Resources
A municipal water purification reservoir contains of clean water. An inlet pipe introduces saline runoff containing a salt concentration of at a volumetric flow rate of . A well-mixed outlet pipe drains solution at an identical rate of , keeping volume constant. Many students mistakenly assume that the rate of change of salt mass is constant because fluid flow rates are constant. Formulate the differential variable constraint for the instantaneous salt mass in grams, solve for subject to , explain why the rate of salt accumulation strictly decreases over time, and compute the time (in hours) required for the salt concentration to reach of its asymptotic limit.
Answer and steps
Final answer
Differential constraint: ; Solution: ; Accumulation slows because the outflow loss rate increases proportionally as builds up; Time to :
Steps
Formulating the Differential Constraint
The rate of change of the total salt mass inside the reservoir is governed by the conservation principle:
- Input Rate: Salt enters the tank at a constant rate:
- Output Rate: Because the liquid is well-mixed and the volume is constant at , the concentration leaving through the outlet at any instant is . Therefore:
Combining these gives the differential equation constraint:
Solving for the Instantaneous Salt Mass
Rewrite the differential equation in standard linear form:
Separate variables or use an integrating factor :
Integrate both sides with respect to :
Multiply through by :
Apply the initial condition (initially clean water):
Thus, the salt mass at any time (in minutes) is:
Why the Rate of Salt Accumulation Decreases
Common Pitfall: A common mistake is to assume is constant simply because the fluid flow rates and are constant. However, the mass flow rate leaving the tank depends directly on the concentration inside the tank, not just the volume flow rate.
At , the outgoing water contains no salt, so the rate of salt loss is zero and is at its maximum (). As time progresses:
- Salt builds up, so increases.
- The outflow loss rate increases in direct proportion to .
- Because is fixed at , the net rate strictly decreases over time toward zero as the reservoir approaches its steady-state saturation limit.
Time Required to Reach of the Asymptotic Limit
As , the asymptotic limit is .
We set :
Take the natural logarithm of both sides:
Convert the time to hours:
Typical errors
01 The student forgets to convert the final time from minutes to hours, leaving the answer as 1733.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
As salt accumulates, concentration increases, making the outflow rate increase. Since the inflow rate is constant, the net accumulation rate decreases.
- Step 4Correct
Because flow rates were defined in liters per minute, your differential equation tracked time in minutes. The value is in minutes, so you need to divide by to report the final answer in hours.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly set up the mass balance differential equation using volumetric flow rates and concentrations.
You solved the first-order differential equation accurately using separation of variables and properly evaluated the constant of integration.
You provided a solid physical justification for why the accumulation rate strictly decreases.
You correctly identified the half-life equation and solved for algebraically.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou solved for the numerical time value , but labeled it directly as hours instead of minutes.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou lost track of the base time unit established by the rate parameters (), assuming the algebraic output was already in the requested unit of hours.
REASONING PATH
Your ACEpath teacher’s suggested approach- Trace Parameter Units to the Independent Variable
In an ODE , the units of the independent variable are fixed by the time unit used in the rate constants (here, ).
Check the units of and before solving to explicitly note what unit of time represents.
- Match Solution to Target Units
When a problem explicitly requests an answer in a specific unit (such as hours), convert from the model's intrinsic unit using dimensional analysis.
Perform the conversion as a final explicit step.
CORRECTED PATH
ACEpath Teacher's DemonstrationRecognize that is expressed in minutes because the given flow rates are in .
Convert minutes to hours: .
Compute the numerical value: .
02 The student treats the accumulation rate as constant by ignoring the salt leaving through the outlet pipe.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You omitted the rate of salt leaving through the outlet. Because fluid is constantly drained at , salt leaves at a rate of .
- Step 3Correct
Your integration was algebraically consistent with your equation, but the equation itself was missing the outflow term, leading to an incorrect linear mass function.
- Step 4Correct
This conclusion follows from your assumption that is constant, but in physical reality, accumulation slows down because more salt is flushed out as the tank concentration increases.
- Step 5Correct
Using a linear model gave , whereas the true exponential saturation model requires approximately to reach of the maximum concentration.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified and computed the inflow mass rate of salt as .
You properly applied the initial condition to find the constant of integration.
You correctly related the instantaneous concentration to the total volume as .
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the rate of change of salt mass as equal only to the incoming rate, forgetting that well-mixed fluid draining from the outlet simultaneously carries dissolved salt out of the system.
REASONING PATH
Your ACEpath teacher’s suggested approach- Conservation of Mass in Open Systems
Always write both the inflow and outflow rates before integrating, expressing as .
CORRECTED PATH
ACEpath Teacher's DemonstrationWrite the net rate equation: .
Separate variables or use an integrating factor: .
Apply to solve for : .
Set to find the half-saturation time: .
03 The student miscalculates the volume ratio factor in the outflow rate as 40.0 / 100000 = 1 / 250 instead of 1 / 2500.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You set up the mass balance equation perfectly, but simplifying gives , not .
- Step 2Correct
Your method for solving the first-order linear differential equation with an integrating factor and applying the initial condition was completely correct, though the numbers were affected by the missing zero from step 1.
- Step 3
- Step 4Correct
Your algebra to isolate and convert from minutes to hours was entirely sound, but carried forward the factor of instead of .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly formulated the conservation of mass law as the net difference between inflow rate and outflow rate.
You correctly identified and applied an integrating factor to solve the linear differential equation.
You clearly articulated why the salt accumulation rate decreases over time.
You set up and solved the half-saturation equation and accurately converted minutes to hours.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou dropped a zero when reducing , writing instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisA quick mental division slip occurred when canceling zeros in powers of ten: dividing by yields , not .
REASONING PATH
Your ACEpath teacher’s suggested approach- Fraction Reduction with Large Denominators
Always cancel one factor of first before reducing: .
CORRECTED PATH
ACEpath Teacher's DemonstrationRecalculate the outflow rate coefficient: .
Write the differential equation: .
Solve with the integrating factor : .
Solve for the half-saturation time: .
Convert to hours: .
Differential constraint: ; Solution: ; Time to :
Lock it in
How do the units of rate constants in an ODE determine the units of the independent time variable ?
The time unit of must match the time unit in the rates (e.g., flow rate in means is strictly in minutes).
Similar question
A tank containing of water receives brine at and drains well-mixed liquid at the same rate. The model yields . Compute the time in minutes for to reach of .
Answer
. Convert to minutes: .
A reservoir has volume . An inlet introduces pollutant at with concentration , and an outlet drains at the same rate. If the reservoir initially contains pure water, find the time (in weeks) required for the pollutant mass to reach of its steady-state value.
Answer
The differential equation is , giving with in days. Setting gives . Convert to weeks: .
A chemical reactor of volume has an inlet rate of with tracer concentration , and an outlet rate of . Simultaneously, the tracer degrades inside the reactor at a rate , where . Formulate and find the time (in hours) to reach of the asymptotic tracer mass.
Answer
Mass balance: . The solution is with in minutes. For of limit: . Converting to hours: .