Resources

The concentration C(t)C(t) of an antibiotic in a patient's bloodstream is modeled by C(t)=80tt2+4C(t) = \frac{80t}{t^2 + 4}, where tt is measured in hours (h\text{h}) and CC is in milligrams per liter (mg/L\text{mg/L}). (a) Find the time tmaxt_{\text{max}} at which the absolute maximum concentration occurs on the interval [0,12][0, 12]. Show your calculus justification. (b) Express the instantaneous rate of change of concentration at t=1 ht = 1\text{ h} in units of micrograms per milliliter per minute (μg/(mL⋅min)\mu\text{g}/(\text{mL}\cdot\text{min})).

Answer and steps

Final answer

(a) tmax=2 ht_{\text{max}} = 2\text{ h}; C′(t)=80(4−t2)(t2+4)2C'(t) = \frac{80(4 - t^2)}{(t^2 + 4)^2}, which equals 00 on [0,12][0, 12] only at t=2t = 2. Evaluating endpoints and critical point: C(0)=0 mg/LC(0) = 0\text{ mg/L}, C(2)=20 mg/LC(2) = 20\text{ mg/L}, and C(12)=960148≈6.49 mg/LC(12) = \frac{960}{148} \approx 6.49\text{ mg/L}, confirming an absolute maximum of 20 mg/L20\text{ mg/L} at t=2 ht = 2\text{ h}. (b) 0.16 μg/(mL⋅min)0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}), since C′(1)=80(3)25=9.6 mg/(L⋅h)C'(1) = \frac{80(3)}{25} = 9.6\text{ mg}/(\text{L}\cdot\text{h}), and converting via 9.6 mg1 L⋅h×1000 μg1 mg×1 L1000 mL×1 h60 min=9.660=0.16 μg/(mL⋅min)\frac{9.6\text{ mg}}{1\text{ L}\cdot\text{h}} \times \frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} \times \frac{1\text{ h}}{60\text{ min}} = \frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}).

Steps

Part (a): Absolute Maximum Concentration on [0,12][0, 12]

To find the absolute maximum of the continuous function C(t)=80tt2+4C(t) = \frac{80t}{t^2 + 4} on the closed interval [0,12][0, 12], apply the Extreme Value Theorem by evaluating C(t)C(t) at any critical points in (0,12)(0, 12) and at the endpoints.

  1. Find the critical points using the Quotient Rule: Let u(t)=80tu(t) = 80t and v(t)=t2+4v(t) = t^2 + 4, with derivatives u′(t)=80u'(t) = 80 and v′(t)=2tv'(t) = 2t. C′(t)=u′(t)v(t)−u(t)v′(t)[v(t)]2=80(t2+4)−80t(2t)(t2+4)2C'(t) = \frac{u'(t)v(t) - u(t)v'(t)}{[v(t)]^2} = \frac{80(t^2 + 4) - 80t(2t)}{(t^2 + 4)^2} C′(t)=80t2+320−160t2(t2+4)2=320−80t2(t2+4)2=80(4−t2)(t2+4)2C'(t) = \frac{80t^2 + 320 - 160t^2}{(t^2 + 4)^2} = \frac{320 - 80t^2}{(t^2 + 4)^2} = \frac{80(4 - t^2)}{(t^2 + 4)^2}
  2. Solve for C′(t)=0C'(t) = 0: The derivative equals zero when the numerator is zero: 80(4−t2)=0  ⟹  4−t2=0  ⟹  t=±280(4 - t^2) = 0 \implies 4 - t^2 = 0 \implies t = \pm 2 Since the domain is [0,12][0, 12], the only interior critical point is t=2 ht = 2\text{ h}.
  3. Evaluate the function at the critical point and endpoints:

    • At the left endpoint: C(0)=80(0)02+4=0 mg/LC(0) = \frac{80(0)}{0^2 + 4} = 0\text{ mg/L}
    • At the critical point: C(2)=80(2)22+4=1608=20 mg/LC(2) = \frac{80(2)}{2^2 + 4} = \frac{160}{8} = 20\text{ mg/L}
    • At the right endpoint: C(12)=80(12)122+4=960148=24037≈6.49 mg/LC(12) = \frac{80(12)}{12^2 + 4} = \frac{960}{148} = \frac{240}{37} \approx 6.49\text{ mg/L}

Comparing these values, the absolute maximum concentration is 20 mg/L20\text{ mg/L}, which occurs at tmax=2 ht_{\text{max}} = 2\text{ h}.


