Resources
A flat composite furnace wall consists of an inner refractory brick layer of thermal conductivity and thickness , followed by an outer insulating layer of thermal conductivity and thickness . The inner face of the brick is maintained at () and the outer face of the insulation is maintained at (). Assuming steady-state, one-dimensional conduction across a surface area of , calculate: (a) the total rate of heat transfer through the wall by conduction , and (b) the interface temperature between the refractory brick and the insulation.
Answer and steps
Final answer
(a) (or ); (b) ().
Steps
Part (a): Rate of Heat Transfer Through the Wall
Under steady-state, one-dimensional conditions, heat conduction through composite layers in series is governed by Fourier's law of thermal conduction, analogous to electrical resistance:
-
Calculate the thermal resistance of each layer: The conduction thermal resistance of a plane layer is given by :
- Refractory brick (Layer 1):
- Insulating layer (Layer 2):
- Calculate the total thermal resistance: Since the two layers are in series:
- Determine the overall temperature difference:
- Compute the total rate of heat transfer :
Part (b): Interface Temperature Between the Layers
The temperature drop across the inner layer depends on the resistance apportioned to the refractory brick:
- The unit area thermal resistance of the brick layer is:
Applying the temperature drop fraction based on the brick's thermal resistance relative to the total circuit resistance :
Subtracting this temperature drop from the inside surface temperature:
Expressed in Kelvin:
Typical errors
01 The student inverts the formula for thermal resistance as R = k / (L · A) instead of L / (k · A), leading to an incorrect total resistance and flawed heat transfer rate.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
,
Correct,
You inverted the ratio of thickness to conductivity in the thermal resistance formula. Conduction thermal resistance is proportional to thickness and inversely proportional to thermal conductivity and area: .
- Step 2Correct
You correctly added the two series resistances together, but the sum carries over the incorrect values from Step 1.
- Step 3Correct
You correctly determined the temperature difference and set up , but your result is affected by the incorrect value of .
- Step 4Correct
You correctly related the interface temperature drop across the first layer to heat flow and resistance, but substituting your earlier values led to an incorrect interface temperature.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly recognized that composite conduction layers in steady state act as thermal resistances in series.
You accurately found the overall temperature difference across the furnace wall.
You set up the interface temperature relation across the first layer with completely sound logic.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou accidentally placed thermal conductivity in the numerator and thickness in the denominator when calculating conduction resistance.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing thermal resistance with thermal conductance per unit area or misremembering how material thickness and conductivity physically affect resistance to heat flow.
REASONING PATH
Your ACEpath teacher’s suggested approach- Physical Trend Check
A thicker layer () increases resistance to heat flow, while a better conductor () and a larger cross-section () reduce resistance.
Place in the numerator and in the denominator: .
- Electrical Analogy Check
In electrical resistance, , where is electrical conductivity.
Match thermal conductivity directly to electrical conductivity , giving .
CORRECTED PATH
ACEpath Teacher's DemonstrationRecalculate the thermal resistance of each layer: and .
Sum the series resistances: .
Find the total heat transfer rate: .
Compute the interface temperature: .
(a) (or ); (b) ()
02 The student averages the thermal conductivities of the two layers instead of combining their thermal resistances in series, leading to an incorrect equivalent conductivity and rate of heat transfer.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
Layers in series do not have an equivalent thermal conductivity equal to the simple arithmetic average of their conductivities. Heat must flow sequentially through both layers, meaning their thermal resistances add: .
- Step 2Correct
Your algebraic calculation is mathematically consistent with your , but the result is incorrect due to the invalid average conductivity.
- Step 3
- Step 4Correct
Your method of finding the interface temperature by subtracting the temperature drop from is completely sound, but it carries forward the erroneous value of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified and applied the single-layer conduction resistance formula .
You used the correct relationship between heat rate, thermal resistance, and interface temperature drop: .
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakenone
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated composite layers in series as if their thermal conductivities could be combined via a simple arithmetic mean. In reality, thermal conduction across consecutive layers follows the electrical circuit analogy where resistances in series add directly (), not conductivities.
REASONING PATH
Your ACEpath teacher’s suggested approach- Thermal Circuit Analogy for Series Layers
For conduction through composite plane layers in series, the same heat rate passes through every layer, so thermal resistances add: .
Never take an arithmetic average of thermal conductivities . Instead, find each individual layer resistance and sum them to obtain .
- Effective Conductivity vs. Arithmetic Average
If an equivalent conductivity is desired for series layers of equal area, it comes from equating resistances: .
Remember that series combination is a harmonic-style reciprocal combination of conductivities weighted by thickness, dominated by the layer with the highest thermal resistance.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate individual resistances: and .
Sum resistances in series: .
Compute total rate of heat transfer: .
Calculate interface temperature using your method: .
(a) (or ); (b) (or )
03 The student treats the two conductive layers as parallel heat paths by summing their conductances (1/R_tot = 1/R₁ + 1/R₂) rather than adding resistances in series.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Heat conducts sequentially through one layer and then the next, meaning the layers are in series rather than in parallel. You should add the resistances directly () rather than adding their reciprocals.
- Step 3Correct
Your formula for heat rate is correct, but your numerical result is affected by the incorrect total resistance from Step 2.
- Step 4Correct
Your method for finding the interface temperature from the temperature drop across the first layer is correct, but using the inflated resulted in a physically impossible negative temperature that is below .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the conduction thermal resistance for both individual material layers.
You applied the correct thermal Ohm's law relationship to find the heat transfer rate.
You set up the correct relationship between the interface temperature and the temperature drop across the first layer.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakenone
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated successive planar layers in a composite wall as a parallel thermal circuit instead of a series thermal circuit. In one-dimensional conduction perpendicular to flat layers, all heat must flow through each layer in sequence, which requires summing resistances directly: .
REASONING PATH
Your ACEpath teacher’s suggested approach- Check the Heat Flow Path
If the heat passes sequentially through layer A and then layer B, the layers are in series (). If the heat splits into side-by-side alternative paths, the layers are in parallel ().
Draw a heat flow arrow across the composite wall to verify whether the heat flow traverses the layers one after another or splits across them.
- Sanity Check Interface Temperatures
For steady-state conduction without heat generation, an intermediate interface temperature must lie strictly between the boundary temperatures: .
Verify that your calculated falls within the range . Getting is an immediate indicator of an underestimated total resistance.
CORRECTED PATH
ACEpath Teacher's DemonstrationAdd the two thermal resistances in series: .
Calculate the total heat transfer rate: .
Determine the interface temperature using the temperature drop across Layer 1: (or ).
(a) (or ); (b) ()
Lock it in
What is the formula for the conductive thermal resistance of a plane layer of thickness , thermal conductivity , and area ?
(Unit: or ). Memory cue: Thicker walls resist heat more ( on top), while high conductivity lets heat through ( on bottom).
Similar question
A single glass window pane has thermal conductivity , thickness , and area . Calculate its thermal resistance and the rate of heat loss when the inside surface is at and the outside surface is at .
Answer
. Rate of heat transfer: .
A two-layer composite wall consists of Layer A (, ) and Layer B (, ) with a cross-sectional area of . If the outer faces are held at and , find the interface temperature between Layer A and Layer B.
Answer
; . Total resistance . Heat flow . Interface temperature: .
A furnace wall has an inner brick layer (, ). An engineer wants to add an outer insulation layer () so that the total heat loss is reduced by for the same overall temperature difference across the wall. What thickness of insulation is required?
Answer
Reducing by means , so . Therefore, the insulation resistance must satisfy . Using , we have .