Resources

A standard electrochemical cell based on the alkaline battery chemistry operates via the overall redox reaction: Zn(s)+2MnO2(s)+H2O(l)→ZnO(s)+2MnO(OH)(s)\text{Zn}(s) + 2\text{MnO}_2(s) + \text{H}_2\text{O}(l) \rightarrow \text{ZnO}(s) + 2\text{MnO}(\text{OH})(s). The standard reduction potentials are E∘=−1.28 VE^\circ = -1.28\text{ V} for the zinc half-reaction in alkaline medium ZnO(s)+H2O(l)+2e−→Zn(s)+2OH−(aq)\text{ZnO}(s) + \text{H}_2\text{O}(l) + 2e^- \rightarrow \text{Zn}(s) + 2\text{OH}^-(aq) and E∘=+0.15 VE^\circ = +0.15\text{ V} for the manganese dioxide half-reaction MnO2(s)+H2O(l)+e−→MnO(OH)(s)+OH−(aq)\text{MnO}_2(s) + \text{H}_2\text{O}(l) + e^- \rightarrow \text{MnO}(\text{OH})(s) + \text{OH}^-(aq). Calculate the standard cell potential Ecell∘E^\circ_{\text{cell}} for this battery under standard conditions.

Answer and steps

Final answer

Ecell∘=+1.43 VE^\circ_{\text{cell}} = +1.43\text{ V}

Steps

01

Identify the oxidation and reduction half-reactions

To find the standard cell potential (Ecell∘E^\circ_{\text{cell}}), determine which half-reaction takes place at the cathode (reduction) and which takes place at the anode (oxidation).

Look at the change in oxidation states in the overall reaction: Zn(s)+2MnOX2(s)+HX2O(l)→ZnO(s)+2MnO(OH)(s)\ce{Zn}(s) + 2\ce{MnO2}(s) + \ce{H2O}(l) \rightarrow \ce{ZnO}(s) + 2\ce{MnO(OH)}(s)

  • Anode (Oxidation): Zinc (Zn\ce{Zn}) increases in oxidation state from 00 to +2+2 in ZnO\ce{ZnO}, losing electrons: Zn(s)+2OH−(aq)→ZnO(s)+HX2O(l)+2e−\ce{Zn}(s) + 2\ce{OH}^-(aq) \rightarrow \ce{ZnO}(s) + \ce{H2O}(l) + 2e^- The given standard reduction potential for this zinc couple is: Eanode∘=−1.28 VE^\circ_{\text{anode}} = -1.28\text{ V}
  • Cathode (Reduction): Manganese (Mn\ce{Mn}) decreases in oxidation state from +4+4 in MnOX2\ce{MnO2} to +3+3 in MnO(OH)\ce{MnO(OH)}, gaining electrons: MnOX2(s)+HX2O(l)+e−→MnO(OH)(s)+OH−(aq)\ce{MnO2}(s) + \ce{H2O}(l) + e^- \rightarrow \ce{MnO(OH)}(s) + \ce{OH}^-(aq) The standard reduction potential for this manganese couple is: Ecathode∘=+0.15 VE^\circ_{\text{cathode}} = +0.15\text{ V}

02

Calculate the standard cell potential (Ecell∘E^\circ_{\text{cell}})

Using the standard reduction potentials of the cathode and anode: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}

Substitute the values: Ecell∘=(+0.15 V)−(−1.28 V)E^\circ_{\text{cell}} = (+0.15\text{ V}) - (-1.28\text{ V}) Ecell∘=0.15 V+1.28 V=+1.43 VE^\circ_{\text{cell}} = 0.15\text{ V} + 1.28\text{ V} = +1.43\text{ V}


Common Pitfalls to Avoid

  • Stoichiometry does not change E∘E^\circ: Even though the manganese half-reaction is multiplied by 22 to balance the two electrons transferred, standard electrode potential is an intensive property and must not be multiplied by stoichiometric coefficients.
  • Double-counting negative signs: When applying the formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, both potentials must be entered as standard reduction potentials. Do not manually flip the sign of Eanode∘E^\circ_{\text{anode}} before subtracting it.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student multiplies the standard reduction potential of the cathode half-reaction by 2 to balance electrons before calculating E°_cell, incorrectly treating standard reduction potential as an extensive property.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Cathode: E∘=2×(+0.15 V)=+0.30 V\text{Cathode: } E^\circ = 2 \times (+0.15\text{ V}) = +0.30\text{ V}

    Correct

    Cathode: E∘=+0.15 V\text{Cathode: } E^\circ = +0.15\text{ V}

    You multiplied the reduction potential by 22 to match the stoichiometry. Standard reduction potential (E∘E^\circ) is an intensive property and represents potential energy per unit charge (J/C\text{J}/\text{C}), so it does not change when a half-reaction is multiplied by a coefficient.