Part (b): Instantaneous Rate of Change with Unit Conversion

  1. Evaluate the derivative at t=1 ht = 1\text{ h}: C′(1)=80(4−12)(12+4)2=80(3)52=24025=9.6 mg/(L⋅h)C'(1) = \frac{80(4 - 1^2)}{(1^2 + 4)^2} = \frac{80(3)}{5^2} = \frac{240}{25} = 9.6\text{ mg}/(\text{L}\cdot\text{h})
  2. Convert the units to μg/(mL⋅min)\mu\text{g}/(\text{mL}\cdot\text{min}): Use the standard conversion factors:

    • 1 mg=1000 μg1\text{ mg} = 1000\text{ }\mu\text{g}
    • 1 L=1000 mL1\text{ L} = 1000\text{ mL}
    • 1 h=60 min1\text{ h} = 60\text{ min}

    Set up dimensional analysis: 9.6 mg1 L⋅h×1000 μg1 mg×1 L1000 mL×1 h60 min\frac{9.6\text{ mg}}{1\text{ L}\cdot\text{h}} \times \frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} \times \frac{1\text{ h}}{60\text{ min}}

    Notice that the mass and volume conversion factors cancel each other out: 1000 μg1 mg×1 L1000 mL=1 μg/mLmg/L\frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} = 1\text{ }\frac{\mu\text{g}/\text{mL}}{\text{mg}/\text{L}}

    Therefore, only the time conversion factor affects the numerical value: C′(1)=9.660 μg/(mL⋅min)=0.16 μg/(mL⋅min)C'(1) = \frac{9.6}{60}\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}) = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the denominator when applying the quotient rule, resulting in an incorrect derivative and critical points.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    C′(t)=80(t2+4)−80t(2t)t2+4  ⟹  C′(t)=80t2+320−160t2t2+4  ⟹  C′(t)=320−80t2t2+4C'(t) = \frac{80(t^2 + 4) - 80t(2t)}{t^2 + 4} \implies C'(t) = \frac{80t^2 + 320 - 160t^2}{t^2 + 4} \implies C'(t) = \frac{320 - 80t^2}{t^2 + 4}

    Correct

    C′(t)=80(t2+4)−80t(2t)(t2+4)2=320−80t2(t2+4)2=80(4−t2)(t2+4)2C'(t) = \frac{80(t^2 + 4) - 80t(2t)}{(t^2 + 4)^2} = \frac{320 - 80t^2}{(t^2 + 4)^2} = \frac{80(4 - t^2)}{(t^2 + 4)^2}

    When applying the quotient rule (uv)′=u′v−uv′v2\left(\frac{u}{v}\right)' = \frac{u'v - uv'}{v^2}, the denominator must be squared as v2=(t2+4)2v^2 = (t^2 + 4)^2.

  2. Step 2

    320−80t2=0  ⟹  t2=4, so t=2  ⟹  C(0)=0,C(2)=20,C(12)=24037≈6.49  ⟹  tmax=2 h320 - 80t^2 = 0 \implies t^2 = 4, \text{ so } t = 2 \implies C(0) = 0, C(2) = 20, C(12) = \frac{240}{37} \approx 6.49 \implies t_{\text{max}} = 2\text{ h}

  3. Step 3

    C′(1)=320−80(1)1+4=2405=48 mg/(L⋅h)C'(1) = \frac{320 - 80(1)}{1 + 4} = \frac{240}{5} = 48\text{ mg}/(\text{L}\cdot\text{h})

    Correct

    C′(1)=320−80(1)2(12+4)2=24025=9.6 mg/(L⋅h)C'(1) = \frac{320 - 80(1)^2}{(1^2 + 4)^2} = \frac{240}{25} = 9.6\text{ mg}/(\text{L}\cdot\text{h})

    You substituted t=1t = 1 correctly into your derivative, but the missing squared denominator led to an evaluated rate of 4848 instead of 9.69.6.

  4. Step 4

    1 mg/L=1 μg/mL  ⟹  1 h=60 min  ⟹  4860=0.8 μg/(mL⋅min)1\text{ mg/L} = 1\text{ }\mu\text{g/mL} \implies 1\text{ h} = 60\text{ min} \implies \frac{48}{60} = 0.8\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Correct

    9.6 mg1 L⋅h×1000 μg1 mg×1 L1000 mL×1 h60 min=9.660=0.16 μg/(mL⋅min)\frac{9.6\text{ mg}}{1\text{ L}\cdot\text{h}} \times \frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} \times \frac{1\text{ h}}{60\text{ min}} = \frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Your unit conversion factor of dividing by 6060 is completely correct, but the final numerical value is affected by the earlier derivative error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the quotient rule numerator structure u′v−uv′u'v - uv'.

