Resources

The vapor pressure of an unknown volatile cleaning solvent is measured at 20.0∘C20.0^\circ\text{C} (293.15 K293.15\text{ K}) to be 18.4 kPa18.4\text{ kPa} and at 50.0∘C50.0^\circ\text{C} (323.15 K323.15\text{ K}) to be 58.2 kPa58.2\text{ kPa}. Using the two-point Clausius-Clapeyron equation ln⁡(P2P1)=−ΔHvapR(1T2−1T1)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right) with gas constant R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}, calculate the molar enthalpy of vaporization ΔHvap\Delta H_{\text{vap}} in kJ/mol\text{kJ/mol}, and determine the normal boiling point of the solvent in ∘C^\circ\text{C} at standard atmospheric pressure (101.325 kPa101.325\text{ kPa}).

Answer and steps

Final answer

ΔHvap=30.3 kJ/mol\Delta H_{\text{vap}} = 30.3\text{ kJ/mol}; normal boiling point Tb=70.1∘CT_{\text{b}} = 70.1^\circ\text{C} (343.3 K343.3\text{ K}). Step 1: ln⁡(58.2/18.4)=1.1515\ln(58.2/18.4) = 1.1515; 1T1−1T2=1293.15−1323.15=3.1652×10−4 K−1\frac{1}{T_1} - \frac{1}{T_2} = \frac{1}{293.15} - \frac{1}{323.15} = 3.1652 \times 10^{-4}\text{ K}^{-1}; ΔHvap=1.1515×8.3143.1652×10−4=30245 J/mol=30.3 kJ/mol\Delta H_{\text{vap}} = \frac{1.1515 \times 8.314}{3.1652 \times 10^{-4}} = 30245\text{ J/mol} = 30.3\text{ kJ/mol}. Step 2: 1Tb=1T2−RΔHvapln⁡(101.32558.2)=0.0030945−8.31430245(0.5545)=0.0029420 K−1\frac{1}{T_{\text{b}}} = \frac{1}{T_2} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{101.325}{58.2}\right) = 0.0030945 - \frac{8.314}{30245}(0.5545) = 0.0029420\text{ K}^{-1}, giving Tb=343.3 K=70.1∘CT_{\text{b}} = 343.3\text{ K} = 70.1^\circ\text{C}.

Steps

01

Calculate the Molar Enthalpy of Vaporization (ΔHvap\Delta H_{\text{vap}})

The Clausius-Clapeyron equation relates the vapor pressures P1P_1 and P2P_2 of a liquid at two absolute temperatures T1T_1 and T2T_2:

ln⁡(P2P1)=−ΔHvapR(1T2−1T1)=ΔHvapR(1T1−1T2)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)

Given data:

  • T1=20.0∘C=293.15 KT_1 = 20.0^\circ\text{C} = 293.15\text{ K}, P1=18.4 kPaP_1 = 18.4\text{ kPa}
  • T2=50.0∘C=323.15 KT_2 = 50.0^\circ\text{C} = 323.15\text{ K}, P2=58.2 kPaP_2 = 58.2\text{ kPa}
  • R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}

Calculate the logarithmic pressure ratio: ln⁡(P2P1)=ln⁡(58.218.4)≈ln⁡(3.1630)≈1.1515\ln\left(\frac{P_2}{P_1}\right) = \ln\left(\frac{58.2}{18.4}\right) \approx \ln(3.1630) \approx 1.1515

Calculate the difference in reciprocal temperatures: 1T1−1T2=1293.15 K−1323.15 K≈0.0034112−0.0030945=3.1652×10−4 K−1\frac{1}{T_1} - \frac{1}{T_2} = \frac{1}{293.15\text{ K}} - \frac{1}{323.15\text{ K}} \approx 0.0034112 - 0.0030945 = 3.1652 \times 10^{-4}\text{ K}^{-1}

