Resources

A municipal water purification reservoir contains V0=1.00×105 LV_0 = 1.00\times 10^5\text{ L} of clean water. An inlet pipe introduces saline runoff containing a salt concentration of cin=8.00 g/Lc_{\text{in}} = 8.00\text{ g/L} at a volumetric flow rate of rin=40.0 L/minr_{\text{in}} = 40.0\text{ L/min}. A well-mixed outlet pipe drains solution at an identical rate of rout=40.0 L/minr_{\text{out}} = 40.0\text{ L/min}, keeping volume constant. Many students mistakenly assume that the rate of change of salt mass dSdt\frac{dS}{dt} is constant because fluid flow rates are constant. Formulate the differential variable constraint for the instantaneous salt mass S(t)S(t) in grams, solve for S(t)S(t) subject to S(0)=0S(0) = 0, explain why the rate of salt accumulation strictly decreases over time, and compute the time tt (in hours) required for the salt concentration to reach 50.0%50.0\% of its asymptotic limit.

Answer and steps

Final answer

Differential constraint: dSdt=320−S2500\frac{dS}{dt} = 320 - \frac{S}{2500}; Solution: S(t)=8.00×105(1−e−t/2500) gS(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}; Accumulation slows because the outflow loss rate routS(t)V0\frac{r_{\text{out}}S(t)}{V_0} increases proportionally as S(t)S(t) builds up; Time to 50.0%50.0\%: t=2500ln⁡(2) min≈1733 min≈28.9 ht = 2500\ln(2)\text{ min} \approx 1733\text{ min} \approx 28.9\text{ h}

Steps

01

Formulating the Differential Constraint

The rate of change of the total salt mass S(t)S(t) inside the reservoir is governed by the conservation principle:

dSdt=Ratein−Rateout\frac{dS}{dt} = \text{Rate}_{\text{in}} - \text{Rate}_{\text{out}}

  • Input Rate: Salt enters the tank at a constant rate: Ratein=rin⋅cin=(40.0 L/min)⋅(8.00 g/L)=320 g/min\text{Rate}_{\text{in}} = r_{\text{in}} \cdot c_{\text{in}} = (40.0\text{ L/min}) \cdot (8.00\text{ g/L}) = 320\text{ g/min}
  • Output Rate: Because the liquid is well-mixed and the volume is constant at V(t)=V0=1.00×105 LV(t) = V_0 = 1.00\times 10^5\text{ L}, the concentration leaving through the outlet at any instant tt is S(t)V0\frac{S(t)}{V_0}. Therefore: Rateout=rout⋅(S(t)V0)=40.0⋅S(t)1.00×105=S(t)2500 g/min\text{Rate}_{\text{out}} = r_{\text{out}} \cdot \left(\frac{S(t)}{V_0}\right) = 40.0 \cdot \frac{S(t)}{1.00\times 10^5} = \frac{S(t)}{2500}\text{ g/min}

Combining these gives the differential equation constraint: dSdt=320−S2500\frac{dS}{dt} = 320 - \frac{S}{2500}


02

Solving for the Instantaneous Salt Mass S(t)S(t)

Rewrite the differential equation in standard linear form: dSdt+12500S=320\frac{dS}{dt} + \frac{1}{2500}S = 320

Separate variables or use an integrating factor μ(t)=e∫12500 dt=et/2500\mu(t) = e^{\int \frac{1}{2500}\,dt} = e^{t/2500}: ddt(S⋅et/2500)=320et/2500\frac{d}{dt}\left(S \cdot e^{t/2500}\right) = 320 e^{t/2500}

Integrate both sides with respect to tt: S⋅et/2500=320⋅2500et/2500+C=8.00×105et/2500+CS \cdot e^{t/2500} = 320 \cdot 2500 e^{t/2500} + C = 8.00\times 10^5 e^{t/2500} + C

Multiply through by e−t/2500e^{-t/2500}: S(t)=8.00×105+Ce−t/2500S(t) = 8.00\times 10^5 + C e^{-t/2500}

Apply the initial condition S(0)=0S(0) = 0 (initially clean water): 0=8.00×105+C  ⟹  C=−8.00×1050 = 8.00\times 10^5 + C \implies C = -8.00\times 10^5

Thus, the salt mass at any time tt (in minutes) is: S(t)=8.00×105(1−e−t/2500) gS(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}


03

Why the Rate of Salt Accumulation Decreases

Common Pitfall: A common mistake is to assume dSdt\frac{dS}{dt} is constant simply because the fluid flow rates rinr_{\text{in}} and routr_{\text{out}} are constant. However, the mass flow rate leaving the tank depends directly on the concentration inside the tank, not just the volume flow rate.

