Resources

A student attempts to double the Carnot efficiency of an ideal heat engine operating between reservoirs at TH=400 KT_H = 400\text{ K} and TC=300 KT_C = 300\text{ K} by simply doubling the hot reservoir temperature to TH′=800 KT_H' = 800\text{ K} while keeping TCT_C fixed. Calculate the initial Carnot efficiency η1\eta_1, the new efficiency η2\eta_2, and the actual percentage increase in thermal efficiency relative to η1\eta_1.

Answer and steps

Final answer

η1=25.0%\eta_1 = 25.0\%, η2=62.5%\eta_2 = 62.5\%; the efficiency increases by 150%150\% (a factor of 2.502.50, not 2.002.00).

Steps

01

Definition of Carnot Efficiency

The maximum theoretical thermal efficiency of an ideal heat engine operating between an absolute hot reservoir temperature THT_H and cold reservoir temperature TCT_C is given by the Carnot efficiency formula:

η=1−TCTH\eta = 1 - \frac{T_C}{T_H}

where temperatures must always be expressed in Kelvin (K\text{K}).


02

Calculate the Initial Efficiency (η1\eta_1)

Substitute the initial temperatures TH=400 KT_H = 400\text{ K} and TC=300 KT_C = 300\text{ K}:

η1=1−300 K400 K=1−0.75=0.25\eta_1 = 1 - \frac{300\text{ K}}{400\text{ K}} = 1 - 0.75 = 0.25

Expressed as a percentage:

η1=25.0%\eta_1 = 25.0\%


03

Calculate the New Efficiency (η2\eta_2)

When the hot reservoir temperature is doubled to TH′=800 KT_H' = 800\text{ K} while maintaining TC=300 KT_C = 300\text{ K}:

η2=1−300 K800 K=1−0.375=0.625\eta_2 = 1 - \frac{300\text{ K}}{800\text{ K}} = 1 - 0.375 = 0.625

Expressed as a percentage:

η2=62.5%\eta_2 = 62.5\%


04

Determine the Relative Percentage Increase

Compare the new efficiency to the original efficiency:

  • Factor increase: η2η1=0.6250.250=2.50\frac{\eta_2}{\eta_1} = \frac{0.625}{0.250} = 2.50
  • Percentage increase: Percentage Increase=η2−η1η1×100%=0.625−0.2500.250×100%=0.3750.250×100%=150%\text{Percentage Increase} = \frac{\eta_2 - \eta_1}{\eta_1} \times 100\% = \frac{0.625 - 0.250}{0.250} \times 100\% = \frac{0.375}{0.250} \times 100\% = 150\%

Common Pitfall to Avoid

Carnot efficiency depends inversely on THT_H, not linearly. Therefore, doubling the absolute temperature of the hot reservoir does not simply double the efficiency from 25%25\% to 50%50\%; instead, it reduces the discarded fraction TCTH\frac{T_C}{T_H} by half, which increases the efficiency by a factor of 2.502.50 (a 150%150\% increase) to 62.5%62.5\%.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student confuses percentage point increase with relative percentage increase, reporting the difference between efficiencies rather than dividing by the initial efficiency.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    η1=1−300400=0.25=25%\eta_1 = 1 - \frac{300}{400} = 0.25 = 25\%

  2. Step 2

    η2=1−300800=0.625=62.5%\eta_2 = 1 - \frac{300}{800} = 0.625 = 62.5\%

  3. Step 3

    Percentage increase\text{Percentage increase} = 62.5% - 25% = 37.5%

    Correct

    Percentage increase\text{Percentage increase} = η2−η1η1\frac{\eta_2 - \eta_1}{\eta_1} ×\times 100% = 62.5%−25%25%\frac{62.5\% - 25\%}{25\%} ×\times 100% = 150%

    You subtracted the two efficiencies, which gives the absolute increase in percentage points (37.5 percentage points37.5\text{ percentage points}). To find the relative percentage increase, you must divide that difference by the original value η1\eta_1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied the Carnot efficiency formula η=1−TCTH\eta = 1 - \frac{T_C}{T_H}.