You correctly evaluated the function at critical points and interval boundaries to find the absolute maximum.

You recognized that 1 mg/L1\text{ mg/L} is equivalent to 1 μg/mL1\text{ }\mu\text{g/mL} and divided by 6060 to convert hours to minutes.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Quotient Rule Denominator Omission

You wrote t2+4t^2 + 4 in the denominator of C′(t)C'(t) instead of (t2+4)2(t^2 + 4)^2.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Forgetting the square on the denominator function v(x)v(x) in the quotient rule formula ddx[uv]=u′v−uv′v2\frac{d}{dx}\left[\frac{u}{v}\right] = \frac{u'v - uv'}{v^2}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Quotient Rule Formula Template
  • The derivative of a quotient is ddx[uv]=u′v−uv′v2\frac{d}{dx}\left[\frac{u}{v}\right] = \frac{u'v - uv'}{v^2}.

  • Always write down the denominator with an explicit square (v)2(v)^2 before expanding or simplifying terms.

Dimensional Unit Check
  • The rate of change C′(t)C'(t) has units of [C]/[t]=(mg/L)/h[C]/[t] = (\text{mg/L})/\text{h}.

  • Verify conversions factor by factor using dimensional analysis cancellation.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Use the correct derivative with the squared denominator: C′(t)=320−80t2(t2+4)2C'(t) = \frac{320 - 80t^2}{(t^2 + 4)^2}.

  2. Substitute t=1t = 1: C′(1)=320−80(1)2(12+4)2=24052=24025=9.6 mg/(L⋅h)C'(1) = \frac{320 - 80(1)^2}{(1^2 + 4)^2} = \frac{240}{5^2} = \frac{240}{25} = 9.6\text{ mg}/(\text{L}\cdot\text{h}).

  3. Apply the unit conversion factor 160\frac{1}{60}: 9.660=0.16 μg/(mL⋅min)\frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}).

Final answer

0.16 μg/(mL⋅min)0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check that you write the exponent 22 on the denominator every time you invoke the quotient rule.

  • Practice computing derivatives of rational functions and immediately evaluating them at given points.

  • Review unit conversion cancellation chains to ensure all intermediate units cancel properly.

OverviewACEpath Teacher's Diagnosis

02 The student multiplies by 60 instead of dividing by 60 when converting the time unit from per hour to per minute.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    C′(t)=80(t2+4)−80t(2t)(t2+4)2  ⟹  C′(t)=320−80t2(t2+4)2  ⟹  320−80t2=0  ⟹  t=2C'(t) = \frac{80(t^2 + 4) - 80t(2t)}{(t^2 + 4)^2} \implies C'(t) = \frac{320 - 80t^2}{(t^2 + 4)^2} \implies 320 - 80t^2 = 0 \implies t = 2

  2. Step 2

    C(0)=0, C(2)=20, C(12)=24037≈6.49  ⟹  tmax=2 hC(0) = 0,\ C(2) = 20,\ C(12) = \frac{240}{37} \approx 6.49 \implies t_{\text{max}} = 2\text{ h}

  3. Step 3

    C′(1)=320−80(1)(1+4)2=24025=9.6 mg/(L⋅h)C'(1) = \frac{320 - 80(1)}{(1 + 4)^2} = \frac{240}{25} = 9.6\text{ mg}/(\text{L}\cdot\text{h})

  4. Step 4

    1 mg/L=1 μg/mL  ⟹  9.6×60=576 μg/(mL⋅min)1\text{ mg/L} = 1\text{ }\mu\text{g/mL} \implies 9.6 \times 60 = 576\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Correct

    9.6 mg1 L⋅h×1 h60 min=9.660=0.16 μg/(mL⋅min)\frac{9.6\text{ mg}}{1\text{ L}\cdot\text{h}} \times \frac{1\text{ h}}{60\text{ min}} = \frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Because hours are in the denominator, replacing 1 h1\text{ h} with 60 min60\text{ min} places 6060 in the denominator, requiring division by 6060 rather than multiplication.

WHAT YOU DID WELL
Compliments from Your Teacher

You applied the Quotient Rule and simplified the derivative algebraically without error.

You used the closed interval method by comparing function values at the critical point and both endpoints.

You correctly calculated the instantaneous rate of change at t=1 ht = 1\text{ h}.

