Resources

In a Young's double-slit experiment, monochromatic light with a wavelength of λ=532 nm\lambda = 532\text{ nm} illuminates two parallel narrow slits separated by a distance of d=0.180 mmd = 0.180\text{ mm}. The resulting interference pattern is observed on a flat viewing screen positioned parallel to the slit plane at a distance of L=1.65 mL = 1.65\text{ m}. Assuming small-angle approximations hold, calculate the linear distance y3y_3 on the screen from the central maximum to the center of the third-order (m=3m = 3) bright fringe.

Answer and steps

Final answer

1.46×10−2 m1.46\times 10^{-2}\text{ m} (or 1.46 cm1.46\text{ cm})

Steps

01

Identify the condition for bright fringes (maxima)

To find the distance from the central maximum to the third-order bright fringe, we use the condition for constructive interference in Young's double-slit experiment.

Bright fringes occur when the path difference between light waves arriving from the two slits is an integer multiple of the wavelength λ\lambda: dsin⁡θ=mλd \sin\theta = m\lambda

where:

  • d=0.180 mm=1.80×10−4 md = 0.180\text{ mm} = 1.80\times 10^{-4}\text{ m} is the slit separation,
  • θ\theta is the angle between the central axis and the line pointing to the fringe,
  • mm is the fringe order (m=3m = 3 for the third-order bright fringe),
  • λ=532 nm=532×10−9 m\lambda = 532\text{ nm} = 532\times 10^{-9}\text{ m} is the wavelength of the light.
02

Apply the small-angle approximation

Since the screen distance L=1.65 mL = 1.65\text{ m} is much larger than the slit separation dd and the expected fringe positions, the angular deviation θ\theta is very small. Under the small-angle approximation (sin⁡θ≈tan⁡θ\sin\theta \approx \tan\theta): sin⁡θ≈tan⁡θ=ymL\sin\theta \approx \tan\theta = \frac{y_m}{L}

where ymy_m is the linear distance on the screen from the central maximum (m=0m = 0) to the mm-th fringe.

Substituting this approximation into the interference equation gives: d(ymL)=mλd\left(\frac{y_m}{L}\right) = m\lambda

Solving for ymy_m: ym=mλLdy_m = \frac{m\lambda L}{d}

03

Calculate the linear position y3y_3

Substitute the given values for the third-order maximum (m=3m = 3): y3=3⋅(532×10−9 m)⋅1.65 m1.80×10−4 my_3 = \frac{3 \cdot (532\times 10^{-9}\text{ m}) \cdot 1.65\text{ m}}{1.80\times 10^{-4}\text{ m}}

Multiplying the numerator: 3⋅(532×10−9 m)⋅1.65 m=2.6334×10−6 m23 \cdot (532\times 10^{-9}\text{ m}) \cdot 1.65\text{ m} = 2.6334\times 10^{-6}\text{ m}^2

Dividing by dd: y3=2.6334×10−6 m21.80×10−4 m≈1.463×10−2 my_3 = \frac{2.6334\times 10^{-6}\text{ m}^2}{1.80\times 10^{-4}\text{ m}} \approx 1.463\times 10^{-2}\text{ m}

Rounding to three significant figures gives: y3=1.46×10−2 m(or 1.46 cm)y_3 = 1.46\times 10^{-2}\text{ m}\quad (\text{or } 1.46\text{ cm})

(Pitfall to avoid: Ensure all quantities are converted to standard SI units—meters—before calculating, particularly converting nanometers (10−9 m10^{-9}\text{ m}) and millimeters (10−3 m10^{-3}\text{ m}).)

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert the slit separation d from millimeters to meters, resulting in a calculated fringe distance that is off by a factor of 10^3.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    y3=mλLdy_3 = \frac{m \lambda L}{d}

  2. Step 2

    λ=532×10−9 m,  L=1.65 m,  d=0.180 m\lambda = 532 \times 10^{-9}\text{ m},\; L = 1.65\text{ m},\; d = 0.180\text{ m}

    Correct

    λ=532×10−9 m,  L=1.65 m,  d=0.180 mm=1.80×10−4 m\lambda = 532 \times 10^{-9}\text{ m},\; L = 1.65\text{ m},\; d = 0.180\text{ mm} = 1.80 \times 10^{-4}\text{ m}

    You correctly converted nanometers to meters for λ\lambda, but you dropped the milli- prefix on dd, writing 0.180 m0.180\text{ m} instead of 0.180×10−3 m0.180 \times 10^{-3}\text{ m} (1.80×10−4 m1.80 \times 10^{-4}\text{ m}).

