reservoir ∣QC∣|Q_C|.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the primary operational goal of a refrigerator (extracting heat ∣QC∣|Q_C| to keep a space cold) with that of a heat pump (delivering heat ∣QH∣|Q_H| to warm an interior space).

REASONING PATH
Your ACEpath teacher’s suggested approach
Define COP by Objective
  • COP=BenefitCost\text{COP} = \frac{\text{Benefit}}{\text{Cost}}. For a refrigerator, the desired benefit is cooling: ∣QC∣|Q_C|. For a heat pump, the desired benefit is heating: ∣QH∣|Q_H|.

  • Before writing the formula, identify the primary purpose: cooling means ∣QC∣|Q_C| goes in the numerator.

Relationship between COPs
  • For cycles operating between the same two reservoirs with identical work input, COPHP=COPref+1\text{COP}_{\text{HP}} = \text{COP}_{\text{ref}} + 1.

  • Check whether your computed value represents cooling (∣QC∣/∣W∣|Q_C|/|W|) or heating (∣QH∣/∣W∣|Q_H|/|W|).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the desired cooling effect for a refrigerator as ∣QC∣=3.60×103 J|Q_C| = 3.60 \times 10^3\text{ J}.

  2. Apply the refrigerator performance ratio: COPref=∣QC∣∣Win∣\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|}.

  3. Substitute the given magnitudes: COPref=3.60×103 J9.00×102 J=4.00\text{COP}_{\text{ref}} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 4.00.

Final answer

COPref=4.00\text{COP}_{\text{ref}} = 4.00

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the fundamental 'Benefit over Cost' definition for both refrigerators and heat pumps.

  • Practice identifying the numerator of COP based on whether the device is intended for refrigeration or space heating.

OverviewACEpath Teacher's Diagnosis

02 The student misinterprets the work term in the First Law equation ΔU = Q - W by treating work absorbed as positive work done by the fluid instead of negative.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    QC=+3.60×103 JQ_C = +3.60 \times 10^3\text{ J}, Wfluid=+9.00×102 JW_{\text{fluid}} = +9.00 \times 10^2\text{ J}, QH=−2.70×103 JQ_H = -2.70 \times 10^3\text{ J}

    Correct

    QC=+3.60×103 JQ_C = +3.60 \times 10^3\text{ J}, Wfluid=−9.00×102 JW_{\text{fluid}} = -9.00 \times 10^2\text{ J}, QH=−4.50×103 JQ_H = -4.50 \times 10^3\text{ J}

    In the standard formulation ΔU=Q−W\Delta U = Q - W, WfluidW_{\text{fluid}} represents the work done by the fluid. Because the motor does work on the fluid (work is absorbed), Wfluid=−∣Win∣=−9.00×102 JW_{\text{fluid}} = -|W_{\text{in}}| = -9.00 \times 10^2\text{ J}.

  2. Step 2

    ΔUcycle=0  ⟹  0=QC+QH−Wfluid  ⟹  QH=Wfluid−QC=9.00×102 J−3.60×103 J=−2.70×103 J\Delta U_{\text{cycle}} = 0 \implies 0 = Q_C + Q_H - W_{\text{fluid}} \implies Q_H = W_{\text{fluid}} - Q_C = 9.00 \times 10^2\text{ J} - 3.60 \times 10^3\text{ J} = -2.70 \times 10^3\text{ J}

    Correct

    ΔUcycle=0  ⟹  QH=Wfluid−QC=−9.00×102 J−3.60×103 J=−4.50×103 J\Delta U_{\text{cycle}} = 0 \implies Q_H = W_{\text{fluid}} - Q_C = -9.00 \times 10^2\text{ J} - 3.60 \times 10^3\text{ J} = -4.50 \times 10^3\text{ J}

    Your First Law setup and algebraic rearrangement were completely correct, but substituting the incorrect positive value for WfluidW_{\text{fluid}} led to QH=−2.70×103 JQ_H = -2.70 \times 10^3\text{ J} instead of −4.50×103 J-4.50 \times 10^3\text{ J}.

  3. Step 3

    COPref=∣QC∣∣Win∣=3.60×103 J9.00×102 J=4.00\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 4.00

WHAT YOU DID WELL
Compliments from Your Teacher

You recognized that the net internal energy change for a closed cycle is zero (ΔUcycle=0\Delta U_{\text{cycle}} = 0).

You correctly set up the First Law relation ΔU=Qnet−Wfluid\Delta U = Q_{\text{net}} - W_{\text{fluid}} and isolated QHQ_H.

