Resources

An analytical chemistry student standardizes an unknown aqueous silver nitrate (AgNO3\text{AgNO}_3) solution by titrating an aliquot containing dissolved chloride using the Mohr method with potassium chromate (K2CrO4\text{K}_2\text{CrO}_4) as an indicator. The titration endpoint occurs when reddish-brown silver chromate (Ag2CrO4\text{Ag}_2\text{CrO}_4) first begins to precipitate. The indicator concentration at the equivalence point is [CrO42−]=2.50×10−3 M[\text{CrO}_4^{2-}] = 2.50 \times 10^{-3}\text{ M}. At the titration temperature (25∘C25^\circ\text{C}), Ksp(AgCl)=1.80×10−10K_{sp}(\text{AgCl}) = 1.80 \times 10^{-10} and Ksp(Ag2CrO4)=1.20×10−12K_{sp}(\text{Ag}_2\text{CrO}_4) = 1.20 \times 10^{-12}. (a) Calculate the silver ion concentration [Ag+][\text{Ag}^+] required to initiate precipitation of Ag2CrO4\text{Ag}_2\text{CrO}_4. (b) Calculate the remaining concentration of unprecipitated chloride ion [Cl−][\text{Cl}^-] at this exact indicator transition point. (c) Compare this remaining [Cl−][\text{Cl}^-] to the theoretical equivalence point [Cl−]eq=1.34×10−5 M[\text{Cl}^-]_{\text{eq}} = 1.34 \times 10^{-5}\text{ M} and evaluate whether the titration endpoint slightly precedes or slightly exceeds the true equivalence point.

Answer and steps

Final answer

(a) [Ag+]=2.19×10−5 M[\text{Ag}^+] = 2.19 \times 10^{-5}\text{ M}; (b) [Cl−]=8.22×10−6 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M}; (c) Because [Cl−]=8.22×10−6 M<1.34×10−5 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M} < 1.34 \times 10^{-5}\text{ M}, [Ag+][\text{Ag}^+] at the endpoint exceeds [Ag+]eq[\text{Ag}^+]_{\text{eq}}, meaning the Mohr indicator endpoint occurs slightly after (exceeds) the true stoichiometric equivalence point (positive titration error).

Steps

Part (a): Silver Ion Concentration at the Onset of Indicator Precipitation

Silver chromate (AgX2CrOX4\ce{Ag2CrO4}) dissolves in water according to the equilibrium:

AgX2CrOX4(s)⇌2 AgX+(aq)+CrOX4X2−(aq)\ce{Ag2CrO4(s) <=> 2 Ag+(aq) + CrO4^{2-}(aq)}

The solubility product expression is:

Ksp(AgX2CrOX4)=[AgX+]2[CrOX4X2−]K_{\text{sp}}(\ce{Ag2CrO4}) = [\ce{Ag+}]^2 [\ce{CrO4^{2-}}]

Precipitation of AgX2CrOX4\ce{Ag2CrO4} begins as soon as the ion product exceeds KspK_{\text{sp}}. Rearranging for the threshold silver ion concentration:

[AgX+]=Ksp(AgX2CrOX4)[CrOX4X2−][\ce{Ag+}] = \sqrt{\frac{K_{\text{sp}}(\ce{Ag2CrO4})}{[\ce{CrO4^{2-}}]}}

Substitute the given values:

[AgX+]=1.20×10−122.50×10−3=4.80×10−10≈2.19×10−5 M[\ce{Ag+}] = \sqrt{\frac{1.20 \times 10^{-12}}{2.50 \times 10^{-3}}} = \sqrt{4.80 \times 10^{-10}} \approx 2.19 \times 10^{-5}\text{ M}


Part (b): Remaining Chloride Ion Concentration at the Endpoint

Throughout the titration, solid AgCl\ce{AgCl} is present and remains in dynamic equilibrium with the solution:

AgCl(s)⇌AgX+(aq)+ClX−(aq),Ksp(AgCl)=[AgX+][ClX−]\ce{AgCl(s) <=> Ag+(aq) + Cl-(aq)}, \quad K_{\text{sp}}(\ce{AgCl}) = [\ce{Ag+}][\ce{Cl-}]

