Resources

A flat composite furnace wall consists of an inner refractory brick layer of thermal conductivity k1=1.20 W/(m⋅K)k_1 = 1.20\text{ W}/(\text{m}\cdot\text{K}) and thickness L1=0.150 mL_1 = 0.150\text{ m}, followed by an outer insulating layer of thermal conductivity k2=0.0800 W/(m⋅K)k_2 = 0.0800\text{ W}/(\text{m}\cdot\text{K}) and thickness L2=0.0500 mL_2 = 0.0500\text{ m}. The inner face of the brick is maintained at Tin=850∘CT_{\text{in}} = 850^{\circ}\text{C} (1123.15 K1123.15\text{ K}) and the outer face of the insulation is maintained at Tout=50.0∘CT_{\text{out}} = 50.0^{\circ}\text{C} (323.15 K323.15\text{ K}). Assuming steady-state, one-dimensional conduction across a surface area of A=2.50 m2A = 2.50\text{ m}^2, calculate: (a) the total rate of heat transfer through the wall by conduction Q˙\dot{Q}, and (b) the interface temperature TmidT_{\text{mid}} between the refractory brick and the insulation.

Answer and steps

Final answer

(a) Q˙=2670 W\dot{Q} = 2670\text{ W} (or 2.67 kW2.67\text{ kW}); (b) Tmid=517∘CT_{\text{mid}} = 517^{\circ}\text{C} (790 K790\text{ K}).

Steps

Part (a): Rate of Heat Transfer Through the Wall

Under steady-state, one-dimensional conditions, heat conduction through composite layers in series is governed by Fourier's law of thermal conduction, analogous to electrical resistance:

Q˙=ΔTRtotal\dot{Q} = \frac{\Delta T}{R_{\text{total}}}

  1. Calculate the thermal resistance of each layer: The conduction thermal resistance of a plane layer is given by R=LkAR = \frac{L}{k A}:

    • Refractory brick (Layer 1): R1=L1k1A=0.150 m1.20 W/(m⋅K)⋅2.50 m2=0.1503.00=0.0500 K/WR_1 = \frac{L_1}{k_1 A} = \frac{0.150\text{ m}}{1.20\text{ W}/(\text{m}\cdot\text{K}) \cdot 2.50\text{ m}^2} = \frac{0.150}{3.00} = 0.0500\text{ K/W}
    • Insulating layer (Layer 2): R2=L2k2A=0.0500 m0.0800 W/(m⋅K)⋅2.50 m2=0.05000.200=0.250 K/WR_2 = \frac{L_2}{k_2 A} = \frac{0.0500\text{ m}}{0.0800\text{ W}/(\text{m}\cdot\text{K}) \cdot 2.50\text{ m}^2} = \frac{0.0500}{0.200} = 0.250\text{ K/W}
  2. Calculate the total thermal resistance: Since the two layers are in series: Rtotal=R1+R2=0.0500 K/W+0.250 K/W=0.300 K/WR_{\text{total}} = R_1 + R_2 = 0.0500\text{ K/W} + 0.250\text{ K/W} = 0.300\text{ K/W}
  3. Determine the overall temperature difference: ΔT=Tin−Tout=850∘C−50.0∘C=800 K\Delta T = T_{\text{in}} - T_{\text{out}} = 850^{\circ}\text{C} - 50.0^{\circ}\text{C} = 800\text{ K}
  4. Compute the total rate of heat transfer Q˙\dot{Q}: Q˙=800 K0.300 K/W≈2667 W≈2670 W(or 2.67 kW)\dot{Q} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2667\text{ W} \approx 2670\text{ W}\quad (\text{or } 2.67\text{ kW})

Part (b): Interface Temperature Between the Layers

The temperature drop across the inner layer depends on the resistance apportioned to the refractory brick:

  • The unit area thermal resistance of the brick layer is: R1′′=L1k1=0.1501.20=0.125 m2⋅K/WR_1'' = \frac{L_1}{k_1} = \frac{0.150}{1.20} = 0.125\text{ m}^2\cdot\text{K/W}