You recognized that 1 mg/L1\text{ mg}/\text{L} is equivalent to 1 μg/mL1\text{ }\mu\text{g}/\text{mL}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Denominator unit conversion inversion

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the unit of time as if it were in the numerator when converting from hours to minutes, forgetting that converting a unit in the denominator requires the conversion factor in the opposite orientation so that the original unit cancels.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Cancellation via Dimensional Analysis
  • To cancel a unit in the denominator, place that unit in the numerator of your conversion factor: 1h×1 h60 min=160 min\frac{1}{\text{h}} \times \frac{1\text{ h}}{60\text{ min}} = \frac{1}{60\text{ min}}.

  • Write out full unit fractions with explicit cancellation bars instead of multiplying or dividing by memory.

Reasonableness Check on Rate Magnitude
  • A rate per minute must be 160\frac{1}{60} of the rate per hour because far less change occurs in a single minute than in a full hour.

  • Check whether converting to a smaller time interval should make the numerical rate smaller or larger.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the dimensional analysis ratio: 9.6 mgL⋅h×1000 μg1 mg×1 L1000 mL×1 h60 min\frac{9.6\text{ mg}}{\text{L}\cdot\text{h}} \times \frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} \times \frac{1\text{ h}}{60\text{ min}}.

  2. Cancel matching mass and volume units: 10001000=1\frac{1000}{1000} = 1, leaving 9.660 μg/(mL⋅min)\frac{9.6}{60}\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}).

  3. Divide 9.69.6 by 6060: 9.660=0.16\frac{9.6}{60} = 0.16.

Final answer

0.16 μg/(mL⋅min)0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting compound rates where units appear in the denominator.

  • Always write out unit fractions to verify that original units cancel diagonally.

OverviewACEpath Teacher's Diagnosis

03 The student assumes 1 mg/L equals 1000 μg/mL by converting milligrams to micrograms while failing to convert liters to milliliters in the denominator.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    C′(t)=80(t2+4)−80t(2t)(t2+4)2  ⟹  C′(t)=320−80t2(t2+4)2C'(t) = \frac{80(t^2+4) - 80t(2t)}{(t^2+4)^2} \implies C'(t) = \frac{320 - 80t^2}{(t^2+4)^2}

  2. Step 2

    320−80t2=0  ⟹  t=2  ⟹  C(0)=0,  C(2)=20,  C(12)=24037≈6.49  ⟹  tmax=2 h320 - 80t^2 = 0 \implies t = 2 \implies C(0) = 0,\; C(2) = 20,\; C(12) = \frac{240}{37} \approx 6.49 \implies t_{\text{max}} = 2\text{ h}

  3. Step 3

    C′(1)=320−80(1)(1+4)2=9.6 mg/(L⋅h)C'(1) = \frac{320 - 80(1)}{(1+4)^2} = 9.6\text{ mg}/(\text{L}\cdot\text{h})

  4. Step 4

    1 mg/L=1000 μg/mL1\text{ mg/L} = 1000\text{ }\mu\text{g/mL}

    Correct

    1 mg/L=1000 μg1000 mL=1 μg/mL1\text{ mg/L} = \frac{1000\text{ }\mu\text{g}}{1000\text{ mL}} = 1\text{ }\mu\text{g/mL}

    You converted 1 mg1\text{ mg} to 1000 μg1000\text{ }\mu\text{g} in the numerator, but did not convert 1 L1\text{ L} to 1000 mL1000\text{ mL} in the denominator. Because both the mass and volume scale by a factor of 10001000, 1 mg/L1\text{ mg/L} is identically equal to 1 μg/mL1\text{ }\mu\text{g/mL}.

  5. Step 5

    9.6×100060=160 μg/(mL⋅min)\frac{9.6 \times 1000}{60} = 160\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Correct

    9.660=0.16 μg/(mL⋅min)\frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

    Your final calculation divided by 6060 minutes correctly, but carried over the extra factor of 10001000 from step 4.

WHAT YOU DID WELL
Compliments from Your Teacher

You found the first derivative accurately using the Quotient Rule.

You properly tested the critical point and interval endpoints to justify the absolute maximum.

You evaluated C′(1)C'(1) correctly with appropriate initial units of mg/(L⋅h)\text{mg}/(\text{L}\cdot\text{h}).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Incomplete compound unit conversion

You converted milligrams to micrograms in the numerator but forgot to convert liters to milliliters in the denominator.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Treating compound units as single units rather than writing full conversion fractions where numerator and denominator units cancel independently.