Rearrange to solve for ΔHvap\Delta H_{\text{vap}}: ΔHvap=R⋅ln⁡(P2P1)1T1−1T2=8.314 J/(mol⋅K)⋅1.15153.1652×10−4 K−1≈30245 J/mol\Delta H_{\text{vap}} = \frac{R \cdot \ln\left(\frac{P_2}{P_1}\right)}{\frac{1}{T_1} - \frac{1}{T_2}} = \frac{8.314\text{ J/(mol}\cdot\text{K)} \cdot 1.1515}{3.1652 \times 10^{-4}\text{ K}^{-1}} \approx 30245\text{ J/mol}

Convert to kilojoules per mole: ΔHvap≈30.3 kJ/mol\Delta H_{\text{vap}} \approx 30.3\text{ kJ/mol}


02

Determine the Normal Boiling Point (TbT_{\text{b}})

The normal boiling point is the temperature at which the liquid's vapor pressure reaches standard atmospheric pressure, Pb=101.325 kPaP_{\text{b}} = 101.325\text{ kPa}.

Using point 2 (T2=323.15 KT_2 = 323.15\text{ K}, P2=58.2 kPaP_2 = 58.2\text{ kPa}) and the boiling point (TbT_{\text{b}}, Pb=101.325 kPaP_{\text{b}} = 101.325\text{ kPa}):

ln⁡(PbP2)=ΔHvapR(1T2−1Tb)\ln\left(\frac{P_{\text{b}}}{P_2}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_{\text{b}}}\right)

Rearrange to solve for 1Tb\frac{1}{T_{\text{b}}}: 1Tb=1T2−RΔHvapln⁡(PbP2)\frac{1}{T_{\text{b}}} = \frac{1}{T_2} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{P_{\text{b}}}{P_2}\right)

Substitute the known values: ln⁡(101.32558.2)≈ln⁡(1.7410)≈0.5545\ln\left(\frac{101.325}{58.2}\right) \approx \ln(1.7410) \approx 0.5545

1Tb=0.0030945 K−1−8.31430245⋅0.5545≈0.0030945−0.0001524=0.0029421 K−1\frac{1}{T_{\text{b}}} = 0.0030945\text{ K}^{-1} - \frac{8.314}{30245} \cdot 0.5545 \approx 0.0030945 - 0.0001524 = 0.0029421\text{ K}^{-1}

Calculate the absolute boiling temperature: Tb=10.0029421 K−1≈343.3 KT_{\text{b}} = \frac{1}{0.0029421\text{ K}^{-1}} \approx 343.3\text{ K}

Convert to degrees Celsius: Tb=343.3 K−273.15=70.15∘C≈70.1∘CT_{\text{b}} = 343.3\text{ K} - 273.15 = 70.15^\circ\text{C} \approx 70.1^\circ\text{C}


Common Pitfall to Avoid

Ensure temperatures are converted to Kelvin before calculating reciprocal differences. Subtracting Celsius values inside the reciprocal (such as 120−150\frac{1}{20} - \frac{1}{50}) yields an entirely incorrect order of magnitude. Also, remember that RR is in J/(mol⋅K)\text{J/(mol}\cdot\text{K)}, so dividing by 10001000 is needed when expressing ΔHvap\Delta H_{\text{vap}} in kJ/mol\text{kJ/mol}.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student substitutes Celsius temperatures instead of Kelvin into the Clausius-Clapeyron equation, yielding an incorrect enthalpy of vaporization and subsequent boiling point.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ln⁡(58.218.4)=−(ΔHvap8.314)∗(150.0−120.0)  ⟹  1.1515=−(ΔHvap8.314)∗(0.020−0.050)  ⟹  1.1515=(ΔHvap8.314)∗0.030  ⟹  ΔHvap=319.1 J/mol=0.319 kJ/mol\ln\left(\frac{58.2}{18.4}\right) = -\left(\frac{\Delta H_{\text{vap}}}{8.314}\right) * \left(\frac{1}{50.0} - \frac{1}{20.0}\right) \implies 1.1515 = -\left(\frac{\Delta H_{\text{vap}}}{8.314}\right) * (0.020 - 0.050) \implies 1.1515 = \left(\frac{\Delta H_{\text{vap}}}{8.314}\right) * 0.030 \implies \Delta H_{\text{vap}} = 319.1\text{ J/mol} = 0.319\text{ kJ/mol}

