Resources

In an analytical chemistry laboratory, a potentiometric titration is monitored at 298 K298\text{ K} using an indicator platinum electrode and a saturated calomel reference electrode (SCE, Eref=+0.244 VE_{\text{ref}} = +0.244\text{ V}). A 25.00 mL25.00\text{ mL} aliquot of 0.0800 M Fe2+0.0800\text{ M }\text{Fe}^{2+} is titrated with 0.0800 M Ce4+0.0800\text{ M }\text{Ce}^{4+} according to Fe2+(aq)+Ce4+(aq)→Fe3+(aq)+Ce3+(aq)\text{Fe}^{2+}(aq) + \text{Ce}^{4+}(aq) \rightarrow \text{Fe}^{3+}(aq) + \text{Ce}^{3+}(aq). Given E∘=+0.771 VE^\circ = +0.771\text{ V} for Fe3+/Fe2+\text{Fe}^{3+}/\text{Fe}^{2+}, calculate the potential of the indicator electrode versus standard hydrogen electrode (EindE_{\text{ind}}) and the measured overall cell potential (Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}) after the addition of exactly 12.50 mL12.50\text{ mL} of the titrant (the midpoint of the titration before the equivalence point).

Answer and steps

Final answer

Eind=+0.771 VE_{\text{ind}} = +0.771\text{ V}; Ecell=+0.527 VE_{\text{cell}} = +0.527\text{ V}

Steps

01

Calculate the moles of reactants and products

The titration reaction is: FeX2+(aq)+CeX4+(aq)→FeX3+(aq)+CeX3+(aq)\ce{Fe^{2+}(aq) + Ce^{4+}(aq) -> Fe^{3+}(aq) + Ce^{3+}(aq)}

First, calculate the initial moles of FeX2+\ce{Fe^{2+}} present in the titration flask: nFeX2+, initial=25.00 mL×0.0800 mmol/mL=2.000 mmoln_{\ce{Fe^{2+}},\text{ initial}} = 25.00\text{ mL} \times 0.0800\text{ mmol/mL} = 2.000\text{ mmol}

Next, calculate the moles of CeX4+\ce{Ce^{4+}} added: nCeX4+, added=12.50 mL×0.0800 mmol/mL=1.000 mmoln_{\ce{Ce^{4+}},\text{ added}} = 12.50\text{ mL} \times 0.0800\text{ mmol/mL} = 1.000\text{ mmol}

Because the stoichiometric ratio is 1:11:1, the added CeX4+\ce{Ce^{4+}} acts as the limiting reactant:

  • Moles of FeX2+\ce{Fe^{2+}} remaining: nFeX2+=2.000 mmol−1.000 mmol=1.000 mmoln_{\ce{Fe^{2+}}} = 2.000\text{ mmol} - 1.000\text{ mmol} = 1.000\text{ mmol}
  • Moles of FeX3+\ce{Fe^{3+}} produced: nFeX3+=1.000 mmoln_{\ce{Fe^{3+}}} = 1.000\text{ mmol}

Since both ions share the same solution volume: [FeX3+]=[FeX2+][\ce{Fe^{3+}}] = [\ce{Fe^{2+}}]


02

Determine the indicator electrode potential (EindE_{\text{ind}})

Before the equivalence point, the potential of the platinum indicator electrode is determined by the unreacted analyte redox couple (FeX3+/FeX2+\ce{Fe^{3+}}/\ce{Fe^{2+}}): FeX3+(aq)+eX−⇌FeX2+(aq)\ce{Fe^{3+}(aq) + e^- <=> Fe^{2+}(aq)}

Applying the Nernst equation at 298 K298\text{ K} (n=1n = 1): Eind=EFeX3+/FeX2+∘−0.0592 V1log⁡10([FeX2+][FeX3+])E_{\text{ind}} = E^\circ_{\ce{Fe^{3+}}/\ce{Fe^{2+}}} - \frac{0.0592\text{ V}}{1} \log_{10}\left(\frac{[\ce{Fe^{2+}}]}{[\ce{Fe^{3+}}]}\right)