Using the [AgX+][\ce{Ag+}] calculated at the moment AgX2CrOX4\ce{Ag2CrO4} begins to precipitate:

[ClX−]=Ksp(AgCl)[AgX+]=1.80×10−102.1909×10−5 M≈8.22×10−6 M[\ce{Cl-}] = \frac{K_{\text{sp}}(\ce{AgCl})}{[\ce{Ag+}]} = \frac{1.80 \times 10^{-10}}{2.1909 \times 10^{-5}}\text{ M} \approx 8.22 \times 10^{-6}\text{ M}


Part (c): Comparison with the Equivalence Point and Endpoint Evaluation

  1. Compare Concentrations: At the true stoichiometric equivalence point, silver and chloride ions exist in a strict 1:11:1 ratio from dissolution: [AgX+]eq=[ClX−]eq=Ksp(AgCl)=1.80×10−10≈1.34×10−5 M[\ce{Ag+}]_{\text{eq}} = [\ce{Cl-}]_{\text{eq}} = \sqrt{K_{\text{sp}}(\ce{AgCl})} = \sqrt{1.80 \times 10^{-10}} \approx 1.34 \times 10^{-5}\text{ M} At the experimental indicator endpoint: [ClX−]end=8.22×10−6 M<[ClX−]eq=1.34×10−5 M[\ce{Cl-}]_{\text{end}} = 8.22 \times 10^{-6}\text{ M} < [\ce{Cl-}]_{\text{eq}} = 1.34 \times 10^{-5}\text{ M}
  2. Evaluate the Endpoint vs. Equivalence Point: Because [ClX−][\ce{Cl-}] has fallen below its equivalence-point value, additional AgX+\ce{Ag+} titrant has been added past equivalence to depress the chloride concentration. Correspondingly: [AgX+]end=2.19×10−5 M>[AgX+]eq=1.34×10−5 M[\ce{Ag+}]_{\text{end}} = 2.19 \times 10^{-5}\text{ M} > [\ce{Ag+}]_{\text{eq}} = 1.34 \times 10^{-5}\text{ M}

    Therefore, the indicator endpoint occurs slightly after (exceeds) the true equivalence point, introducing a small positive titration error (which is typically corrected in practice with an indicator blank).

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the silver ion concentration in the Ksp expression for Ag2CrO4, underestimating [Ag+] and incorrectly concluding the endpoint precedes equivalence.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Ksp=[Ag+][CrO42−]  ⟹  [Ag+]=1.20×10−122.50×10−3=4.80×10−10 MK_{sp} = [\text{Ag}^+][\text{CrO}_4^{2-}] \implies [\text{Ag}^+] = \frac{1.20 \times 10^{-12}}{2.50 \times 10^{-3}} = 4.80 \times 10^{-10}\text{ M}

    Correct

    Ksp(Ag2CrO4)=[Ag+]2[CrO42−]  ⟹  [Ag+]=1.20×10−122.50×10−3=2.19×10−5 MK_{sp}(\text{Ag}_2\text{CrO}_4) = [\text{Ag}^+]^2[\text{CrO}_4^{2-}] \implies [\text{Ag}^+] = \sqrt{\frac{1.20 \times 10^{-12}}{2.50 \times 10^{-3}}} = 2.19 \times 10^{-5}\text{ M}

    Because Ag2CrO4\text{Ag}_2\text{CrO}_4 dissociates into two Ag+\text{Ag}^+ ions and one CrO42−\text{CrO}_4^{2-} ion, its solubility product expression requires [extAg+][ ext{Ag}^+] to be squared: Ksp=[Ag+]2[CrO42−]K_{sp} = [\text{Ag}^+]^2[\text{CrO}_4^{2-}].

