Resources
A hydraulic system filled with oil of density consists of a narrow piston of cross-sectional area and a wider load piston of cross-sectional area . When an input force of is applied downward on the narrow piston, the load piston rises until the system reaches a static threshold where the top surface of the load piston platform rests at an elevation of higher than the top surface of the input piston. Taking , determine the maximum total load force that can be supported on the output piston at this exact height threshold.
Answer and steps
Final answer
Steps
Identify the Pressure at the Reference Level
To find the load force , we apply the principle of hydrostatic equilibrium connecting the pressure at the two pistons.
In a continuous, static fluid, points at the same vertical height experience the same total pressure. Choose the horizontal plane passing through the base of the lower input piston (piston 1) as our reference level.
- Pressure at the input piston:
The pressure exerted just below piston 1 is the atmospheric pressure plus the pressure from the applied downward force : - Pressure at the same elevation below the load piston:
Piston 2 rests at an elevation above the reference level. Therefore, the pressure at the reference level in the wider column is the pressure directly beneath piston 2 plus the hydrostatic pressure of the oil column of height :
Equate the Pressures at the Reference Level
Since the fluid is in static equilibrium:
Subtracting from both sides yields:
Solving for the load force :
Common Pitfall: Forgetting the hydrostatic column assumes the pistons are at the exact same elevation (). When the output piston is elevated, part of the pressure generated by the input piston must support the weight of the elevated liquid column, reducing the net force available to support the external load.
Convert Units and Calculate
- Input area:
- Output area:
Calculate the input pressure:
Calculate the hydrostatic pressure of the oil column:
Substitute these values to find :
Rounding to two significant figures consistent with the given precision:
Typical errors
01 A student might add the hydrostatic head ρgh instead of subtracting it, incorrectly believing that the higher elevation increases pressure under the load piston.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Because the load piston is elevated at a height above the input piston, the fluid pressure decreases as elevation increases (). Consequently, the pressure directly under the elevated load piston is , not .
- Step 3Correct
You correctly applied the relationship , but your numerical result was affected by the incorrect value of from the previous step.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the cross-sectional areas from square centimeters to square meters.
You calculated the input gauge pressure and the hydrostatic pressure component accurately.
You used the correct relation between pressure, force, and area at the output piston.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou treated the pressure at the higher elevation as greater than the pressure at the lower elevation.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the direction of hydrostatic pressure variation with elevation. In a static fluid, pressure is highest at lower depths and decreases as vertical elevation increases (). Part of the pressure provided by the input piston must support the elevated column of liquid, leaving less available pressure to support the external load.
REASONING PATH
Your ACEpath teacher’s suggested approach- Pressure vs. Elevation Rule
In static fluids, pressure decreases with height: , or .
Always establish a reference horizontal plane at the lowest fluid surface where pressures are equal across interconnected columns.
- Physical Sanity Check for Hydraulics
Lifting liquid to an elevated platform requires pressure, which diminishes the net lifting capacity at that elevated piston.
Verify that raising the output piston above the input piston reduces compared to the ideal level-piston case ().
CORRECTED PATH
ACEpath Teacher's DemonstrationWrite the pressure equilibrium equation at the elevation of piston 1: .
Solve for the pressure under the load piston: .
Compute the supported load force: .
(or to three significant figures)
02 A student might neglect the hydrostatic pressure difference entirely and apply Pascal's principle directly as F2 = F1 × (A2 / A1).
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You assumed that the fluid pressures directly below both pistons are equal. Because the load piston rests at a vertical height above the input piston, the pressure at the input level must balance both the load piston pressure and the hydrostatic pressure of the elevated liquid column.
- Step 2Correct
You substituted the given values correctly into your uncorrected formula, but the calculation is missing the subtraction of the hydrostatic pressure term .
- Step 3Correct
Your arithmetic evaluation was carried out cleanly, but the resulting force is overestimated because the hydrostatic fluid column was not accounted for.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified the mechanical advantage concept relating the input force to the ratio of piston areas.
You performed the algebraic manipulation and arithmetic steps accurately without calculation errors.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou applied standard Pascal's principle () without checking whether the fluid surfaces are at the same horizontal reference level. When fluid columns have an elevation difference , static equilibrium requires equating pressures at the same horizontal datum: .
REASONING PATH
Your ACEpath teacher’s suggested approach- Establish a Common Horizontal Datum
In a continuous static liquid, pressures are equal only at the same vertical level: .
Always draw a horizontal reference line at the lower piston surface and sum the hydrostatic column under the higher piston.
- Account for Fluid Column Weight
An elevated piston requires part of the input pressure simply to support the weight of the fluid column of height .
Subtract from the available input pressure before multiplying by the output piston area .
CORRECTED PATH
ACEpath Teacher's DemonstrationChoose the horizontal level of the lower input piston as the reference datum: .
Express the pressures in terms of forces and areas: .
Convert areas to standard SI units: and .
Compute the input pressure: .
Compute the hydrostatic pressure of the oil column: .
Calculate the net pressure available for the load: .
Multiply by the output area: .
03 A student might incorrectly convert the areas by dividing by 100 rather than 10000 when converting cm² to m².
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You divided by as if converting linear centimeters to meters. Because area scales with the square of length, , so you must divide by .
- Step 2Correct
Your formula for pressure is correct, but substituting your incorrectly converted area produced an input pressure that is times too small.
- Step 3
- Step 4Correct
You applied the correct hydrostatic equilibrium condition (), but the underestimated caused this difference to turn negative.
- Step 5Correct
Your method of multiplying gauge pressure by area was correct, but the carried-over errors in and affected your final result.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified that the elevated oil column creates a hydrostatic pressure difference between the two pistons.
You accurately calculated the hydrostatic pressure term using the correct density, gravity, and height values.
You correctly subtracted the column pressure from the input pressure to find the net gauge pressure at the output piston.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou divided by instead of when converting to .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisTreating two-dimensional units (area) as one-dimensional (linear) units during metric conversion. When converting square centimeters to square meters, the linear scale factor of must also be squared: .
REASONING PATH
Your ACEpath teacher’s suggested approach- Area Conversion Check
Always write out before converting any area.
- Physical Reality Check
An applied downward force on a hydraulic lift should support a positive upward load force.
If your calculated output pressure or force turns out negative, immediately re-check your area conversions and pressure magnitudes.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert areas using : and .
Recalculate input pressure: .
Subtract the hydrostatic column pressure: .
Compute the load force: .
(or to two significant figures)
Lock it in
In a continuous static fluid, if point B is a vertical distance higher than point A, how are their pressures and related?
(or ). Pressure always decreases as elevation increases because there is less fluid weight above.
Similar question
A hydraulic jack filled with oil () has an input piston of area and an output piston of area . A force of is applied downward on the input piston. If the output piston rests at an elevation above the input piston, find the pressure directly under the output piston. Take .
Answer
. The hydrostatic head is . Subtracting because the output piston is higher: .
A hydraulic lift filled with water () supports a car of mass on a platform of area . The narrow piston has area . What downward force must be applied on the narrow piston when the car is held in static equilibrium at a height above the narrow piston? Take .
Answer
Load force is . Pressure under load piston is . Because the narrow piston is at the lower level, . Thus .
In a U-tube hydraulic apparatus, piston 1 has area and piston 2 has area . The fluid has density . If piston 1 is positioned at an elevation higher than piston 2, determine the load force supported on piston 2 when a downward force of is exerted on piston 1. Take .
Answer
Pressure under piston 1 is . Here, piston 2 is lower by , so fluid pressure increases toward piston 2: . The load force is .