Resources

An industrial wastewater treatment facility receives effluent with heavy metals. Stream A has a lead concentration of 120 ppm120\text{ ppm} and Stream B has a lead concentration of 40 ppm40\text{ ppm}. The plant must blend Stream A and Stream B to produce 25,000 liters25{,}000\text{ liters} of blended wastewater with a final target concentration of 0.068 g/L0.068\text{ g/L}. Given that 1 ppm=1 mg/L=10−3 g/L1\text{ ppm} = 1\text{ mg/L} = 10^{-3}\text{ g/L}, convert all concentrations into consistent units of g/L\text{g/L}, construct the system of linear equations modeling total volume and total dissolved lead mass, and solve for the required volume of each stream in liters.

Answer and steps

Final answer

Converting concentrations: Stream A is 120 mg/L=0.120 g/L120\text{ mg/L} = 0.120\text{ g/L} and Stream B is 40 mg/L=0.040 g/L40\text{ mg/L} = 0.040\text{ g/L}. Let VAV_A and VBV_B be the volumes in liters of Stream A and Stream B, respectively. The system of equations is: {VA+VB=25,0000.120VA+0.040VB=0.068(25,000)\begin{cases} V_A + V_B = 25{,}000 \\ 0.120V_A + 0.040V_B = 0.068(25{,}000) \end{cases}, which simplifies to {VA+VB=25,0000.120VA+0.040VB=1,700\begin{cases} V_A + V_B = 25{,}000 \\ 0.120V_A + 0.040V_B = 1{,}700 \end{cases}. The solution is VA=8,750 LV_A = 8{,}750\text{ L} and VB=16,250 LV_B = 16{,}250\text{ L}.

Steps

01

Convert all concentrations to consistent units (g/L\text{g/L})

The conversion factor given is 1 ppm=1 mg/L=10−3 g/L1\text{ ppm} = 1\text{ mg/L} = 10^{-3}\text{ g/L}.

  • Stream A: 120 ppm=120×10−3 g/L=0.120 g/L120\text{ ppm} = 120 \times 10^{-3}\text{ g/L} = 0.120\text{ g/L}
  • Stream B: 40 ppm=40×10−3 g/L=0.040 g/L40\text{ ppm} = 40 \times 10^{-3}\text{ g/L} = 0.040\text{ g/L}
  • Target Blend: Target concentration=0.068 g/L\text{Target concentration} = 0.068\text{ g/L}

02

Define variables and set up the system of linear equations

Let VAV_A represent the volume of Stream A in liters, and let VBV_B represent the volume of Stream B in liters.

  1. Total Volume Equation: The sum of the volumes of both streams must equal the total blended volume: VA+VB=25,000V_A + V_B = 25{,}000
  2. Total Dissolved Lead Mass Equation: Mass of lead=concentration×volume\text{Mass of lead} = \text{concentration} \times \text{volume} The mass of lead from Stream A plus the mass from Stream B equals the total lead mass in the blended mixture: 0.120VA+0.040VB=0.068⋅25,0000.120 V_A + 0.040 V_B = 0.068 \cdot 25{,}000 0.120VA+0.040VB=1,7000.120 V_A + 0.040 V_B = 1{,}700

Thus, the system of equations is: {VA+VB=25,000,0.120VA+0.040VB=1,700\lbrace V_A + V_B = 25{,}000, \quad 0.120 V_A + 0.040 V_B = 1{,}700

Common Pitfall: Forgetting to convert parts-per-million (ppm\text{ppm}) into g/L\text{g/L} before multiplying by volume in liters causes an inconsistency by a factor of 1,0001{,}000. Always check that all concentrations and volumes share matching base units.


03

Solve the system of equations

Express VBV_B in terms of VAV_A from the total volume equation: VB=25,000−VAV_B = 25{,}000 - V_A

Substitute this expression into the lead mass equation: 0.120VA+0.040(25,000−VA)=1,7000.120 V_A + 0.040(25{,}000 - V_A) = 1{,}700

Expand and combine like terms: 0.120VA+1,000−0.040VA=1,7000.120 V_A + 1{,}000 - 0.040 V_A = 1{,}700 0.080VA+1,000=1,7000.080 V_A + 1{,}000 = 1{,}700

Subtract 1,0001{,}000 from both sides: 0.080VA=7000.080 V_A = 700

Divide by 0.0800.080: VA=7000.080=8,750 LV_A = \frac{700}{0.080} = 8{,}750\text{ L}

Now find VBV_B: VB=25,000−8,750=16,250 LV_B = 25{,}000 - 8{,}750 = 16{,}250\text{ L}

Stream A requires 8,750 L8{,}750\text{ L} and Stream B requires 16,250 L16{,}250\text{ L}.