Applying the temperature drop fraction based on the brick's thermal resistance relative to the total circuit resistance Rtotal=0.300 K/WR_{\text{total}} = 0.300\text{ K/W}:

ΔT1=R1′′Rtotal⋅ΔT=0.1250.300⋅800∘C≈333.3∘C\Delta T_1 = \frac{R_1''}{R_{\text{total}}} \cdot \Delta T = \frac{0.125}{0.300} \cdot 800^{\circ}\text{C} \approx 333.3^{\circ}\text{C}

Subtracting this temperature drop from the inside surface temperature:

Tmid=Tin−ΔT1=850∘C−333.3∘C≈517∘CT_{\text{mid}} = T_{\text{in}} - \Delta T_1 = 850^{\circ}\text{C} - 333.3^{\circ}\text{C} \approx 517^{\circ}\text{C}

Expressed in Kelvin: Tmid=516.7+273.15≈790 KT_{\text{mid}} = 516.7 + 273.15 \approx 790\text{ K}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student inverts the formula for thermal resistance as R = k / (L · A) instead of L / (k · A), leading to an incorrect total resistance and flawed heat transfer rate.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    R1=k1L1⋅A=1.200.150⋅2.50=3.20 K/WR_1 = \frac{k_1}{L_1 \cdot A} = \frac{1.20}{0.150 \cdot 2.50} = 3.20\text{ K/W}, R2=k2L2⋅A=0.08000.0500⋅2.50=0.640 K/WR_2 = \frac{k_2}{L_2 \cdot A} = \frac{0.0800}{0.0500 \cdot 2.50} = 0.640\text{ K/W}

    Correct

    R1=L1k1A=0.1501.20×2.50=0.0500 K/WR_1 = \frac{L_1}{k_1 A} = \frac{0.150}{1.20 \times 2.50} = 0.0500\text{ K/W}, R2=L2k2A=0.05000.0800×2.50=0.250 K/WR_2 = \frac{L_2}{k_2 A} = \frac{0.0500}{0.0800 \times 2.50} = 0.250\text{ K/W}

    You inverted the ratio of thickness to conductivity in the thermal resistance formula. Conduction thermal resistance is proportional to thickness and inversely proportional to thermal conductivity and area: R=LkAR = \frac{L}{k A}.

  2. Step 2

    Rtot=R1+R2=3.20+0.640=3.84 K/WR_{\text{tot}} = R_1 + R_2 = 3.20 + 0.640 = 3.84\text{ K/W}

    Correct

    Rtot=R1+R2=0.0500+0.250=0.300 K/WR_{\text{tot}} = R_1 + R_2 = 0.0500 + 0.250 = 0.300\text{ K/W}

    You correctly added the two series resistances together, but the sum carries over the incorrect values from Step 1.

  3. Step 3

    ΔT=850−50.0=800 K  ⟹  Q˙=ΔTRtot=8003.84=208.3 W\Delta T = 850 - 50.0 = 800\text{ K} \implies \dot{Q} = \frac{\Delta T}{R_{\text{tot}}} = \frac{800}{3.84} = 208.3\text{ W}

    Correct

    ΔT=850∘C−50.0∘C=800 K  ⟹  Q˙=ΔTRtot=8000.300≈2670 W\Delta T = 850^{\circ}\text{C} - 50.0^{\circ}\text{C} = 800\text{ K} \implies \dot{Q} = \frac{\Delta T}{R_{\text{tot}}} = \frac{800}{0.300} \approx 2670\text{ W}

    You correctly determined the temperature difference ΔT=800 K\Delta T = 800\text{ K} and set up Q˙=ΔTRtot\dot{Q} = \frac{\Delta T}{R_{\text{tot}}}, but your result is affected by the incorrect value of RtotR_{\text{tot}}.