You properly evaluated both η1=25%\eta_1 = 25\% and η2=62.5%\eta_2 = 62.5\% using absolute temperatures in Kelvin.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Percentage points vs. relative percentage increase

You subtracted the initial percentage from the final percentage without dividing by the baseline efficiency.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating an absolute difference in percentage points (Δη\Delta \eta) with a relative percentage change (Δηη1×100%\frac{\Delta \eta}{\eta_1} \times 100\%). When a quantity is already expressed as a percentage, a change in its value must still be divided by the original reference value to find the relative percentage increase.

REASONING PATH
Your ACEpath teacher’s suggested approach
Relative Percentage Change vs. Percentage Points
  • Relative % Increase=final−initialinitial×100%\text{Relative \% Increase} = \frac{\text{final} - \text{initial}}{\text{initial}} \times 100\%, whereas Δη=final−initial\Delta \eta = \text{final} - \text{initial} represents percentage points.

  • Always divide the difference by the initial value before multiplying by 100%100\% whenever a problem asks for relative percentage change.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Find the absolute change in efficiency: Δη=η2−η1=62.5%−25.0%=37.5%\Delta \eta = \eta_2 - \eta_1 = 62.5\% - 25.0\% = 37.5\%.

  2. Divide the absolute change by the initial efficiency η1\eta_1: Δηη1=0.3750.250=1.50\frac{\Delta \eta}{\eta_1} = \frac{0.375}{0.250} = 1.50.

  3. Multiply by 100%100\% to express as a relative percentage increase: 1.50×100%=150%1.50 \times 100\% = 150\%.

Final answer

η1=25.0%\eta_1 = 25.0\%, η2=62.5%\eta_2 = 62.5\%, and the efficiency increases by 150%150\%.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the distinction between percentage points and relative percentage change.

  • Practice calculating relative changes for quantities that are already stated in percentages, such as efficiency, concentration, or interest rates.

OverviewACEpath Teacher's Diagnosis

02 The student inverts the Carnot efficiency temperature ratio as T_H / T_C or assumes efficiency is directly proportional to T_H / T_C, leading to an incorrect efficiency calculation.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    η1=1−THTC=1−400300=−0.33\eta_1 = 1 - \frac{T_H}{T_C} = 1 - \frac{400}{300} = -0.33

    Correct

    η1=1−TCTH=1−300 K400 K=0.25 (or 25.0%)\eta_1 = 1 - \frac{T_C}{T_H} = 1 - \frac{300\text{ K}}{400\text{ K}} = 0.25\text{ (or }25.0\%\text{)}

    You inverted the temperature ratio. The Carnot efficiency is defined as η=1−TCTH\eta = 1 - \frac{T_C}{T_H}, which represents 1−QCQH1 - \frac{Q_C}{Q_H}. Because TH>TCT_H > T_C, your formula produced an impossible negative efficiency.

  2. Step 2

    η2=1−TH′TC=1−800300=−1.67\eta_2 = 1 - \frac{T_H'}{T_C} = 1 - \frac{800}{300} = -1.67

    Correct

    η2=1−TCTH′=1−300 K800 K=0.625 (or 62.5%)\eta_2 = 1 - \frac{T_C}{T_H'} = 1 - \frac{300\text{ K}}{800\text{ K}} = 0.625\text{ (or }62.5\%\text{)}

    You repeated the inverted temperature ratio TH′TC\frac{T_H'}{T_C} instead of using TCTH′\frac{T_C}{T_H'}.

  3. Step 3

    Percentage increase=(−1.67−(−0.33)−0.33)×100%=406%\text{Percentage increase} = \left(\frac{-1.67 - (-0.33)}{-0.33}\right) \times 100\% = 406\%

    Correct

    Percentage increase=η2−η1η1×100%=0.625−0.2500.250×100%=150%\text{Percentage increase} = \frac{\eta_2 - \eta_1}{\eta_1} \times 100\% = \frac{0.625 - 0.250}{0.250} \times 100\% = 150\%

    You correctly applied the relative percentage increase formula η2−η1η1×100%\frac{\eta_2 - \eta_1}{\eta_1} \times 100\%, but the numerical result was thrown off by the incorrect efficiency values from earlier steps.