At t=0t = 0, the outgoing water contains no salt, so the rate of salt loss is zero and dSdt\frac{dS}{dt} is at its maximum (320 g/min320\text{ g/min}). As time progresses:

  1. Salt builds up, so S(t)S(t) increases.
  2. The outflow loss rate Rateout=routS(t)V0\text{Rate}_{\text{out}} = \frac{r_{\text{out}}S(t)}{V_0} increases in direct proportion to S(t)S(t).
  3. Because Ratein\text{Rate}_{\text{in}} is fixed at 320 g/min320\text{ g/min}, the net rate dSdt=320−S(t)2500\frac{dS}{dt} = 320 - \frac{S(t)}{2500} strictly decreases over time toward zero as the reservoir approaches its steady-state saturation limit.

04

Time Required to Reach 50.0%50.0\% of the Asymptotic Limit

As t→∞t \to \infty, the asymptotic limit is S∞=8.00×105 gS_{\infty} = 8.00\times 10^5\text{ g}.

We set S(t)=0.500⋅S∞S(t) = 0.500 \cdot S_{\infty}: 8.00×105(1−e−t/2500)=0.500⋅(8.00×105)8.00\times 10^5\left(1 - e^{-t/2500}\right) = 0.500 \cdot (8.00\times 10^5)

1−e−t/2500=0.500  ⟹  e−t/2500=0.5001 - e^{-t/2500} = 0.500 \implies e^{-t/2500} = 0.500

Take the natural logarithm of both sides: −t2500=ln⁡(0.500)=−ln⁡(2)-\frac{t}{2500} = \ln(0.500) = -\ln(2)

t=2500ln⁡(2) min≈2500⋅0.69315 min≈1733 mint = 2500\ln(2)\text{ min} \approx 2500 \cdot 0.69315\text{ min} \approx 1733\text{ min}

Convert the time to hours: t=1733 min60 min/h≈28.9 ht = \frac{1733\text{ min}}{60\text{ min/h}} \approx 28.9\text{ h}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert the final time from minutes to hours, leaving the answer as 1733.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    rate in=40.0×8.00=320 g/min  ⟹  rate out=40.0×(S100000)=S2500 g/min  ⟹  dSdt=320−S2500\text{rate in} = 40.0 \times 8.00 = 320\text{ g/min} \implies \text{rate out} = 40.0 \times \left(\frac{S}{100000}\right) = \frac{S}{2500}\text{ g/min} \implies \frac{dS}{dt} = 320 - \frac{S}{2500}

  2. Step 2

    dS320−S/2500=dt  ⟹  −2500ln⁡∣320−S2500∣=t+C  ⟹  S(0)=0 gives C=−2500ln⁡(320)  ⟹  ln⁡(1−S800000)=−t2500  ⟹  S(t)=800000(1−e−t/2500) g\frac{dS}{320 - S/2500} = dt \implies -2500\ln\left|320 - \frac{S}{2500}\right| = t + C \implies S(0) = 0\text{ gives } C = -2500\ln(320) \implies \ln\left(1 - \frac{S}{800000}\right) = -\frac{t}{2500} \implies S(t) = 800000\left(1 - e^{-t/2500}\right)\text{ g}

  3. Step 3

    As salt accumulates, concentration S/VS/V increases, making the outflow rate increase. Since the inflow rate is constant, the net accumulation rate dSdt=rate in−rate out\frac{dS}{dt} = \text{rate in} - \text{rate out} decreases.

  4. Step 4

    C(t)=8.00(1−e−t/2500)  ⟹  Asymptotic limit=8.00 g/L  ⟹  1−e−t/2500=0.500  ⟹  e−t/2500=0.500  ⟹  t=2500ln⁡(2)≈1733 hoursC(t) = 8.00\left(1 - e^{-t/2500}\right) \implies \text{Asymptotic limit} = 8.00\text{ g/L} \implies 1 - e^{-t/2500} = 0.500 \implies e^{-t/2500} = 0.500 \implies t = 2500\ln(2) \approx 1733\text{ hours}

    Correct

    t=2500ln⁡(2) min≈1733 min=173360 h≈28.9 ht = 2500\ln(2)\text{ min} \approx 1733\text{ min} = \frac{1733}{60}\text{ h} \approx 28.9\text{ h}

    Because flow rates were defined in liters per minute, your differential equation tracked time tt in minutes. The value 17331733 is in minutes, so you need to divide by 6060 to report the final answer in hours.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly set up the mass balance differential equation using volumetric flow rates and concentrations.