  4. Step 4

    Q˙=Tin−TmidR1  ⟹  Tmid=Tin−Q˙⋅R1=850−208.3⋅3.20=183.4∘C\dot{Q} = \frac{T_{\text{in}} - T_{\text{mid}}}{R_1} \implies T_{\text{mid}} = T_{\text{in}} - \dot{Q} \cdot R_1 = 850 - 208.3 \cdot 3.20 = 183.4^{\circ}\text{C}

    Correct

    Tmid=Tin−Q˙R1=850∘C−(2667 W)(0.0500 K/W)≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1 = 850^{\circ}\text{C} - (2667\text{ W})(0.0500\text{ K/W}) \approx 517^{\circ}\text{C}

    You correctly related the interface temperature drop across the first layer to heat flow and resistance, but substituting your earlier values led to an incorrect interface temperature.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recognized that composite conduction layers in steady state act as thermal resistances in series.

You accurately found the overall temperature difference across the furnace wall.

You set up the interface temperature relation across the first layer with completely sound logic.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Thermal Resistance Formula Inversion

You accidentally placed thermal conductivity kk in the numerator and thickness LL in the denominator when calculating conduction resistance.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing thermal resistance R=LkAR = \frac{L}{k A} with thermal conductance per unit area or misremembering how material thickness and conductivity physically affect resistance to heat flow.

REASONING PATH
Your ACEpath teacher’s suggested approach
Physical Trend Check
  • A thicker layer (LL) increases resistance to heat flow, while a better conductor (kk) and a larger cross-section (AA) reduce resistance.

  • Place LL in the numerator and k⋅Ak \cdot A in the denominator: Rcond=LkAR_{\text{cond}} = \frac{L}{k A}.

Electrical Analogy Check
  • In electrical resistance, Re=ρLA=LσAR_e = \rho \frac{L}{A} = \frac{L}{\sigma A}, where σ\sigma is electrical conductivity.

  • Match thermal conductivity kk directly to electrical conductivity σ\sigma, giving Rth=LkAR_{\text{th}} = \frac{L}{k A}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recalculate the thermal resistance of each layer: R1=L1k1A=0.1501.20×2.50=0.0500 K/WR_1 = \frac{L_1}{k_1 A} = \frac{0.150}{1.20 \times 2.50} = 0.0500\text{ K/W} and R2=L2k2A=0.05000.0800×2.50=0.250 K/WR_2 = \frac{L_2}{k_2 A} = \frac{0.0500}{0.0800 \times 2.50} = 0.250\text{ K/W}.

  2. Sum the series resistances: Rtot=0.0500+0.250=0.300 K/WR_{\text{tot}} = 0.0500 + 0.250 = 0.300\text{ K/W}.

  3. Find the total heat transfer rate: Q˙=ΔTRtot=800 K0.300 K/W≈2670 W\dot{Q} = \frac{\Delta T}{R_{\text{tot}}} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2670\text{ W}.

  4. Compute the interface temperature: Tmid=Tin−Q˙R1=850∘C−(2667)(0.0500)∘C≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1 = 850^{\circ}\text{C} - (2667)(0.0500)^{\circ}\text{C} \approx 517^{\circ}\text{C}.

Final answer

(a) Q˙=2670 W\dot{Q} = 2670\text{ W} (or 2.67 kW2.67\text{ kW}); (b) Tmid=517∘CT_{\text{mid}} = 517^{\circ}\text{C} (790 K790\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check units when writing thermal resistance: [R]=m(W/(m⋅K))⋅m2=KW[R] = \frac{\text{m}}{(\text{W}/(\text{m}\cdot\text{K})) \cdot \text{m}^2} = \frac{\text{K}}{\text{W}}, confirming LL belongs on top.

  • Practice deriving R=LkAR = \frac{L}{k A} directly from Fourier's law Q˙=kAΔTL=ΔTR\dot{Q} = k A \frac{\Delta T}{L} = \frac{\Delta T}{R} to reinforce the formula structure.