  3. Step 3

    y3=3×532×10−9×1.650.180y_3 = \frac{3 \times 532 \times 10^{-9} \times 1.65}{0.180}

    Correct

    y3=3×(532×10−9 m)×1.65 m1.80×10−4 my_3 = \frac{3 \times (532 \times 10^{-9}\text{ m}) \times 1.65\text{ m}}{1.80 \times 10^{-4}\text{ m}}

    You substituted your listed values into the equation correctly, but the denominator carried over the unconverted value of dd.

  4. Step 4

    y3=1.46×10−5 my_3 = 1.46 \times 10^{-5}\text{ m}

    Correct

    y3=1.46×10−2 m (or 1.46 cm)y_3 = 1.46 \times 10^{-2}\text{ m}\text{ (or } 1.46\text{ cm)}

    Your arithmetic evaluation was consistent with your substituted values, but due to the unit error in dd, the result is off by a factor of 10310^3.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied the bright fringe position equation ym=mλLdy_m = \frac{m\lambda L}{d}.

You properly converted the wavelength from nanometers to meters as 532×10−9 m532 \times 10^{-9}\text{ m}.

You carried out the arithmetic with the correct number of significant figures.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion omission

You omitted the conversion factor 10−310^{-3} when converting the slit separation dd from millimeters to meters.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You overlooked the metric prefix 'milli-' (1 mm=10−3 m1\text{ mm} = 10^{-3}\text{ m}) while listing the given values, treating the numerical value 0.1800.180 as if it were already in meters.

REASONING PATH
Your ACEpath teacher’s suggested approach
Metric prefix audit
  • Every parameter must be converted to base SI units (meters for distance) before substituting into wave formulas: 1 nm=10−9 m1\text{ nm} = 10^{-9}\text{ m}, 1 μm=10−6 m1\,\mu\text{m} = 10^{-6}\text{ m}, 1 mm=10−3 m1\text{ mm} = 10^{-3}\text{ m}.

  • Circle every unit in the problem statement during your first read and explicitly write the power of ten beside each variable.

Physical scale check
  • Slit separation dd in double-slit setups is typically a fraction of a millimeter (10−4 m10^{-4}\text{ m} to 10−3 m10^{-3}\text{ m}), whereas visible bright fringes on a screen at L∼1–2 mL \sim 1\text{–}2\text{ m} are spaced by millimeters or centimeters (10−3 m10^{-3}\text{ m} to 10−2 m10^{-2}\text{ m}).

  • Compare your calculated fringe distance to typical lab values: a fringe distance of 10−5 m10^{-5}\text{ m} (10 μm10\,\mu\text{m}) is far too small to observe with the naked eye.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert slit separation to base SI units: d=0.180 mm=0.180×10−3 m=1.80×10−4 md = 0.180\text{ mm} = 0.180 \times 10^{-3}\text{ m} = 1.80 \times 10^{-4}\text{ m}.

  2. Substitute all SI values into the fringe formula: y3=3×(532×10−9 m)×1.65 m1.80×10−4 my_3 = \frac{3 \times (532 \times 10^{-9}\text{ m}) \times 1.65\text{ m}}{1.80 \times 10^{-4}\text{ m}}.

  3. Evaluate the numerator: 3×(532×10−9)×1.65=2.6334×10−6 m23 \times (532 \times 10^{-9}) \times 1.65 = 2.6334 \times 10^{-6}\text{ m}^2.

  4. Divide by dd: y3=2.6334×10−6 m21.80×10−4 m≈1.463×10−2 my_3 = \frac{2.6334 \times 10^{-6}\text{ m}^2}{1.80 \times 10^{-4}\text{ m}} \approx 1.463 \times 10^{-2}\text{ m}.