WHAT YOU DID WELL
Compliments from Your Teacher

You recognized that absolute temperatures in Kelvin are required for Carnot calculations.

You used the correct relative percentage increase formula.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Carnot temperature ratio

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You swapped the numerator and denominator in the heat/temperature ratio, using 1−THTC1 - \frac{T_H}{T_C} rather than 1−TCTH1 - \frac{T_C}{T_H}. Because the cold reservoir receives the exhausted heat, the wasted heat fraction is QCQH=TCTH\frac{Q_C}{Q_H} = \frac{T_C}{T_H}, which must be less than 11.

REASONING PATH
Your ACEpath teacher’s suggested approach
Sanity check efficiency bounds
  • For any heat engine operating forward, thermal efficiency must satisfy 0≤η<10 \le \eta < 1.

  • Whenever you calculate η\eta, immediately check if the value is negative or exceeds 11; if so, check whether you inverted the temperature ratio.

Energy accounting ratio
  • Efficiency is η=WQH=QH−QCQH=1−QCQH=1−TCTH\eta = \frac{W}{Q_H} = \frac{Q_H - Q_C}{Q_H} = 1 - \frac{Q_C}{Q_H} = 1 - \frac{T_C}{T_H}.

  • Remember that the denominator is always the heat input from the hot reservoir (THT_H), while the numerator is the discarded heat to the cold reservoir (TCT_C).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compute initial efficiency: η1=1−TCTH=1−300 K400 K=0.250=25.0%\eta_1 = 1 - \frac{T_C}{T_H} = 1 - \frac{300\text{ K}}{400\text{ K}} = 0.250 = 25.0\%

  2. Compute new efficiency: η2=1−TCTH′=1−300 K800 K=0.625=62.5%\eta_2 = 1 - \frac{T_C}{T_H'} = 1 - \frac{300\text{ K}}{800\text{ K}} = 0.625 = 62.5\%

  3. Compute the relative percentage increase: η2−η1η1×100%=0.625−0.2500.250×100%=0.3750.250×100%=150%\frac{\eta_2 - \eta_1}{\eta_1} \times 100\% = \frac{0.625 - 0.250}{0.250} \times 100\% = \frac{0.375}{0.250} \times 100\% = 150\%

Final answer

η1=25.0%\eta_1 = 25.0\%, η2=62.5%\eta_2 = 62.5\%, and the percentage increase is 150%150\%.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the thermodynamic derivation of η=1−QCQH=1−TCTH\eta = 1 - \frac{Q_C}{Q_H} = 1 - \frac{T_C}{T_H}.

  • Practice checking that the fraction TCTH\frac{T_C}{T_H} is always between 00 and 11 for TH>TCT_H > T_C.

  • Complete the follow-up exercises to solidify comparing efficiency changes when altering reservoir temperatures.

OverviewACEpath Teacher's Diagnosis

03 The student incorrectly divides the change by the final efficiency η₂ instead of the initial efficiency η₁ when calculating the relative percentage increase.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    η1=1−300400=0.25\eta_1 = 1 - \frac{300}{400} = 0.25

  2. Step 2

    η2=1−300800=0.625\eta_2 = 1 - \frac{300}{800} = 0.625

  3. Step 3

    Percentage increase=(0.625−0.250.625)×100%=60%\text{Percentage increase} = \left(\frac{0.625 - 0.25}{0.625}\right) \times 100\% = 60\%

    Correct

    Percentage increase=η2−η1η1×100%=(0.625−0.250.25)×100%=150%\text{Percentage increase} = \frac{\eta_2 - \eta_1}{\eta_1} \times 100\% = \left(\frac{0.625 - 0.25}{0.25}\right) \times 100\% = 150\%

    You placed the new value η2=0.625\eta_2 = 0.625 in the denominator instead of the reference base value η1=0.25\eta_1 = 0.25. Relative percentage increase is always defined as final−initialinitial×100%\frac{\text{final} - \text{initial}}{\text{initial}} \times 100\%.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the Carnot efficiency formula η=1−TCTH\eta = 1 - \frac{T_C}{T_H}.