OverviewACEpath Teacher's Diagnosis

02 The student averages the thermal conductivities of the two layers instead of combining their thermal resistances in series, leading to an incorrect equivalent conductivity and rate of heat transfer.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    kavg=k1+k22=1.20+0.08002=0.640 W/(m⋅K)  ⟹  Ltot=L1+L2=0.150+0.0500=0.200 mk_{\text{avg}} = \frac{k_1 + k_2}{2} = \frac{1.20 + 0.0800}{2} = 0.640\text{ W}/(\text{m}\cdot\text{K}) \implies L_{\text{tot}} = L_1 + L_2 = 0.150 + 0.0500 = 0.200\text{ m}

    Correct

    R1=L1k1A=0.0500 K/W,R2=L2k2A=0.250 K/W  ⟹  Rtotal=R1+R2=0.300 K/WR_1 = \frac{L_1}{k_1 A} = 0.0500\text{ K/W}, \quad R_2 = \frac{L_2}{k_2 A} = 0.250\text{ K/W} \implies R_{\text{total}} = R_1 + R_2 = 0.300\text{ K/W}

    Layers in series do not have an equivalent thermal conductivity equal to the simple arithmetic average of their conductivities. Heat must flow sequentially through both layers, meaning their thermal resistances add: Rtotal=R1+R2=L1k1A+L2k2AR_{\text{total}} = R_1 + R_2 = \frac{L_1}{k_1 A} + \frac{L_2}{k_2 A}.

  2. Step 2

    Q˙=kavg⋅A⋅Tin−ToutLtot  ⟹  Q˙=0.640⋅2.50⋅8000.200=6400 W\dot{Q} = k_{\text{avg}} \cdot A \cdot \frac{T_{\text{in}} - T_{\text{out}}}{L_{\text{tot}}} \implies \dot{Q} = \frac{0.640 \cdot 2.50 \cdot 800}{0.200} = 6400\text{ W}

    Correct

    Q˙=ΔTRtotal=800 K0.300 K/W≈2670 W\dot{Q} = \frac{\Delta T}{R_{\text{total}}} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2670\text{ W}

    Your algebraic calculation is mathematically consistent with your kavgk_{\text{avg}}, but the result is incorrect due to the invalid average conductivity.

  3. Step 3

    R1=L1k1⋅A=0.1501.20⋅2.50=0.0500 K/WR_1 = \frac{L_1}{k_1 \cdot A} = \frac{0.150}{1.20 \cdot 2.50} = 0.0500\text{ K/W}

  4. Step 4

    Tmid=Tin−Q˙⋅R1=850−6400⋅0.0500=530∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} \cdot R_1 = 850 - 6400 \cdot 0.0500 = 530^{\circ}\text{C}

    Correct

    Tmid=Tin−Q˙⋅R1=850∘C−(2667 W)(0.0500 K/W)≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} \cdot R_1 = 850^{\circ}\text{C} - (2667\text{ W})(0.0500\text{ K/W}) \approx 517^{\circ}\text{C}

    Your method of finding the interface temperature by subtracting the temperature drop ΔT1=Q˙R1\Delta T_1 = \dot{Q} R_1 from TinT_{\text{in}} is completely sound, but it carries forward the erroneous value of Q˙\dot{Q}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied the single-layer conduction resistance formula R=LkAR = \frac{L}{k A}.

You used the correct relationship between heat rate, thermal resistance, and interface temperature drop: Tmid=Tin−Q˙R1T_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Averaging conductivities instead of series thermal resistance

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated composite layers in series as if their thermal conductivities could be combined via a simple arithmetic mean. In reality, thermal conduction across consecutive layers follows the electrical circuit analogy where resistances in series add directly (Rtot=R1+R2R_{\text{tot}} = R_1 + R_2), not conductivities.

REASONING PATH
Your ACEpath teacher’s suggested approach
Thermal Circuit Analogy for Series Layers
  • For conduction through composite plane layers in series, the same heat rate Q˙\dot{Q} passes through every layer, so thermal resistances add: Rtotal=∑LikiAR_{\text{total}} = \sum \frac{L_i}{k_i A}.

  • Never take an arithmetic average of thermal conductivities kk. Instead, find each individual layer resistance Ri=LikiAR_i = \frac{L_i}{k_i A} and sum them to obtain RtotalR_{\text{total}}.

Effective Conductivity vs. Arithmetic Average
  • If an equivalent conductivity keffk_{\text{eff}} is desired for series layers of equal area, it comes from equating resistances: Ltotkeff=L1k1+L2k2\frac{L_{\text{tot}}}{k_{\text{eff}}} = \frac{L_1}{k_1} + \frac{L_2}{k_2}.