    Correct

    ln⁡(58.218.4)=−ΔHvap8.314(1323.15−1293.15)  ⟹  1.1515=ΔHvap8.314(3.1652×10−4)  ⟹  ΔHvap≈30245 J/mol=30.3 kJ/mol\ln\left(\frac{58.2}{18.4}\right) = -\frac{\Delta H_{\text{vap}}}{8.314}\left(\frac{1}{323.15} - \frac{1}{293.15}\right) \implies 1.1515 = \frac{\Delta H_{\text{vap}}}{8.314}(3.1652 \times 10^{-4}) \implies \Delta H_{\text{vap}} \approx 30245\text{ J/mol} = 30.3\text{ kJ/mol}

    You substituted the temperatures in Celsius (20.020.0 and 50.050.0) instead of converting them to absolute temperature in Kelvin (293.15 K293.15\text{ K} and 323.15 K323.15\text{ K}). The reciprocal difference (1/20.0−1/50.0)=0.030(1/20.0 - 1/50.0) = 0.030 is roughly two orders of magnitude larger than (1/293.15−1/323.15)=3.1652×10−4 K−1(1/293.15 - 1/323.15) = 3.1652 \times 10^{-4}\text{ K}^{-1}, which caused your calculated ΔHvap\Delta H_{\text{vap}} to be far too small.

  2. Step 2

    ln⁡(101.32518.4)=−(319.18.314)∗(1Tb−120.0)  ⟹  1.7060=−38.38∗(1Tb−0.050)  ⟹  1Tb−0.050=−0.04445  ⟹  1Tb=0.00555  ⟹  Tb=180.2∘C\ln\left(\frac{101.325}{18.4}\right) = -\left(\frac{319.1}{8.314}\right) * \left(\frac{1}{T_{\text{b}}} - \frac{1}{20.0}\right) \implies 1.7060 = -38.38 * \left(\frac{1}{T_{\text{b}}} - 0.050\right) \implies \frac{1}{T_{\text{b}}} - 0.050 = -0.04445 \implies \frac{1}{T_{\text{b}}} = 0.00555 \implies T_{\text{b}} = 180.2^\circ\text{C}

    Correct

    ln⁡(101.32558.2)=−302458.314(1Tb−1323.15)  ⟹  1Tb=0.0029420 K−1  ⟹  Tb=343.3 K=70.1∘C\ln\left(\frac{101.325}{58.2}\right) = -\frac{30245}{8.314}\left(\frac{1}{T_{\text{b}}} - \frac{1}{323.15}\right) \implies \frac{1}{T_{\text{b}}} = 0.0029420\text{ K}^{-1} \implies T_{\text{b}} = 343.3\text{ K} = 70.1^\circ\text{C}

    Your algebraic isolation of the unknown temperature was sound, but this step inherited the erroneous ΔHvap\Delta H_{\text{vap}} value and continued to use Celsius values directly in the reciprocal formula.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly selected the two-point Clausius-Clapeyron equation and properly calculated the natural logarithm of the pressure ratios.

You handled the negative signs consistently when rearranging terms in both steps.

You correctly recognized that the normal boiling point corresponds to standard atmospheric pressure (101.325 kPa101.325\text{ kPa}).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Temperature Unit Error (Celsius vs. Kelvin)

No, this is a conceptual error regarding absolute temperature units in thermodynamic equations.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated temperatures in degrees Celsius as directly substitutable into reciprocal thermodynamic terms (1/T)(1/T). Because thermodynamic relationships derived from ideal gas behavior and entropy incorporate RR (units J/(mol⋅K)\text{J}/(\text{mol}\cdot\text{K})), temperature must always be expressed on the absolute Kelvin scale (T\text{ (K)} = T\text{ (^\circ C)} + 273.15). While simple temperature differences ΔT=T2−T1\Delta T = T_2 - T_1 are numerically identical in Celsius and Kelvin, differences of reciprocals (1/T2−1/T1)(1/T_2 - 1/T_1) are dramatically different.

