Resources

A municipal water filtration plant pumps treated effluent through an intake chamber. The flow rate of water is monitored as R(t)=180+12cos⁡(πt12)R(t) = 180 + 12\cos\left(\frac{\pi t}{12}\right), where R(t)R(t) is measured in cubic meters per hour (m3/h\text{m}^3\text{/h}) and tt is time in hours over a 24-hour cycle (0≤t≤240 \le t \le 24). (a) Evaluate the total volume V=∫024R(t) dtV = \int_{0}^{24} R(t)\,dt in cubic meters, and convert this total into liters (L\text{L}) using 1 m3=1,000 L1\text{ m}^3 = 1{,}000\text{ L}. (b) If municipal health guidelines allocate a standard consumption quota of 300 L300\text{ L} per resident per day, explain the real-world capacity of this 24-hour discharge volume in terms of the number of citizens it can fully sustain.

Answer and steps

Final answer

(a) V=4,320 m3=4.32×106 LV = 4{,}320\text{ m}^3 = 4.32 \times 10^6\text{ L}; (b) Dividing the total filtered output of 4,320,000 L4{,}320{,}000\text{ L} by the daily individual quota of 300 L/resident300\text{ L/resident} shows that this single facility's daily output provides the complete municipal clean water supply for 14,40014{,}400 residents.

Steps

Part (a): Calculating Total Volume and Unit Conversion

To find the total volume VV of treated water pumped over the 24-hour cycle, integrate the flow rate function R(t)R(t) from t=0t = 0 to t=24t = 24:

V=∫024R(t) dt=∫024[180+12cos⁡(πt12)]dtV = \int_{0}^{24} R(t)\,dt = \int_{0}^{24} \left[ 180 + 12\cos\left(\frac{\pi t}{12}\right) \right] dt

Apply the linearity of integration:

V=∫024180 dt+12∫024cos⁡(πt12)dtV = \int_{0}^{24} 180\,dt + 12 \int_{0}^{24} \cos\left(\frac{\pi t}{12}\right) dt

  1. Evaluate the constant term: ∫024180 dt=[180t]024=180⋅24−180⋅0=4,320 m3\int_{0}^{24} 180\,dt = \left[ 180t \right]_{0}^{24} = 180 \cdot 24 - 180 \cdot 0 = 4{,}320\text{ m}^3
  2. Evaluate the periodic cosine term: The antiderivative of cos⁡(kt)\cos(kt) is 1ksin⁡(kt)\frac{1}{k}\sin(kt), where k=π12k = \frac{\pi}{12}: ∫024cos⁡(πt12)dt=[12πsin⁡(πt12)]024=12πsin⁡(2π)−12πsin⁡(0)=0−0=0\int_{0}^{24} \cos\left(\frac{\pi t}{12}\right) dt = \left[ \frac{12}{\pi}\sin\left(\frac{\pi t}{12}\right) \right]_{0}^{24} = \frac{12}{\pi}\sin(2\pi) - \frac{12}{\pi}\sin(0) = 0 - 0 = 0

    Insight: The integration interval t∈[0,24]t \in [0, 24] covers exactly one full period T=2ππ/12=24 hoursT = \frac{2\pi}{\pi/12} = 24\text{ hours} of the cosine wave. The positive and negative fluctuations around the mean rate of 180 m3/h180\text{ m}^3\text{/h} cancel each other out over the complete day.

Adding the two components yields: V=4,320+0=4,320 m3V = 4{,}320 + 0 = 4{,}320\text{ m}^3

Now convert the volume into liters (L\text{L}) using 1 m3=1,000 L1\text{ m}^3 = 1{,}000\text{ L}: V=4,320 m3×1,000 L/m3=4,320,000 L=4.32×106 LV = 4{,}320\text{ m}^3 \times 1{,}000\text{ L/m}^3 = 4{,}320{,}000\text{ L} = 4.32 \times 10^6\text{ L}


Part (b): Interpreting the Result in a Real-World Context

In mathematical modeling, the final numerical output must be mapped back to the practical scenario:

  • Total daily supply available: 4,320,000 L4{,}320{,}000\text{ L}
  • Per capita consumption quota: 300 L/resident/day300\text{ L/resident/day}

To determine how many residents this daily volume can sustain, divide the daily volume by the per-person daily quota:

Capacity=4,320,000 L300 L/resident=14,400 residents\text{Capacity} = \frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}