Substitute [FeX2+]=[FeX3+][\ce{Fe^{2+}}] = [\ce{Fe^{3+}}]: Eind=+0.771 V−0.0592 V⋅log⁡10(1)E_{\text{ind}} = +0.771\text{ V} - 0.0592\text{ V} \cdot \log_{10}(1) Eind=+0.771 V−0 V=+0.771 VE_{\text{ind}} = +0.771\text{ V} - 0\text{ V} = +0.771\text{ V}


03

Calculate the overall cell potential (EcellE_{\text{cell}})

The measured cell potential relative to the saturated calomel reference electrode (SCE\text{SCE}) is: Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}

Substitute the values: Ecell=+0.771 V−(+0.244 V)=+0.527 VE_{\text{cell}} = +0.771\text{ V} - (+0.244\text{ V}) = +0.527\text{ V}

Common Pitfall: At the midpoint (half-equivalence point) of a symmetrical redox titration, the ratio of oxidized to reduced form of the analyte is exactly 11, making the logarithmic term vanish regardless of total solution volume. Be careful to subtract, not add, the reference potential when finding the net cell potential measured across the two electrodes.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student adds the reference electrode potential instead of subtracting it when calculating the cell potential.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Veq=25.00 mL×0.0800 M0.0800 M=25.00 mL  ⟹  At V=12.50 mL, [FeX2+]=[FeX3+]V_{\text{eq}} = \frac{25.00\text{ mL} \times 0.0800\text{ M}}{0.0800\text{ M}} = 25.00\text{ mL} \implies \text{At } V = 12.50\text{ mL},\ [\ce{Fe^{2+}}] = [\ce{Fe^{3+}}]

  2. Step 2

    Eind=E∘−0.0592 V⋅log⁡([FeX2+]/[FeX3+])=0.771 V−0.0592 V⋅log⁡(1)=0.771 VE_{\text{ind}} = E^\circ - 0.0592\text{ V} \cdot \log([\ce{Fe^{2+}}]/[\ce{Fe^{3+} }]) = 0.771\text{ V} - 0.0592\text{ V} \cdot \log(1) = 0.771\text{ V}

  3. Step 3

    Ecell=Eind+Eref  ⟹  Ecell=0.771 V+0.244 V=1.015 VE_{\text{cell}} = E_{\text{ind}} + E_{\text{ref}} \implies E_{\text{cell}} = 0.771\text{ V} + 0.244\text{ V} = 1.015\text{ V}

    Correct

    Ecell=Eind−Eref=0.771 V−0.244 V=+0.527 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = 0.771\text{ V} - 0.244\text{ V} = +0.527\text{ V}

    You added the reference electrode potential to EindE_{\text{ind}} rather than subtracting it. In a standard potentiometric cell where the indicator acts as the working electrode against a reference electrode, the measured voltage is Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You calculated the titration midpoint volume accurately.

You identified that the reaction ratio of reduced to oxidized species is 1:11:1 at the half-equivalence point.

You applied the Nernst equation correctly to find the potential of the indicator electrode versus SHE.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reference Electrode Potential Sign Error

You initially wrote the correct subtraction 0.771 V−0.244 V0.771\text{ V} - 0.244\text{ V}, but crossed it out and changed the operation to addition.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing cell potential convention with standard additive combinations, forgetting that the reference electrode potential serves as the baseline to subtract (Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Potentiometric Cell Voltage Formula
  • Ecell=Eindicator−EreferenceE_{\text{cell}} = E_{\text{indicator}} - E_{\text{reference}}

  • Always subtract the reference electrode potential (ErefE_{\text{ref}}) from the indicator electrode potential (EindE_{\text{ind}}) when measuring potential difference against a reference electrode.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Take the indicator potential: Eind=+0.771 VE_{\text{ind}} = +0.771\text{ V}.