Educational illustration for this question

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to multiply the target concentration by the total volume on the right-hand side of the mass balance equation, equating total dissolved lead mass directly to 0.068.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Stream A: 120 ppm = 0.12 g/L ⟹ Stream B: 40 ppm = 0.04 g/L

  2. Step 2

    A + B = 25000

  3. Step 3

    0.12A + 0.04B = 0.068

    Correct

    0.12A+0.04B=0.068(25,000)=1,7000.12A + 0.04B = 0.068(25{,}000) = 1{,}700

    The left side represents total mass in grams ((g/L)×L=g(\text{g/L}) \times \text{L} = \text{g}), while the right side was written as just the target concentration 0.068 g/L0.068\text{ g/L}. You must multiply the final target concentration by the total mixture volume to obtain total lead mass in grams.

  4. Step 4

    B = 25000 - A ⟹ 0.12A + 0.04(25000 - A) = 0.068 ⟹ 0.08A + 1000 = 0.068 ⟹ 0.08A = -999.932

    Correct

    B=25,000−A⟹0.12A+0.04(25,000−A)=1,700⟹0.08A+1,000=1,700⟹0.08A=700B = 25{,}000 - A ⟹ 0.12A + 0.04(25{,}000 - A) = 1{,}700 ⟹ 0.08A + 1{,}000 = 1{,}700 ⟹ 0.08A = 700

    Your algebraic substitution and manipulation steps were carried out correctly, but the equation carried the incorrect constant term from the previous step.

  5. Step 5

    A = -12499.15 L , B = 37499.15 L

    Correct

    A=8,750 L,B=16,250 LA = 8{,}750\text{ L}, B = 16{,}250\text{ L}

    The resulting negative volume for stream AA is an impossible physical quantity caused by the missing volume factor on the right-hand side.

WHAT YOU DID WELL
Compliments from Your Teacher

You converted ppm\text{ppm} to g/L\text{g/L} accurately using the given conversion factor.

You set up the volume balance equation A+B=25,000A + B = 25{,}000 correctly.

You executed the substitution method with correct algebraic mechanics.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Dimensional Inconsistency in Mixture Balance

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the target concentration as total solute mass, equating a mass expression on the left-hand side with a concentration value on the right-hand side without multiplying by the total mixture volume.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Check on Equation Terms
  • Every additive term across both sides of a balance equation must have identical physical units.

  • Check each term: 0.12 g/L×A L=0.12A g0.12\text{ g/L} \times A\text{ L} = 0.12A\text{ g}. Therefore, the right side must also evaluate to grams: Cfinal×Vtotal=0.068 g/L×25,000 L=1,700 gC_{\text{final}} \times V_{\text{total}} = 0.068\text{ g/L} \times 25{,}000\text{ L} = 1{,}700\text{ g}.

Physical Reality Check
  • Physical mixture volumes cannot be negative.

  • If your solution yields a negative volume or a volume larger than the blended total, re-examine the right-hand side constants of your equations.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Expand the expression: 0.12A+1,000−0.04A=1,7000.12A + 1{,}000 - 0.04A = 1{,}700.

  2. Combine like terms: 0.08A+1,000=1,7000.08A + 1{,}000 = 1{,}700.

  3. Subtract 1,0001{,}000 from both sides: 0.08A=7000.08A = 700.

  4. Divide by 0.080.08: A=7000.08=8,750 LA = \frac{700}{0.08} = 8{,}750\text{ L}.

  5. Substitute back to find BB: B=25,000−8,750=16,250 LB = 25{,}000 - 8{,}750 = 16{,}250\text{ L}.

Final answer

A=8,750 L,B=16,250 LA = 8{,}750\text{ L},\quad B = 16{,}250\text{ L}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write units beside every term in mixture equations to confirm that mass=concentration×volume\text{mass} = \text{concentration} \times \text{volume} across both sides.

  • Practice identifying the difference between concentration (CC) and total mass (C×VC \times V) before solving the linear system.