You solved the first-order differential equation accurately using separation of variables and properly evaluated the constant of integration.

You provided a solid physical justification for why the accumulation rate strictly decreases.

You correctly identified the half-life equation e−t/2500=0.500e^{-t/2500} = 0.500 and solved for tt algebraically.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing unit conversion from minutes to hours

You solved for the numerical time value t=2500ln⁡(2)≈1733t = 2500\ln(2) \approx 1733, but labeled it directly as hours instead of minutes.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You lost track of the base time unit established by the rate parameters (r=40.0 L/minr = 40.0\text{ L/min}), assuming the algebraic output was already in the requested unit of hours.

REASONING PATH
Your ACEpath teacher’s suggested approach
Trace Parameter Units to the Independent Variable
  • In an ODE dydt=f(y)\frac{dy}{dt} = f(y), the units of the independent variable tt are fixed by the time unit used in the rate constants (here, min−1\text{min}^{-1}).

  • Check the units of rinr_{\text{in}} and routr_{\text{out}} before solving to explicitly note what unit of time tt represents.

Match Solution to Target Units
  • When a problem explicitly requests an answer in a specific unit (such as hours), convert from the model's intrinsic unit using dimensional analysis.

  • Perform the conversion hours=minutes60\text{hours} = \frac{\text{minutes}}{60} as a final explicit step.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recognize that tt is expressed in minutes because the given flow rates are in L/min\text{L/min}.

  2. Convert minutes to hours: t=2500ln⁡(2) min60 min/h=1253ln⁡(2) ht = \frac{2500\ln(2)\text{ min}}{60\text{ min/h}} = \frac{125}{3}\ln(2)\text{ h}.

  3. Compute the numerical value: t≈1732.8760≈28.9 ht \approx \frac{1732.87}{60} \approx 28.9\text{ h}.

Final answer

t≈28.9 ht \approx 28.9\text{ h}

NEXT STEPS
Final Takeaways from Your Teacher
  • Annotate the units of your variables right next to your differential equation (e.g., write 'tt in minutes').

  • Highlight target units in the problem prompt during your first reading so you remember to check them at the end.

  • Practice multi-step modeling problems that require converting between different time or volume scales.

OverviewACEpath Teacher's Diagnosis

02 The student treats the accumulation rate as constant by ignoring the salt leaving through the outlet pipe.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    rate in=40.0×8.00=320 g/min\text{rate in} = 40.0 \times 8.00 = 320\text{ g/min}

  2. Step 2

    dSdt=320\frac{dS}{dt} = 320

    Correct

    dSdt=Ratein−Rateout=320−40.0⋅S(t)1.00×105=320−S2500\frac{dS}{dt} = \text{Rate}_{\text{in}} - \text{Rate}_{\text{out}} = 320 - \frac{40.0 \cdot S(t)}{1.00\times 10^5} = 320 - \frac{S}{2500}

    You omitted the rate of salt leaving through the outlet. Because fluid is constantly drained at 40.0 L/min40.0\text{ L/min}, salt leaves at a rate of rout⋅c(t)=40.0⋅S(t)1.00×105=S(t)2500 g/minr_{\text{out}} \cdot c(t) = 40.0 \cdot \frac{S(t)}{1.00\times 10^5} = \frac{S(t)}{2500}\text{ g/min}.

  3. Step 3

    dS=320 dt  ⟹  S(t)=320t+C  ⟹  S(0)=0 gives C=0  ⟹  S(t)=320t gdS = 320\,dt \implies S(t) = 320t + C \implies S(0) = 0 \text{ gives } C = 0 \implies S(t) = 320t\text{ g}

    Correct

    S(t)=8.00×105(1−e−t/2500) gS(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}

    Your integration was algebraically consistent with your equation, but the equation itself was missing the outflow term, leading to an incorrect linear mass function.