  2. Substitute into the potentiometric cell equation: Ecell=Eind−Eref=+0.771 V−(+0.244 V)E_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.771\text{ V} - (+0.244\text{ V}).

  3. Perform the subtraction: Ecell=+0.527 VE_{\text{cell}} = +0.527\text{ V}.

Final answer

Eind=+0.771 VE_{\text{ind}} = +0.771\text{ V}; Ecell=+0.527 VE_{\text{cell}} = +0.527\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the convention for potentiometric cells: voltmeter reading is Ecell=Eworking−EreferenceE_{\text{cell}} = E_{\text{working}} - E_{\text{reference}}.

  • Practice converting potentials measured against reference electrodes (like SCE or Ag/AgCl\ce{Ag/AgCl}) to the SHE scale and vice versa.

OverviewACEpath Teacher's Diagnosis

02 The student confuses the midpoint before the equivalence point with the equivalence point, mistakenly assuming all Fe²⁺ is completely reacted to leave zero remaining.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    mmol Fe2+ initial=25.00 mL×0.0800 M=2.00 mmol  ⟹  mmol Ce4+ added=12.50 mL×0.0800 M=1.00 mmol\text{mmol Fe}^{2+}\text{ initial} = 25.00\text{ mL} \times 0.0800\text{ M} = 2.00\text{ mmol} \implies \text{mmol Ce}^{4+}\text{ added} = 12.50\text{ mL} \times 0.0800\text{ M} = 1.00\text{ mmol}

  2. Step 2

    Assuming FeX2+ is completely reacted at this point, [FeX2+]=0 M\text{Assuming } \ce{Fe^{2+}} \text{ is completely reacted at this point, } [\ce{Fe^{2+}}] = 0\text{ M}

    Correct

    nFeX2+=2.000 mmol−1.000 mmol=1.000 mmol,nFeX3+=1.000 mmol  ⟹  [FeX2+]=[FeX3+]n_{\ce{Fe^{2+}}} = 2.000\text{ mmol} - 1.000\text{ mmol} = 1.000\text{ mmol}, \quad n_{\ce{Fe^{3+}}} = 1.000\text{ mmol} \implies [\ce{Fe^{2+}}] = [\ce{Fe^{3+}}]

    Because CeX4+\ce{Ce^{4+}} is the limiting reagent before the equivalence point, adding 1.00 mmol1.00\text{ mmol} of CeX4+\ce{Ce^{4+}} consumes only 1.00 mmol1.00\text{ mmol} of FeX2+\ce{Fe^{2+}}, leaving 1.00 mmol1.00\text{ mmol} of unreacted FeX2+\ce{Fe^{2+}} along with 1.00 mmol1.00\text{ mmol} of newly formed FeX3+\ce{Fe^{3+}}.

  3. Step 3

    Eind cannot be calculated using log⁡(0), so assuming Eind=0 VE_{\text{ind}} \text{ cannot be calculated using } \log(0), \text{ so assuming } E_{\text{ind}} = 0\text{ V}

    Correct

    E_{\text{ind}} = E^\circ_{\ce{Fe^{3+}/Fe^{2+}}} - 0.0592\text{ V} \log_{10}\left(\frac{[\ce{Fe^{2+}}]}{[\ce{Fe^{3+}}]} ight) = +0.771\text{ V} - 0.0592\text{ V} \log_{10}(1) = +0.771\text{ V}

    This step was thrown off by the zero concentration assumed in Step 2. With equal concentrations of FeX2+\ce{Fe^{2+}} and FeX3+\ce{Fe^{3+}} at the midpoint, the reaction quotient ratio is 11, making log⁡10(1)=0\log_{10}(1) = 0 and Eind=E∘E_{\text{ind}} = E^\circ.

  4. Step 4

    Ecell=Eind−Eref=0 V−0.244 V=−0.244 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = 0\text{ V} - 0.244\text{ V} = -0.244\text{ V}

    Correct

    Ecell=Eind−Eref=+0.771 V−(+0.244 V)=+0.527 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.771\text{ V} - (+0.244\text{ V}) = +0.527\text{ V}

    You correctly used the relationship Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}, but your final number was affected by the incorrect value of EindE_{\text{ind}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You calculated the initial moles of analyte and added moles of titrant accurately.