OverviewACEpath Teacher's Diagnosis

02 The student misapplies the unit conversion factor by multiplying by 1000 instead of dividing by 1000, setting 120 ppm as 120000 g/L and 40 ppm as 40000 g/L.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Stream A: 120 ×\times 1000 = 120000 g/L\text{ g/L}   ⟹  \implies Stream B: \text{Stream B: } 40 ×\times 1000 = 40000 g/L\text{ g/L}

    Correct

    Stream A: 120 ×\times 10^{-3} g/L\text{ g/L} = 0.120 g/L\text{ g/L}   ⟹  \implies Stream B: \text{Stream B: } 40 ×\times 10^{-3} g/L\text{ g/L} = 0.040 g/L\text{ g/L}

    Because 1 ppm=10−3 g/L1\text{ ppm} = 10^{-3}\text{ g/L}, you need to multiply the ppm value by 10−310^{-3} (or divide by 1,0001{,}000). Multiplying by 1,0001{,}000 made the concentrations one million times larger than they actually are.

  2. Step 2

    A + B = 25000   ⟹  \implies 120000A + 40000B = 0.068 ×\times 25000   ⟹  \implies 120000A + 40000B = 1700

    Correct

    \lbrace A + B = 25{,}000 ,  0.120A + 0.040B = 1{,}700

    Your system setup correctly matched volume conservation and lead mass conservation, but the equation inherited the inflated concentration values from Step 1.

  3. Step 3

    B = 25000 - A   ⟹  \implies 120000A + 40000(25000 - A) = 1700   ⟹  \implies 80000A + 1000000000 = 1700   ⟹  \implies 80000A = -999998300

    Correct

    B = 25{,}000 - A   ⟹  \implies 0.120A + 0.040(25{,}000 - A) = 1{,}700   ⟹  \implies 0.080A = 700

    You executed substitution and algebraic simplification without any arithmetic slips on your numbers, but the inflated values led to an equation where the constant term overwhelmed the right-hand side.

  4. Step 4

    A ≈\approx -12499.98 L\text{ L},  B ≈\approx 37499.98 L\text{ L}

    Correct

    A = 8{,}750 L\text{ L},  B = 16{,}250 L\text{ L}

    Because of the earlier conversion error, your final volumes were physically impossible (a negative volume for Stream A). When working with physical quantities, a negative volume is a clear sign to revisit your initial units.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the two governing physical constraints: total volume conservation and total dissolved mass conservation.

You accurately substituted B=25,000−AB = 25{,}000 - A into your mass equation and performed correct multi-digit algebraic manipulation.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion inversion

You wrote ×1000\times 1000 instead of ×10−3\times 10^{-3} when converting from ppm\text{ppm} (extmg/L ext{mg/L}) to g/L\text{g/L}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Inverting the conversion factor between smaller and larger metric units: milligrams are smaller than grams (1 mg=10−3 g1\text{ mg} = 10^{-3}\text{ g}), so moving from mg/L\text{mg/L} to g/L\text{g/L} requires dividing by 1,0001{,}000, not multiplying.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Magnitude Sanity Check
  • When converting a quantity from a smaller unit to a larger base unit, the numerical value must decrease.

  • Check whether 120 mg120\text{ mg} should be a fraction of a gram or thousands of grams. Since 1 g=1,000 mg1\text{ g} = 1{,}000\text{ mg}, 120 mg=0.12 g120\text{ mg} = 0.12\text{ g}.

Physical Reality Check
  • Blended volumes and concentrations in mixture problems must be non-negative and lie between the component extremes.

  • Verify that target concentration 0.068 g/L0.068\text{ g/L} lies between Stream B (0.040 g/L0.040\text{ g/L}) and Stream A (0.120 g/L0.120\text{ g/L}), meaning both volumes must be positive numbers between 00 and 25,000 L25{,}000\text{ L}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert concentrations correctly: 120 ppm=120×10−3 g/L=0.120 g/L120\text{ ppm} = 120 \times 10^{-3}\text{ g/L} = 0.120\text{ g/L}, and 40 ppm=40×10−3 g/L=0.040 g/L40\text{ ppm} = 40 \times 10^{-3}\text{ g/L} = 0.040\text{ g/L}.

  2. Set up the system: {A+B=25,000,0.120A+0.040B=0.068(25,000)=1,700\lbrace A + B = 25{,}000 ,\quad 0.120A + 0.040B = 0.068(25{,}000) = 1{,}700.

  3. Substitute B=25,000−AB = 25{,}000 - A into the mass equation: 0.120A+0.040(25,000−A)=1,7000.120A + 0.040(25{,}000 - A) = 1{,}700.