Final answer

1.46×10−2 m (or 1.46 cm)1.46 \times 10^{-2}\text{ m}\text{ (or } 1.46\text{ cm)}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review metric prefixes commonly found in optics problems, focusing on millimeters (10−310^{-3}), micrometers (10−610^{-6}), and nanometers (10−910^{-9}).

  • Practice checking whether your final fringe spacing falls within an expected laboratory range (typically millimeters to centimeters).

OverviewACEpath Teacher's Diagnosis

02 The student misremembers the double-slit interference relationship by placing the slit separation in the numerator and the screen distance in the denominator, leading to an inverted geometric ratio.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    y3=mλdLy_3 = \frac{m\lambda d}{L}

    Correct

    y3=mλLdy_3 = \frac{m\lambda L}{d}

    You placed dd in the numerator and LL in the denominator. Starting from the interference condition dsin⁡θ=mλd\sin\theta = m\lambda and the small-angle approximation sin⁡θ≈yL\sin\theta \approx \frac{y}{L}, solving for fringe distance gives d(yL)=mλ  ⟹  y=mλLdd\left(\frac{y}{L}\right) = m\lambda \implies y = \frac{m\lambda L}{d}.

  2. Step 2

    λ=532×10−9 m, d=1.80×10−4 m, L=1.65 m\lambda = 532\times 10^{-9}\text{ m},\ d = 1.80\times 10^{-4}\text{ m},\ L = 1.65\text{ m}

  3. Step 3

    y3=3×532×10−9×1.80×10−41.65  ⟹  y3=1.74×10−10 my_3 = \frac{3\times 532\times 10^{-9}\times 1.80\times 10^{-4}}{1.65} \implies y_3 = 1.74\times 10^{-10}\text{ m}

    Correct

    y3=3×(532×10−9 m)×1.65 m1.80×10−4 m=1.46×10−2 my_3 = \frac{3\times (532\times 10^{-9}\text{ m})\times 1.65\text{ m}}{1.80\times 10^{-4}\text{ m}} = 1.46\times 10^{-2}\text{ m}

    Your numerical evaluation is mathematically consistent with your written formula, but the result is incorrect because dd and LL were swapped in Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted all physical quantities into standard SI units.

You accurately identified the fringe order m=3m = 3 for the third-order bright fringe.

You carried out the arithmetic evaluation without calculation slips.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula Rearrangement Error

You accidentally swapped the slit separation dd and the screen distance LL when writing the linear fringe separation formula.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Deriving linear fringe position from memory rather than algebraically isolating yy from d(yL)=mλd\left(\frac{y}{L}\right) = m\lambda, leading to an inverted geometric ratio dL\frac{d}{L} instead of Ld\frac{L}{d}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional and Physical Sense Check
  • Fringe spacing must scale directly with distance to screen (y∝Ly \propto L) and inversely with slit width (y∝1dy \propto \frac{1}{d}).

  • Always verify that moving the screen farther (L↑L \uparrow) increases fringe spread (y↑y \uparrow), placing LL in the numerator.

Two-Step Derivation
  • Start from basic principles: dsin⁡θ=mλd\sin\theta = m\lambda and tan⁡θ≈yL\tan\theta \approx \frac{y}{L}.

  • Equate d(yL)=mλd\left(\frac{y}{L}\right) = m\lambda, then multiply both sides by LL and divide by dd to obtain y=mλLdy = \frac{m\lambda L}{d}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. State the small-angle constructive interference relation: d(ymL)=mλd\left(\frac{y_m}{L}\right) = m\lambda.

