A cylindrical storage tank of radius is filled with an industrial fluid of density open to the atmosphere where . Rather than calculating the resulting pressure at the bottom, determine the required liquid depth (in meters) such that the absolute pressure measured at the tank floor is exactly . Take .
Answer and steps
Final answer
Steps
Relate Absolute Pressure to Fluid Depth
Hydrostatic pressure in a fluid at rest depends on the depth below the surface, the density of the fluid, and the acceleration due to gravity. Because the tank is open to the atmosphere, the total (absolute) pressure at the bottom is the sum of the atmospheric pressure acting on the surface and the hydrostatic pressure exerted by the column of liquid:
Pitfall Note: The radius of the cylinder () is extra information. By Pascal's principle and the hydrostatic equation, pressure depends strictly on depth, not on the container's surface area or geometry.
Isolate the Required Depth
Subtract the atmospheric pressure from both sides to find the gauge pressure at the bottom, then solve for depth :
Calculate the Numerical Value
Substitute the given parameters:
First, compute the gauge pressure:
Next, calculate the denominator :
Finally, divide to determine :
Rounding to three significant figures gives:
Typical errors
01 The student confuses absolute pressure with gauge pressure and equates total pressure directly to ρgh without subtracting atmospheric pressure, resulting in an overestimated depth.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
Because the tank is open to the atmosphere, the absolute pressure at the bottom is the sum of atmospheric pressure and the fluid column pressure: . Equating the absolute pressure directly to treats the given total pressure as gauge pressure.
- Step 2Correct
Your numerical substitution and arithmetic are accurate according to your formula, but the numerator should be the net gauge pressure rather than the absolute pressure .
- Step 3Correct
Due to the missing atmospheric pressure subtraction in Step 1, your final calculated depth is significantly overestimated.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recognized that pressure in a static fluid depends on depth rather than the tank radius.
You manipulated your chosen algebraic formula cleanly to solve for .
You performed the numerical division accurately.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou conflated absolute pressure with gauge pressure. The expression represents only the hydrostatic pressure contributed by the liquid column itself (the gauge pressure). When an open container is subjected to atmospheric pressure at its free surface, that atmospheric pressure is transmitted uniformly throughout the fluid, making the total (absolute) pressure at depth equal to .
REASONING PATH
Your ACEpath teacher’s suggested approach- Open Surface vs. Closed Vacuum
For any container open to the ambient air, total pressure equals .
Always check whether the problem specifies an open container or gives , and include when working with absolute pressure.
- Absolute vs. Gauge Pressure
.
Before setting up , ask yourself whether the target pressure is gauge pressure or absolute pressure.
CORRECTED PATH
ACEpath Teacher's DemonstrationStart with the complete absolute hydrostatic pressure formula: .
Isolate the fluid depth : .
Substitute the given parameters: .
Evaluate the gauge pressure in the numerator: .
Divide by : .
02 The student adds atmospheric pressure instead of subtracting it when rearranging the hydrostatic equation for depth, leading to an incorrect pressure difference.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
To isolate the gauge pressure term , you must subtract from both sides of the equation, giving .
- Step 3Correct
Because you added atmospheric pressure in Step 2, the numerator computed the sum of the pressures rather than the gauge pressure difference, leading to an oversized depth.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified the hydrostatic pressure formula for an open tank.
You recognized that the tank radius is irrelevant to calculating pressure at depth.
You carried out the arithmetic and unit division accurately based on your rearranged formula.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou accidentally added atmospheric pressure instead of subtracting it when transposing it to the other side.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the total (absolute) pressure with the hydrostatic pressure contribution of the fluid column alone. The fluid column only accounts for the pressure above atmospheric pressure ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Gauge vs. Absolute Pressure
The liquid column exerts gauge pressure: .
Whenever you solve for depth from absolute pressure, always subtract to find the pressure contribution of the fluid.
- Physical Reality Check
The fluid contribution must be less than the total bottom pressure.
Notice that , whereas adding them gave , which would require a fluid column almost six times deeper.
CORRECTED PATH
ACEpath Teacher's Demonstration03 The student unnecessarily multiplies pressure by the tank cross-sectional area to find force but forgets to convert force back, dividing force by ρg to solve for depth.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You divided force by instead of pressure by . Because , the quantity yields the fluid volume in , not the liquid depth in .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified that the fluid column only needs to support the gauge pressure .
You accurately computed the gauge pressure as .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the total force into the hydrostatic depth equation where gauge pressure was required.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated pressure and force interchangeably when solving for depth. Dividing force by yields volume () rather than height ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Dimensional Check
Always verify that both sides of an isolated equation have matching physical units: , whereas .
Check that the numerator has units of pressure (pascals), not force (newtons), before dividing by specific weight .
- Geometry Independence in Hydrostatics
Hydrostatic pressure at depth in a static, uniform fluid depends solely on density, gravity, and depth (), completely independent of tank radius, cross-sectional area, or container shape.
Solve directly for depth using without calculating area or force.
CORRECTED PATH
ACEpath Teacher's DemonstrationRelate gauge pressure directly to fluid column depth using .
Isolate depth: .
Substitute the given values: .
Lock it in
What is the relationship between absolute pressure , gauge pressure , and atmospheric pressure ?
. Gauge pressure measures only the pressure exerted in excess of ambient atmospheric pressure.
Similar question
A swimming pool open to the air () contains fresh water of density . At what depth is the absolute pressure equal to ? Use .
Answer
. Calculate gauge pressure . Then .
An open vat filled with oil () is located in a high-altitude lab where atmospheric pressure is . A pressure gauge at the bottom measures an absolute pressure of . Determine the height of the oil column. Take .
Answer
. First find the gauge pressure exerted by the oil: . Then calculate depth: .
A vertical cylindrical tank open to the atmosphere () has radius . The maximum total force the circular base can withstand before failing is . If the tank is filled with a solvent of density (), what is the maximum permissible liquid depth ?
Answer
. Area of base . Maximum allowable absolute pressure is . The maximum gauge pressure is . Solving for depth: .