  2. Step 2

    Anode: E∘=−1.28 V\text{Anode: } E^\circ = -1.28\text{ V}

  3. Step 3

    Ecell∘=E∘(cathode)−E∘(anode)  ⟹  Ecell∘=+0.30 V−(−1.28 V)=+1.58 VE^\circ_{\text{cell}} = E^\circ(\text{cathode}) - E^\circ(\text{anode}) \implies E^\circ_{\text{cell}} = +0.30\text{ V} - (-1.28\text{ V}) = +1.58\text{ V}

    Correct

    Ecell∘=E∘(cathode)−E∘(anode)=+0.15 V−(−1.28 V)=+1.43 VE^\circ_{\text{cell}} = E^\circ(\text{cathode}) - E^\circ(\text{anode}) = +0.15\text{ V} - (-1.28\text{ V}) = +1.43\text{ V}

    You applied the correct cell potential equation and handled the signs properly, but your final result was affected by substituting the multiplied cathode potential.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified which half-reaction occurs at the cathode and which occurs at the anode.

You used the correct relationship Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

You correctly handled the double negative when subtracting −1.28 V-1.28\text{ V}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Treated intensive potential as extensive

You scaled the standard electrode potential by the stoichiometric factor of 2.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing standard electrode potential (E∘E^\circ, an intensive property) with Gibbs free energy change (ΔG∘\Delta G^\circ, an extensive property) when balancing redox electrons.

REASONING PATH
Your ACEpath teacher’s suggested approach
Intensive vs. Extensive
  • E∘E^\circ is an intensive property (volts = joules per coulomb) and never changes when multiplying half-reactions by stoichiometric integers.

  • Leave standard reduction potentials unchanged regardless of the multiplier used to balance electrons.

Cell Potential Formula
  • Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, where both values are standard reduction potentials.

  • Directly substitute tabulated standard reduction potentials without scaling or pre-flipping signs.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set Ecathode∘=+0.15 VE^\circ_{\text{cathode}} = +0.15\text{ V} without scaling by stoichiometric coefficients.

  2. Keep Eanode∘=−1.28 VE^\circ_{\text{anode}} = -1.28\text{ V}.

  3. Calculate Ecell∘=Ecathode∘−Eanode∘=+0.15 V−(−1.28 V)=+1.43 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.15\text{ V} - (-1.28\text{ V}) = +1.43\text{ V}.

Final answer

Ecell∘=+1.43 VE^\circ_{\text{cell}} = +1.43\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the distinction between intensive thermodynamic variables (E∘E^\circ, TT, PP) and extensive variables (ΔG∘\Delta G^\circ, ΔH∘\Delta H^\circ, nn).

  • Practice calculating Ecell∘E^\circ_{\text{cell}} for redox reactions where the two half-reactions transfer different numbers of electrons.

OverviewACEpath Teacher's Diagnosis

02 The student reverses the sign of the anode potential to represent the oxidation potential and then subtracts it in E°_cell = E°(cathode) - E°(anode), effectively subtracting the positive oxidation potential and resulting in -1.13 V.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Cathode: E∘=+0.15 V  ⟹  Anode: E∘(ox)=+1.28 V\text{Cathode: } E^\circ = +0.15\text{ V} \implies \text{Anode: } E^\circ(\text{ox}) = +1.28\text{ V}

  2. Step 2

    Ecell∘=0.15 V−1.28 V=−1.13 VE^\circ_{\text{cell}} = 0.15\text{ V} - 1.28\text{ V} = -1.13\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=(+0.15 V)−(−1.28 V)=+1.43 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = (+0.15\text{ V}) - (-1.28\text{ V}) = +1.43\text{ V}

    You subtracted your reversed oxidation potential (+1.28 V+1.28\text{ V}) instead of adding it. If you use the subtraction formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, both values must remain standard reduction potentials. Alternatively, if you flip the sign to find Eox∘E^\circ_{\text{ox}}, you must add them: Ecell∘=Ered∘(cathode)+Eox∘(anode)=0.15 V+1.28 V=+1.43 VE^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) + E^\circ_{\text{ox}}(\text{anode}) = 0.15\text{ V} + 1.28\text{ V} = +1.43\text{ V}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified which species is reduced at the cathode and which is oxidized at the anode.

You extracted the correct numerical values from the given standard reduction potentials.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Double Sign Inversion in Cell Potential Calculation

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating two distinct cell potential formulas: Ecell∘=Ered∘(cathode)−Ered∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}) versus Ecell∘=Ered∘(cathode)+Eox∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) + E^\circ_{\text{ox}}(\text{anode}). Flipping the sign of the anode potential and then subtracting it applies the negative sign twice, incorrectly yielding a negative cell potential for a galvanic cell.