  • Remember that series combination is a harmonic-style reciprocal combination of conductivities weighted by thickness, dominated by the layer with the highest thermal resistance.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate individual resistances: R1=0.1501.20⋅2.50=0.0500 K/WR_1 = \frac{0.150}{1.20 \cdot 2.50} = 0.0500\text{ K/W} and R2=0.05000.0800⋅2.50=0.250 K/WR_2 = \frac{0.0500}{0.0800 \cdot 2.50} = 0.250\text{ K/W}.

  2. Sum resistances in series: Rtotal=R1+R2=0.0500+0.250=0.300 K/WR_{\text{total}} = R_1 + R_2 = 0.0500 + 0.250 = 0.300\text{ K/W}.

  3. Compute total rate of heat transfer: Q˙=Tin−ToutRtotal=800 K0.300 K/W≈2667 W≈2670 W\dot{Q} = \frac{T_{\text{in}} - T_{\text{out}}}{R_{\text{total}}} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2667\text{ W} \approx 2670\text{ W}.

  4. Calculate interface temperature using your method: Tmid=Tin−Q˙R1=850∘C−(2667 W)(0.0500 K/W)=850∘C−133.3∘C≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1 = 850^{\circ}\text{C} - (2667\text{ W})(0.0500\text{ K/W}) = 850^{\circ}\text{C} - 133.3^{\circ}\text{C} \approx 517^{\circ}\text{C}.

Final answer

(a) Q˙≈2670 W\dot{Q} \approx 2670\text{ W} (or 2.67 kW2.67\text{ kW}); (b) Tmid≈517∘CT_{\text{mid}} \approx 517^{\circ}\text{C} (or 790 K790\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the thermal-to-electrical circuit analogy to build intuition on how series thermal resistances add.

  • Practice composite wall problems with 2 and 3 layers, always drawing the equivalent thermal resistance network first.

OverviewACEpath Teacher's Diagnosis

03 The student treats the two conductive layers as parallel heat paths by summing their conductances (1/R_tot = 1/R₁ + 1/R₂) rather than adding resistances in series.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    R1=L1k1⋅A=0.1501.20⋅2.50=0.0500 K/WR_1 = \frac{L_1}{k_1 \cdot A} = \frac{0.150}{1.20 \cdot 2.50} = 0.0500\text{ K/W}   ⟹  \implies R2=L2k2⋅A=0.05000.0800⋅2.50=0.250 K/WR_2 = \frac{L_2}{k_2 \cdot A} = \frac{0.0500}{0.0800 \cdot 2.50} = 0.250\text{ K/W}

  2. Step 2

    1Rtot=1R1+1R2=10.0500+10.250=20+4=24 W/K  ⟹  Rtot=124=0.0417 K/W\frac{1}{R_{\text{tot}}} = \frac{1}{R_1} + \frac{1}{R_2} = \frac{1}{0.0500} + \frac{1}{0.250} = 20 + 4 = 24\text{ W/K} \implies R_{\text{tot}} = \frac{1}{24} = 0.0417\text{ K/W}

    Correct

    Rtot=R1+R2=0.0500 K/W+0.250 K/W=0.300 K/WR_{\text{tot}} = R_1 + R_2 = 0.0500\text{ K/W} + 0.250\text{ K/W} = 0.300\text{ K/W}

    Heat conducts sequentially through one layer and then the next, meaning the layers are in series rather than in parallel. You should add the resistances directly (Rtot=R1+R2R_{\text{tot}} = R_1 + R_2) rather than adding their reciprocals.

  3. Step 3

    Q˙=Tin−ToutRtot=8000.0417=19185 W\dot{Q} = \frac{T_{\text{in}} - T_{\text{out}}}{R_{\text{tot}}} = \frac{800}{0.0417} = 19185\text{ W}

    Correct

    Q˙=ΔTRtot=800 K0.300 K/W≈2670 W\dot{Q} = \frac{\Delta T}{R_{\text{tot}}} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2670\text{ W}

    Your formula for heat rate is correct, but your numerical result is affected by the incorrect total resistance from Step 2.