  2. Step 2

    Ksp(AgCl)=[Ag+][Cl−]  ⟹  [Cl−]=1.80×10−104.80×10−10=0.375 MK_{sp}(\text{AgCl}) = [\text{Ag}^+][\text{Cl}^-] \implies [\text{Cl}^-] = \frac{1.80 \times 10^{-10}}{4.80 \times 10^{-10}} = 0.375\text{ M}

    Correct

    [Cl−]=Ksp(AgCl)[Ag+]=1.80×10−102.19×10−5=8.22×10−6 M[\text{Cl}^-] = \frac{K_{sp}(\text{AgCl})}{[\text{Ag}^+]} = \frac{1.80 \times 10^{-10}}{2.19 \times 10^{-5}} = 8.22 \times 10^{-6}\text{ M}

    Your formula for Ksp(AgCl)K_{sp}(\text{AgCl}) is correct, but your calculated [extCl−][ ext{Cl}^-] was thrown off by substituting the incorrect [extAg+][ ext{Ag}^+] from part (a).

  3. Step 3

    [Cl−]=0.375 M>[Cl−]eq=1.34×10−5 M  ⟹  endpoint slightly precedes equivalence[\text{Cl}^-] = 0.375\text{ M} > [\text{Cl}^-]_{eq} = 1.34 \times 10^{-5}\text{ M} \implies \text{endpoint slightly precedes equivalence}

    Correct

    [Cl−]end=8.22×10−6 M<[Cl−]eq=1.34×10−5 M  ⟹  endpoint slightly exceeds equivalence[\text{Cl}^-]_{end} = 8.22 \times 10^{-6}\text{ M} < [\text{Cl}^-]_{eq} = 1.34 \times 10^{-5}\text{ M} \implies \text{endpoint slightly exceeds equivalence}

    With the correct value of [Cl−]=8.22×10−6 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M}, the remaining chloride concentration is lower than [Cl−]eq[\text{Cl}^-]_{eq}, which means excess Ag+\text{Ag}^+ titrant was added and the endpoint slightly exceeds the true equivalence point.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that precipitation begins when the ion product reaches KspK_{sp}.

You used the correct 1:11:1 stoichiometric KspK_{sp} expression for AgCl\text{AgCl}.

You understood the logic of comparing the remaining chloride concentration to [Cl−]eq[\text{Cl}^-]_{eq} to determine whether the endpoint precedes or exceeds equivalence.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing stoichiometric exponent in Ksp expression

You forgot to raise [Ag+][\text{Ag}^+] to the second power when writing the KspK_{sp} expression for silver chromate, Ag2CrO4\text{Ag}_2\text{CrO}_4.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking the stoichiometric coefficients from the dissociation equation AmBn(s)⇌mAn+(aq)+nBm−(aq)\text{A}_m\text{B}_n(s) \rightleftharpoons m\text{A}^{n+}(aq) + n\text{B}^{m-}(aq), where each ion concentration in the equilibrium expression must be raised to its stoichiometric coefficient.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dissociation Stoichiometry
  • For a salt MxXy(s)\text{M}_x\text{X}_y(s), the solubility product is Ksp=[My+]x[Xx−]yK_{sp} = [\text{M}^{y+}]^x [\text{X}^{x-}]^y.

  • Always write out the balanced dissociation equation first before writing the KspK_{sp} algebraic expression.

Plausibility Check of Concentrations
  • In an analytical precipitation titration, the concentration of unprecipitated analyte near equivalence is typically very small (10−4 M10^{-4}\text{ M} to 10−6 M10^{-6}\text{ M}).

  • A calculated remaining [Cl−][\text{Cl}^-] of 0.375 M0.375\text{ M} indicates an almost unprecipitated solution; seeing such a large concentration should prompt an immediate check of exponents in prior steps.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the balanced dissolution equilibrium: Ag2CrO4(s)⇌2Ag+(aq)+CrO42−(aq)\text{Ag}_2\text{CrO}_4(s) \rightleftharpoons 2\text{Ag}^+(aq) + \text{CrO}_4^{2-}(aq).