Conclusion: The daily output of this single filtration plant supplies sufficient water to fully meet the municipal needs of 14,40014{,}400 residents under the specified health guidelines.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to multiply by the reciprocal of the inner coefficient π/12 when integrating cos(πt/12), but because sin(2π) and sin(0) both equal 0, the integral calculation for volume is unchanged, so instead the student integrates cos(kx) incorrectly as -sin(kx) and drops π/12 altogether, or differentiates the inner function yielding an incorrect coefficient, or more critically, the student fails to convert cubic meters to liters before dividing by the 300 L quota, arriving at an unphysical decimal number of residents.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    V=∫024(180+12cos⁡(πt12))dt  ⟹  V=[180t+144πsin⁡(πt12)]024  ⟹  V=180(24)+144πsin⁡(2π)−0=4320 m3V = \int_{0}^{24} \left(180 + 12\cos\left(\frac{\pi t}{12}\right)\right) dt \implies V = \left[180t + \frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right)\right]_{0}^{24} \implies V = 180(24) + \frac{144}{\pi}\sin(2\pi) - 0 = 4320\text{ m}^3

  2. Step 2

    4320×1000=4320000 L4320 \times 1000 = 4320000\text{ L}

  3. Step 3

    Capacity=4320300=14.4 citizens  ⟹  The volume can only sustain 14 citizens fully.\text{Capacity} = \frac{4320}{300} = 14.4\text{ citizens} \implies \text{The volume can only sustain 14 citizens fully.}

    Correct

    Capacity=4,320,000 L300 L/resident=14,400 residents\text{Capacity} = \frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}

    You divided the volume in cubic meters (4,320 m34{,}320\text{ m}^3) by the per-person quota in liters (300 L300\text{ L}), rather than using the converted volume in liters (4,320,000 L4{,}320{,}000\text{ L}). Because the units in the numerator and denominator must match, the division should be 4,320,000 L300 L/resident=14,400 residents\frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly integrated the trigonometric rate function using the chain rule antiderivative.

You evaluated the definite integral over the full 24-hour cycle to find 4,320 m34{,}320\text{ m}^3.

You successfully converted the volume into liters as 4,320,000 L4{,}320{,}000\text{ L}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit mismatch in rate/ratio quotient

You used the unconverted volume of 4,3204{,}320 rather than your converted volume of 4,320,0004{,}320{,}000 when calculating the population capacity.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Forgetting to carry forward the converted unit into subsequent modeling calculations, resulting in a quotient between quantities with mismatched units (cubic meters divided by liters).

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional Consistency Check
  • When forming a ratio AB\frac{A}{B} to count units of BB in AA, both AA and BB must share the same base physical dimension and unit.

  • Write explicit units alongside numbers in division steps: 4,320,000 L300 L/person=14,400 persons\frac{4{,}320{,}000\text{ L}}{300\text{ L/person}} = 14{,}400\text{ persons}.

Real-World Sense-Making
  • A municipal filtration plant operating at over 180 m3/h180\text{ m}^3\text{/h} pumps millions of liters per day.

  • Pause when a major municipal facility produces an answer of only 1414 people; such an unusually low number signals a missing scale factor of 1,0001{,}000.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Substitute the total volume in liters (4,320,000 L4{,}320{,}000\text{ L}) into the capacity equation.

  2. Divide by the individual daily quota: Capacity=4,320,000 L300 L/resident\text{Capacity} = \frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}}.

  3. Simplify the fraction: 4,320,000300=14,400\frac{4{,}320{,}000}{300} = 14{,}400.

Final answer

The daily discharge volume can fully sustain 14,40014{,}400 residents.

NEXT STEPS
Final Takeaways from Your Teacher
  • Include unit symbols inside every calculation step rather than appending them only to the final number.

  • Perform a sanity check on real-world modeling answers to verify that the scale of the result matches the scale of the facility.

OverviewACEpath Teacher's Diagnosis

02 The student misapplies the chain rule in reverse by multiplying by the internal derivative π/12 rather than dividing by it when integrating cos(πt/12), yielding 12(π/12)sin(πt/12) = π sin(πt/12), though evaluating at 0 and 24 still gives 0, but the student mistakenly computes sin(2π) = 1, leading to an incorrect total volume.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    V=∫024(180+12cos⁡(πt12))dt  ⟹  V=[180t+(144πsin⁡(πt12))]024V = \int_{0}^{24} \left(180 + 12\cos\left(\frac{\pi t}{12}\right)\right) dt \implies V = \left[ 180t + \left(\frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right)\right) \right]_{0}^{24}

  2. Step 2

    sin⁡(2π)=1 and sin⁡(0)=0  ⟹  V=4320+144π m3≈4365.8 m3\sin(2\pi) = 1 \text{ and } \sin(0) = 0 \implies V = 4320 + \frac{144}{\pi}\text{ m}^3 \approx 4365.8\text{ m}^3