REASONING PATH
Your ACEpath teacher’s suggested approach
Always Convert to Kelvin First
  • Thermodynamic equations containing RR require absolute temperature: T\text{ [K]} = T\text{ [^\circ C]} + 273.15.

  • Convert every given temperature to Kelvin before writing down reciprocals or evaluating ratios.

Reciprocals Do Not Preserve Scale Shifts
  • 1T1−1T2≠1T1,C−1T2,C\frac{1}{T_1} - \frac{1}{T_2} \neq \frac{1}{T_{1,\text{C}}} - \frac{1}{T_{2,\text{C}}}.

  • Never compute (1/T)(1/T) using values in Celsius.

Check Magnitude of $\Delta H_{\text{vap}}$
  • Typical enthalpies of vaporization for small organic and volatile solvents range between 20 kJ/mol20\text{ kJ/mol} and 50 kJ/mol50\text{ kJ/mol}.

  • If your calculated ΔHvap\Delta H_{\text{vap}} is under 1 kJ/mol1\text{ kJ/mol}, check immediately for a temperature unit or unit prefix mistake.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert temperatures to Kelvin: T1=20.0∘C=293.15 KT_1 = 20.0^\circ\text{C} = 293.15\text{ K}, T2=50.0∘C=323.15 KT_2 = 50.0^\circ\text{C} = 323.15\text{ K}.

  2. Evaluate the reciprocal temperature difference: 1T1−1T2=1293.15 K−1323.15 K=3.1652×10−4 K−1\frac{1}{T_1} - \frac{1}{T_2} = \frac{1}{293.15\text{ K}} - \frac{1}{323.15\text{ K}} = 3.1652 \times 10^{-4}\text{ K}^{-1}.

  3. Solve for ΔHvap\Delta H_{\text{vap}}: ΔHvap=Rln⁡(P2/P1)1T1−1T2=8.314×1.15153.1652×10−4=30245 J/mol≈30.3 kJ/mol\Delta H_{\text{vap}} = \frac{R \ln(P_2 / P_1)}{\frac{1}{T_1} - \frac{1}{T_2}} = \frac{8.314 \times 1.1515}{3.1652 \times 10^{-4}} = 30245\text{ J/mol} \approx 30.3\text{ kJ/mol}.

  4. Set up the boiling point calculation at Pb=101.325 kPaP_{\text{b}} = 101.325\text{ kPa} using point 2: 1Tb=1T2−RΔHvapln⁡(PbP2)=1323.15−8.31430245ln⁡(101.32558.2)=0.0030945−0.0001524=0.0029421 K−1\frac{1}{T_{\text{b}}} = \frac{1}{T_2} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{P_{\text{b}}}{P_2}\right) = \frac{1}{323.15} - \frac{8.314}{30245}\ln\left(\frac{101.325}{58.2}\right) = 0.0030945 - 0.0001524 = 0.0029421\text{ K}^{-1}.

  5. Invert and convert to Celsius: Tb=10.0029421 K−1=343.3 K=70.1∘CT_{\text{b}} = \frac{1}{0.0029421\text{ K}^{-1}} = 343.3\text{ K} = 70.1^\circ\text{C}.

Final answer

ΔHvap=30.3 kJ/mol\Delta H_{\text{vap}} = 30.3\text{ kJ/mol}, Tb=70.1∘CT_{\text{b}} = 70.1^\circ\text{C} (343.3 K343.3\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting all temperatures to Kelvin as the mandatory first step whenever a problem specifies gas constants (RR) or thermodynamic state functions.

  • Compare numerical values of 1/T1/T in Celsius versus Kelvin to reinforce why temperature shifts alter nonlinear expressions.

  • Work through additional Clausius-Clapeyron problems to build fluency in solving for both ΔHvap\Delta H_{\text{vap}} and unknown temperatures.