  2. Formulate Ksp=[Ag+]2[CrO42−]K_{sp} = [\text{Ag}^+]^2[\text{CrO}_4^{2-}], solve for [Ag+]=1.20×10−122.50×10−3=2.19×10−5 M[\text{Ag}^+] = \sqrt{\frac{1.20 \times 10^{-12}}{2.50 \times 10^{-3}}} = 2.19 \times 10^{-5}\text{ M}.

  3. Substitute into Ksp(AgCl)K_{sp}(\text{AgCl}): [Cl−]=1.80×10−102.19×10−5=8.22×10−6 M[\text{Cl}^-] = \frac{1.80 \times 10^{-10}}{2.19 \times 10^{-5}} = 8.22 \times 10^{-6}\text{ M}.

  4. Compare [Cl−]=8.22×10−6 M<1.34×10−5 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M} < 1.34 \times 10^{-5}\text{ M}; since [Cl−][\text{Cl}^-] is below equivalence, more titrant was added, so the endpoint slightly exceeds the true equivalence point.

Final answer

(a) [Ag+]=2.19×10−5 M[\text{Ag}^+] = 2.19 \times 10^{-5}\text{ M}; (b) [Cl−]=8.22×10−6 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M}; (c) The endpoint slightly exceeds the true equivalence point.

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice writing KspK_{sp} expressions for asymmetric salts such as Ag2CrO4\text{Ag}_2\text{CrO}_4, CaF2\text{CaF}_2, and Bi2S3\text{Bi}_2\text{S}_3 to ensure stoichiometric exponents are never missed.

  • Perform order-of-magnitude reality checks on intermediate concentrations in titration problems.

OverviewACEpath Teacher's Diagnosis

02 The student misinterprets a lower remaining chloride concentration as meaning the titration has not yet reached equivalence, concluding that the endpoint precedes the equivalence point.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Ksp(Ag2CrO4)=[Ag+]2[CrO42−]  ⟹  [Ag+]=1.20×10−122.50×10−3  ⟹  [Ag+]=2.19×10−5 MK_{sp}(\text{Ag}_2\text{CrO}_4) = [\text{Ag}^+]^2 [\text{CrO}_4^{2-}] \implies [\text{Ag}^+] = \sqrt{\frac{1.20 \times 10^{-12}}{2.50 \times 10^{-3}}} \implies [\text{Ag}^+] = 2.19 \times 10^{-5}\text{ M}

  2. Step 2

    Ksp(AgCl)=[Ag+][Cl−]  ⟹  [Cl−]=1.80×10−102.19×10−5  ⟹  [Cl−]=8.22×10−6 MK_{sp}(\text{AgCl}) = [\text{Ag}^+] [\text{Cl}^-] \implies [\text{Cl}^-] = \frac{1.80 \times 10^{-10}}{2.19 \times 10^{-5}} \implies [\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M}

  3. Step 3

    [Cl−]=8.22×10−6 M<1.34×10−5 M  ⟹  [\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M} < 1.34 \times 10^{-5}\text{ M} \implies Because the chloride concentration is below the equivalence value, the endpoint slightly precedes the equivalence point.

    Correct

    Because [Cl−]=8.22×10−6 M<1.34×10−5 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M} < 1.34 \times 10^{-5}\text{ M}, more Ag+\text{Ag}^+ has been added than required for stoichiometric equivalence, meaning [Ag+]=2.19×10−5 M>1.34×10−5 M[\text{Ag}^+] = 2.19 \times 10^{-5}\text{ M} > 1.34 \times 10^{-5}\text{ M}. Thus, the endpoint slightly exceeds (occurs after) the equivalence point.

    During a precipitation titration, the analyte concentration [Cl−][\text{Cl}^-] decreases as more Ag+\text{Ag}^+ titrant is delivered. Therefore, [Cl−]<[Cl−]eq[\text{Cl}^-] < [\text{Cl}^-]_{\text{eq}} indicates that titrant addition has progressed past the equivalence point, not stopped before it.

WHAT YOU DID WELL
Compliments from Your Teacher

You wrote the correct solubility product expression for Ag2CrO4\text{Ag}_2\text{CrO}_4, including the squared stoichiometry for silver.