REASONING PATH
Your ACEpath teacher’s suggested approach
Choose One Consistent Formula
  • Use either Ecell∘=Ered∘(cathode)−Ered∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}) (subtract standard reduction potentials directly) OR Ecell∘=Ered∘(cathode)+Eox∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) + E^\circ_{\text{ox}}(\text{anode}) (add reduction and oxidation potentials).

  • Never flip the sign of the anode reduction potential and then subtract it.

Galvanic Cell Sanity Check
  • Operating commercial batteries are galvanic cells, which must have a positive standard cell potential (Ecell∘>0E^\circ_{\text{cell}} > 0).

  • If your calculated Ecell∘E^\circ_{\text{cell}} for a spontaneous battery is negative, immediately check for sign errors.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify standard reduction potentials: Ered∘(cathode)=+0.15 VE^\circ_{\text{red}}(\text{cathode}) = +0.15\text{ V} and Ered∘(anode)=−1.28 VE^\circ_{\text{red}}(\text{anode}) = -1.28\text{ V}.

  2. Apply the reduction-potential formula: Ecell∘=Ered∘(cathode)−Ered∘(anode)=(+0.15 V)−(−1.28 V)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}) = (+0.15\text{ V}) - (-1.28\text{ V}).

  3. Simplify: Ecell∘=0.15 V+1.28 V=+1.43 VE^\circ_{\text{cell}} = 0.15\text{ V} + 1.28\text{ V} = +1.43\text{ V}.

Final answer

Ecell∘=+1.43 VE^\circ_{\text{cell}} = +1.43\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Pick one convention—preferably Ecathode∘−Eanode∘E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} using only tabulated reduction potentials—and stick with it throughout all electrochemistry problems.

  • Always perform a quick sanity check: spontaneous electrochemical cells (batteries) must always have Ecell∘>0E^\circ_{\text{cell}} > 0.

OverviewACEpath Teacher's Diagnosis

03 The student reverses the roles of cathode and anode, computing E°_cell = E°(anode) - E°(cathode) to get -1.43 V.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Ecell∘=E∘(Zn)−E∘(MnO2)E^\circ_{\text{cell}} = E^\circ(\text{Zn}) - E^\circ(\text{MnO}_2)

    Correct

    Ecell∘=Ecathode∘−Eanode∘=E∘(MnO2)−E∘(Zn)E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = E^\circ(\text{MnO}_2) - E^\circ(\text{Zn})

    You subtracted the reduction potential of the cathode from that of the anode. Because Zn\text{Zn} is oxidized from 00 to +2+2 at the anode and MnO2\text{MnO}_2 is reduced from +4+4 to +3+3 at the cathode, the correct relationship is Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  2. Step 2

    Ecell∘=−1.28 V−0.15 V=−1.43 VE^\circ_{\text{cell}} = -1.28\text{ V} - 0.15\text{ V} = -1.43\text{ V}

    Correct

    Ecell∘=0.15 V−(−1.28 V)=+1.43 VE^\circ_{\text{cell}} = 0.15\text{ V} - (-1.28\text{ V}) = +1.43\text{ V}

    Your arithmetic was accurate for the expression you set up, but the value is negative because the order of subtraction in Step 1 was inverted.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the two given standard reduction potentials from the half-reactions.

You performed the arithmetic subtraction correctly according to your written formula.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reversed cathode and anode in standard cell potential formula

You set up the formula as anode minus cathode instead of cathode minus anode.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You associated the leftmost reactant (Zn) with the leading term of the subtraction rather than determining which species undergoes reduction (cathode) versus oxidation (anode). Galvanic cells operate spontaneously with a positive standard potential (Ecell∘>0E^\circ_{\text{cell}} > 0).

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify Cathode vs. Anode
  • Reduction occurs at the cathode (gain of electrons, decrease in oxidation state); oxidation occurs at the anode (loss of electrons, increase in oxidation state).

  • Assign oxidation states to determine which species is reduced, and place that half-cell potential first: Ecathode∘E^\circ_{\text{cathode}}.

Standard Cell Potential Formula
  • When both values are tabulated standard reduction potentials, Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  • Always subtract the anode's standard reduction potential from the cathode's standard reduction potential.

Sanity Check for Batteries
  • A functioning galvanic or voltaic cell must have a positive standard cell potential (Ecell∘>0E^\circ_{\text{cell}} > 0).

  • If your battery calculation yields a negative voltage, re-check whether you swapped the cathode and anode.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Determine which substance is reduced: in MnO2\text{MnO}_2, manganese goes from +4+4 to +3+3, so MnO2\text{MnO}_2 is reduced at the cathode (Ecathode∘=+0.15 VE^\circ_{\text{cathode}} = +0.15\text{ V}).

  2. Determine which substance is oxidized: zinc goes from 00 to +2+2, so Zn\text{Zn} is oxidized at the anode (Eanode∘=−1.28 VE^\circ_{\text{anode}} = -1.28\text{ V}).