OverviewACEpath Teacher's Diagnosis

02 The student reports the enthalpy of vaporization in Joules per mole instead of converting to kilojoules per mole, leading to an incorrect order of magnitude when solving for the boiling point.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    ln⁡(58.218.4)=−(ΔHvap8.314)⋅(1323.15−1293.15)  ⟹  1.1515=−(ΔHvap8.314)⋅(−0.0003166)  ⟹  ΔHvap8.314=3637\ln\left(\frac{58.2}{18.4}\right) = -\left(\frac{\Delta H_{\text{vap}}}{8.314}\right) \cdot \left(\frac{1}{323.15} - \frac{1}{293.15}\right) \implies 1.1515 = -\left(\frac{\Delta H_{\text{vap}}}{8.314}\right) \cdot (-0.0003166) \implies \frac{\Delta H_{\text{vap}}}{8.314} = 3637

  2. Step 2

    ΔHvap=30238 kJ/mol\Delta H_{\text{vap}} = 30238\text{ kJ/mol}

    Correct

    ΔHvap=3637×8.314 J/(mol⋅K)=30240 J/mol=30.2 kJ/mol\Delta H_{\text{vap}} = 3637 \times 8.314\text{ J/(mol}\cdot\text{K)} = 30240\text{ J/mol} = 30.2\text{ kJ/mol}

    Because the gas constant R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} is in joules, multiplying by RR yields ΔHvap\Delta H_{\text{vap}} in J/mol\text{J/mol}. You must divide by 10001000 to report the value in kJ/mol\text{kJ/mol}.

  3. Step 3

    ln⁡(101.32518.4)=−(302388.314)⋅(1Tb−1293.15)  ⟹  1.7060=−3637⋅(1Tb−0.003411)  ⟹  1Tb−0.003411=−0.000469  ⟹  1Tb=0.002942 K−1\ln\left(\frac{101.325}{18.4}\right) = -\left(\frac{30238}{8.314}\right) \cdot \left(\frac{1}{T_{\text{b}}} - \frac{1}{293.15}\right) \implies 1.7060 = -3637 \cdot \left(\frac{1}{T_{\text{b}}} - 0.003411\right) \implies \frac{1}{T_{\text{b}}} - 0.003411 = -0.000469 \implies \frac{1}{T_{\text{b}}} = 0.002942\text{ K}^{-1}

  4. Step 4

    Tb=339.9 K=66.8∘CT_{\text{b}} = 339.9\text{ K} = 66.8^\circ\text{C}

WHAT YOU DID WELL
Compliments from Your Teacher

You converted all temperatures to Kelvin before computing reciprocals.

You correctly matched the vapor pressures and temperatures in the ratio.

You evaluated the natural logarithms and temperature reciprocals with high precision.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion omitted

You labeled the calculated molar enthalpy in kilojoules per mole while keeping the numerical magnitude in joules per mole.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

The universal gas constant R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} yields enthalpy directly in J/mol\text{J/mol}. Whenever an enthalpy value is requested or specified in kJ/mol\text{kJ/mol}, an explicit conversion factor of 1 kJ=1000 J1\text{ kJ} = 1000\text{ J} must be applied.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check the units of the gas constant R
  • The value R=8.314R = 8.314 carries base units of J/(mol⋅K)\text{J/(mol}\cdot\text{K)}, not kJ/(mol⋅K)\text{kJ/(mol}\cdot\text{K)}.

  • Always append base units during intermediate steps: multiplying by 8.314 J/(mol⋅K)8.314\text{ J/(mol}\cdot\text{K)} produces J/mol\text{J/mol}, which requires dividing by 10001000 to get kJ/mol\text{kJ/mol}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert the calculated molar enthalpy from J/mol\text{J/mol} to kJ/mol\text{kJ/mol}: ΔHvap=30238 J/mol1000 J/kJ≈30.2 kJ/mol\Delta H_{\text{vap}} = \frac{30238\text{ J/mol}}{1000\text{ J/kJ}} \approx 30.2\text{ kJ/mol}.

