Resources
A standard electrochemical cell based on the alkaline battery chemistry operates via the overall redox reaction: . The standard reduction potentials are for the zinc half-reaction in alkaline medium and for the manganese dioxide half-reaction . Calculate the standard cell potential for this battery under standard conditions.
Answer and steps
Final answer
Steps
Identify the oxidation and reduction half-reactions
To find the standard cell potential (), determine which half-reaction takes place at the cathode (reduction) and which takes place at the anode (oxidation).
Look at the change in oxidation states in the overall reaction:
- Anode (Oxidation): Zinc () increases in oxidation state from to in , losing electrons: The given standard reduction potential for this zinc couple is:
- Cathode (Reduction): Manganese () decreases in oxidation state from in to in , gaining electrons: The standard reduction potential for this manganese couple is:
Calculate the standard cell potential ()
Using the standard reduction potentials of the cathode and anode:
Substitute the values:
Common Pitfalls to Avoid
- Stoichiometry does not change : Even though the manganese half-reaction is multiplied by to balance the two electrons transferred, standard electrode potential is an intensive property and must not be multiplied by stoichiometric coefficients.
- Double-counting negative signs: When applying the formula , both potentials must be entered as standard reduction potentials. Do not manually flip the sign of before subtracting it.
Typical errors
01 The student multiplies the standard reduction potential of the cathode half-reaction by 2 to balance electrons before calculating E°_cell, incorrectly treating standard reduction potential as an extensive property.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You multiplied the reduction potential by to match the stoichiometry. Standard reduction potential () is an intensive property and represents potential energy per unit charge (), so it does not change when a half-reaction is multiplied by a coefficient.
- Step 2
- Step 3Correct
You applied the correct cell potential equation and handled the signs properly, but your final result was affected by substituting the multiplied cathode potential.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified which half-reaction occurs at the cathode and which occurs at the anode.
You used the correct relationship .
You correctly handled the double negative when subtracting .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou scaled the standard electrode potential by the stoichiometric factor of 2.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing standard electrode potential (, an intensive property) with Gibbs free energy change (, an extensive property) when balancing redox electrons.
REASONING PATH
Your ACEpath teacher’s suggested approach- Intensive vs. Extensive
is an intensive property (volts = joules per coulomb) and never changes when multiplying half-reactions by stoichiometric integers.
Leave standard reduction potentials unchanged regardless of the multiplier used to balance electrons.
- Cell Potential Formula
, where both values are standard reduction potentials.
Directly substitute tabulated standard reduction potentials without scaling or pre-flipping signs.
CORRECTED PATH
ACEpath Teacher's DemonstrationSet without scaling by stoichiometric coefficients.
Keep .
Calculate .
02 The student reverses the sign of the anode potential to represent the oxidation potential and then subtracts it in E°_cell = E°(cathode) - E°(anode), effectively subtracting the positive oxidation potential and resulting in -1.13 V.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You subtracted your reversed oxidation potential () instead of adding it. If you use the subtraction formula , both values must remain standard reduction potentials. Alternatively, if you flip the sign to find , you must add them: .
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified which species is reduced at the cathode and which is oxidized at the anode.
You extracted the correct numerical values from the given standard reduction potentials.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConflating two distinct cell potential formulas: versus . Flipping the sign of the anode potential and then subtracting it applies the negative sign twice, incorrectly yielding a negative cell potential for a galvanic cell.
REASONING PATH
Your ACEpath teacher’s suggested approach- Choose One Consistent Formula
Use either (subtract standard reduction potentials directly) OR (add reduction and oxidation potentials).
Never flip the sign of the anode reduction potential and then subtract it.
- Galvanic Cell Sanity Check
Operating commercial batteries are galvanic cells, which must have a positive standard cell potential ().
If your calculated for a spontaneous battery is negative, immediately check for sign errors.
CORRECTED PATH
ACEpath Teacher's DemonstrationIdentify standard reduction potentials: and .
Apply the reduction-potential formula: .
Simplify: .
03 The student reverses the roles of cathode and anode, computing E°_cell = E°(anode) - E°(cathode) to get -1.43 V.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You subtracted the reduction potential of the cathode from that of the anode. Because is oxidized from to at the anode and is reduced from to at the cathode, the correct relationship is .
- Step 2Correct
Your arithmetic was accurate for the expression you set up, but the value is negative because the order of subtraction in Step 1 was inverted.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified the two given standard reduction potentials from the half-reactions.
You performed the arithmetic subtraction correctly according to your written formula.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou set up the formula as anode minus cathode instead of cathode minus anode.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou associated the leftmost reactant (Zn) with the leading term of the subtraction rather than determining which species undergoes reduction (cathode) versus oxidation (anode). Galvanic cells operate spontaneously with a positive standard potential ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Identify Cathode vs. Anode
Reduction occurs at the cathode (gain of electrons, decrease in oxidation state); oxidation occurs at the anode (loss of electrons, increase in oxidation state).
Assign oxidation states to determine which species is reduced, and place that half-cell potential first: .
- Standard Cell Potential Formula
When both values are tabulated standard reduction potentials, .
Always subtract the anode's standard reduction potential from the cathode's standard reduction potential.
- Sanity Check for Batteries
A functioning galvanic or voltaic cell must have a positive standard cell potential ().
If your battery calculation yields a negative voltage, re-check whether you swapped the cathode and anode.
CORRECTED PATH
ACEpath Teacher's DemonstrationDetermine which substance is reduced: in , manganese goes from to , so is reduced at the cathode ().
Determine which substance is oxidized: zinc goes from to , so is oxidized at the anode ().
Apply the standard cell potential equation: .
Evaluate the arithmetic: .
Lock it in
When you multiply a balanced half-reaction by an integer to equalize transferred electrons, what happens to its standard reduction potential ?
It remains unchanged. Standard potential is an intensive property (energy per unit charge, ), so it does not scale with stoichiometry.
Similar question
A galvanic cell uses the reaction . Given and , calculate .
Answer
. Identify cathode (reduction of ) and anode (oxidation of ). Do not multiply by 3. Compute .
For the reaction , the standard reduction potentials are and . Determine and calculate for the reaction ().
Answer
, . Standard cell potential is (unscaled by 2). With electrons transferred, .
Consider an acidic dichromate cell: () paired with (). Write the balanced cell reaction and determine .
Answer
Reaction: ; . The copper half-reaction is multiplied by 3 to balance electrons, but neither potential is scaled. .