  4. Step 4

    The rate of salt accumulation does not decrease because dS/dt is constant.\text{The rate of salt accumulation does not decrease because } dS/dt \text{ is constant.}

    Correct

    As S(t) increases, the outflow loss rate S(t)2500 increases, so dSdt=320−S(t)2500 strictly decreases over time.\text{As } S(t) \text{ increases, the outflow loss rate } \frac{S(t)}{2500} \text{ increases, so } \frac{dS}{dt} = 320 - \frac{S(t)}{2500} \text{ strictly decreases over time.}

    This conclusion follows from your assumption that dSdt\frac{dS}{dt} is constant, but in physical reality, accumulation slows down because more salt is flushed out as the tank concentration increases.

  5. Step 5

    c(t)=S(t)100000=0.00320t  ⟹  0.00320t=4.00  ⟹  t=1250 min=20.8 hoursc(t) = \frac{S(t)}{100000} = 0.00320t \implies 0.00320t = 4.00 \implies t = 1250\text{ min} = 20.8\text{ hours}

    Correct

    t=2500ln⁡(2) min≈1733 min≈28.9 ht = 2500\ln(2)\text{ min} \approx 1733\text{ min} \approx 28.9\text{ h}

    Using a linear model gave 20.8 hours20.8\text{ hours}, whereas the true exponential saturation model requires approximately 28.9 hours28.9\text{ hours} to reach 50%50\% of the maximum concentration.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and computed the inflow mass rate of salt as 320 g/min320\text{ g/min}.

You properly applied the initial condition S(0)=0S(0) = 0 to find the constant of integration.

You correctly related the instantaneous concentration to the total volume as c(t)=S(t)V0c(t) = \frac{S(t)}{V_0}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of outflow rate in mixing model

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the rate of change of salt mass as equal only to the incoming rate, forgetting that well-mixed fluid draining from the outlet simultaneously carries dissolved salt out of the system.

REASONING PATH
Your ACEpath teacher’s suggested approach
Conservation of Mass in Open Systems
  • d(mass)dt=Ratein−Rateout\frac{d(\text{mass})}{dt} = \text{Rate}_{\text{in}} - \text{Rate}_{\text{out}}

  • Always write both the inflow and outflow rates before integrating, expressing Rateout\text{Rate}_{\text{out}} as rout⋅S(t)V(t)r_{\text{out}} \cdot \frac{S(t)}{V(t)}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the net rate equation: dSdt=Ratein−Rateout=320−S2500\frac{dS}{dt} = \text{Rate}_{\text{in}} - \text{Rate}_{\text{out}} = 320 - \frac{S}{2500}.

  2. Separate variables or use an integrating factor: dS320−S2500=dt  ⟹  −2500ln⁡∣320−S2500∣=t+C1\frac{dS}{320 - \frac{S}{2500}} = dt \implies -2500\ln\left|320 - \frac{S}{2500}\right| = t + C_1.

  3. Apply S(0)=0S(0) = 0 to solve for S(t)S(t): S(t)=8.00×105(1−e−t/2500) gS(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}.

  4. Set S(t)=0.500×(8.00×105)S(t) = 0.500 \times (8.00\times 10^5) to find the half-saturation time: 1−e−t/2500=0.500  ⟹  t=2500ln⁡(2) min≈1733 min≈28.9 h1 - e^{-t/2500} = 0.500 \implies t = 2500\ln(2)\text{ min} \approx 1733\text{ min} \approx 28.9\text{ h}.

Final answer

dSdt=320−S2500; S(t)=8.00×105(1−e−t/2500) g; t≈28.9 h\frac{dS}{dt} = 320 - \frac{S}{2500}\text{; } S(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g; } t \approx 28.9\text{ h}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review open mixing tank problems to practice writing Rateout\text{Rate}_{\text{out}} in terms of instantaneous concentration.

  • Work through first-order linear differential equations solved via integrating factor μ(t)=e∫P(t) dt\mu(t) = e^{\int P(t)\,dt}.

  • Practice checking asymptotic behavior (t→∞t \to \infty) to verify whether a solution reaches a realistic steady state.