  2. Isolate ymy_m by multiplying by LL and dividing by dd: ym=mλLdy_m = \frac{m\lambda L}{d}.

  3. Substitute m=3m = 3, λ=532×10−9 m\lambda = 532\times 10^{-9}\text{ m}, L=1.65 mL = 1.65\text{ m}, and d=1.80×10−4 md = 1.80\times 10^{-4}\text{ m}:

  4. y3=3⋅(532×10−9 m)⋅1.65 m1.80×10−4 m=2.6334×10−6 m21.80×10−4 m=1.463×10−2 my_3 = \frac{3\cdot (532\times 10^{-9}\text{ m})\cdot 1.65\text{ m}}{1.80\times 10^{-4}\text{ m}} = \frac{2.6334\times 10^{-6}\text{ m}^2}{1.80\times 10^{-4}\text{ m}} = 1.463\times 10^{-2}\text{ m}

Final answer

1.46×10−2 m1.46\times 10^{-2}\text{ m} (or 1.46 cm1.46\text{ cm})

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice deriving y=mλLdy = \frac{m\lambda L}{d} from dsin⁡θ=mλd\sin\theta = m\lambda and sin⁡θ≈yL\sin\theta \approx \frac{y}{L} rather than memorizing the final formula.

  • Perform a physical sanity check on units and scales: a sub-atomic fringe separation of ∼10−10 m\sim 10^{-10}\text{ m} indicates an inverted macroscopic distance ratio.

OverviewACEpath Teacher's Diagnosis

03 The student confuses the condition for bright fringes with the condition for dark fringes (destructive interference) by using m + 1/2 instead of m.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    y3=(m+12)λLdy_3 = \left(m + \frac{1}{2}\right) \frac{\lambda L}{d}

    Correct

    ym=mλLdy_m = \frac{m\lambda L}{d}

    You used the formula for a dark fringe (destructive interference minimum). Bright fringes occur where constructive interference happens, which requires an integer number of wavelengths: dsin⁡θ=mλd \sin\theta = m\lambda, giving ym=mλLdy_m = \frac{m\lambda L}{d}.

  2. Step 2

    y3=3.5×532×10−9×1.650.180×10−3  ⟹  y3=1.71×10−2 my_3 = \frac{3.5 \times 532 \times 10^{-9} \times 1.65}{0.180 \times 10^{-3}} \implies y_3 = 1.71 \times 10^{-2}\text{ m}

    Correct

    y3=3×(532×10−9 m)×1.65 m0.180×10−3 m=1.46×10−2 my_3 = \frac{3 \times (532 \times 10^{-9}\text{ m}) \times 1.65\text{ m}}{0.180 \times 10^{-3}\text{ m}} = 1.46 \times 10^{-2}\text{ m}

    Your numerical computation was carried out correctly according to your initial expression, but it inherited the extra half-integer factor from Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted nanometers and millimeters into standard SI meters.

You identified the correct screen distance LL, slit spacing dd, and wavelength λ\lambda.

You executed the arithmetic and rounding with good precision.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Interference condition confusion

You introduced a half-integer offset (m+12)\left(m + \frac{1}{2}\right) into the fringe position formula.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing constructive interference (bright maxima, where path difference Δr=mλ\Delta r = m\lambda) with destructive interference (dark minima, where path difference Δr=(m+12)λ\Delta r = \left(m + \frac{1}{2}\right)\lambda).

REASONING PATH
Your ACEpath teacher’s suggested approach
Path difference for bright vs. dark fringes
  • Bright fringes (maxima) require Δr=mλ\Delta r = m\lambda (m=0,1,2,…m = 0, 1, 2, \dots). Dark fringes (minima) require Δr=(m+12)λ\Delta r = \left(m + \frac{1}{2}\right)\lambda.

  • Always verify whether the question asks for a bright fringe (maximum) or a dark fringe (minimum) before writing down the fringe formula.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the constructive interference condition for bright fringes: ym=mλLdy_m = \frac{m\lambda L}{d}.

  2. Substitute m=3m = 3, λ=532×10−9 m\lambda = 532 \times 10^{-9}\text{ m}, L=1.65 mL = 1.65\text{ m}, and d=1.80×10−4 md = 1.80 \times 10^{-4}\text{ m} into the formula: y3=3×(532×10−9 m)×1.65 m1.80×10−4 my_3 = \frac{3 \times (532 \times 10^{-9}\text{ m}) \times 1.65\text{ m}}{1.80 \times 10^{-4}\text{ m}}.