    Correct

    sin⁡(2π)=0 and sin⁡(0)=0  ⟹  V=180(24)+144π(0−0)=4,320 m3\sin(2\pi) = 0 \text{ and } \sin(0) = 0 \implies V = 180(24) + \frac{144}{\pi}(0 - 0) = 4{,}320\text{ m}^3

    On the unit circle, the terminal point at 2π2\pi radians is (1,0)(1, 0), which means cos⁡(2π)=1\cos(2\pi) = 1 and sin⁡(2π)=0\sin(2\pi) = 0. Because sin⁡(2π)=0\sin(2\pi) = 0, the trigonometric term evaluates to 00, leaving V=4,320 m3V = 4{,}320\text{ m}^3.

  3. Step 3

    4365.8×10001≈4,365,800 L4365.8 \times \frac{1000}{1} \approx 4{,}365{,}800\text{ L}

    Correct

    4,320 m3×1,000 L/m3=4,320,000 L4{,}320\text{ m}^3 \times 1{,}000\text{ L/m}^3 = 4{,}320{,}000\text{ L}

    Your conversion method of multiplying by 1,000 L/m31{,}000\text{ L/m}^3 was correct, but your result was affected by the volume error from Step 2.

  4. Step 4

    Capacity=4,365,800300≈14,552.7 citizens  ⟹  It can fully sustain 14,552 citizens.\text{Capacity} = \frac{4{,}365{,}800}{300} \approx 14{,}552.7\text{ citizens} \implies \text{It can fully sustain } 14{,}552\text{ citizens.}

    Correct

    Capacity=4,320,000 L300 L/resident=14,400 residents\text{Capacity} = \frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}

    Your modeling approach of dividing the total daily water output by the daily consumption quota was completely sound, but the numerical answer inherits the earlier trigonometric evaluation error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly integrated the trigonometric function using the reverse chain rule.

You set up the unit conversion from cubic meters to liters properly.

You correctly interpreted the quota problem by dividing the total daily capacity by individual usage.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Trigonometric evaluation at boundary

You evaluated sin⁡(2π)=1\sin(2\pi) = 1, confusing the sine and cosine coordinates at an angle of 2π2\pi.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the xx- and yy-coordinates on the unit circle for quadrantal angles (0,π2,π,3π2,2π0, \frac{\pi}{2}, \pi, \frac{3\pi}{2}, 2\pi). For any full turn around the unit circle, the point is (x,y)=(1,0)(x, y) = (1, 0), so cos⁡(2π)=1\cos(2\pi) = 1 and sin⁡(2π)=0\sin(2\pi) = 0.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Circle Coordinates
  • For any angle θ\theta, the point on the unit circle is (cos⁡θ,sin⁡θ)(\cos\theta, \sin\theta).

  • At θ=2π\theta = 2\pi, the terminal point lies on the positive xx-axis at (1,0)(1, 0), so cos⁡(2π)=1\cos(2\pi) = 1 and sin⁡(2π)=0\sin(2\pi) = 0.

Full-Period Net Integral of Sinusoids
  • The definite integral of sin⁡(kt)\sin(kt) or cos⁡(kt)\cos(kt) over any full period T=2πkT = \frac{2\pi}{k} is always 00.

  • Recognize that over a 24-hour cycle, the periodic fluctuations above and below the baseline flow exactly cancel each other out.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Evaluate the sine term at both integration limits: sin⁡(π⋅2412)−sin⁡(0)=sin⁡(2π)−sin⁡(0)=0−0=0\sin\left(\frac{\pi \cdot 24}{12}\right) - \sin(0) = \sin(2\pi) - \sin(0) = 0 - 0 = 0.

  2. Calculate the total volume: V=180(24)+144π(0)=4,320 m3V = 180(24) + \frac{144}{\pi}(0) = 4{,}320\text{ m}^3.

  3. Convert to liters: 4,320 m3×1,000 L/m3=4,320,000 L4{,}320\text{ m}^3 \times 1{,}000\text{ L/m}^3 = 4{,}320{,}000\text{ L}.

  4. Calculate resident capacity: 4,320,000 L300 L/resident=14,400 residents\frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}.

Final answer

(a) V=4,320 m3=4,320,000 LV = 4{,}320\text{ m}^3 = 4{,}320{,}000\text{ L}; (b) The plant can fully sustain 14,40014{,}400 residents.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review unit circle values for quadrantal angles, remembering that sin⁡\sin corresponds to the vertical yy-coordinate and cos⁡\cos corresponds to the horizontal xx-coordinate.