You accurately defined and computed COPref\text{COP}_{\text{ref}} using the absolute energy values.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Work sign convention error in First Law

You assigned a positive sign to WfluidW_{\text{fluid}} even though work was performed on the fluid by an external motor.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing work done on the system (WinW_{\text{in}}) with work done by the system (Wby=WfluidW_{\text{by}} = W_{\text{fluid}}) when using the equation ΔU=Q−W\Delta U = Q - W.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check the Work Sign Convention
  • In ΔU=Q−W\Delta U = Q - W, WW is work done by the system. Work done on the system represents energy input, meaning Wby=−WonW_{\text{by}} = -W_{\text{on}}.

  • Always verify whether work enters or leaves the fluid: work absorbed means Wfluid<0W_{\text{fluid}} < 0.

Physical Reality Check for Heat Pumps and Refrigerators
  • The heat exhausted to the hot reservoir must equal the sum of the heat absorbed from the cold reservoir and the work input: ∣QH∣=∣QC∣+∣Win∣|Q_H| = |Q_C| + |W_{\text{in}}|.

  • Compare magnitudes before concluding: ∣QH∣|Q_H| must always be strictly greater than ∣QC∣|Q_C|.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the direction of work transfer: the motor does work on the working fluid, so work done by the fluid is negative: Wfluid=−9.00×102 JW_{\text{fluid}} = -9.00 \times 10^2\text{ J}.

  2. Substitute into the First Law: 0=QC+QH−Wfluid  ⟹  QH=Wfluid−QC=−9.00×102 J−3.60×103 J=−4.50×103 J0 = Q_C + Q_H - W_{\text{fluid}} \implies Q_H = W_{\text{fluid}} - Q_C = -9.00 \times 10^2\text{ J} - 3.60 \times 10^3\text{ J} = -4.50 \times 10^3\text{ J}.

Final answer

(a) QC=+3.60×103 JQ_C = +3.60 \times 10^3\text{ J}, Wfluid=−9.00×102 JW_{\text{fluid}} = -9.00 \times 10^2\text{ J}, QH=−4.50×103 JQ_H = -4.50 \times 10^3\text{ J}; (b) QH=−4.50×103 JQ_H = -4.50 \times 10^3\text{ J}; (c) COPref=4.00\text{COP}_{\text{ref}} = 4.00

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice identifying the system boundary and defining whether work is done 'by' or 'on' the gas before writing thermodynamic equations.

  • Use the energy conservation sanity check ∣QH∣=∣QC∣+∣Win∣|Q_H| = |Q_C| + |W_{\text{in}}| on refrigeration cycles to catch sign discrepancies immediately.

OverviewACEpath Teacher's Diagnosis

03 The student inverts the definition of the coefficient of performance as work input divided by extracted heat.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    QC>0  ⟹  Wfluid<0  ⟹  QH<0Q_C > 0 \implies W_{\text{fluid}} < 0 \implies Q_H < 0

  2. Step 2

    ΔUcycle=0  ⟹  QC+QH−Wfluid=0  ⟹  QH=−QC+Wfluid=−3.60×103 J−9.00×102 J=−4.50×103 J\Delta U_{\text{cycle}} = 0 \implies Q_C + Q_H - W_{\text{fluid}} = 0 \implies Q_H = -Q_C + W_{\text{fluid}} = -3.60 \times 10^3\text{ J} - 9.00 \times 10^2\text{ J} = -4.50 \times 10^3\text{ J}

  3. Step 3

    COPref=∣Win∣∣QC∣=9.00×102 J3.60×103 J=0.25\text{COP}_{\text{ref}} = \frac{|W_{\text{in}}|}{|Q_C|} = \frac{9.00 \times 10^2\text{ J}}{3.60 \times 10^3\text{ J}} = 0.25

    Correct

    COPref=∣QC∣∣Win∣=3.60×103 J9.00×102 J=4.00\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}} = 4.00

    You inverted the definition of the coefficient of performance. Performance metrics always compare desired output over required input: for a refrigerator, the desired output is the heat extracted from the cold space (∣QC∣|Q_C|), and the cost is the work input (∣Win∣|W_{\text{in}}|), giving COPref=∣QC∣∣Win∣\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the signs of heat and work entering and leaving the working fluid.

You correctly applied the cyclic property ΔUcycle=0\Delta U_{\text{cycle}} = 0 to balance the energy flow and determine QHQ_H.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Coefficient of Performance Definition

You set up the ratio as input over output rather than output over input.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the coefficient of performance (COP) formula with heat engine thermal efficiency (η=W/QH\eta = W/Q_H), leading to placing work in the numerator instead of remembering that all thermal performance metrics equal (desired benefit)/(required cost).