OverviewACEpath Teacher's Diagnosis

03 The student miscalculates the volume ratio factor in the outflow rate as 40.0 / 100000 = 1 / 250 instead of 1 / 2500.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    rate in=40.0×8.00=320 g/min  ⟹  rate out=40.0×S100000=S250  ⟹  dSdt=320−S250\text{rate in} = 40.0 \times 8.00 = 320\text{ g/min} \implies \text{rate out} = 40.0 \times \frac{S}{100000} = \frac{S}{250} \implies \frac{dS}{dt} = 320 - \frac{S}{250}

    Correct

    Ratein=40.0×8.00=320 g/min  ⟹  Rateout=40.0S100000=S2500 g/min  ⟹  dSdt=320−S2500\text{Rate}_{\text{in}} = 40.0 \times 8.00 = 320\text{ g/min} \implies \text{Rate}_{\text{out}} = \frac{40.0 S}{100000} = \frac{S}{2500}\text{ g/min} \implies \frac{dS}{dt} = 320 - \frac{S}{2500}

    You set up the mass balance equation perfectly, but simplifying 40.0100 000\frac{40.0}{100\,000} gives 12500\frac{1}{2500}, not 1250\frac{1}{250}.

  2. Step 2

    dSdt+S250=320  ⟹  Integrating factor is et/250  ⟹  S(t)=80000(1−e−t/250) g\frac{dS}{dt} + \frac{S}{250} = 320 \implies \text{Integrating factor is } e^{t/250} \implies S(t) = 80000\left(1 - e^{-t/250}\right)\text{ g}

    Correct

    dSdt+S2500=320  ⟹  μ(t)=et/2500  ⟹  S(t)=8.00×105(1−e−t/2500) g\frac{dS}{dt} + \frac{S}{2500} = 320 \implies \mu(t) = e^{t/2500} \implies S(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}

    Your method for solving the first-order linear differential equation with an integrating factor and applying the initial condition S(0)=0S(0) = 0 was completely correct, though the numbers were affected by the missing zero from step 1.

  3. Step 3

    As salt accumulates, concentration increases so outflow rate increases. Because inflow rate is constant, dS/dt decreases over time.\text{As salt accumulates, concentration increases so outflow rate increases. Because inflow rate is constant, } dS/dt \text{ decreases over time.}

  4. Step 4

    1−e−t/250=0.500  ⟹  e−t/250=0.500  ⟹  t=250ln⁡(2)≈173.3 min  ⟹  t=173.360≈2.89 hours1 - e^{-t/250} = 0.500 \implies e^{-t/250} = 0.500 \implies t = 250\ln(2) \approx 173.3\text{ min} \implies t = \frac{173.3}{60} \approx 2.89\text{ hours}

    Correct

    1−e−t/2500=0.500  ⟹  t=2500ln⁡(2)≈1733 min  ⟹  t=173360≈28.9 h1 - e^{-t/2500} = 0.500 \implies t = 2500\ln(2) \approx 1733\text{ min} \implies t = \frac{1733}{60} \approx 28.9\text{ h}

    Your algebra to isolate tt and convert from minutes to hours was entirely sound, but carried forward the factor of 250250 instead of 25002500.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly formulated the conservation of mass law as the net difference between inflow rate and outflow rate.

You correctly identified and applied an integrating factor to solve the linear differential equation.

You clearly articulated why the salt accumulation rate decreases over time.

You set up and solved the half-saturation equation and accurately converted minutes to hours.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Arithmetic simplification error

You dropped a zero when reducing 40.0100 000\frac{40.0}{100\,000}, writing 1250\frac{1}{250} instead of 12500\frac{1}{2500}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

A quick mental division slip occurred when canceling zeros in powers of ten: dividing 100 000100\,000 by 4040 yields 25002500, not 250250.

REASONING PATH
Your ACEpath teacher’s suggested approach
Fraction Reduction with Large Denominators
  • a×101b×10k=ab×101−k\frac{a \times 10^1}{b \times 10^k} = \frac{a}{b} \times 10^{1-k}

  • Always cancel one factor of 1010 first before reducing: 40100 000=410 000=12500\frac{40}{100\,000} = \frac{4}{10\,000} = \frac{1}{2500}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recalculate the outflow rate coefficient: routV0=40.01.00×105=12500 min−1\frac{r_{\text{out}}}{V_0} = \frac{40.0}{1.00\times 10^5} = \frac{1}{2500}\text{ min}^{-1}.

  2. Write the differential equation: dSdt=320−S2500\frac{dS}{dt} = 320 - \frac{S}{2500}.

  3. Solve with the integrating factor et/2500e^{t/2500}: S(t)=320×2500(1−e−t/2500)=8.00×105(1−e−t/2500) gS(t) = 320 \times 2500\left(1 - e^{-t/2500}\right) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}.

  4. Solve for the half-saturation time: e−t/2500=0.500  ⟹  t=2500ln⁡(2)≈1733 mine^{-t/2500} = 0.500 \implies t = 2500\ln(2) \approx 1733\text{ min}.

