Resources
Two independent laboratory groups measure the speed of sound in air at room temperature using resonance tubes. Group A reports , and Group B reports . The standard experimental threshold for compatibility between two independent measurements is , where . Calculate the difference , the combined uncertainty , and the discrepancy ratio . Determine whether the two measurements are statistically consistent at the threshold.
Answer and steps
Final answer
, , ; the measurements are not statistically consistent at the threshold because .
Steps
Calculate the difference between the two measurements
Subtract the measured value of Group B from that of Group A:
The absolute discrepancy between the two independent experimental values is:
Determine the combined standard uncertainty ()
When comparing two independent measurements, their uncertainties combine in quadrature rather than by direct addition. Using the given formula:
Substitute the reported uncertainties and :
Common Pitfall: Do not simply add uncertainties linearly () or subtract them. For independent, normally distributed random uncertainties, the variance of the difference is the sum of the individual variances.
Compute the discrepancy ratio (-score)
The discrepancy ratio indicates how many standard deviations the observed difference lies from zero:
Evaluate statistical consistency
Check the standard experimental criterion for compatibility at the threshold:
- Observed discrepancy:
- Threshold limit:
Since (or equivalently, ), the difference exceeds the accepted boundary. Therefore, the two measurements are not statistically consistent at the threshold.
Typical errors
01 The student linearly adds the individual uncertainties instead of combining them in quadrature, resulting in σ_diff = 2.8 m/s and concluding the measurements are consistent.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You directly added the individual standard deviations linearly. For independent measurements, random uncertainties combine in quadrature via the square root of the sum of squares.
- Step 3Correct
Your division setup is mathematically correct, but the value is affected by the incorrect value of from Step 2.
- Step 4Correct
Because your calculated -score was underestimated due to the inflated uncertainty, you reached the opposite consistency conclusion.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the numerical difference between the two measured speeds.
You correctly identified the definition of the -score as the discrepancy divided by the combined uncertainty.
You applied the decision rule accurately to your computed value.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou added random standard uncertainties linearly rather than adding their variances in quadrature as required for independent variables.
REASONING PATH
Your ACEpath teacher’s suggested approach- Uncertainty Propagation for Independent Differences
For independent random variables and , the standard deviation of their sum or difference is , never .
Always square each individual standard uncertainty, sum the squares, and take the square root.
CORRECTED PATH
ACEpath Teacher's DemonstrationCombine the independent standard uncertainties in quadrature: .
Recalculate the discrepancy ratio: .
Evaluate consistency against the threshold: since , the difference exceeds .
, , ; the measurements are not statistically consistent at the threshold.
02 The student subtracts the uncertainties because the primary values are subtracted, resulting in an underestimated uncertainty of 0.4 m/s.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You subtracted the squared uncertainties instead of adding them in quadrature. Even when taking a difference between two quantities, independent random uncertainties always combine by adding variances: .
- Step 3Correct
Your division step correctly set up the ratio , but the numerical value was affected by your earlier error in .
- Step 4Correct
You applied the correct comparison rule (), though your numerical threshold comparison relied on the incorrect -score.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the experimental difference between the two measurements.
You used the correct ratio formula to compare the discrepancy to the combined uncertainty.
You correctly interpreted the decision threshold to make your final conclusion.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou associated the subtraction in the primary values with subtraction inside the error propagation formula, forgetting that independent random errors always add in quadrature regardless of whether variables are added or subtracted.
REASONING PATH
Your ACEpath teacher’s suggested approach- Addition in Quadrature
For any linear combination with independent uncertainties, .
Always add the squares of independent uncertainties under the square root, never subtract them.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the combined standard uncertainty by summing the variances: .
Recalculate the discrepancy ratio: .
Compare with the compatibility threshold: since , the two results are not statistically consistent at the level.
, , ; the measurements are not statistically consistent at the threshold because .
03 The student misinterprets the 2σ threshold as requiring t ≥ 2 for compatibility, falsely concluding that the measurements are consistent.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
- Step 4Correct
You reversed the inequality condition for compatibility. Compatibility requires the discrepancy to fall within the uncertainty limit ( or ). Because , the difference is too large to be explained by random error alone at this threshold.
WHAT YOU DID WELL
Compliments from Your TeacherYou found the exact difference between the two experimental values.
You correctly combined the independent uncertainties in quadrature.
You calculated the discrepancy ratio accurately.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the threshold as a minimum score to achieve compatibility rather than an upper bound on acceptable discrepancy.
REASONING PATH
Your ACEpath teacher’s suggested approach- Meaning of Discrepancy Ratio $t$
The ratio measures how many standard deviations separate two measurements. A smaller means closer agreement.
Check whether for an compatibility test. If , the discrepancy exceeds the allowed threshold, meaning the results disagree.
CORRECTED PATH
ACEpath Teacher's DemonstrationCompare the computed ratio to the threshold: .
Conclude that the discrepancy exceeds the compatibility boundary.
The two measurements are not statistically consistent at the threshold because .
Lock it in
How do independent random standard uncertainties and combine when computing the uncertainty of ?
. Independent random errors combine in quadrature (root-sum-of-squares), not by direct addition.
Similar question
Two lab groups measure the local acceleration due to gravity. Group 1 reports and Group 2 reports . Calculate the combined uncertainty and determine whether the two measurements are consistent at the threshold ().
Answer
. Discrepancy . Discrepancy ratio . Since , the measurements are statistically consistent.
A student measures the length of a metal rod before and after heating. The initial length is and the final length is . Find the elongation , its combined standard uncertainty , and state whether the expansion is statistically distinguishable from zero at the level ().
Answer
. The combined uncertainty is . The discrepancy ratio from zero is . Since , the expansion is not statistically distinguishable from zero at the level.
Two independent methods determine the focal length of a convex lens: Method A gives and Method B gives . Calculate the discrepancy ratio and evaluate whether the discrepancy indicates a potential systematic error at the standard compatibility threshold.
Answer
Difference . Combined uncertainty . Discrepancy ratio . Since , the difference is within normal random fluctuation and does not provide evidence of systematic error at the threshold.