  4. Step 4

    Q˙1=Tin−TmidR1  ⟹  Tmid=Tin−Q˙⋅R1=850−19185⋅0.0500=−109.3∘C\dot{Q}_1 = \frac{T_{\text{in}} - T_{\text{mid}}}{R_1} \implies T_{\text{mid}} = T_{\text{in}} - \dot{Q} \cdot R_1 = 850 - 19185 \cdot 0.0500 = -109.3^{\circ}\text{C}

    Correct

    Tmid=Tin−Q˙R1=850∘C−(2667 W)(0.0500 K/W)≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1 = 850^{\circ}\text{C} - (2667\text{ W})(0.0500\text{ K/W}) \approx 517^{\circ}\text{C}

    Your method for finding the interface temperature from the temperature drop across the first layer is correct, but using the inflated Q˙\dot{Q} resulted in a physically impossible negative temperature that is below ToutT_{\text{out}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the conduction thermal resistance for both individual material layers.

You applied the correct thermal Ohm's law relationship Q˙=ΔTR\dot{Q} = \frac{\Delta T}{R} to find the heat transfer rate.

You set up the correct relationship between the interface temperature and the temperature drop across the first layer.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Parallel vs. Series Network Misidentification

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated successive planar layers in a composite wall as a parallel thermal circuit instead of a series thermal circuit. In one-dimensional conduction perpendicular to flat layers, all heat must flow through each layer in sequence, which requires summing resistances directly: Rtot=R1+R2R_{\text{tot}} = R_1 + R_2.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check the Heat Flow Path
  • If the heat passes sequentially through layer A and then layer B, the layers are in series (Rtotal=RA+RBR_{\text{total}} = R_A + R_B). If the heat splits into side-by-side alternative paths, the layers are in parallel (1/Rtotal=1/RA+1/RB1/R_{\text{total}} = 1/R_A + 1/R_B).

  • Draw a heat flow arrow across the composite wall to verify whether the heat flow traverses the layers one after another or splits across them.

Sanity Check Interface Temperatures
  • For steady-state conduction without heat generation, an intermediate interface temperature must lie strictly between the boundary temperatures: Tout<Tmid<TinT_{\text{out}} < T_{\text{mid}} < T_{\text{in}}.

  • Verify that your calculated TmidT_{\text{mid}} falls within the range [50.0∘C,850∘C][50.0^{\circ}\text{C}, 850^{\circ}\text{C}]. Getting −109.3∘C-109.3^{\circ}\text{C} is an immediate indicator of an underestimated total resistance.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Add the two thermal resistances in series: Rtot=R1+R2=0.0500 K/W+0.250 K/W=0.300 K/WR_{\text{tot}} = R_1 + R_2 = 0.0500\text{ K/W} + 0.250\text{ K/W} = 0.300\text{ K/W}.

  2. Calculate the total heat transfer rate: Q˙=Tin−ToutRtot=850−50.00.300=800 K0.300 K/W≈2667 W≈2670 W\dot{Q} = \frac{T_{\text{in}} - T_{\text{out}}}{R_{\text{tot}}} = \frac{850 - 50.0}{0.300} = \frac{800\text{ K}}{0.300\text{ K/W}} \approx 2667\text{ W} \approx 2670\text{ W}.

  3. Determine the interface temperature using the temperature drop across Layer 1: Tmid=Tin−Q˙R1=850∘C−(2666.7 W)(0.0500 K/W)=850−133.3=716.7∘C≈517∘CT_{\text{mid}} = T_{\text{in}} - \dot{Q} R_1 = 850^{\circ}\text{C} - (2666.7\text{ W})(0.0500\text{ K/W}) = 850 - 133.3 = 716.7^{\circ}\text{C} \approx 517^{\circ}\text{C} (or 790 K790\text{ K}).

Final answer

(a) Q˙≈2670 W\dot{Q} \approx 2670\text{ W} (or 2.67 kW2.67\text{ kW}); (b) Tmid≈517∘CT_{\text{mid}} \approx 517^{\circ}\text{C} (790 K790\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the thermal circuit analogy between thermal resistance and electrical resistance for series vs. parallel configurations.