You accurately evaluated both numerical efficiencies η1=0.25\eta_1 = 0.25 and η2=0.625\eta_2 = 0.625.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Incorrect Base in Percentage Increase

You accidentally divided the change by the final efficiency η2\eta_2 instead of the baseline initial efficiency η1\eta_1.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the reference base (initial state) with the final state when setting up the relative percentage change formula.

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify the Reference Value
  • Whenever a problem asks for an increase or change 'relative to XX', the denominator must be XX (the initial baseline).

  • Always write out final−initialinitial×100%\frac{\text{final} - \text{initial}}{\text{initial}} \times 100\% before substituting numbers.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. State the relative change formula with respect to η1\eta_1: Percentage Increase=η2−η1η1×100%\text{Percentage Increase} = \frac{\eta_2 - \eta_1}{\eta_1} \times 100\%.

  2. Substitute η1=0.25\eta_1 = 0.25 and η2=0.625\eta_2 = 0.625: 0.625−0.250.25×100%=0.3750.25×100%\frac{0.625 - 0.25}{0.25} \times 100\% = \frac{0.375}{0.25} \times 100\%.

  3. Simplify the fraction: 1.50×100%=150%1.50 \times 100\% = 150\%.

Final answer

η1=25.0%\eta_1 = 25.0\%, η2=62.5%\eta_2 = 62.5\%; the efficiency increases by 150%150\%.

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check your denominator whenever calculating percentage changes to ensure it represents the original baseline value.

  • Practice identifying whether a percentage comparison asks for relative increase (divided by initial) or fraction of the new total (divided by final).

Lock it in

Similar question

01

A solar cell increases its power conversion efficiency from 12.0%12.0\% to 18.0%18.0\%. Calculate the absolute gain in percentage points and the relative percentage increase in efficiency.

Answer

The absolute gain is 18.0%−12.0%=6.0 percentage points18.0\% - 12.0\% = 6.0\text{ percentage points}. The relative percentage increase is 18.0%−12.0%12.0%×100%=6.012.0×100%=50.0%\frac{18.0\% - 12.0\%}{12.0\%} \times 100\% = \frac{6.0}{12.0} \times 100\% = 50.0\%.

02

A heat engine operates between TH=600 KT_H = 600\text{ K} and TC=300 KT_C = 300\text{ K}. If the cold reservoir temperature is lowered to TC′=150 KT_C' = 150\text{ K} while THT_H stays constant, what is the relative percentage increase in its Carnot efficiency?

Answer

Initial efficiency is η1=1−300600=50.0%\eta_1 = 1 - \frac{300}{600} = 50.0\%. New efficiency is η2=1−150600=75.0%\eta_2 = 1 - \frac{150}{600} = 75.0\%. The relative percentage increase is 75.0%−50.0%50.0%×100%=25.0%50.0%×100%=50.0%\frac{75.0\% - 50.0\%}{50.0\%} \times 100\% = \frac{25.0\%}{50.0\%} \times 100\% = 50.0\%.

03

An engineer claims that improving a real turbine's thermal efficiency from 30%30\% to 45%45\% represents a 15%15\% performance gain. By what factor did the efficiency actually multiply, and what is the true percentage increase in work output per unit of heat input?

Answer

The factor increase is 45%30%=1.50\frac{45\%}{30\%} = 1.50. The true relative percentage increase is 45%−30%30%×100%=50%\frac{45\% - 30\%}{30\%} \times 100\% = 50\%. The engineer cited the 1515 percentage-point difference rather than the 50%50\% relative increase.

Loading workspace…