Resources

A chemistry student measures the mass of a zinc pellet to be 12.38 g12.38\text{ g} and its volume by displacement to be 1.78 mL1.78\text{ mL}. The accepted literature density of zinc is 7.14 g/cm37.14\text{ g/cm}^3. In calculating percent error, the student mistakenly swaps the values in the numerator, writing Accepted−ExperimentalAccepted×100%\frac{\text{Accepted} - \text{Experimental}}{\text{Accepted}} \times 100\% instead of the standard convention Experimental−AcceptedAccepted×100%\frac{\text{Experimental} - \text{Accepted}}{\text{Accepted}} \times 100\%. Calculate both the true conventional percent error and the student's inverted-sign result, explaining the physical consequence of the negative sign.

Answer and steps

Final answer

True percent error: −2.5%-2.5\% (indicating an experimental underestimate); Inverted student result: +2.5%+2.5\%

Steps

01

Calculate the Experimental Density

Density is defined as mass per unit volume: Density=MassVolume\text{Density} = \frac{\text{Mass}}{\text{Volume}}

Since 1 mL=1 cm31\text{ mL} = 1\text{ cm}^3, the volume is 1.78 cm31.78\text{ cm}^3: Experimental Density=12.38 g1.78 cm3≈6.955 g/cm3\text{Experimental Density} = \frac{12.38\text{ g}}{1.78\text{ cm}^3} \approx 6.955\text{ g/cm}^3

Rounding to three significant figures gives 6.96 g/cm36.96\text{ g/cm}^3.


02

Compute the True Conventional Percent Error

The standard scientific convention for percent error includes directional information: Percent Error=Experimental Value−Accepted ValueAccepted Value×100%\text{Percent Error} = \frac{\text{Experimental Value} - \text{Accepted Value}}{\text{Accepted Value}} \times 100\%

Substitute the experimental and accepted literature values: Percent Error=6.955 g/cm3−7.14 g/cm37.14 g/cm3×100%\text{Percent Error} = \frac{6.955\text{ g/cm}^3 - 7.14\text{ g/cm}^3}{7.14\text{ g/cm}^3} \times 100\% Percent Error=−0.1857.14×100%≈−2.5%\text{Percent Error} = \frac{-0.185}{7.14} \times 100\% \approx -2.5\%


03

Compute the Student's Inverted Result

Using the student's inverted formula: Student’s Result=Accepted Value−Experimental ValueAccepted Value×100%\text{Student's Result} = \frac{\text{Accepted Value} - \text{Experimental Value}}{\text{Accepted Value}} \times 100\% Student’s Result=7.14 g/cm3−6.955 g/cm37.14 g/cm3×100%=+0.1857.14×100%≈+2.5%\text{Student's Result} = \frac{7.14\text{ g/cm}^3 - 6.955\text{ g/cm}^3}{7.14\text{ g/cm}^3} \times 100\% = \frac{+0.185}{7.14} \times 100\% \approx +2.5\%


04

Physical Meaning of the Sign

  • Conventional Sign: A negative sign (−2.5%-2.5\%) directly reveals that the experimental result falls below the true literature value (an underestimate). Conversely, a positive result would signify an overestimate.
  • Pitfall of Inversion: Swapping the numerator terms reverses the sign, mistakenly presenting an underestimate as a positive deviation. While some introductory contexts take the absolute value, maintaining the true sign Experimental−AcceptedAccepted\frac{\text{Experimental} - \text{Accepted}}{\text{Accepted}} is critical for diagnosing systematic errors (such as air bubbles inflating the volume reading, which artificially lowers density).

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student divides by the experimental value instead of the accepted literature value in the denominator of both formulas.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Density=12.38 g/1.78 mL=6.955 g/cm3\text{Density} = 12.38\text{ g} / 1.78\text{ mL} = 6.955\text{ g/cm}^3

  2. Step 2

    Conventional error=(6.955−7.146.955)×100%=−2.66%\text{Conventional error} = \left(\frac{6.955 - 7.14}{6.955}\right) \times 100\% = -2.66\%

    Correct

    Percent Error=(6.955−7.147.14)×100%≈−2.5%\text{Percent Error} = \left(\frac{6.955 - 7.14}{7.14}\right) \times 100\% \approx -2.5\%

    You placed the experimental value (6.955 g/cm36.955\text{ g/cm}^3) in the denominator. Percent error expresses deviation relative to the accepted literature benchmark, so the denominator must be the accepted value (7.14 g/cm37.14\text{ g/cm}^3).

  3. Step 3

    The negative sign shows experimental density is below the accepted value.