  4. Simplify: 0.080A+1,000=1,700  ⟹  0.080A=700  ⟹  A=8,750 L0.080A + 1{,}000 = 1{,}700 \implies 0.080A = 700 \implies A = 8{,}750\text{ L}.

  5. Find BB: B=25,000−8,750=16,250 LB = 25{,}000 - 8{,}750 = 16{,}250\text{ L}.

Final answer

Stream A requires 8,750 L8{,}750\text{ L} and Stream B requires 16,250 L16{,}250\text{ L}.

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the direction of metric prefixes: milli (10−310^{-3}) means dividing by 1,0001{,}000 to get to base units.

  • Use dimensional analysis with explicit unit fractions like 1 g1,000 mg\frac{1\text{ g}}{1{,}000\text{ mg}} so that unwanted units visibly cancel.

  • Whenever a mixture problem yields a negative volume, immediately inspect your concentration units before re-doing the algebra.

OverviewACEpath Teacher's Diagnosis

03 The student swaps the concentrations of Stream A and Stream B in the mass balance equation, resulting in inverted volume requirements.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Stream A:120 ppm=0.12 g/L  ⟹  Stream B:40 ppm=0.04 g/L\text{Stream A}: 120\text{ ppm} = 0.12\text{ g/L} \implies \text{Stream B}: 40\text{ ppm} = 0.04\text{ g/L}

  2. Step 2

    A+B=25000A + B = 25000

  3. Step 3

    0.04A+0.12B=0.068×25000  ⟹  0.04A+0.12B=17000.04A + 0.12B = 0.068 \times 25000 \implies 0.04A + 0.12B = 1700

    Correct

    0.120A+0.040B=0.068(25,000)  ⟹  0.120A+0.040B=1,7000.120 A + 0.040 B = 0.068(25{,}000) \implies 0.120 A + 0.040 B = 1{,}700

    You swapped the concentrations of the two streams: Stream A has a concentration of 0.12 g/L0.12\text{ g/L} and Stream B has 0.04 g/L0.04\text{ g/L}, but you multiplied AA by 0.040.04 and BB by 0.120.12.

  4. Step 4

    B=25000−A  ⟹  0.04A+0.12(25000−A)=1700  ⟹  −0.08A+3000=1700  ⟹  −0.08A=−1300B = 25000 - A \implies 0.04A + 0.12(25000 - A) = 1700 \implies -0.08A + 3000 = 1700 \implies -0.08A = -1300

    Correct

    B=25,000−A  ⟹  0.120A+0.040(25,000−A)=1,700  ⟹  0.080A+1,000=1,700  ⟹  0.080A=700B = 25{,}000 - A \implies 0.120A + 0.040(25{,}000 - A) = 1{,}700 \implies 0.080A + 1{,}000 = 1{,}700 \implies 0.080A = 700

    Your algebraic substitution and linear equation solving steps were carried out correctly, but they inherited the reversed coefficients from Step 3.

  5. Step 5

    A=16250 L,B=8750 LA = 16250\text{ L},\quad B = 8750\text{ L}

    Correct

    A=8,750 L,B=16,250 LA = 8{,}750\text{ L},\quad B = 16{,}250\text{ L}

    Because the coefficients were transposed in the mass balance equation, the calculated volumes for Stream A and Stream B ended up switched.

WHAT YOU DID WELL
Compliments from Your Teacher

You converted concentration values from ppm\text{ppm} to g/L\text{g/L} accurately.

You set up the total volume relationship correctly.

You executed the substitution method and solved the resulting linear equation without algebraic errors.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Variable-Coefficient Mismatch

You assigned the concentration of Stream B (0.04 g/L0.04\text{ g/L}) to variable AA and the concentration of Stream A (0.12 g/L0.12\text{ g/L}) to variable BB.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

In multi-stream mixture problems, defining variables verbally without explicitly pairing each variable with its associated rate or concentration on paper often leads to transposing coefficients during equation assembly.

REASONING PATH
Your ACEpath teacher’s suggested approach
Match Rates to Variables
  • Every term in a solute mass equation must follow Mass=(Concentrationi)×(Volumei)\text{Mass} = (\text{Concentration}_i) \times (\text{Volume}_i).

  • Write out the labeled product pairs explicitly, such as (0.120 g/L)⋅VA(0.120\text{ g/L}) \cdot V_A and (0.040 g/L)⋅VB(0.040\text{ g/L}) \cdot V_B, before assembling the equation.

Target Concentration Sanity Check
  • If the target concentration is closer to Stream B than Stream A, the required mixture must contain more of Stream B.