  3. Evaluate the numerator and denominator: y3=2.6334×10−6 m21.80×10−4 m≈1.463×10−2 my_3 = \frac{2.6334 \times 10^{-6}\text{ m}^2}{1.80 \times 10^{-4}\text{ m}} \approx 1.463 \times 10^{-2}\text{ m}.

Final answer

1.46×10−2 m1.46 \times 10^{-2}\text{ m} (or 1.46 cm1.46\text{ cm})

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the physical reason why bright fringes require full integer wavelengths Δr=mλ\Delta r = m\lambda (waves arrive in phase).

  • Practice distinguishing questions requesting fringe maxima versus fringe minima.

Lock it in

Similar question

01

Light of wavelength λ=633 nm\lambda = 633\text{ nm} passes through two slits separated by d=0.200 mmd = 0.200\text{ mm}. A screen is placed at L=2.00 mL = 2.00\text{ m}. Calculate the linear distance y2y_2 from the central maximum to the second-order (m=2m = 2) bright fringe in centimeters.

Answer

1.27 cm1.27\text{ cm}. Key steps: Convert d=0.200×10−3 md = 0.200 \times 10^{-3}\text{ m} and λ=633×10−9 m\lambda = 633 \times 10^{-9}\text{ m}. Using y2=2λLd=2(633×10−9 m)(2.00 m)2.00×10−4 m=1.266×10−2 m=1.27 cmy_2 = \frac{2\lambda L}{d} = \frac{2(633 \times 10^{-9}\text{ m})(2.00\text{ m})}{2.00 \times 10^{-4}\text{ m}} = 1.266 \times 10^{-2}\text{ m} = 1.27\text{ cm}.

02

In a double-slit experiment with slit separation d=120 μmd = 120\,\mu\text{m} and screen distance L=1.50 mL = 1.50\text{ m}, the distance between adjacent bright fringes is measured to be Δy=7.50 mm\Delta y = 7.50\text{ mm}. Find the wavelength λ\lambda of the light source in nanometers.

Answer

600 nm600\text{ nm}. Key steps: Fringe spacing is Δy=λLd\Delta y = \frac{\lambda L}{d}, so λ=dΔyL\lambda = \frac{d \Delta y}{L}. Convert d=120×10−6 md = 120 \times 10^{-6}\text{ m} and Δy=7.50×10−3 m\Delta y = 7.50 \times 10^{-3}\text{ m}. Then λ=(1.20×10−4 m)(7.50×10−3 m)1.50 m=6.00×10−7 m=600 nm\lambda = \frac{(1.20 \times 10^{-4}\text{ m})(7.50 \times 10^{-3}\text{ m})}{1.50\text{ m}} = 6.00 \times 10^{-7}\text{ m} = 600\text{ nm}.

03

A double-slit apparatus has slit separation d=0.150 mmd = 0.150\text{ mm} and screen distance L=1.80 mL = 1.80\text{ m}. When illuminated by light containing two wavelengths, λ1=450 nm\lambda_1 = 450\text{ nm} and λ2=600 nm\lambda_2 = 600\text{ nm}, find the physical separation on the screen between the third-order (m=3m = 3) bright fringes of the two wavelengths.

Answer

5.40 mm5.40\text{ mm} (or 5.40×10−3 m5.40 \times 10^{-3}\text{ m}). Key steps: The separation is Δy3=y3(λ2)−y3(λ1)=3Ld(λ2−λ1)\Delta y_3 = y_3(\lambda_2) - y_3(\lambda_1) = \frac{3L}{d}(\lambda_2 - \lambda_1). Convert d=1.50×10−4 md = 1.50 \times 10^{-4}\text{ m} and Δλ=150×10−9 m\Delta \lambda = 150 \times 10^{-9}\text{ m}. Thus Δy3=3(1.80 m)(1.50×10−7 m)1.50×10−4 m=5.40×10−3 m=5.40 mm\Delta y_3 = \frac{3(1.80\text{ m})(1.50 \times 10^{-7}\text{ m})}{1.50 \times 10^{-4}\text{ m}} = 5.40 \times 10^{-3}\text{ m} = 5.40\text{ mm}.

Loading workspace…