  4. Step 4

    Student error=(7.14−6.9556.955)×100%=+2.66%\text{Student error} = \left(\frac{7.14 - 6.955}{6.955}\right) \times 100\% = +2.66\%

    Correct

    Student’s Result=(7.14−6.9557.14)×100%≈+2.5%\text{Student's Result} = \left(\frac{7.14 - 6.955}{7.14}\right) \times 100\% \approx +2.5\%

    You used the experimental density in the denominator again instead of dividing by the accepted value (7.14 g/cm37.14\text{ g/cm}^3).

  5. Step 5

    In the inverted formula, a negative sign indicates an overestimate above accepted.

WHAT YOU DID WELL
Compliments from Your Teacher

You accurately computed the experimental density from mass and displacement volume.

You correctly identified the conceptual difference in sign meaning between the standard and inverted percent error conventions.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Wrong denominator in percent error

You divided by the experimental density (6.955 g/cm36.955\text{ g/cm}^3) rather than the accepted literature density (7.14 g/cm37.14\text{ g/cm}^3).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the reference baseline in relative comparison formulas. Percent error always measures discrepancy relative to the accepted true standard, which serves as the base (denominator).

REASONING PATH
Your ACEpath teacher’s suggested approach
Reference Baseline Rule
  • Percent Error=Experimental−AcceptedAccepted×100%\text{Percent Error} = \frac{\text{Experimental} - \text{Accepted}}{\text{Accepted}} \times 100\%

  • Always verify that the accepted literature value appears in the denominator before evaluating.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. True Percent Error=6.955 g/cm3−7.14 g/cm37.14 g/cm3×100%=−0.1857.14×100%≈−2.5%\text{True Percent Error} = \frac{6.955\text{ g/cm}^3 - 7.14\text{ g/cm}^3}{7.14\text{ g/cm}^3} \times 100\% = \frac{-0.185}{7.14} \times 100\% \approx -2.5\%

  2. Inverted Result=7.14 g/cm3−6.955 g/cm37.14 g/cm3×100%=+0.1857.14×100%≈+2.5%\text{Inverted Result} = \frac{7.14\text{ g/cm}^3 - 6.955\text{ g/cm}^3}{7.14\text{ g/cm}^3} \times 100\% = \frac{+0.185}{7.14} \times 100\% \approx +2.5\%

Final answer

True percent error: −2.5%-2.5\% (experimental underestimate); Inverted result: +2.5%+2.5\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check that the literature benchmark (accepted value) is placed in the denominator for all relative error equations.

  • Practice identifying whether an error is positive (overestimate) or negative (underestimate) directly from the numerator difference (Experimental−Accepted)(\text{Experimental} - \text{Accepted}).

OverviewACEpath Teacher's Diagnosis

02 The student rounds the experimental density prematurely to two significant figures, leading to inaccurate percent error values.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Density=12.381.78=7.0 g/cm3\text{Density} = \frac{12.38}{1.78} = 7.0\text{ g/cm}^3

    Correct

    Density=12.38 g1.78 cm3≈6.955 g/cm3≈6.96 g/cm3\text{Density} = \frac{12.38\text{ g}}{1.78\text{ cm}^3} \approx 6.955\text{ g/cm}^3 \approx 6.96\text{ g/cm}^3

    Because the volume (1.78 mL1.78\text{ mL}) has three significant figures and the mass (12.38 g12.38\text{ g}) has four, your intermediate density quotient must retain at least three significant figures (6.96 g/cm36.96\text{ g/cm}^3, or unrounded as 6.955 g/cm36.955\text{ g/cm}^3). Rounding prematurely to 7.0 g/cm37.0\text{ g/cm}^3 discards too much precision.

  2. Step 2

    Conventional error=(7.0−7.147.14)×100%=−1.96%\text{Conventional error} = \left(\frac{7.0 - 7.14}{7.14}\right) \times 100\% = -1.96\%

    Correct

    Percent Error=6.955−7.147.14×100%≈−2.5%\text{Percent Error} = \frac{6.955 - 7.14}{7.14} \times 100\% \approx -2.5\%

    You applied the standard percent error formula correctly, but substituting the prematurely rounded value 7.0 g/cm37.0\text{ g/cm}^3 led to an inaccurate numerical answer.

  3. Step 3

    The negative sign means the measured density is smaller than accepted.

  4. Step 4

    Student error=(7.14−7.07.14)×100%=+1.96%\text{Student error} = \left(\frac{7.14 - 7.0}{7.14}\right) \times 100\% = +1.96\%

    Correct

    Student Result=7.14−6.9557.14×100%≈+2.5%\text{Student Result} = \frac{7.14 - 6.955}{7.14} \times 100\% \approx +2.5\%

    Your formula setup for the swapped numerator was correct according to the prompt, but the numerical answer was affected by the earlier rounding error.