  • Use the periodic symmetry property of sine and cosine: integrating over an exact multiple of the period will always yield zero net area for the wave term.

OverviewACEpath Teacher's Diagnosis

03 The student confuses the anti-derivative of cosine with negative sine, writing -144/π sin(πt/12), and evaluates sin(2π) as 2π, adding an erroneous term to the integral result.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    V=∫024(180+12cos⁡(πt12))dt  ⟹  V=[180t−144πsin⁡(πt12)]024V = \int_{0}^{24} \left(180 + 12\cos\left(\frac{\pi t}{12}\right)\right)dt \implies V = \left[ 180t - \frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right) \right]_{0}^{24}

    Correct

    V=[180t+144πsin⁡(πt12)]024V = \left[ 180t + \frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right) \right]_{0}^{24}

    The antiderivative of cos⁡(kt)\cos(kt) is +1ksin⁡(kt)+\frac{1}{k}\sin(kt), not −1ksin⁡(kt)-\frac{1}{k}\sin(kt). You should have added 12π/12sin⁡(πt12)=144πsin⁡(πt12)\frac{12}{\pi/12}\sin\left(\frac{\pi t}{12}\right) = \frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right).

  2. Step 2

    V=4320−288=4032 m3V = 4320 - 288 = 4032\text{ m}^3

    Correct

    V=(180⋅24+0)−0=4,320 m3V = (180 \cdot 24 + 0) - 0 = 4{,}320\text{ m}^3

    When evaluating the upper limit, sin⁡(π⋅2412)=sin⁡(2π)=0\sin\left(\frac{\pi \cdot 24}{12}\right) = \sin(2\pi) = 0. You treated sin⁡(2π)\sin(2\pi) as 2π2\pi, leading to 144π(2π)=288\frac{144}{\pi}(2\pi) = 288 instead of 00.

  3. Step 3

    4032 m3×1000=4032000 L4032\text{ m}^3 \times 1000 = 4032000\text{ L}

    Correct

    4,320 m3×1,000=4,320,000 L=4.32×106 L4{,}320\text{ m}^3 \times 1{,}000 = 4{,}320{,}000\text{ L} = 4.32 \times 10^6\text{ L}

    Your unit conversion method of multiplying by 1,000 L/m31{,}000\text{ L/m}^3 is completely correct, but the calculation inherits the incorrect volume from the previous step.

  4. Step 4

    Capacity=4032000300=13440  ⟹  The discharge volume can fully sustain 13440 citizens.\text{Capacity} = \frac{4032000}{300} = 13440 \implies \text{The discharge volume can fully sustain } 13440\text{ citizens.}

    Correct

    Capacity=4,320,000300=14,400 residents\text{Capacity} = \frac{4{,}320{,}000}{300} = 14{,}400\text{ residents}

    Your modeling logic and final sentence interpret the quotient accurately, but the numerical answer is affected by your earlier integration mistakes.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly set up the definite integral of flow rate over the 24-hour interval.

You successfully integrated the constant rate term 180180 to obtain 4,3204{,}320.

You correctly applied the conversion factor 1 m3=1,000 L1\text{ m}^3 = 1{,}000\text{ L}.

You accurately interpreted the division of total daily volume by daily per-person quota into community capacity.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Trigonometric Integration and Evaluation

You substituted 2π2\pi instead of 00 for the value of sin⁡(2π)\sin(2\pi).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the differentiation rule ddx(cos⁡x)=−sin⁡x\frac{d}{dx}(\cos x) = -\sin x with the antiderivative rule ∫cos⁡x dx=sin⁡x+C\int \cos x\,dx = \sin x + C, and you conflated a radian angle measure (2π2\pi) with the trigonometric output sin⁡(2π)\sin(2\pi).

REASONING PATH
Your ACEpath teacher’s suggested approach
Antiderivative of Cosine
  • ∫cos⁡(kt) dt=1ksin⁡(kt)+C\int \cos(kt)\,dt = \frac{1}{k}\sin(kt) + C

  • Check your sign by differentiating your antiderivative: ddt[sin⁡(kt)]=kcos⁡(kt)\frac{d}{dt}[\sin(kt)] = k\cos(kt), confirming a positive sign.