You correctly recalled the formula connecting cell potential, indicator electrode potential, and reference electrode potential (Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Stoichiometry error / Equivalence point confusion

none

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the half-equivalence point (midpoint) with the equivalence point, assuming that the analyte FeX2+\ce{Fe^{2+}} was completely consumed rather than recognizing that titrant CeX4+\ce{Ce^{4+}} is the limiting reactant and only half of the initial FeX2+\ce{Fe^{2+}} has reacted.

REASONING PATH
Your ACEpath teacher’s suggested approach
Identify the Limiting Reactant
  • Before the equivalence point in a titration, the added titrant is the limiting reactant, leaving unreacted analyte in the titration mixture.

  • Set up an ICF (Initial-Change-Final) mole table to subtract the consumed analyte moles from the initial analyte moles.

Midpoint / Half-Equivalence Principle
  • At exactly half the volume required for equivalence, exactly half of the analyte has been converted into product, so [extoxidizedform]=[extreducedform][ ext{oxidized form}] = [ ext{reduced form}].

  • Notice that [Red][Ox]=1\frac{[\text{Red}]}{[\text{Ox}]} = 1, which makes the logarithmic term in the Nernst equation zero, yielding Eind=E∘E_{\text{ind}} = E^\circ.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up an ICF table for FeX2++CeX4+→FeX3++CeX3+\ce{Fe^{2+} + Ce^{4+} -> Fe^{3+} + Ce^{3+}}: Initial FeX2+=2.000 mmol\ce{Fe^{2+}} = 2.000\text{ mmol}, added CeX4+=1.000 mmol\ce{Ce^{4+}} = 1.000\text{ mmol}.

  2. Since CeX4+\ce{Ce^{4+}} is limiting, consumed FeX2+=1.000 mmol\ce{Fe^{2+}} = 1.000\text{ mmol}, leaving nFeX2+=1.000 mmoln_{\ce{Fe^{2+}}} = 1.000\text{ mmol} and forming nFeX3+=1.000 mmoln_{\ce{Fe^{3+}}} = 1.000\text{ mmol}.

  3. In the same solution volume, [FeX2+]=[FeX3+][\ce{Fe^{2+}}] = [\ce{Fe^{3+}}], so the ratio [FeX2+]/[FeX3+]=1[\ce{Fe^{2+}}]/[\ce{Fe^{3+}}] = 1.

  4. Apply the Nernst equation: Eind=E∘−0.0592 V1log⁡10(1)=+0.771 V−0 V=+0.771 VE_{\text{ind}} = E^\circ - \frac{0.0592\text{ V}}{1} \log_{10}(1) = +0.771\text{ V} - 0\text{ V} = +0.771\text{ V}.

  5. Calculate the measured cell potential: Ecell=Eind−Eref=+0.771 V−(+0.244 V)=+0.527 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.771\text{ V} - (+0.244\text{ V}) = +0.527\text{ V}.

Final answer

Eind=+0.771 VE_{\text{ind}} = +0.771\text{ V}; Ecell=+0.527 VE_{\text{cell}} = +0.527\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice drawing a quick Initial-Change-Final (ICF) mole table before using the Nernst equation in titration problems.

  • Remember that at the midpoint before equivalence, [extanalyte]=[extproduct][ ext{analyte}] = [ ext{product}], so Eind=E∘E_{\text{ind}} = E^\circ for a 1:11:1 redox couple.

