Resources
A micro-fabricated sensor trace on an integrated circuit has a length of and carries a direct current of . The trace lies perpendicular to a magnetic field generated by an electromagnet, which is measured in laboratory units as (, where ). Convert all quantities to standard SI units and calculate the resulting magnetic force exerted on the trace in micronewtons ().
Answer and steps
Final answer
(or )
Steps
Identify the Formula and Given Values
The magnetic force exerted on a straight wire carrying current in a uniform magnetic field is given by:
where:
- is the electric current through the conductor.
- is the length of the conductor in the field.
- is the magnetic field strength.
- is the angle between the direction of the current and the magnetic field vector.
Because the sensor trace lies perpendicular to the magnetic field, , which gives . The formula simplifies to:
Convert All Quantities to Standard SI Units
To calculate the force in newtons (), all input parameters must be expressed in SI base units (, , and ):
- Current ():
- Length ():
- Magnetic Field (): Using and :
Calculate the Magnetic Force
Substitute the converted values into the simplified force formula:
Convert to Micronewtons ()
Since :
Rounding to three significant figures gives:
Typical errors
01 The student misinterprets the prefix kilo- as 10⁻³ instead of 10³, leading to an underestimated magnetic field and force.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You substituted instead of for the prefix kilo- (). Because , multiplying by gives , not .
- Step 3Correct
Your substitution and calculation using the magnetic force formula were algebraically correct, but the result inherited the error from the incorrect magnetic field value.
- Step 4Correct
You correctly multiplied by to convert from newtons to micronewtons, but the initial force value was off by a factor of due to the earlier conversion slip.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified and applied the perpendicular magnetic force formula .
You properly converted length from millimeters to meters and current from milliamperes to amperes.
You correctly applied the conversion factor .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of when expanding the prefix kilo- in kilogauss.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the positive power metric prefix kilo- () with the negative power metric prefix milli- () during multi-step unit conversion.
REASONING PATH
Your ACEpath teacher’s suggested approach- Check prefix sign and magnitude
Kilo- () denotes (thousands), whereas milli- () denotes (thousandths).
Whenever you see a lowercase 'k' in front of a unit, replace it with before continuing conversion.
- Chain unit conversions explicitly
Write out conversion fractions so units cancel cleanly: .
Set up dimensional analysis factors to eliminate ambiguity in the power of 10.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert kilogauss to teslas: .
Compute the magnetic force in newtons: .
Convert newtons to micronewtons: .
02 The student forgets to convert length from millimeters to meters, using 8.50 instead of 8.50 × 10⁻³ m in the force formula.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
, , and
You correctly converted the current to amperes and the magnetic field from kilogauss to teslas, but you left the length in millimeters instead of converting it to the base SI unit of meters ().
- Step 2Correct
You correctly selected and applied the perpendicular force formula , but substituting the uncoverted value instead of yielded an intermediate force in newtons that was times too large.
- Step 3Correct
You correctly used the conversion factor , but because your force in newtons carried the earlier length unit error, your final answer became instead of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recalled and applied the magnetic force formula for a perpendicular wire, .
You accurately converted the current from milliamperes to amperes ().
You successfully converted the magnetic field from kilogauss to teslas ().
You correctly recognized that when attempting the prefix conversion to micronewtons.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou substituted the numerical value of length directly in millimeters () rather than converting it to the SI base unit of meters () prior to calculating force in newtons.
REASONING PATH
Your ACEpath teacher’s suggested approach- SI Base Unit Consistency
In electromagnetic force formulas (), length must be in meters () so that .
Always convert every metric prefix (such as to , where ) before evaluating the product.
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert length to SI units: .
Substitute the SI values into the force equation: .
Convert newtons to micronewtons: .
(or )
03 The student multiplies by 10⁻⁶ instead of dividing when converting force from newtons to micronewtons.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You multiplied by instead of dividing by . Because , converting from a larger base unit () to a smaller metric-prefixed unit () requires multiplying by or dividing by .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted milliamperes, millimeters, and kilogauss into standard SI units.
You selected and calculated the magnetic force using accurately in newtons.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeMultiplying by the prefix factor when moving from the base unit to the micro-unit.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConflating unit substitution with unit factor cancellation. While can be directly replaced by , replacing requires using . Converting to a smaller unit must always result in a larger numerical magnitude.
REASONING PATH
Your ACEpath teacher’s suggested approach- Direction of Metric Scaling
When converting from a base unit to a sub-unit with prefix , the numerical value must increase by a factor of .
Check your units with dimensional analysis: multiply by the fraction so that cancels in the denominator.
CORRECTED PATH
ACEpath Teacher's DemonstrationApply dimensional analysis with the conversion factor :
Simplify the powers of ten:
Round to three significant figures to match the given data:
Lock it in
What numerical factor does the metric prefix kilo- () represent?
(or ). Remember: positive power for larger quantities (kilo-), negative power for smaller quantities (milli- ).
Similar question
A straight wire of length carries a current of perpendicular to a uniform magnetic field of . Calculate the magnetic force on the wire in newtons.
Answer
. Steps: Convert units: , . Apply .
A micro-actuator wire has length and carries a current of . It is oriented at an angle of relative to a uniform field of . Find the magnetic force exerted on the wire in micronewtons ().
Answer
. Steps: Convert units: , , . Calculate force: .
A straight conductor of length carries a direct current in a perpendicular magnetic field of . The resulting magnetic force is measured to be . Determine the current flowing through the conductor in milliamperes ().
Answer
. Steps: Convert knowns to SI: , , . Solve for .