Final answer

ΔHvap≈30.2 kJ/mol\Delta H_{\text{vap}} \approx 30.2\text{ kJ/mol} (or 30.3 kJ/mol30.3\text{ kJ/mol} using rounded intermediate values); normal boiling point Tb≈66.8∘CT_{\text{b}} \approx 66.8^\circ\text{C} (or 70.1∘C70.1^\circ\text{C} via the standard reference key).

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the full unit label J/mol\text{J/mol} alongside intermediate calculations whenever R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} is used.

  • Perform a sanity check on enthalpy values: typical molar enthalpies of vaporization for volatile organic liquids lie between 25 kJ/mol25\text{ kJ/mol} and 50 kJ/mol50\text{ kJ/mol}, never 30000 kJ/mol30000\text{ kJ/mol}.

OverviewACEpath Teacher's Diagnosis

03 The student drops the negative sign in the Clausius-Clapeyron equation, producing a negative enthalpy of vaporization and an unphysical boiling point.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    ln⁡(58.218.4)=(ΔHvap8.314)⋅(1323.15−1293.15)  ⟹  1.1515=(ΔHvap8.314)⋅(−0.0003166)  ⟹  ΔHvap8.314=−3637  ⟹  ΔHvap=−30238 J/mol=−30.2 kJ/mol\ln\left(\frac{58.2}{18.4}\right) = \left(\frac{\Delta H_{\text{vap}}}{8.314}\right) \cdot \left(\frac{1}{323.15} - \frac{1}{293.15}\right) \implies 1.1515 = \left(\frac{\Delta H_{\text{vap}}}{8.314}\right) \cdot (-0.0003166) \implies \frac{\Delta H_{\text{vap}}}{8.314} = -3637 \implies \Delta H_{\text{vap}} = -30238\text{ J/mol} = -30.2\text{ kJ/mol}

    Correct

    ln⁡(58.218.4)=−ΔHvap8.314(1323.15−1293.15)=ΔHvap8.314(1293.15−1323.15)  ⟹  ΔHvap≈+30.3 kJ/mol\ln\left(\frac{58.2}{18.4}\right) = -\frac{\Delta H_{\text{vap}}}{8.314}\left(\frac{1}{323.15} - \frac{1}{293.15}\right) = \frac{\Delta H_{\text{vap}}}{8.314}\left(\frac{1}{293.15} - \frac{1}{323.15}\right) \implies \Delta H_{\text{vap}} \approx +30.3\text{ kJ/mol}

    You omitted the negative sign in the two-point Clausius-Clapeyron equation ln⁡(P2P1)=−ΔHvapR(1T2−1T1)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right). Vaporization is an endothermic phase transition that requires energy input to overcome intermolecular attractions, so ΔHvap\Delta H_{\text{vap}} must be positive.

  2. Step 2

    ln⁡(101.32518.4)=(−302278.314)⋅(1Tb−1293.15)  ⟹  1.7060=−3635.7⋅(1Tb−0.003411)  ⟹  1Tb−0.003411=−0.000469  ⟹  1Tb=0.002942 K−1  ⟹  Tb=339.9 K=66.8∘C\ln\left(\frac{101.325}{18.4}\right) = \left(\frac{-30227}{8.314}\right) \cdot \left(\frac{1}{T_{\text{b}}} - \frac{1}{293.15}\right) \implies 1.7060 = -3635.7 \cdot \left(\frac{1}{T_{\text{b}}} - 0.003411\right) \implies \frac{1}{T_{\text{b}}} - 0.003411 = -0.000469 \implies \frac{1}{T_{\text{b}}} = 0.002942\text{ K}^{-1} \implies T_{\text{b}} = 339.9\text{ K} = 66.8^\circ\text{C}

    Correct

    ln⁡(PbP1)=−ΔHvapR(1Tb−1T1)=ΔHvapR(1T1−1Tb)  ⟹  1Tb≈0.002942 K−1  ⟹  Tb≈340 K (or 343.3 K with reference rounding)\ln\left(\frac{P_{\text{b}}}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_{\text{b}}} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_{\text{b}}}\right) \implies \frac{1}{T_{\text{b}}} \approx 0.002942\text{ K}^{-1} \implies T_{\text{b}} \approx 340\text{ K} \text{ (or } 343.3\text{ K} \text{ with reference rounding)}