  • Compare 0.0680.068 to the endpoints 0.0400.040 and 0.1200.120: since 0.0680.068 is closer to 0.0400.040, verify that VB>VAV_B > V_A before finalizing the answer.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Pair each stream volume with its own concentration to write the correct mass equation: 0.120A+0.040B=0.068(25,000)=1,7000.120A + 0.040B = 0.068(25{,}000) = 1{,}700

  2. Substitute B=25,000−AB = 25{,}000 - A into the corrected mass equation: 0.120A+0.040(25,000−A)=1,7000.120A + 0.040(25{,}000 - A) = 1{,}700

  3. Expand and combine like terms: 0.120A+1,000−0.040A=1,700  ⟹  0.080A=7000.120A + 1{,}000 - 0.040A = 1{,}700 \implies 0.080A = 700

  4. Solve for AA: A=7000.080=8,750 LA = \frac{700}{0.080} = 8{,}750\text{ L}

  5. Calculate BB: B=25,000−8,750=16,250 LB = 25{,}000 - 8{,}750 = 16{,}250\text{ L}

Final answer

A=8,750 L,B=16,250 LA = 8{,}750\text{ L},\quad B = 16{,}250\text{ L}

NEXT STEPS
Final Takeaways from Your Teacher
  • Before writing down the mixture equation, write a small reference table linking each variable symbol directly below its corresponding concentration.

  • Perform a weighted-average proximity check at the end to ensure the larger volume corresponds to the stream whose concentration is closer to the target.

Lock it in

Similar question

01

A chemist mixes a 15%15\% acid solution with a 40%40\% acid solution to obtain 50 L50\text{ L} of a 30%30\% acid solution. Set up the system of linear equations modeling the total liquid volume and total pure acid volume.

Answer

Let xx be the volume of the 15%15\% solution and yy be the volume of the 40%40\% solution. Total volume equation: x+y=50x + y = 50. Pure acid equation: 0.15x+0.40y=0.30(50)0.15x + 0.40y = 0.30(50), which simplifies to 0.15x+0.40y=150.15x + 0.40y = 15.

02

A reservoir needs 10,000 L10{,}000\text{ L} of saline solution at a concentration of 0.025 kg/L0.025\text{ kg/L}. Two supply pipes deliver brine at 0.010 kg/L0.010\text{ kg/L} and 0.060 kg/L0.060\text{ kg/L} respectively. Find the required volume from each pipe.

Answer

7,000 L7{,}000\text{ L} of the 0.010 kg/L0.010\text{ kg/L} brine and 3,000 L3{,}000\text{ L} of the 0.060 kg/L0.060\text{ kg/L} brine. Let x+y=10,000x + y = 10{,}000 and 0.010x+0.060y=0.025(10,000)=2500.010x + 0.060y = 0.025(10{,}000) = 250. Substituting y=10,000−xy = 10{,}000 - x yields 0.010x+600−0.060x=250  ⟹  −0.050x=−350  ⟹  x=7,0000.010x + 600 - 0.060x = 250 \implies -0.050x = -350 \implies x = 7{,}000, and y=3,000y = 3{,}000.

03

An environmental engineer mixes Stream 1 (80 ppm80\text{ ppm} contaminant) and Stream 2 (200 ppm200\text{ ppm} contaminant) to produce 12,000 L12{,}000\text{ L} with a target concentration of 0.13 g/L0.13\text{ g/L}. Given 1 ppm=10−3 g/L1\text{ ppm} = 10^{-3}\text{ g/L}, determine how many liters of Stream 1 are required.

Answer

7,000 L7{,}000\text{ L} of Stream 1. Convert concentrations: Stream 1 is 0.080 g/L0.080\text{ g/L} and Stream 2 is 0.200 g/L0.200\text{ g/L}. Set up the system: V1+V2=12,000V_1 + V_2 = 12{,}000 and 0.080V1+0.200V2=0.13(12,000)=1,5600.080V_1 + 0.200V_2 = 0.13(12{,}000) = 1{,}560. Substitute V2=12,000−V1V_2 = 12{,}000 - V_1: 0.080V1+0.200(12,000−V1)=1,560  ⟹  −0.120V1+2,400=1,560  ⟹  −0.120V1=−840  ⟹  V1=7,000 L0.080V_1 + 0.200(12{,}000 - V_1) = 1{,}560 \implies -0.120V_1 + 2{,}400 = 1{,}560 \implies -0.120V_1 = -840 \implies V_1 = 7{,}000\text{ L}.

Loading workspace…