OverviewACEpath Teacher's Diagnosis

03 The student inverts the ratio of reduced and oxidized species in the Nernst log term and evaluates log(2) instead of recognizing the concentrations are equal.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    mmol Fe3+ formed=12.50 mL×0.0800 M=1.00 mmol  ⟹  mmol Fe2+ remaining=2.00 mmol−1.00 mmol=1.00 mmol\text{mmol Fe}^{3+}\text{ formed} = 12.50\text{ mL} \times 0.0800\text{ M} = 1.00\text{ mmol} \implies \text{mmol Fe}^{2+}\text{ remaining} = 2.00\text{ mmol} - 1.00\text{ mmol} = 1.00\text{ mmol}

  2. Step 2

    Eind=E∘−0.0592 V×log⁡([FeX3+]/[FeX2+ dynasties]) with ratio taken as 2/1  ⟹  Eind=0.771 V−0.0592 V×log⁡(2)=0.771 V−0.018 V=0.753 VE_{\text{ind}} = E^\circ - 0.0592\text{ V} \times \log([\ce{Fe^{3+}}]/[\ce{Fe^{2+} dynasties}])\text{ with ratio taken as }2/1 \implies E_{\text{ind}} = 0.771\text{ V} - 0.0592\text{ V} \times \log(2) = 0.771\text{ V} - 0.018\text{ V} = 0.753\text{ V}

    Correct

    Eind=E∘−0.0592 V×log⁡([FeX2+][FeX3+])=+0.771 V−0.0592 V×log⁡(1)=+0.771 VE_{\text{ind}} = E^\circ - 0.0592\text{ V} \times \log\left(\frac{[\ce{Fe^{2+}}]}{[\ce{Fe^{3+}}]}\right) = +0.771\text{ V} - 0.0592\text{ V} \times \log(1) = +0.771\text{ V}

    Because 1.00 mmol1.00\text{ mmol} of FeX3+\ce{Fe^{3+}} and 1.00 mmol1.00\text{ mmol} of FeX2+\ce{Fe^{2+}} share the same solution volume, their concentration ratio is 1.001.00=1\frac{1.00}{1.00} = 1. Since log⁡(1)=0\log(1) = 0, the logarithmic term vanishes entirely at the midpoint, giving Eind=E∘=+0.771 VE_{\text{ind}} = E^\circ = +0.771\text{ V}.

  3. Step 3

    Ecell=Eind−Eref=0.753 V−0.244 V=0.509 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = 0.753\text{ V} - 0.244\text{ V} = 0.509\text{ V}

    Correct

    Ecell=Eind−Eref=+0.771 V−0.244 V=+0.527 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.771\text{ V} - 0.244\text{ V} = +0.527\text{ V}

    You applied the correct cell potential formula Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}}, but your numerical result was affected by the earlier calculation of EindE_{\text{ind}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You accurately found the initial moles of analyte and titrant to determine remaining and formed quantities.

You recognized that the cell potential is measured as the indicator potential minus the reference potential.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Nernst ratio misidentification at titration midpoint

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You used an arbitrary ratio of 2/1 in the Nernst term instead of using the ratio of the calculated equimolar quantities (1.00 mmol / 1.00 mmol = 1) at the half-equivalence point.

REASONING PATH
Your ACEpath teacher’s suggested approach
Evaluate the concentration ratio at the half-equivalence point
  • At the half-equivalence point of a 1:1 redox titration, exactly half of the initial analyte has reacted, so [reduced form]=[oxidized form][\text{reduced form}] = [\text{oxidized form}].

  • Always substitute the ratio of your calculated molar quantities into the Nernst quotient; when the amounts are equal, log⁡(1)=0\log(1) = 0 and E=E∘E = E^\circ.

Check the Nernst quotient sign convention
  • For a reduction half-reaction Ox+neX−⇌Red\ce{Ox + }n\ce{e^- <=> Red}, the Nernst equation is E=E∘−0.0592nlog⁡([Red][Ox])E = E^\circ - \frac{0.0592}{n}\log\left(\frac{[\text{Red}]}{[\text{Ox}]}\right) or E=E∘+0.0592nlog⁡([Ox][Red])E = E^\circ + \frac{0.0592}{n}\log\left(\frac{[\text{Ox}]}{[\text{Red}]}\right).