REASONING PATH
Your ACEpath teacher’s suggested approach
General Performance Metric Principle
  • Every thermodynamic performance metric follows Performance=What you get (Desired Benefit)What you pay for (Energy Input)\text{Performance} = \frac{\text{What you get (Desired Benefit)}}{\text{What you pay for (Energy Input)}}.

  • Ask yourself what the device is built to do: a refrigerator is built to remove heat ∣QC∣|Q_C| using work ∣Win∣|W_{\text{in}}|, so ∣QC∣|Q_C| belongs in the numerator.

Sanity Check for Refrigerator COP
  • Typical real-world refrigerators and heat pumps frequently have COP>1\text{COP} > 1 because heat is being moved rather than created.

  • If your calculated COP for a standard refrigerator is much less than 11 (like 0.250.25), immediately check if your numerator and denominator are flipped.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. State the definition of refrigerator performance: COPref=∣QC∣∣Win∣\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|}.

  2. Substitute the given magnitudes: COPref=3.60×103 J9.00×102 J\text{COP}_{\text{ref}} = \frac{3.60 \times 10^3\text{ J}}{9.00 \times 10^2\text{ J}}.

  3. Evaluate the quotient: COPref=4.00\text{COP}_{\text{ref}} = 4.00.

Final answer

COPref=4.00\text{COP}_{\text{ref}} = 4.00

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the universal ratio template: metric=desired effectwork or fuel input\text{metric} = \frac{\text{desired effect}}{\text{work or fuel input}}.

  • Contrast COPref=∣QC∣∣Win∣\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} with heat pump COPhp=∣QH∣∣Win∣\text{COP}_{\text{hp}} = \frac{|Q_H|}{|W_{\text{in}}|} and heat engine efficiency η=∣Wout∣∣QH∣\eta = \frac{|W_{\text{out}}|}{|Q_H|}.

Lock it in

Similar question

01

A household refrigerator removes 4.80×103 J4.80 \times 10^3\text{ J} of heat from its cold compartment while consuming 1.20×103 J1.20 \times 10^3\text{ J} of electrical work. Calculate its coefficient of performance COPref\text{COP}_{\text{ref}}.

Answer

COPref=∣QC∣∣Win∣=4.80×103 J1.20×103 J=4.00\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} = \frac{4.80 \times 10^3\text{ J}}{1.20 \times 10^3\text{ J}} = 4.00.

02

An air conditioner operates on a refrigeration cycle, rejecting 1.50×104 J1.50 \times 10^4\text{ J} of heat to the hot outdoor environment while requiring 3.00×103 J3.00 \times 10^3\text{ J} of work input. Determine the cooling provided ∣QC∣|Q_C| and the coefficient of performance COPref\text{COP}_{\text{ref}}.

Answer

By energy conservation, ∣QC∣=∣QH∣−∣Win∣=1.50×104 J−3.00×103 J=1.20×104 J|Q_C| = |Q_H| - |W_{\text{in}}| = 1.50 \times 10^4\text{ J} - 3.00 \times 10^3\text{ J} = 1.20 \times 10^4\text{ J}. Then, COPref=∣QC∣∣Win∣=1.20×104 J3.00×103 J=4.00\text{COP}_{\text{ref}} = \frac{|Q_C|}{|W_{\text{in}}|} = \frac{1.20 \times 10^4\text{ J}}{3.00 \times 10^3\text{ J}} = 4.00.

03

A reversible Carnot refrigerator maintains a freezer at TC=250 KT_C = 250\text{ K} while rejecting heat to a room at TH=300 KT_H = 300\text{ K}. (a) Calculate its theoretical COPref\text{COP}_{\text{ref}}. (b) If the same unit is operated as a heat pump between the same reservoirs, what is its COPHP\text{COP}_{\text{HP}}?

Answer

(a) COPref=TCTH−TC=250300−250=5.00\text{COP}_{\text{ref}} = \frac{T_C}{T_H - T_C} = \frac{250}{300 - 250} = 5.00. (b) COPHP=THTH−TC=30050=6.00\text{COP}_{\text{HP}} = \frac{T_H}{T_H - T_C} = \frac{300}{50} = 6.00 (or COPref+1=5.00+1=6.00\text{COP}_{\text{ref}} + 1 = 5.00 + 1 = 6.00).