You calculated the threshold [Ag+][\text{Ag}^+] and remaining [Cl−][\text{Cl}^-] with exact numerical accuracy.

You correctly compared the endpoint chloride concentration to the theoretical equivalence value.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Titration Direction Misinterpretation

You treated a concentration lower than equivalence as if the reaction had not progressed far enough, rather than recognizing that analyte concentration drops as titration proceeds.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing analyte consumption with titrant addition: in a direct titration, the concentration of the species in the flask decreases continuously. An analyte concentration below [analyte]eq[\text{analyte}]_{\text{eq}} corresponds to an over-titrated state (past equivalence), whereas a titrant concentration above [titrant]eq[\text{titrant}]_{\text{eq}} confirms that the endpoint exceeds equivalence.

REASONING PATH
Your ACEpath teacher’s suggested approach
Track the Analyte Trend
  • As titrant is added to precipitate analyte AA, [A][A] strictly decreases monotonically throughout the titration.

  • Check: If [A]end<[A]eq[A]_{\text{end}} < [A]_{\text{eq}}, the titration is past equivalence (exceeds). If [A]end>[A]eq[A]_{\text{end}} > [A]_{\text{eq}}, the titration has not yet reached equivalence (precedes).

Cross-Check with Titrant Concentration
  • At the equivalence point of a 1:11:1 precipitate, [Ag+]eq=[Cl−]eq[\text{Ag}^+]_{\text{eq}} = [\text{Cl}^-]_{\text{eq}}.

  • Compare [Ag+]end[\text{Ag}^+]_{\text{end}} to [Ag+]eq[\text{Ag}^+]_{\text{eq}}: since 2.19×10−5 M>1.34×10−5 M2.19 \times 10^{-5}\text{ M} > 1.34 \times 10^{-5}\text{ M}, excess titrant has been delivered, confirming the endpoint exceeds equivalence.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recognize that as AgNO3\text{AgNO}_3 is added to the chloride solution, [Cl−][\text{Cl}^-] drops continuously due to AgCl\text{AgCl} precipitation.

  2. Compare the endpoint value to equivalence: [Cl−]end=8.22×10−6 M<[Cl−]eq=1.34×10−5 M[\text{Cl}^-]_{\text{end}} = 8.22 \times 10^{-6}\text{ M} < [\text{Cl}^-]_{\text{eq}} = 1.34 \times 10^{-5}\text{ M}.

  3. Since [Cl−][\text{Cl}^-] has dropped below [Cl−]eq[\text{Cl}^-]_{\text{eq}}, extra Ag+\text{Ag}^+ beyond the stoichiometric amount has been added ([Ag+]end=2.19×10−5 M>[Ag+]eq=1.34×10−5 M[\text{Ag}^+]_{\text{end}} = 2.19 \times 10^{-5}\text{ M} > [\text{Ag}^+]_{\text{eq}} = 1.34 \times 10^{-5}\text{ M}).

  4. Conclude that the Mohr titration endpoint slightly exceeds (occurs after) the true equivalence point, representing a slight positive titration error.

Final answer

(a) [Ag+]=2.19×10−5 M[\text{Ag}^+] = 2.19 \times 10^{-5}\text{ M}; (b) [Cl−]=8.22×10−6 M[\text{Cl}^-] = 8.22 \times 10^{-6}\text{ M}; (c) Because [Cl−]<[Cl−]eq[\text{Cl}^-] < [\text{Cl}^-]_{\text{eq}}, more Ag+\text{Ag}^+ has been added than stoichiometrically required, so the endpoint slightly exceeds the equivalence point.

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice interpreting titration curves by identifying whether analyte or titrant is being monitored on the vertical axis.

  • Always cross-check endpoint errors using both reacting species: an analyte deficit ([analyte]<[analyte]eq[\text{analyte}] < [\text{analyte}]_{\text{eq}}) must coincide with a titrant surplus ([titrant]>[titrant]eq[\text{titrant}] > [\text{titrant}]_{\text{eq}}).