  3. Apply the standard cell potential equation: Ecell∘=Ecathode∘−Eanode∘=+0.15 V−(−1.28 V)E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.15\text{ V} - (-1.28\text{ V}).

  4. Evaluate the arithmetic: Ecell∘=0.15 V+1.28 V=+1.43 VE^\circ_{\text{cell}} = 0.15\text{ V} + 1.28\text{ V} = +1.43\text{ V}.

Final answer

Ecell∘=+1.43 VE^\circ_{\text{cell}} = +1.43\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the half-reaction labels 'Cathode (reduction)' and 'Anode (oxidation)' before writing numbers.

  • Check that Ecell∘>0E^\circ_{\text{cell}} > 0 whenever calculating the potential of a galvanic cell or battery.

Lock it in

Similar question

01

A galvanic cell uses the reaction 3 AgX+(aq)+Al(s)→3 Ag(s)+AlX3+(aq)\ce{3Ag+(aq) + Al(s) -> 3Ag(s) + Al^3+(aq)}. Given E∘(AgX+/Ag)=+0.80 VE^\circ(\ce{Ag+/Ag}) = +0.80\text{ V} and E∘(AlX3+/Al)=−1.66 VE^\circ(\ce{Al^3+/Al}) = -1.66\text{ V}, calculate Ecell∘E^\circ_{\text{cell}}.

Answer

Ecell∘=+2.46 VE^\circ_{\text{cell}} = +2.46\text{ V}. Identify cathode (reduction of AgX+\ce{Ag+}) and anode (oxidation of Al\ce{Al}). Do not multiply +0.80 V+0.80\text{ V} by 3. Compute Ecell∘=Ecathode∘−Eanode∘=+0.80 V−(−1.66 V)=+2.46 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.80\text{ V} - (-1.66\text{ V}) = +2.46\text{ V}.

02

For the reaction 2 FeX3+(aq)+SnX2+(aq)→2 FeX2+(aq)+SnX4+(aq)\ce{2Fe^3+(aq) + Sn^2+(aq) -> 2Fe^2+(aq) + Sn^4+(aq)}, the standard reduction potentials are E∘(FeX3+/FeX2+)=+0.77 VE^\circ(\ce{Fe^3+/Fe^2+}) = +0.77\text{ V} and E∘(SnX4+/SnX2+)=+0.15 VE^\circ(\ce{Sn^4+/Sn^2+}) = +0.15\text{ V}. Determine Ecell∘E^\circ_{\text{cell}} and calculate ΔG∘\Delta G^\circ for the reaction (F=96,485 C/molF = 96{,}485\text{ C/mol}).

Answer

Ecell∘=+0.62 VE^\circ_{\text{cell}} = +0.62\text{ V}, ΔG∘=−1.2×102 kJ/mol\Delta G^\circ = -1.2 \times 10^2\text{ kJ/mol}. Standard cell potential is Ecell∘=+0.77 V−(+0.15 V)=+0.62 VE^\circ_{\text{cell}} = +0.77\text{ V} - (+0.15\text{ V}) = +0.62\text{ V} (unscaled by 2). With n=2n = 2 electrons transferred, ΔG∘=−nFEcell∘=−(2)(96,485 C/mol)(0.62 V)≈−1.20×105 J/mol=−120 kJ/mol\Delta G^\circ = -nFE^\circ_{\text{cell}} = -(2)(96{,}485\text{ C/mol})(0.62\text{ V}) \approx -1.20 \times 10^5\text{ J/mol} = -120\text{ kJ/mol}.

03

Consider an acidic dichromate cell: CrX2OX7X2−+14 HX++6 eX−→2 CrX3++7 HX2O\ce{Cr2O7^2- + 14H+ + 6e- -> 2Cr^3+ + 7H2O} (E∘=+1.33 VE^\circ = +1.33\text{ V}) paired with CuX2++2 eX−→Cu\ce{Cu^2+ + 2e- -> Cu} (E∘=+0.34 VE^\circ = +0.34\text{ V}). Write the balanced cell reaction and determine Ecell∘E^\circ_{\text{cell}}.

Answer

Reaction: CrX2OX7X2−+14 HX++3 Cu→2 CrX3++3 CuX2++7 HX2O\ce{Cr2O7^2- + 14H+ + 3Cu -> 2Cr^3+ + 3Cu^2+ + 7H2O}; Ecell∘=+0.99 VE^\circ_{\text{cell}} = +0.99\text{ V}. The copper half-reaction is multiplied by 3 to balance electrons, but neither potential is scaled. Ecell∘=Ecathode∘−Eanode∘=+1.33 V−(+0.34 V)=+0.99 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +1.33\text{ V} - (+0.34\text{ V}) = +0.99\text{ V}.