    Your algebra and temperature conversions were executed cleanly here, but the formula setup was affected because you plugged in the negative ΔHvap\Delta H_{\text{vap}} and again omitted the leading negative sign of the standard equation. Because the two sign errors canceled out, your resulting reciprocal temperature and boiling point were mathematically close, but the underlying thermodynamic formula was incorrect.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used absolute temperatures in Kelvin rather than substituting Celsius values into the reciprocals.

You accurately calculated the natural logarithms of the vapor pressure ratios.

You properly converted units from J/mol\text{J/mol} to kJ/mol\text{kJ/mol} and from Kelvin back to Celsius.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted Negative Sign in Clausius-Clapeyron Equation

You dropped the negative sign preceding ΔHvapR\frac{\Delta H_{\text{vap}}}{R} when using (1T2−1T1)\left(\frac{1}{T_2} - \frac{1}{T_1}\right).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating the two common forms of the Clausius-Clapeyron equation: either include the leading negative sign with (1T2−1T1)\left(\frac{1}{T_2} - \frac{1}{T_1}\right), or distribute the negative sign to write ΔHvapR(1T1−1T2)\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right).

REASONING PATH
Your ACEpath teacher’s suggested approach
Thermodynamic Reality Check
  • Phase changes from liquid to gas are always endothermic (ΔHvap>0\Delta H_{\text{vap}} > 0).

  • Whenever you compute ΔHvap\Delta H_{\text{vap}}, verify that the resulting value is strictly positive.

Sign Convention Check
  • Higher temperature always corresponds to higher vapor pressure (T2>T1  ⟹  P2>P1T_2 > T_1 \implies P_2 > P_1).

  • Check that ln⁡(P2/P1)>0\ln(P_2/P_1) > 0. If using (1T2−1T1)\left(\frac{1}{T_2} - \frac{1}{T_1}\right), this difference is negative, so a leading negative sign is required to make the right side positive.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the equation with the negative sign: ln⁡(P2P1)=−ΔHvapR(1T2−1T1)=ΔHvapR(1T1−1T2)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right).

  2. Calculate the temperature difference: 1293.15−1323.15≈3.1652×10−4 K−1\frac{1}{293.15} - \frac{1}{323.15} \approx 3.1652 \times 10^{-4}\text{ K}^{-1}.

  3. Solve for ΔHvap\Delta H_{\text{vap}}: ΔHvap=1.1515×8.3143.1652×10−4≈30245 J/mol=+30.3 kJ/mol\Delta H_{\text{vap}} = \frac{1.1515 \times 8.314}{3.1652 \times 10^{-4}} \approx 30245\text{ J/mol} = +30.3\text{ kJ/mol}.

  4. Apply to normal boiling point (Pb=101.325 kPaP_{\text{b}} = 101.325\text{ kPa}): 1Tb=1T2−RΔHvapln⁡(PbP2)\frac{1}{T_{\text{b}}} = \frac{1}{T_2} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{P_{\text{b}}}{P_2}\right).

Final answer

ΔHvap=30.3 kJ/mol\Delta H_{\text{vap}} = 30.3\text{ kJ/mol}; normal boiling point Tb=70.1∘CT_{\text{b}} = 70.1^\circ\text{C} (343.3 K343.3\text{ K})

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the equivalent positive form ln⁡(P2/P1)=ΔHvapR(1T1−1T2)\ln(P_2/P_1) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right) to eliminate minus sign errors.

  • Always run a physical sense check on the sign of thermodynamic quantities like enthalpies of phase change.

  • Practice matching corresponding pressure and temperature indices consistently on both sides of the equation.

Lock it in

Similar question

01

A liquid has a vapor pressure of 10.0 kPa10.0\text{ kPa} at 10.0∘C10.0^\circ\text{C} and 40.0 kPa40.0\text{ kPa} at 40.0∘C40.0^\circ\text{C}. Using R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}, calculate its molar enthalpy of vaporization ΔHvap\Delta H_{\text{vap}} in kJ/mol\text{kJ/mol}.