Sine at Integer Multiples of $\pi$
  • sin⁡(nπ)=0\sin(n\pi) = 0 for every integer nn

  • Remember that 2π2\pi radians completes one full turn around the unit circle, returning to (1,0)(1, 0) where the yy-coordinate is 00.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. V=[180t+144πsin⁡(πt12)]024V = \left[ 180t + \frac{144}{\pi}\sin\left(\frac{\pi t}{12}\right) \right]_{0}^{24}

  2. V=(180(24)+144πsin⁡(2π))−(180(0)+144πsin⁡(0))=4,320+0−0=4,320 m3V = \left(180(24) + \frac{144}{\pi}\sin(2\pi)\right) - \left(180(0) + \frac{144}{\pi}\sin(0)\right) = 4{,}320 + 0 - 0 = 4{,}320\text{ m}^3

  3. V=4,320 m3×1,000 L/m3=4,320,000 LV = 4{,}320\text{ m}^3 \times 1{,}000\text{ L/m}^3 = 4{,}320{,}000\text{ L}

  4. Capacity=4,320,000 L300 L/resident=14,400 residents\text{Capacity} = \frac{4{,}320{,}000\text{ L}}{300\text{ L/resident}} = 14{,}400\text{ residents}

Final answer

(a) V=4,320 m3=4.32×106 LV = 4{,}320\text{ m}^3 = 4.32 \times 10^6\text{ L}; (b) The daily discharge volume can fully sustain 14,40014{,}400 residents.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the derivatives versus integrals of basic trigonometric functions, focusing on when a negative sign appears.

  • Practice evaluating common unit-circle angles such as 00, π2\frac{\pi}{2}, π\pi, and 2π2\pi.

  • Use periodicity to quickly recognize that the integral of a sinusoidal fluctuation over an exact full period is 00.

Lock it in

Similar question

01

An irrigation canal delivers water at a constant rate of 50 m3/h50\text{ m}^3\text{/h} for 12 hours12\text{ hours}. If an agricultural plot requires 400 L400\text{ L} of water per tree per day, how many trees can this discharge fully irrigate? (1 m3=1,000 L1\text{ m}^3 = 1{,}000\text{ L})

Answer

Total volume =50 m3/h×12 h=600 m3=600,000 L= 50\text{ m}^3\text{/h} \times 12\text{ h} = 600\text{ m}^3 = 600{,}000\text{ L}. Number of trees =600,000 L400 L/tree=1,500 trees= \frac{600{,}000\text{ L}}{400\text{ L/tree}} = 1{,}500\text{ trees}.

02

A chemical plant neutralizes acidic wastewater according to the flow rate F(t)=40+8sin⁡(πt6)F(t) = 40 + 8\sin\left(\frac{\pi t}{6}\right) in m3/h\text{m}^3\text{/h} over a 12-hour12\text{-hour} shift (0≤t≤120 \le t \le 12). Neutralization powder is added at a standard ratio of 25 g25\text{ g} per liter of wastewater. How many kilograms of powder are needed for the entire shift? (1 m3=1,000 L1\text{ m}^3 = 1{,}000\text{ L}; 1 kg=1,000 g1\text{ kg} = 1{,}000\text{ g})

Answer

Total volume =∫012(40+8sin⁡(πt6))dt=[40t−48πcos⁡(πt6)]012=480 m3=480,000 L= \int_0^{12} \left(40 + 8\sin\left(\frac{\pi t}{6}\right)\right)dt = [40t - \frac{48}{\pi}\cos(\frac{\pi t}{6})]_0^{12} = 480\text{ m}^3 = 480{,}000\text{ L}. Total powder in grams =480,000 L×25 g/L=12,000,000 g= 480{,}000\text{ L} \times 25\text{ g/L} = 12{,}000{,}000\text{ g}. Convert to kilograms: 12,000,000 g1,000 g/kg=12,000 kg\frac{12{,}000{,}000\text{ g}}{1{,}000\text{ g/kg}} = 12{,}000\text{ kg}.

03

A storm surge drainage pump operates with rate P(t)=120−30cos⁡(πt4)P(t) = 120 - 30\cos\left(\frac{\pi t}{4}\right) in m3/min\text{m}^3\text{/min} for 8 minutes8\text{ minutes} (0≤t≤80 \le t \le 8). The collected runoff is transferred into storage tanks with a capacity of 40,000 L40{,}000\text{ L} each. What is the minimum whole number of tanks required to hold all pumped runoff?

Answer

Total volume =∫08(120−30cos⁡(πt4))dt=[120t−120πsin⁡(πt4)]08=960 m3= \int_0^8 \left(120 - 30\cos\left(\frac{\pi t}{4}\right)\right)dt = [120t - \frac{120}{\pi}\sin(\frac{\pi t}{4})]_0^8 = 960\text{ m}^3. Convert to liters: 960×1,000=960,000 L960 \times 1{,}000 = 960{,}000\text{ L}. Number of tanks =960,000 L40,000 L/tank=24 tanks= \frac{960{,}000\text{ L}}{40{,}000\text{ L/tank}} = 24\text{ tanks}.

Loading workspace…