Lock it in

Similar question

01

Calculate the molar solubility ss of silver chromate (Ag2CrO4\text{Ag}_2\text{CrO}_4) in pure water at 25∘C25^\circ\text{C} given Ksp=1.20×10−12K_{sp} = 1.20 \times 10^{-12}.

Answer

s=6.69×10−5 Ms = 6.69 \times 10^{-5}\text{ M}. Key steps: Ksp=[Ag+]2[CrO42−]=(2s)2(s)=4s3K_{sp} = [\text{Ag}^+]^2[\text{CrO}_4^{2-}] = (2s)^2(s) = 4s^3. Thus, s=1.20×10−1243≈6.69×10−5 Ms = \sqrt[3]{\frac{1.20 \times 10^{-12}}{4}} \approx 6.69 \times 10^{-5}\text{ M}.

02

Solid lead(II) chloride dissolves as PbCl2(s)⇌Pb2+(aq)+2Cl−(aq)\text{PbCl}_2(s) \rightleftharpoons \text{Pb}^{2+}(aq) + 2\text{Cl}^-(aq) with Ksp=1.70×10−5K_{sp} = 1.70 \times 10^{-5}. If [extCl−]=0.0200 M[ ext{Cl}^-] = 0.0200\text{ M} in a solution, what minimum [extPb2+][ ext{Pb}^{2+}] is required to start precipitation of PbCl2\text{PbCl}_2?

Answer

[Pb2+]=4.25×10−2 M[\text{Pb}^{2+}] = 4.25 \times 10^{-2}\text{ M}. Key steps: Ksp=[Pb2+][Cl−]2K_{sp} = [\text{Pb}^{2+}][\text{Cl}^-]^2. Rearranging gives [Pb2+]=Ksp[Cl−]2=1.70×10−5(0.0200)2=4.25×10−2 M[\text{Pb}^{2+}] = \frac{K_{sp}}{[\text{Cl}^-]^2} = \frac{1.70 \times 10^{-5}}{(0.0200)^2} = 4.25 \times 10^{-2}\text{ M}.

03

A solution contains 0.050 M Cl−0.050\text{ M } \text{Cl}^- and 0.0010 M CrO42−0.0010\text{ M } \text{CrO}_4^{2-}. As AgNO3\text{AgNO}_3 is added gradually, determine: (1) which precipitate forms first (AgCl\text{AgCl} with Ksp=1.80×10−10K_{sp} = 1.80 \times 10^{-10} or Ag2CrO4\text{Ag}_2\text{CrO}_4 with Ksp=1.20×10−12K_{sp} = 1.20 \times 10^{-12}), and (2) the percentage of Cl−\text{Cl}^- remaining in solution when Ag2CrO4\text{Ag}_2\text{CrO}_4 just begins to precipitate.

Answer

(1) AgCl\text{AgCl} forms first; (2) 0.010%0.010\% of Cl−\text{Cl}^- remains. Key steps: [Ag+][\text{Ag}^+] for AgCl=1.80×10−100.050=3.6×10−9 M\text{AgCl} = \frac{1.80 \times 10^{-10}}{0.050} = 3.6 \times 10^{-9}\text{ M}. [Ag+][\text{Ag}^+] for Ag2CrO4=1.20×10−120.0010=3.46×10−5 M\text{Ag}_2\text{CrO}_4 = \sqrt{\frac{1.20 \times 10^{-12}}{0.0010}} = 3.46 \times 10^{-5}\text{ M}. Since 3.6×10−9 M<3.46×10−5 M3.6 \times 10^{-9}\text{ M} < 3.46 \times 10^{-5}\text{ M}, AgCl\text{AgCl} precipitates first. When Ag2CrO4\text{Ag}_2\text{CrO}_4 precipitates, [Cl−]=1.80×10−103.464×10−5=5.20×10−6 M[\text{Cl}^-] = \frac{1.80 \times 10^{-10}}{3.464 \times 10^{-5}} = 5.20 \times 10^{-6}\text{ M}. % remaining=5.20×10−60.050×100%≈0.010%\%\text{ remaining} = \frac{5.20 \times 10^{-6}}{0.050} \times 100\% \approx 0.010\%.