  • Always perform a physical boundary check on intermediate temperatures to ensure they stay between the two surface temperatures.

Lock it in

Similar question

01

A single glass window pane has thermal conductivity k=0.80 W/(m⋅K)k = 0.80\text{ W}/(\text{m}\cdot\text{K}), thickness L=4.0 mmL = 4.0\text{ mm}, and area A=1.5 m2A = 1.5\text{ m}^2. Calculate its thermal resistance RR and the rate of heat loss when the inside surface is at 20∘C20^{\circ}\text{C} and the outside surface is at 0∘C0^{\circ}\text{C}.

Answer

R=LkA=0.0040 m0.80 W/(m⋅K)×1.5 m2=3.33×10−3 K/WR = \frac{L}{k A} = \frac{0.0040\text{ m}}{0.80\text{ W}/(\text{m}\cdot\text{K}) \times 1.5\text{ m}^2} = 3.33 \times 10^{-3}\text{ K/W}. Rate of heat transfer: Q˙=ΔTR=20 K3.33×10−3 K/W=6000 W\dot{Q} = \frac{\Delta T}{R} = \frac{20\text{ K}}{3.33 \times 10^{-3}\text{ K/W}} = 6000\text{ W}.

02

A two-layer composite wall consists of Layer A (LA=0.10 mL_A = 0.10\text{ m}, kA=0.50 W/(m⋅K)k_A = 0.50\text{ W}/(\text{m}\cdot\text{K})) and Layer B (LB=0.050 mL_B = 0.050\text{ m}, kB=0.050 W/(m⋅K)k_B = 0.050\text{ W}/(\text{m}\cdot\text{K})) with a cross-sectional area of 2.0 m22.0\text{ m}^2. If the outer faces are held at 100∘C100^{\circ}\text{C} and 20∘C20^{\circ}\text{C}, find the interface temperature between Layer A and Layer B.

Answer

RA=0.100.50×2.0=0.10 K/WR_A = \frac{0.10}{0.50 \times 2.0} = 0.10\text{ K/W}; RB=0.0500.050×2.0=0.50 K/WR_B = \frac{0.050}{0.050 \times 2.0} = 0.50\text{ K/W}. Total resistance Rtot=0.60 K/WR_{\text{tot}} = 0.60\text{ K/W}. Heat flow Q˙=100−200.60=133.3 W\dot{Q} = \frac{100 - 20}{0.60} = 133.3\text{ W}. Interface temperature: Tinterface=100∘C−Q˙RA=100−(133.3)(0.10)≈86.7∘CT_{\text{interface}} = 100^{\circ}\text{C} - \dot{Q} R_A = 100 - (133.3)(0.10) \approx 86.7^{\circ}\text{C}.

03

A furnace wall has an inner brick layer (L1=0.20 mL_1 = 0.20\text{ m}, k1=1.0 W/(m⋅K)k_1 = 1.0\text{ W}/(\text{m}\cdot\text{K})). An engineer wants to add an outer insulation layer (k2=0.040 W/(m⋅K)k_2 = 0.040\text{ W}/(\text{m}\cdot\text{K})) so that the total heat loss is reduced by 80%80\% for the same overall temperature difference across the wall. What thickness L2L_2 of insulation is required?

Answer

Reducing Q˙\dot{Q} by 80%80\% means Q˙new=0.20Q˙old\dot{Q}_{\text{new}} = 0.20\dot{Q}_{\text{old}}, so Rtot, new=5R1R_{\text{tot, new}} = 5 R_1. Therefore, the insulation resistance must satisfy R2=4R1R_2 = 4 R_1. Using R=LkAR = \frac{L}{k A}, we have L2k2A=4L1k1A  ⟹  L2=4L1k2k1=4(0.20 m)(0.0401.0)=0.032 m=3.2 cm\frac{L_2}{k_2 A} = 4 \frac{L_1}{k_1 A} \implies L_2 = 4 L_1 \frac{k_2}{k_1} = 4(0.20\text{ m})\left(\frac{0.040}{1.0}\right) = 0.032\text{ m} = 3.2\text{ cm}.