REASONING PATH
Your ACEpath teacher’s suggested approach
Set Up Explicit Conversion Factors
  • For compound units AB\frac{A}{B}, convert AA and BB independently using multiplying factors that equal 11: 1000 μg1 mg\frac{1000\text{ }\mu\text{g}}{1\text{ mg}} and 1 L1000 mL\frac{1\text{ L}}{1000\text{ mL}}.

  • Always write out each conversion ratio with its units so you can visually verify which units cancel.

Recognize Metric Concentration Equivalents
  • 1 mg/L=1 μg/mL=1 g/m3=1 ppm1\text{ mg/L} = 1\text{ }\mu\text{g/mL} = 1\text{ g/m}^3 = 1\text{ ppm} in dilute aqueous solutions.

  • Double-check compound metric ratios by comparing their scaling factors before multiplying.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the complete dimensional analysis expression: 9.6 mg1 L⋅h×1000 μg1 mg×1 L1000 mL×1 h60 min\frac{9.6\text{ mg}}{1\text{ L}\cdot\text{h}} \times \frac{1000\text{ }\mu\text{g}}{1\text{ mg}} \times \frac{1\text{ L}}{1000\text{ mL}} \times \frac{1\text{ h}}{60\text{ min}}.

  2. Cancel the mass units (mg\text{mg}) and volume units (L\text{L}): 1000 μg1000 mL=1 μgmL\frac{1000\text{ }\mu\text{g}}{1000\text{ mL}} = 1\text{ }\frac{\mu\text{g}}{\text{mL}}.

  3. Divide by the time conversion: 9.660=0.16 μg/(mL⋅min)\frac{9.6}{60} = 0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}).

Final answer

0.16 μg/(mL⋅min)0.16\text{ }\mu\text{g}/(\text{mL}\cdot\text{min})

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice compound dimensional analysis by explicitly writing fraction bars for every unit in the numerator and denominator.

  • Review common medical and chemical concentration equivalencies, especially mg/L≡μg/mL\text{mg/L} \equiv \mu\text{g/mL}.

Lock it in

Similar question

01

Find the derivative f′(x)f'(x) of the function f(x)=3xx2+1f(x) = \frac{3x}{x^2 + 1}, and evaluate f′(1)f'(1).

Answer

f′(x)=3(x2+1)−3x(2x)(x2+1)2=3−3x2(x2+1)2f'(x) = \frac{3(x^2 + 1) - 3x(2x)}{(x^2 + 1)^2} = \frac{3 - 3x^2}{(x^2 + 1)^2}. At x=1x = 1, f′(1)=3−3(1)(1+1)2=0f'(1) = \frac{3 - 3(1)}{(1 + 1)^2} = 0.

02

A substance concentration is given by S(t)=50tt2+9 mg/LS(t) = \frac{50t}{t^2 + 9}\text{ mg/L} for t≥0t \ge 0 in hours. Find the instantaneous rate of change of S(t)S(t) at t=1 ht = 1\text{ h} in mg/(L⋅h)\text{mg}/(\text{L}\cdot\text{h}).

Answer

S′(t)=50(t2+9)−50t(2t)(t2+9)2=450−50t2(t2+9)2S'(t) = \frac{50(t^2 + 9) - 50t(2t)}{(t^2 + 9)^2} = \frac{450 - 50t^2}{(t^2 + 9)^2}. At t=1t = 1, S′(1)=450−50(1)(1+9)2=400100=4 mg/(L⋅h)S'(1) = \frac{450 - 50(1)}{(1 + 9)^2} = \frac{400}{100} = 4\text{ mg}/(\text{L}\cdot\text{h}).

03

For the same function S(t)=50tt2+9 mg/LS(t) = \frac{50t}{t^2 + 9}\text{ mg/L}, convert the rate of change at t=1 ht = 1\text{ h} into units of μg/(mL⋅min)\mu\text{g}/(\text{mL}\cdot\text{min}). Note: 1 mg/L=1 μg/mL1\text{ mg/L} = 1\text{ }\mu\text{g/mL}.

Answer

From the previous exercise, S′(1)=4 mg/(L⋅h)=4 μg/(mL⋅h)S'(1) = 4\text{ mg}/(\text{L}\cdot\text{h}) = 4\text{ }\mu\text{g}/(\text{mL}\cdot\text{h}). Converting hours to minutes gives 460 μg/(mL⋅min)=115 μg/(mL⋅min)≈0.067 μg/(mL⋅min)\frac{4}{60}\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}) = \frac{1}{15}\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}) \approx 0.067\text{ }\mu\text{g}/(\text{mL}\cdot\text{min}).

Loading workspace…