Resources
An electric generator consists of a flat rectangular coil with , each having dimensions of . The coil rotates at a constant angular frequency of () inside a uniform horizontal magnetic field of magnitude . (a) Calculate the maximum electromotive force (peak emf, ) induced in the coil. (b) If the output of this generator is connected across the primary winding of an ideal step-down transformer having and , determine the root-mean-square (rms) voltage delivered across the secondary load.
Answer and steps
Final answer
(a) ; (b)
Steps
Part (a): Calculating the Peak Electromotive Force ()
- Calculate the cross-sectional area of the coil (): Convert the dimensions of the rectangular coil into standard SI units (meters):
-
Apply Faraday's law of electromagnetic induction to an AC generator: As the coil rotates with angular velocity in a uniform magnetic field , the magnetic flux through a single loop at time is:
According to Faraday's law, the induced electromotive force in an -turn coil is:
-
Determine the peak emf (): The maximum (peak) value occurs when :
Substitute the given numerical values:
Part (b): Finding the RMS Voltage Across the Secondary Load ()
- Determine the peak voltage across the primary winding (): Because the generator output is connected directly to the primary coil of the transformer:
-
Relate the primary and secondary voltages using the transformer turns ratio: For an ideal transformer, the ratio of the voltages equals the ratio of the turns:
Therefore, the peak secondary voltage is:
-
Calculate the root-mean-square (rms) secondary voltage (): For a sinusoidal alternating voltage, the rms voltage is related to the peak voltage by:
Applying this to the secondary voltage:
Common Pitfall: Do not confuse the peak voltage () with the root-mean-square voltage (). Household and standard AC ratings are quoted in rms, which is a factor of times the peak value. Applying the turns ratio to the peak voltage and then converting to rms, or converting to rms first and then applying the turns ratio, yields the same result:
Typical errors
01 The student forgets to convert the dimensions of the coil from centimeters to meters, resulting in an area that is too large by a factor of 10⁴.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You correctly applied Faraday's formula for the peak emf of a rotating coil, . However, you substituted the area in rather than the SI base unit . Since , , which yields .
- Step 2Correct
You used the correct transformer turns ratio . Your calculation is mathematically consistent with your peak emf from step 1, but the numerical result is inflated because of the initial unit conversion error.
- Step 3Correct
You correctly related the root-mean-square voltage to the peak voltage using . This step is methodologically sound and only inherits the scale factor error from step 1.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recalled and applied the generator peak electromotive force formula .
You used the ideal transformer turns ratio accurately to step down the primary voltage.
You correctly converted the peak sinusoidal voltage to root-mean-square voltage by dividing by .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the area as directly without converting to .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the dimensions as simple numbers in standard formulas without first expressing length in meters, overlooking that converting square centimeters to square meters requires multiplying by ().
REASONING PATH
Your ACEpath teacher’s suggested approach- SI Unit Check Before Formula Substitution
Every magnetic and electromagnetic formula involving teslas () requires lengths in meters () and areas in square meters ().
Convert linear dimensions to meters before multiplying: and , so .
CORRECTED PATH
ACEpath Teacher's DemonstrationConvert the dimensions to meters: and , giving .
Calculate the peak emf: .
Find the secondary peak voltage using the turns ratio: .
Convert to secondary rms voltage: .
(a) ; (b)
02 The student confuses the generator's rotational frequency f with angular frequency ω, multiplying by 2π again to get an angular frequency of 240π² rad/s.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
The problem already gave the angular frequency as (corresponding to linear frequency , where ). You treated as linear frequency and multiplied by again.
- Step 3Correct
Your peak emf formula and arithmetic were correct, but the result was inflated because of the incorrect value of from Step 2.
- Step 4Correct
You correctly applied the ideal transformer voltage equation , carrying forward your previous peak voltage value.
- Step 5Correct
You used the correct relation between peak voltage and rms voltage (), with the error tracing entirely back to Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the rectangular dimensions to find the coil area in square meters.
You selected the correct formula for the peak induced electromotive force.
You accurately applied the ideal transformer turns ratio to relate primary and secondary voltages.
You correctly converted peak alternating voltage to root-mean-square voltage by dividing by .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeMultiplying by to get .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou confused angular frequency (measured in ) with ordinary rotational frequency (measured in or ). When a rate is already stated with symbol or units of , the factor of is already included.
REASONING PATH
Your ACEpath teacher’s suggested approach- Unit Inspection
Linear frequency has units of or , whereas angular frequency has units of .
Check the given units before applying ; if the value already has , use it directly as .
- Peak vs. RMS Timing in Transformers
Because an ideal transformer scales voltages linearly (), you can convert peak to rms either before or after applying the turns ratio: .
Always verify whether your transformer input is peak or rms, and convert at the most convenient stage.
CORRECTED PATH
ACEpath Teacher's DemonstrationUse the given angular frequency directly: .
Calculate the peak emf: .
Find the secondary peak voltage using the turns ratio: .
Calculate the secondary rms voltage: .
(a) ; (b)
03 The student treats the peak voltage directly as the rms voltage, failing to divide the secondary peak voltage by √2 to find the rms value.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
The value is the peak secondary voltage (), not the root-mean-square voltage. For a sinusoidal AC signal, you need to divide the peak value by .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the cross-sectional area in SI units.
You used the correct peak emf formula for a rotating AC generator.
You set up and evaluated the transformer turns ratio accurately.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the peak output voltage from the transformer as the root-mean-square (rms) voltage without applying the sinusoidal conversion factor .
REASONING PATH
Your ACEpath teacher’s suggested approach- Peak vs. RMS in Sinusoidal AC
For sinusoidal alternating voltage, the peak amplitude relates to the effective rms voltage by .
Always check whether an AC question asks for peak voltage () or rms voltage (), and divide sinusoidal peak values by when finding rms.
CORRECTED PATH
ACEpath Teacher's DemonstrationRecognize that the calculated secondary voltage is the peak amplitude: .
Apply the sinusoidal conversion formula: .
(a) ; (b)
Lock it in
How do you convert an area measured in square centimeters () into standard SI units of square meters ()?
Multiply by (or divide by ). Remember: , so .
Similar question
A square coil of side length has and rotates at in a uniform magnetic field of . Calculate the peak electromotive force induced in the coil.
Answer
. Key steps: ; then .
A circular generator coil has radius and . It rotates at in a field of . The generator's output is connected to an ideal transformer with and . Find the peak voltage across the secondary coil.
Answer
. Key steps: ; ; ; .
An AC generator with a rectangular coil of and produces a peak emf of when rotating at . The generator is linked to a transformer with turns ratio . Determine (a) the magnetic field strength and (b) the secondary root-mean-square voltage .
Answer
(a) ; (b) . Key steps: ; ; ; .