  5. Step 5

    A negative sign in this formula would mean experimental is greater than accepted.

WHAT YOU DID WELL
Compliments from Your Teacher

You set up both the standard and the inverted percent error formulas accurately.

You clearly and correctly explained the physical significance of the sign in both conventions.

You showed neat, well-organized steps throughout your solution.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Premature Rounding of Intermediate Values

You rounded 6.955…6.955\dots to two significant figures (7.07.0) instead of maintaining three significant figures.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Rounding an intermediate result before the final calculation introduces significant rounding error, especially when subtracting two close numbers in a subsequent step.

REASONING PATH
Your ACEpath teacher’s suggested approach
Intermediate Precision Rule
  • Always carry at least one extra guard digit (or the full unrounded calculator value) during intermediate steps, and round only the final result to the correct number of significant figures.

  • Store 6.955… g/cm36.955\dots\text{ g/cm}^3 in your calculator or keep it to at least three significant figures before computing percent error.

Subtraction Sensitivity
  • When subtracting two numbers of similar magnitude, rounding either value drastically distorts their difference.

  • Notice that 7.0−7.14=−0.147.0 - 7.14 = -0.14, whereas 6.955−7.14=−0.1856.955 - 7.14 = -0.185, which changes the numerator by more than 24%24\%.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Keep the experimental density to three significant figures or carry unrounded: Density=12.38 g1.78 cm3≈6.955 g/cm3\text{Density} = \frac{12.38\text{ g}}{1.78\text{ cm}^3} \approx 6.955\text{ g/cm}^3.

  2. Substitute into the conventional formula: 6.955−7.147.14×100%=−0.1857.14×100%≈−2.5%\frac{6.955 - 7.14}{7.14} \times 100\% = \frac{-0.185}{7.14} \times 100\% \approx -2.5\%.

  3. Substitute into the inverted formula: 7.14−6.9557.14×100%=+0.1857.14×100%≈+2.5%\frac{7.14 - 6.955}{7.14} \times 100\% = \frac{+0.185}{7.14} \times 100\% \approx +2.5\%.

Final answer

True conventional percent error: −2.5%-2.5\%; Inverted student result: +2.5%+2.5\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Retain intermediate digits in your calculator memory instead of rounding early.

  • Check significant figures at each step based on the given measurements (1.78 mL1.78\text{ mL} has three significant figures, so the density must have at least three).

  • Review how small roundoff errors in intermediate differences drastically alter percentage calculations.

Lock it in

Similar question

01

A student measures the boiling point of an unknown organic liquid as 76.8∘C76.8^\circ\text{C}. The reference handbook lists the accepted boiling point as 78.4∘C78.4^\circ\text{C}. Calculate the conventional percent error and state whether the measurement is an overestimate or an underestimate.

Answer

Percent Error=76.8∘C−78.4∘C78.4∘C×100%=−1.678.4×100%≈−2.0%\text{Percent Error} = \frac{76.8^\circ\text{C} - 78.4^\circ\text{C}}{78.4^\circ\text{C}} \times 100\% = \frac{-1.6}{78.4} \times 100\% \approx -2.0\%. The negative sign indicates an underestimate.

02

An aluminum cylinder has a mass of 28.35 g28.35\text{ g} and displaces 10.2 mL10.2\text{ mL} of water. Given that the accepted density of aluminum is 2.70 g/cm32.70\text{ g/cm}^3, calculate the experimental density and the conventional percent error.

Answer

Experimental Density=28.35 g10.2 cm3≈2.779 g/cm3\text{Experimental Density} = \frac{28.35\text{ g}}{10.2\text{ cm}^3} \approx 2.779\text{ g/cm}^3. Percent Error=2.779−2.702.70×100%≈+2.9%\text{Percent Error} = \frac{2.779 - 2.70}{2.70} \times 100\% \approx +2.9\%, indicating an experimental overestimate.

03

During a calibration experiment, a pipette delivers an experimental volume yielding a percent error of +1.8%+1.8\%. If the accepted standard volume is 25.00 mL25.00\text{ mL}, find the actual volume delivered by the pipette. If an analyst mistakenly divided by the experimental volume to get +1.8%+1.8\%, what incorrect volume would they deduce?

Answer

Correct volume: Vexp=25.00×(1+0.018)=25.45 mLV_{\text{exp}} = 25.00 \times (1 + 0.018) = 25.45\text{ mL}. Incorrectly setting Vexp−25.00Vexp=0.018\frac{V_{\text{exp}} - 25.00}{V_{\text{exp}}} = 0.018 yields Vexp=25.001−0.018≈25.46 mLV_{\text{exp}} = \frac{25.00}{1 - 0.018} \approx 25.46\text{ mL}.

Loading workspace…