  • Match the sign in front of the log term with the correct placement of reduced and oxidized species.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the Nernst equation with the ratio of equimolar species: Eind=E∘−0.0592 V×log⁡(1.00 mmol1.00 mmol)=+0.771 V−0 V=+0.771 VE_{\text{ind}} = E^\circ - 0.0592\text{ V} \times \log\left(\frac{1.00\text{ mmol}}{1.00\text{ mmol}}\right) = +0.771\text{ V} - 0\text{ V} = +0.771\text{ V}.

  2. Compute the overall cell potential against the saturated calomel electrode: Ecell=Eind−Eref=+0.771 V−0.244 V=+0.527 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.771\text{ V} - 0.244\text{ V} = +0.527\text{ V}.

Final answer

Eind=+0.771 VE_{\text{ind}} = +0.771\text{ V}; Ecell=+0.527 VE_{\text{cell}} = +0.527\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice identifying the half-equivalence point where [Ox]=[Red][\text{Ox}] = [\text{Red}] so that E=E∘E = E^\circ immediately without evaluating non-zero logarithms.

  • Double-check your Nernst equation quotient format to ensure the sign and species ratio match standard reduction conventions.

Lock it in

Similar question

01

A potentiometric titration is monitored using an indicator electrode and an Ag/AgCl\ce{Ag/AgCl} reference electrode (Eref=+0.197 VE_{\text{ref}} = +0.197\text{ V}). If the indicator electrode potential versus SHE is determined to be Eind=+0.650 VE_{\text{ind}} = +0.650\text{ V}, calculate the measured cell potential EcellE_{\text{cell}}.

Answer

Ecell=+0.453 VE_{\text{cell}} = +0.453\text{ V}. Key step: Ecell=Eind−Eref=+0.650 V−(+0.197 V)=+0.453 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.650\text{ V} - (+0.197\text{ V}) = +0.453\text{ V}.

02

In a potentiometric titration of 20.00 mL20.00\text{ mL} of 0.0500 M SnX2+0.0500\text{ M } \ce{Sn^{2+}} with 0.1000 M CeX4+0.1000\text{ M } \ce{Ce^{4+}} monitored with SCE (Eref=+0.244 VE_{\text{ref}} = +0.244\text{ V}), calculate EindE_{\text{ind}} and EcellE_{\text{cell}} at the half-equivalence point. (Given: ESnX4+/SnX2+∘=+0.150 VE^\circ_{\ce{Sn^{4+}/Sn^{2+}}} = +0.150\text{ V}).

Answer

Eind=+0.150 VE_{\text{ind}} = +0.150\text{ V}, Ecell=−0.094 VE_{\text{cell}} = -0.094\text{ V}. Key steps: At the half-equivalence point, [SnX4+]=[SnX2+][\ce{Sn^{4+}}] = [\ce{Sn^{2+}}], so Eind=E∘=+0.150 VE_{\text{ind}} = E^\circ = +0.150\text{ V}. Then Ecell=Eind−Eref=+0.150 V−(+0.244 V)=−0.094 VE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} = +0.150\text{ V} - (+0.244\text{ V}) = -0.094\text{ V}.

03

A student measures an overall cell potential of Ecell=+0.312 VE_{\text{cell}} = +0.312\text{ V} using a saturated calomel electrode (SCE, E=+0.244 VE = +0.244\text{ V} vs SHE) connected as the reference electrode. What is the actual potential of the indicator electrode versus the standard hydrogen electrode (EindE_{\text{ind}})?

Answer

Eind=+0.556 VE_{\text{ind}} = +0.556\text{ V}. Key steps: Rearrange Ecell=Eind−ErefE_{\text{cell}} = E_{\text{ind}} - E_{\text{ref}} to give Eind=Ecell+Eref=+0.312 V+(+0.244 V)=+0.556 VE_{\text{ind}} = E_{\text{cell}} + E_{\text{ref}} = +0.312\text{ V} + (+0.244\text{ V}) = +0.556\text{ V}.

Loading workspace…