  5. Convert to hours: t=173360≈28.9 ht = \frac{1733}{60} \approx 28.9\text{ h}.

Final answer

Differential constraint: dSdt=320−S2500\frac{dS}{dt} = 320 - \frac{S}{2500}; Solution: S(t)=8.00×105(1−e−t/2500) gS(t) = 8.00\times 10^5\left(1 - e^{-t/2500}\right)\text{ g}; Time to 50.0%50.0\%: t≈28.9 ht \approx 28.9\text{ h}

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check zero cancellations explicitly by writing powers of ten in scientific notation.

  • Verify the asymptotic limit dimensionally and numerically: S∞=cin×V0=8.00×100 000=800 000 gS_{\infty} = c_{\text{in}} \times V_0 = 8.00 \times 100\,000 = 800\,000\text{ g}, which immediately catches a coefficient of 80 00080\,000.

Lock it in

Similar question

01

A tank containing 500 L500\text{ L} of water receives brine at 5.0 L/s5.0\text{ L/s} and drains well-mixed liquid at the same rate. The model yields S(t)=Smax⁡(1−e−t/100)S(t) = S_{\max}(1 - e^{-t/100}). Compute the time tt in minutes for S(t)S(t) to reach 50%50\% of Smax⁡S_{\max}.

Answer

1−e−t/100=0.50  ⟹  t=100ln⁡(2) seconds1 - e^{-t/100} = 0.50 \implies t = 100\ln(2)\text{ seconds}. Convert to minutes: t=100ln⁡(2)60=53ln⁡(2) min≈1.16 mint = \frac{100\ln(2)}{60} = \frac{5}{3}\ln(2)\text{ min} \approx 1.16\text{ min}.

02

A reservoir has volume V=10,000 m3V = 10{,}000\text{ m}^3. An inlet introduces pollutant at rin=200 m3/dayr_{\text{in}} = 200\text{ m}^3/\text{day} with concentration cin=15 g/m3c_{\text{in}} = 15\text{ g/m}^3, and an outlet drains at the same rate. If the reservoir initially contains pure water, find the time tt (in weeks) required for the pollutant mass to reach 75%75\% of its steady-state value.

Answer

The differential equation is dPdt=3000−P50\frac{dP}{dt} = 3000 - \frac{P}{50}, giving P(t)=150,000(1−e−t/50)P(t) = 150{,}000(1 - e^{-t/50}) with tt in days. Setting 1−e−t/50=0.751 - e^{-t/50} = 0.75 gives e−t/50=0.25  ⟹  t=50ln⁡(4)≈69.31 dayse^{-t/50} = 0.25 \implies t = 50\ln(4) \approx 69.31\text{ days}. Convert to weeks: t=69.317≈9.90 weekst = \frac{69.31}{7} \approx 9.90\text{ weeks}.

03

A chemical reactor of volume V0=2000 LV_0 = 2000\text{ L} has an inlet rate of rin=10.0 L/minr_{\text{in}} = 10.0\text{ L/min} with tracer concentration 2.00 g/L2.00\text{ g/L}, and an outlet rate of rout=10.0 L/minr_{\text{out}} = 10.0\text{ L/min}. Simultaneously, the tracer degrades inside the reactor at a rate kM(t)k M(t), where k=0.0050 min−1k = 0.0050\text{ min}^{-1}. Formulate dMdt\frac{dM}{dt} and find the time tt (in hours) to reach 90.0%90.0\% of the asymptotic tracer mass.

Answer

Mass balance: dMdt=(10)(2)−102000M−0.005M=20−0.010M\frac{dM}{dt} = (10)(2) - \frac{10}{2000}M - 0.005M = 20 - 0.010M. The solution is M(t)=2000(1−e−0.010t)M(t) = 2000(1 - e^{-0.010t}) with tt in minutes. For 90%90\% of limit: 1−e−0.010t=0.90  ⟹  e−0.010t=0.10  ⟹  t=ln⁡(10)0.010=100ln⁡(10)≈230.26 min1 - e^{-0.010t} = 0.90 \implies e^{-0.010t} = 0.10 \implies t = \frac{\ln(10)}{0.010} = 100\ln(10) \approx 230.26\text{ min}. Converting to hours: t=230.2660≈3.84 ht = \frac{230.26}{60} \approx 3.84\text{ h}.

Loading workspace…