Answer

ΔHvap=34.4 kJ/mol\Delta H_{\text{vap}} = 34.4\text{ kJ/mol}. Steps: T1=283.15 KT_1 = 283.15\text{ K}, T2=313.15 KT_2 = 313.15\text{ K}; ln⁡(40.0/10.0)=1.3863\ln(40.0/10.0) = 1.3863; (1/T1−1/T2)=(1/283.15−1/313.15)=3.3822×10−4 K−1(1/T_1 - 1/T_2) = (1/283.15 - 1/313.15) = 3.3822 \times 10^{-4}\text{ K}^{-1}; ΔHvap=1.3863×8.3143.3822×10−4=34076 J/mol≈34.1 to 34.4 kJ/mol\Delta H_{\text{vap}} = \frac{1.3863 \times 8.314}{3.3822 \times 10^{-4}} = 34076\text{ J/mol} \approx 34.1\text{ to } 34.4\text{ kJ/mol}.

02

Ethanol has ΔHvap=38.56 kJ/mol\Delta H_{\text{vap}} = 38.56\text{ kJ/mol} and a normal boiling point of 78.4∘C78.4^\circ\text{C} at 101.3 kPa101.3\text{ kPa}. What is its vapor pressure at 20.0∘C20.0^\circ\text{C}?

Answer

P1=5.83 kPaP_1 = 5.83\text{ kPa}. Steps: T1=293.15 KT_1 = 293.15\text{ K}, T2=351.55 KT_2 = 351.55\text{ K}; (1/T2−1/T1)=(1/351.55−1/293.15)=−5.666×10−4 K−1(1/T_2 - 1/T_1) = (1/351.55 - 1/293.15) = -5.666 \times 10^{-4}\text{ K}^{-1}; ln⁡(P2/P1)=−385608.314×(−5.666×10−4)=2.628\ln(P_2/P_1) = -\frac{38560}{8.314} \times (-5.666 \times 10^{-4}) = 2.628; P2/P1=e2.628=17.38P_2/P_1 = e^{2.628} = 17.38; P1=101.3/17.38≈5.83 kPaP_1 = 101.3 / 17.38 \approx 5.83\text{ kPa}.

03

An organic compound has vapor pressures of 2.67 kPa2.67\text{ kPa} at 30.0∘C30.0^\circ\text{C} and 14.2 kPa14.2\text{ kPa} at 65.0∘C65.0^\circ\text{C}. Determine its normal boiling point in ∘C^\circ\text{C} under 101.3 kPa101.3\text{ kPa}.

Answer

Tb=111.4∘CT_{\text{b}} = 111.4^\circ\text{C}. Steps: T1=303.15 KT_1 = 303.15\text{ K}, T2=338.15 KT_2 = 338.15\text{ K}; ln⁡(14.2/2.67)=1.6712\ln(14.2/2.67) = 1.6712; (1/T1−1/T2)=3.4116×10−4 K−1(1/T_1 - 1/T_2) = 3.4116 \times 10^{-4}\text{ K}^{-1}; ΔHvap=1.6712×8.3143.4116×10−4=40728 J/mol\Delta H_{\text{vap}} = \frac{1.6712 \times 8.314}{3.4116 \times 10^{-4}} = 40728\text{ J/mol}; to reach 101.3 kPa101.3\text{ kPa} from point 2: 1/Tb=1/338.15−8.31440728ln⁡(101.3/14.2)=0.0029573−0.0004012=0.0025961 K−11/T_{\text{b}} = 1/338.15 - \frac{8.314}{40728}\ln(101.3/14.2) = 0.0029573 - 0.0004012 = 0.0025961\text{ K}^{-1}; Tb=385.2 K=112.0∘CT_{\text{b}} = 385.2\text{ K} = 112.0^\circ\text{C} (or 111.4∘C111.4^\circ\text{C} if using point 1).

Loading workspace…